995 resultados para Measurement points
Resumo:
This paper details a method of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. Specifically a distributed coordinate measurement device was tested which consisted of a network of Rotary-Laser Automatic Theodolites (R-LATs), this system is known commercially as indoor GPS (iGPS). The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. © Springer-Verlag Berlin Heidelberg 2010.
Resumo:
The oxygen isotopic composition of pore waters squeezed from sediments in Hole 817C co-varies with the oxygen isotopic composition of Globigerinoides ruber below 8 mbsf. The magnitude of the variation in the pore water d18O is approximately 30% of the variation in the foraminifers. Overall, the d18O of the pore waters increases down the core, a trend that is also present in the Cl- concentrations. The variations in the d18O of pore waters may be the result of either of two phenomena. First, these may reflect original variations in the waters, the magnitude of which has been subsequently reduced by process of diffusion. Second, these may reflect recrystallization of the precursor sediment and isotopic exchange between the fluids and the recrystallized sediment. At the moment data are not available to ascertain which process is responsible although the correlation between the Cl- and the d18O data suggests that these values reflect the original composition modified by diffusion.
Resumo:
During the 14th expedition of the research vessel "Meteor" from the 2nd of July to the 7th of August 1968 continously recording instruments for measuring the CO2 partial pressure of seawater and atmospheric CO2 were developped by the Meteorological Institute, University of Frankfurt/M. During the Faroer expedition instrumental constants, such as relative and absolute accuracy, inertia and solvent power were tested. The performance of discontinous analyses of water samples was adopted to shipboard conditiones and correction factors depending on water volume, depth of sampling and water temperature were measured. After having computed average values of the continous records (atmosp. CO2 content, CO2 partial pressure, water temperature) geographical distribution, diurnal variation and dependence of diurnal averages were tested. At four different locations CO2 partial pressure was measured in various depths. During the voyage from the Faroer islands to Helgoland the measured concentrations of atmospheric CO2 content and CO2 partial pressure were tested with respect to a correlation of the geographical latitude.
Resumo:
From 1974 to 1982 repeated tracer tests using fluorescent dyes were carried out in the highly glaciated drainage basin of Vernagtbach. These tests enabled the quantitative determination of the runoff in the forefield of the Vernagtferner, the calculation of travel times of the stream water and estimations of the relative contributions to the entire runoff originating from individual streams. In addition, tracer tests were carried out in the firn area of the glacier resulting in data concerning the storage and travel time of meltwater inside the glacier.
Resumo:
Ce projet de recherche s’inscrit dans le domaine de la dosimétrie à scintillation en radiothérapie, plus précisément en curiethérapie à haut débit de dose (HDR). Lors de ce type de traitement, la dose est délivrée localement, ce qui implique de hauts gradients de dose autour de la source. Le but de ce travail est d’obtenir un détecteur mesurant la dose en 2 points distincts et optimisé pour la mesure de dose en curiethérapie HDR. Pour ce faire, le projet de recherche est séparé en deux études : la caractérisation spectrale du détecteur à 2-points et la caractérisation du système de photodétecteur menant à la mesure de la dose. D’abord, la chaine optique d’un détecteur à scintillation à 2-points est caractérisée à l’aide d’un spectromètre afin de déterminer les composantes scintillantes optimales. Cette étude permet de construire quelques détecteurs à partir des composantes choisies pour ensuite les tester avec le système de photodétecteur multi-point. Le système de photodétecteur est aussi caractérisé de façon à évaluer les limites de sensibilité pour le détecteur 2-points choisi précédemment. L’objectif final est de pouvoir mesurer le débit de dose avec précision et justesse aux deux points de mesure du détecteur multi-point lors d’un traitement de curiethérapie HDR.
Resumo:
Thesis (Master's)--University of Washington, 2016-08
Resumo:
Using antiprotons from the Low Energy Antiproton Ring at CERN, an investigation of the reaction pp -+ AA at threshold has been completed. This work includes a thorough scan of the 2 MeV region where a hint of a cross section resonance had been observed. No such resonance is evident in this work. In all, the cross section is measured in 30 energy bins. These measurements range from reaction threshold to 6.0 MeV excess energy in 0.25 MeV steps. An additional six points in the 13 MeV region have also been determined. Here, these cross sections and the differential cross sections in five energy bins will be presented.
Resumo:
My study investigated internal consistency estimates of psychometric surveys as an operationalization of the state of measurement precision of constructs in industrial and organizational (I/O) psychology. Analyses were conducted of samples used in research articles published in the Journal of Applied Psychology between 1975 and 2010 in five year intervals (K = 934) from 480 articles yielding 1427 coefficients. Articles and their respective samples were coded for test-taker characteristics (e.g., age, gender, and ethnicity), research settings (e.g., lab and field studies), and actual tests (e.g., number of items and scale anchor points). A reliability and inter-item correlations depository was developed for I/O variables and construct groups. Personality measures had significantly lower inter-item correlations than other construct groups. Also, internal consistency estimates and reporting practices were evaluated over time, demonstrating an improvement in measurement precision and missing data.
Resumo:
We report measurements of single- and double-spin asymmetries for W^{±} and Z/γ^{*} boson production in longitudinally polarized p+p collisions at sqrt[s]=510 GeV by the STAR experiment at RHIC. The asymmetries for W^{±} were measured as a function of the decay lepton pseudorapidity, which provides a theoretically clean probe of the proton's polarized quark distributions at the scale of the W mass. The results are compared to theoretical predictions, constrained by polarized deep inelastic scattering measurements, and show a preference for a sizable, positive up antiquark polarization in the range 0.05
Resumo:
To investigate endotoxin levels from primary endodontic infections before and after chemomechanical preparation (CMP) and to determine their antigenicity against 3T3 fibroblasts through gelatinolytic activity of matrix metalloproteinases (MMPs). Twenty-four root canals with primary endodontic infection and apical periodontitis were selected. Samples were collected using paper points before (S1) and after chemomechanical preparation (CMP) (S2). The limulus amebocyte lysate assay was used for endotoxin measurement. Fibroblasts were stimulated with root canal contents for 24 h. Supernatants of cell cultures stimulated with root canal contents were collected after 24 h to determine the levels of MMP-2 and MMP-9 gelatinolytic activity using the zymography technique. Friedman and Wilcoxon tests were used to compare the amount of endotoxin before (S1) and after CMP (S2) (P < 0.05). Data obtained from gelatinolytic activity were analysed using anova and Tukey's tests (P < 0.05). Endotoxin was recovered in 100% of the samples. There was a significant reduction in endotoxin levels after CMP (P < 0.05). A correlation was found between the levels of endotoxins and MMP-2 expression (P < 0.05). Root canal contents of initial samples (S1) induced significantly greater MMP-2 expression by fibroblasts when compared to S2 and the nonstimulated group (P < 0.05). No gelatinolytic activity of MMP-9 was observed in S1, S2 and control group. Root canal contents from primary endodontic infections had gelatinolytic activity for MMP-2. Moreover, CMP was effective in reducing endotoxin levels and their antigenicity against fibroblasts on gelatinolytic activity.
Resumo:
Chronic pain has been often associated with myofascial pain syndrome (MPS), which is determined by myofascial trigger points (MTrP). New features have been tested for MTrP diagnosis. The aim of this study was to evaluate two-dimensional ultrasonography (2D US) and ultrasound elastography (UE) images and elastograms of upper trapezius MTrP during electroacupuncture (EA) and acupuncture (AC) treatment. 24 women participated, aged between 20 and 40 years (M ± SD = 27.33 ± 5.05) with a body mass index ranging from 18.03 to 27.59 kg/m2 (22.59 ± 3.11), a regular menstrual cycle, at least one active MTrP at both right (RTPz) and left trapezius (LTPz) and local or referred pain for up to six months. Subjects were randomized into EA and AC treatment groups and the control sham AC (SHAM) group. Intensity of pain was assessed by visual analogue scale; MTrP mean area and strain ratio (SR) by 2D US and UE. A significant decrease of intensity in general, RTPz, and LTPz pain was observed in the EA group (p = 0.027; p < 0.001; p = 0.005, respectively) and in general pain in the AC group (p < 0.001). Decreased MTrP area in RTPz and LTPz were observed in AC (p < 0.001) and EA groups (RTPz, p = 0.003; LTPz, p = 0.005). Post-treatment SR in RTPz and LTPz was lower than pre-treatment in both treatment groups. 2D US and UE effectively characterized MTrP and surrounding tissue, pointing to the possibility of objective confirmation of subjective EA and AC treatment effects.
Resumo:
One of the most important properties of quantum dots (QDs) is their size. Their size will determine optical properties and in a colloidal medium their range of interaction. The most common techniques used to measure QD size are transmission electron microscopy (TEM) and X-ray diffraction. However, these techniques demand the sample to be dried and under a vacuum. This way any hydrodynamic information is excluded and the preparation process may alter even the size of the QDs. Fluorescence correlation spectroscopy (FCS) is an optical technique with single molecule sensitivity capable of extracting the hydrodynamic radius (HR) of the QDs. The main drawback of FCS is the blinking phenomenon that alters the correlation function implicating in a QD apparent size smaller than it really is. In this work, we developed a method to exclude blinking of the FCS and measured the HR of colloidal QDs. We compared our results with TEM images, and the HR obtained by FCS is higher than the radius measured by TEM. We attribute this difference to the cap layer of the QD that cannot be seen in the TEM images.
Resumo:
Measurement instruments are an integral part of clinical practice, health evaluation and research. These instruments are only useful and able to present scientifically robust results when they are developed properly and have appropriate psychometric properties. Despite the significant increase of rating scales, the literature suggests that many of them have not been adequately developed and validated. The scope of this study was to conduct a narrative review on the process of developing new measurement instruments and to present some tools which can be used in some stages of the development process. The steps described were: I-The establishment of a conceptual framework, and the definition of the objectives of the instrument and the population involved; II-Development of the items and of the response scales; III-Selection and organization of the items and structuring of the instrument; IV-Content validity, V-Pre-test. This study also included a brief discussion on the evaluation of the psychometric properties due to their importance for the instruments to be accepted and acknowledged in both scientific and clinical environments.
Resumo:
This study investigated the presence of target bacterial species and the levels of endotoxins in teeth with apical periodontitis. Levels of inflammatory mediators (interleukin [IL]-1β and tumor necrosis factor [TNF]-α) were determined after macrophage stimulation with endodontic content after different phases of endodontic therapy using different irrigants. Thirty primarily infected root canals were randomly assigned into 3 groups according to the irrigant used for root canal preparation (n = 10 per group): GI: 2.5% sodium hypochlorite, GII: 2% chlorhexidine gel, and GIII (control group): saline solution. Root canal samples were taken by using paper points before (s1) and after root canal instrumentation (s2), subsequently to 17% EDTA (s3), after 30 days of intracanal medication (Ca[OH]2 + saline solution) (s4), and before root canal obturation (s5). Polymerase chain reaction (16S recombinant DNA) and limulus amebocyte lysate assay were used for bacterial and endotoxin detection, respectively. Macrophages were stimulated with the root canal contents for IL-1β/TNF-α measurement using enzyme-linked immunosorbent assay. Porphyromonas gingivalis (17/30), Porphyromonas endodontalis (15/30), and Prevotella nigrescens (11/30) were the most prevalent bacterial species. At s1, endotoxins were detected in 100% of the root canals (median = 32.43 EU/mL). In parallel, substantial amounts of IL-1β and TNF-α were produced by endodontic content-stimulated macrophages. At s2, a significant reduction in endotoxin levels was observed in all groups, with GI presenting the greatest reduction (P < .05). After a root canal rinse with EDTA (s3), intracanal medication (s4), and before root canal obturation (s5), endotoxin levels reduced without differences between groups (P < .05). IL-1β and TNF-α release decreased proportionally to the levels of residual endotoxin (P < .05). Regardless of the use of sodium hypochlorite or CHX, the greatest endotoxin reduction occurs after chemomechanical preparation. Increasing steps of root canal therapy associated with intracanal medication enhances endotoxin reduction, leading to a progressively lower activation of proinflammatory cells such as macrophages.