876 resultados para Measured signals
Resumo:
Techniques based on signal analysis for leak detection in water supply systems typically use long pressure and/or flow data series of variable length. This paper presents the feature extraction from pressure signals and their application to the identification of changes related to the onset of a leak. Example signals were acquired from an experimental laboratory circuit, and features were extracted from temporal domain and from transformed signals. Statistical analysis of features values and a classification method were applied. It was verified the feasibility of using feature vectors for distinguish data acquired in the absence or presence of a leak.
Resumo:
We propose and experimentally demonstrate a simple and accurate technique for measuring differential mode group delay (DMGD) in few mode fibers (FMF). A frequency-swept microwave signal is modulated on a filtered optical incoherent source. The microwave signals carried on different fiber modes experience different time delays and interfere with each other in the photodetector. Optical interference between propagating fiber modes is avoided by the use of an incoherent optical source. A mathematical model is established to analyze the interference pattern and extract the DMGD values. A 456-m two-mode fiber and a 981-m FMF, which supports four LP modes, are measured. The measurement covers the whole C-band and the results coincide well with those obtained by the time-of-flight method and the numerical simulations. A precision of ±0.002 ps/m is achieved.
Resumo:
Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.
Resumo:
The activation of a2-adrenoceptors with bilateral injections of moxonidine (a2-adrenoceptor and imidazoline receptor agonist) into the lateral parabrachial nucleus (LPBN) increases 1.8% NaCl intake induced by treatment with furosemide (FURO) + captopril (CAP) subcutaneously. In the present study, we analyzed licking microstructure during water and 1.8% NaCl intake to investigate the changes in orosensory and postingestive signals produced by moxonidine injected into the LPBN. Male Sprague–Dawley rats were treated with FURO + CAP combined with bilateral injections of vehicle or moxonidine (0.5 nmol/0.2 ll) into the LPBN. Bilateral injections of moxonidine into the LPBN increased FURO + CAP-induced 1.8% NaCl intake, without changing water intake. Microstructural analysis of licking behavior found that this increase in NaCl intake was a function of increased number of licking bursts from 15 to 75 min of the test (maximum of 49 ± 9 bursts/bin, vs. vehicle: 2 ± 2 bursts/bin). Analysis of the first 15 min of the test, when most of the licking behavior occurred, found no effect of moxonidine on the number of licks/burst for sodium intake (24 ± 5 licks/burst, vs. vehicle: 27 ± 8 licks/burst). This finding suggests that activation of a2-adrenoceptors in the LPBN affects postingestive signals that are important to inhibit and limit sodium intake by FURO + CAP-treated rats.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A CMOS/SOI circuit to decode PWM signals is presented as part of a body-implanted neurostimulator for visual prosthesis. Since encoded data is the sole input to the circuit, the decoding technique is based on a double-integration concept and does not require dc filtering. Nonoverlapping control phases are internally derived from the incoming pulses and a fast-settling comparator ensures good discrimination accuracy in the megahertz range. The circuit was integrated on a 2 mu m single-metal SOI fabrication process and has an effective area of 2mm(2) Typically, the measured resolution of encoding parameter a was better than 10% at 6MHz and V-DD=3.3V. Stand-by consumption is around 340 mu W. Pulses with frequencies up to 15MHz and alpha = 10% can be discriminated for V-DD spanning from 2.3V to 3.3V. Such an excellent immunity to V-DD deviations meets a design specification with respect to inherent coupling losses on transmitting data and power by means of a transcutaneous link.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Since the discovery of YBaCuO, experiments have shown that its superconducting properties are strongly affected by the oxygen content. More recently, anelastic relaxation measurements in La2CuO4+δ, showed that the decrease in the oxygen content can be related to two events. One is the decrease in mobility between two adjacent CuO planes, and the other is the increase in the number of tilting patterns of the CuO6 octahedra. In the case of the bismuth-based ceramic, it is known that the oxygen content, within some limits, does not affect its superconducting properties. In order to evaluate the mobility and the effect of the oxygen content on this material we have prepared BSCCO ceramic and tested regarding its internal friction and electrical resistivity as a function of the temperature while the oxygen content was being reduced by a sequence of vacuum annelaing at 620 K. The samples were prepared in the Bi:Sr:Ca:Cu = 2212 and 2223 proportion, using powder obtained by the sol-gel route and conventional solid state reaction. The anelastic relaxation measurements were performed using a torsion pendulum operating with frequency about 15-35 Hz between 77 to 700 K. The diffraction pattern of the as sintered and the vacuum annealed material were also presented. The results have shown complex anelastic relaxation structures that were associated to the jump of interstitial oxygen atoms between two adjacent CuO planes. The vacuum annealing showed to be deleterious to the critical temperature of the superconducting ceramic.
Resumo:
Many researchers became interested in the discovery of Bi(2)Sr(2)CaCu(2)O(8+delta) oxides with critical temperature of around 80 K. It is known that the critical temperature is related to the CuO2 planes of the material. For this reason, the study of the interstitial oxygen in these oxides is of great relevance. The samples were prepared by means of conventional solid state reactions, through the stoichiometric mixture of precursory powders. After the sinterization, the samples were submitted to measurements of density, electrical resistivity, x-ray diffraction, scanning electron microscopy and energy dispersion spectroscopy, with the objective of performing their characterization. The measurements of mechanical spectroscopy were performed by a torsion pendulum. The results show three relaxation processes in the temperature range of 200 and 700 K, with activation energy of approximately 0.9 eV, which has been attributed to the dynamics of the interstitial oxygen present in the material.
Resumo:
Conselho Nacional de Desenvolvimento Cientifico e Tecnológico (CNPq)