876 resultados para Maximal Aerobic Speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the years, grinding has been considered one of the most important manufacturing processes. Grinding is a high precision process, and the loss of a single workpiece in this stage of the production is unacceptable, fir the value added to the material is very high due to many processes it has already undergone prior to grinding. This study aims to contribute toward the development of an experimental methodology whereby the pressure and speed of the air layer produced by the high rotation of the grinding wheel is evaluated with and without baffles, i.e., in an optimized grinding operation and in a traditional one. Tests were also carried out with steel samples to check the difference in grinding wheel wear with and without the use of baffles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The world tendency is the increase of the productivity and the production of pieces more and more sophisticated, with high degree of geometric and dimensional tolerances, with good surface finish and low cost. Rectification is responsible for the final finish in the machining process of a material. However, damages generated in this production phase affect all the resources used in the previous processes. Great part of the problems happennig in the rectification process is due to the enormous temperature generated in this activity because of the machining conditions. The dive speed, which is directly related to the productivity, is considered responsible for the damages that occur during rectification, limiting its values to those that do not cause such damages. In this work, through the variation of the dive speed in the process of cylindrical grinding of type ABNT D6 steel, rationalizing the application of two cutting fluids and using a CBN (cubic boron nitrate) abrasive wheel with vitrified blond, the influence of the dive speed on the surface damages of hardened steels was evaluated. The results allowed to say that the dive speed, associated to an efficient cooling and lubrication, didn't provoke thermal damages (including heated zones, cracks and tension stresses) to the material. Residual stresses and the roughness of rectified materials presented a correlation with the machining conditions. The work concluded that it is possible to increase the productivity without provoking damages in the rectified components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on analyses of high-speed video recordings of cloud-to-ground lightning in Brazil and the USA, the characteristics of positive cloud-to-ground (+CG) leaders are presented. The high frame rates permitted the average, 2-dimensional speeds of development along the paths of the channels to be resolved with good accuracy. The values range from 0.3 to 6.0 x 10(5) ms(-1) with a mean of 2.7 x 10(5) ms(-1). Contrary to what is usually assumed, downward +CG leader speeds are similar to downward -CG leader speeds. Our observations also show that the speeds tend to increase by a factor of 1.1 to 6.5 as they approach the ground. The presence of short duration, recoil leaders (RLs) during the development of positive leaders reveal a highly branched structure that is not usually recorded when using conventional photographic and video cameras. The existence of the RLs may help to explain observations of UHF-VHF radiation during the development of +CG flashes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A atividade do sistema renina-angiotensina-aldosterona tem relação direta com sobrepeso e sedentarismo, e essas variáveis se associam à hipertensão arterial (HA). O exercício aeróbio propicia melhor controle da pressão arterial (PA) por agir nos mecanismos da regulação pressórica, dentre eles, a atividade de renina plasmática (ARP). OBJETIVO: Avaliar a influência do exercício aeróbio sobre ARP em portadores de HA com sobrepeso. MÉTODOS: Foram avaliados níveis pressóricos, bioquímicos e antropométricos pré e pós-treinamento de 16 semanas, três vezes por semana, a 60%-80% da frequência cardíaca máxima. Os dados foram expressos em média ± desvio padrão ou mediana e intervalo interquartílico, e analisados pelo teste t, Mann-Withney e ANOVA (p < 0,05). RESULTADOS: Vinte indivíduos apresentaram média de idade de 57 ± 7,0 anos e índice de massa corpórea de 30 ± 3,5 kg/m². O treinamento aeróbio promoveu a redução da porcentagem de gordura corporal (35 ± 7,8 para 30 ± 5,6 %), da frequência cardíaca (FC) (80 ± 10,4 para 77 ± 8,5 bpm) e da pressão de pulso (PP) (50 ± 11,8 para 46 ± 10,0 mmHg) na amostra geral (p < 0,05), sem redução da ARP, que variou de 0,8 (0,45-2,0) a 1,45 (0,8-2,15) ηg/ml/h (p = 0,055). No grupo com redução da circunferência abdominal (CA) (n = 8) houve redução da PA sistólica e PP (p < 0,05). No grupo sem redução da CA, nenhuma das variáveis pressóricas apresentou alteração. A ARP não se associou com nenhuma variável estudada. O efeito do treinamento aeróbio associou-se à redução da PP na casuística total e à redução da PA sistólica no subgrupo com redução da CA. CONCLUSÃO: O treinamento aeróbio não reduziu a ARP em hipertensos com sobrepeso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)