935 resultados para Load voltages
Resumo:
This paper presents a pulsewidth modulation dc-dc nonisolated buck converter using the three-state switching cell, constituted by two active switches, two diodes, and two coupled inductors. Only part of the load power is processed by the active switches, reducing the peak current through the switches to half of the load current, as higher power levels can then be achieved by the proposed topology. The volume of reactive elements, i.e., inductors and capacitors, is also decreased since the ripple frequency of the output voltage is twice the switching frequency. Due to the intrinsic characteristics of the topology, total losses are distributed among all semiconductors. Another advantage of this converter is the reduced region for discontinuous conduction mode when compared to the conventional buck converter or, in other words, the operation range in continuous conduction mode is increased, as demonstrated by the static gain plot. The theoretical approach is detailed through qualitative and quantitative analyses by the application of the three-state switching cell to the buck converter operating in nonoverlapping mode $(D < 0.5)$. Besides, the mathematical analysis and development of an experimental prototype rated at 1 kW are carried out. The main experimental results are presented and adequately discussed to clearly identify its claimed advantages. © 1986-2012 IEEE.
Resumo:
BACKGROUND AND GOAL: Patients infected with hepatitis C virus (HCV) with elevated low-density lipoprotein (LDL) levels achieve higher sustained virologic response (SVR) rates after peginterferon (PegIFN)/ribavirin treatment versus patients with lower LDL. Our aim was to determine whether SVR rates in patients with low/elevated LDL can be improved by dose intensification. STUDY: In PROGRESS, genotype 1 patients with baseline HCV RNA≥400,000 IU/mL and body weight ≥85 kg were randomized to 48 weeks of 180 μg/wk PegIFN α-2a (40 kDa) plus ribavirin (A: 1200 mg/d; B: 1400/1600 mg/d) or 12 weeks of 360 μg/wk PegIFN α-2a followed by 36 weeks of 180 μg/wk, plus ribavirin (C: 1200 mg/d; D: 1400/1600 mg/d). This retrospective analysis assessed SVR rates among patients with low (<100 mg/dL) or elevated (≥100 mg/dL) LDL. Patients with high LDL (n=256) had higher baseline HCV RNA (5.86×10 IU/mL) versus patients with low LDL (n=262; 4.02×10 IU/mL; P=0.0003). RESULTS: Multiple logistic regression analysis identified a significant interaction between PegIFN α-2a dose and LDL levels on SVR (P=0.0193). The only treatment-related SVR predictor in the nested multiple logistic regression was PegIFN α-2a dose among patients with elevated LDL (P=0.0074); therefore, data from the standard (A+B) and induction (C+D) dose arms were pooled. Among patients with low LDL, SVR rates were 40% and 35% in the standard and induction-dose groups, respectively; SVR rates in patients with high LDL were 44% and 60% (P=0.014), respectively. CONCLUSIONS: Intensified dosing of PegIFN α-2a increases SVR rates in patients with elevated LDL even with the difficult-to-cure characteristics of genotype 1, high baseline viral load, and high body weight. Copyright © 2013 by Lippincott Williams & Wilkins.
Resumo:
Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.
Resumo:
Brazil is the world's largest producer of sugar cane and which in the state of São Paulo concentrate the greatest amount of sugar cane field of the country. The sugar-alcohol sector has the capacity to produce sufficient thermal and electrical energy to be used in their process of production and commercialize of surplus in electricity distribution network. Therefore it is necessary to evaluate the energy efficiency and rationality within the mill. Accordingly this research proposed analyze the sugar-alcohol mill's sectors globally and individually, located in the west center of the São Paulo state, using the valuation methodology employed by the Agência Nacional de Energia Elétrica (ANEEL) in the industries that do not have systems of cogeneration. In this analysis, the hyperboloids of load and potency were applied based on the indexes of potency factor and load factor that allow estimate the efficiency and rationality. © 2013 IEEE.
Resumo:
An alternative and simplified procedure is described to estimate the longitudinal resistances of transmission lines based on the real-time load profile. This method proposes to estimate the resistance parameters from the synchronized measurements of complex currents and complex voltages at the sending and receiving ends of transmission systems. The synchronized measurements can be in practice obtained using phasor measurement units (PMUs). © 2012 Springer-Verlag Berlin Heidelberg.
Resumo:
Patients infected with the human immunodeficiency virus (HIV) are at higher risk of developing Epstein-Barr Virus (EBV)-associated lymphomas. The usefulness of monitoring EBV in peripheral blood mononuclear cells (PBMCs) of patients infected with HIV has not been established. The aim of this study was to evaluate the EBV viral load in PBMCs, the frequency of viral genotypes, and the presence of the 30-bp deletion in the BNLF-1 gene. DNA samples from 156 patients attending the HIV/AIDS Day Clinic at Botucatu School of Medicine, Sao Paulo State University were evaluated. The EBV viral load was detectable by real time PCR in 123/156 (78.8%) cases and was higher in patients not receiving antiretroviral treatment or under therapeutic failure than in patients under successful highly active antiretroviral therapy (HAART) (P=0.0076). Overall, the profile of patients with high EBV viral load included elevated HIV viremia (P=0.0005), longer time of HIV diagnosis (P=0.0026), and increased levels of T CD8 + lymphocytes (P=0.0159). The successful amplification of the EBNA-2 gene by nested-PCR was achieved in 95 of 123 (77.2%) cases, of which 75.8% were EBV-1, 9.5% EBV-2, and 14.7% were co-infected with both EBV-1 and -2. The analysis of the BNLF-1 gene was possible in 99 of 123 (80.5%) cases, of which 50.5% had the 30-bp deletion. EBV-1 was more common than EBV-2, which may reflect the fact that the cohort was predominantly Caucasian and heterosexual. J. Med. Virol. 85:2110-2118, 2013. © 2013 Wiley Periodicals, Inc.
Resumo:
Includes bibliography
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Host genetic factors play an important role in mediating resistance to HIV-1 infection and may modify the course of infection. HLA-B alleles (Bw4 epitope; B*27 and B*57) as well as killer cell immunoglobulin-like receptors have been associated with slow progression of HIV-1 infection. OBJECTIVE: To evaluate the association between serological epitopes HLA-Bw4 and HLA-Bw6 and prognostic markers in AIDS. METHODS: 147 HIV-infected individuals in Bahia, Northeast Brazil, were genotyped for HLA class I locus. HLA class I genotyping was performed by hybridization with sequence-specific oligonucleotide probes following amplification of the corresponding HLA-A, HLA-B and HLA-C genes. Statistical analysis was performed using Fisher's exact and ANOVA tests for categorical and continuous variables, respectively. RESULTS: We detected a significant association (χ2 = 4.856; p = 0.018) between the presence of HLA-Bw4 and low levels of viremia. Eighteen out of the 147 HIV-infected individuals presented viremia <1,800 copies/mL and 129 presented viremia > 2,000 copies/mL. Ninety and four percent (17/18) of all individuals with viremia < 1,800 copies/mL carried HLA-Bw4, compared to 67.4% (87/129) of individuals with viremia > 2,000 copies/mL. Additionally, we found a significantly higher frequency of B*57 (OR = 13.94; 95% CI = 4.19-46.38; p < 0.0001) and Cw*18 (OR = 16.15; 95% CI = 3.46-75.43; p < 0.0001) alleles, favoring the group with lower viremia levels, in comparison with those with higher viral load. CONCLUSION: HLA-Bw4-B*57 and Cw*18 alleles are associated with lower level of viral load in HIV-infected Brazilian patients. These findings may help us in understanding the determinants of HIV evolution in Brazilian patients, as well as in providing important information on immune response correlates of protection for such population.
Resumo:
O crescente aumento da demanda de energia elétrica tem forçado o avanço tecnológico dos equipamentos responsáveis pelo transporte desta energia fazendo com que estes trabalhem sob tensões cada vez maiores, principalmente por razões econômicas. Mas este fato implica diretamente no incremento do diâmetro do condutor, o que acarreta elevação de seus custos, bem como das estruturas que devem suportá-lo. Para atender a esta necessidade sem aumentar o custo de projeto da linha de transmissão, surgiu a idéia de utilizar mais de um condutor por fase, montados paralelamente entre si a pequenas distâncias, o que é conseguido através da inserção de espaçadores montados a intervalos regulares ao longo dos vãos das linhas. Por outro lado, problemas mecânicos de ordem operacional das linhas podem ocorrer, como, por exemplo, a ruptura total ou parcial dos cabos e/ou espaçadores, proveniente de excitações dinâmicas devidas ao vento. Assim, este trabalho consiste no estudo do comportamento dinâmico de feixe de cabos de linhas aéreas de transmissão, através de um modelo de elementos finitos. O modelo reproduz o acoplamento dos cabos aos espaçadoresamortecedores da linha de transmissão e às estruturas de ancoragem, considerando o efeito de não-linearidade geométrica, decorrente dos grandes deslocamentos dos cabos, bem como a continuidade da linha, ou seja, os vãos adjacentes, que são representados por rigidez equivalente no modelo. O carregamento de vento é modelado através de um processo não deterministico a partir de suas propriedades estatísticas, tal que fica subdividido em duas partes: uma parte média, analisada de forma estática; e uma parte variável, analisada de forma dinâmica. Os resultados obtidos ao longo desse estudo mostram que a parcela variável do carregamento leva a uma resposta dinâmica do modelo que pode ser determinante no seu comportamento. Assim, o procedimento tradicional de assumir o carregamento do vento como uma excitação estática pode levar, em alguns casos a conseqüências desastrosas.
Resumo:
Este trabalho apresenta o desenvolvimento e a aplicação em campo de um sistema para verificação metrológica de transformadores de corrente em alta tensão. O sistema foi desenvolvido utilizando como premissas básicas a portabilidade e a confiabilidade metrológica, de tal forma que pudesse ser facilmente transportado e instalado, sem interrupção do fornecimento de energia elétrica nem o uso de infraestrutura complexa de transporte e montagem. O sistema utiliza como padrão de referência um transdutor ótico, cujo sensor mede a corrente elétrica do primário do transformador de corrente a ser verificado através do efeito magneto-ótico de Faraday. Ele também é composto por outros instrumentos padrão que medem a corrente elétrica do secundário do transformador de corrente sob verificação, e realizam a comparação entre esta e o sinal da saída do transdutor ótico padrão. Foram realizados ensaios em laboratório e em campo. Os ensaios em campo foram realizados em duas subestações em Belém/PA, visando avaliar a correta operação do sistema em condições de alta tensão e alta corrente. Os ensaios foram realizados em seis transformadores de corrente conectados em 230 kV, em condições médias de carga, e obtiveram resultados satisfatórios.