987 resultados para Intravascular ultrasound imaging
Resumo:
OBJECTIVES: To evaluate the current effectiveness of routine prenatal ultrasound screening in detecting gastroschisis and omphalocele in Europe. DESIGN: Data were collected by 19 congenital malformation registries from 11 European countries. The registries used the same epidemiological methodology and registration system. The study period was 30 months (July 1st 1996-December 31st 1998) and the total number of monitored pregnancies was 690,123. RESULTS: The sensitivity of antenatal ultrasound examination in detecting omphalocele was 75% (103/137). The mean gestational age at the first detection of an anomaly was 18 +/- 6.0 gestational weeks. The overall prenatal detection rate for gastroschisis was 83% (88/106) and the mean gestational age at diagnosis was 20 +/- 7.0 gestational weeks. Detection rates varied between registries from 25 to 100% for omphalocele and from 18 to 100% for gastroschisis. Of the 137 cases of omphalocele less than half of the cases were live births (n = 56; 41%). A high number of cases resulted in fetal deaths (n = 30; 22%) and termination of pregnancy (n = 51; 37%). Of the 106 cases of gastroschisis there were 62 (59%) live births, 13 (12%) ended with intrauterine fetal death and 31 (29%) had the pregnancies terminated. CONCLUSIONS: There is significant regional variation in detection rates in Europe reflecting different policies, equipment and the operators' experience. A high proportion of abdominal wall defects is associated with concurrent malformations, syndromes or chromosomal abnormalities, stressing the need for the introduction of repeated detailed ultrasound examination as a standard procedure. There is still a relatively high rate of elective termination of pregnancies for both defects, even in isolated cases which generally have a good prognosis after surgical repair.
Resumo:
PURPOSE: To introduce a new k-space traversal strategy for segmented three-dimensional echo planar imaging (3D EPI) that encodes two partitions per radiofrequency excitation, effectively reducing the number excitations used to acquire a 3D EPI dataset by half. METHODS: The strategy was evaluated in the context of functional MRI applications for: image quality compared with segmented 3D EPI, temporal signal-to-noise ratio (tSNR) (the ability to detect resting state networks compared with multislice two-dimensional (2D) EPI and segmented 3D EPI, and temporal resolution (the ability to separate cardiac- and respiration-related fluctuations from the desired blood oxygen level-dependent signal of interest). RESULTS: Whole brain images with a nominal voxel size of 2 mm isotropic could be acquired with a temporal resolution under half a second using traditional parallel imaging acceleration up to 4× in the partition-encode direction and using novel data acquisition speed-up of 2× with a 32-channel coil. With 8× data acquisition speed-up in the partition-encode direction, 3D reduced excitations (RE)-EPI produced acceptable image quality without introduction of noticeable additional artifacts. Due to increased tSNR and better characterization of physiological fluctuations, the new strategy allowed detection of more resting state networks compared with multislice 2D-EPI and segmented 3D EPI. CONCLUSION: 3D RE-EPI resulted in significant increases in temporal resolution for whole brain acquisitions and in improved physiological noise characterization compared with 2D-EPI and segmented 3D EPI. Magn Reson Med 72:786-792, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32?33 (97%) cancerous biopsies and rejected 17?20 (85%) noncancerous lesions.
Resumo:
AIM: The first pathogenetic step in multiple myeloma is the emergence of a limited number of clonal plasma cells, clinically known as monoclonal gammopathy of undetermined significance (MGUS). Patients with MGUS do not have symptoms or end-organ damage but they do have a 1% annual risk of progression to multiple myeloma or related malignant disorders. With progression of MGUS to multiple myeloma, complex genetic events occur in the neoplastic plasma cell. Karyotyping and fluorescence in-situ hybridization (FISH) were shown to be of prognostic value in patients with multiple myeloma. Tc-sestamibi imaging reflects myeloma disease activity in bone marrow with very high sensitivity and specificity predicting disease evolution. This study was undertaken to evaluate the role of Tc-sestamibi imaging and cytogenetic analysis in prognosis prediction of MGUS and multiple myeloma. METHODS: We enrolled 30 consecutive patients with a confirmed diagnosis of multiple myeloma or MGUS. Bone marrow biopsy and biochemical staging according to the International Staging System (ISS) were performed in all cases. Karyotype analysis and FISH were performed in 11 of 12 patients with MGUS and in 17 of 18 patients with multiple myeloma having adequate metaphases. RESULTS: The karyotype was abnormal in four of 11 MGUS and in six of 17 multiple myeloma. Abnormalities of chromosome 13 were present in one case of MGUS and in six cases of multiple myeloma whereas the involvement of immunoglobulin was observed in one case of multiple myeloma. An abnormal FISH panel was found in four MGUS and nine multiple myeloma patients. All patients with MGUS showed a normal MIBI scan (score 0). Among patients with multiple myeloma only three, all with ISS stage I, showed a normal scan while a positive scan was obtained in others (score range, 1-7). The MIBI uptake was strongly related to the bone marrow plasma cell infiltration and to cytogenetic abnormalities. Particularly, a MIBI uptake score above 5 identified patients with poor prognosis encompassing all stage III multiple myeloma and three of seven stage II multiple myeloma. On the other hand all stage I and II patients having a MIBI score less than 5 showed a good prognosis. CONCLUSION: Both cytogenetic analysis and a MIBI scan add no relevant prognostic information to the ISS in patients with stage I and III multiple myeloma. The MIBI scan was of prognostic value in stage II multiple myeloma patients. Additionally, MIBI imaging may be useful to guide bone marrow biopsy in order to obtain adequate samples for cytogenetic analysis.
Resumo:
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.
Resumo:
OBJECTIVE: To evaluate morphological and perfusion changes in liver metastases of neuroendocrine tumours by contrast-enhanced ultrasound (CEUS) after transarterial embolisation with bead block (TAE) or trans-arterial chemoembolisation with doxorubicin-eluting beads (DEB-TACE). METHODS: In this retrospective study, seven patients underwent TAE, and ten underwent DEB-TACE using beads of the same size. At 1 day before embolisation, 2 days, 1 month and 3 months after the procedure, a destruction-replenishment study using CEUS was performed with a microbubble-enhancing contrast material on a reference tumour. Relative blood flow (rBF) and relative blood volume (rBV) were obtained from the ratio of values obtained in the tumour and in adjacent liver parenchyma. Morphological parameters such as the tumour's major diameter and the viable tumour's major diameter were also measured. A parameter combining functional and morphological data, the tumour vitality index (TVI), was studied. The Wilcoxon rank-sum test and Fisher's test were used to compare treatment groups. RESULTS: At 3 months rBF, rBV and TVI were significantly lower (P = 0.005, P = 0.04 and P = 0.03) for the group with doxorubicin. No difference in morphological parameters was found throughout the follow-up. CONCLUSIONS: One parameter, TVI, could evaluate the morphological and functional response to treatments.
Resumo:
Multidetector row computed tomography (MDCT) is the imaging modality of reference for the diagnosis of bronchiectasis. MDCT may also detect a focal stenosis, a tumor or multiple morphologic abnormalities of the bronchial tree. It may orient the endoscopist towards the abnormal bronchi, and in all cases assess the extent of the bronchial lesions. The CT findings of bronchial abnormalities include anomalies of bronchial division and origin, bronchial stenosis, bronchial wall thickening, lumen dilatation, and mucoid impaction. The main CT features of bronchiectasis are increased bronchoarterial ratio, lack of bronchial tapering, and visibility of peripheral airways. Other bronchial abnormalities include excessive bronchial collapse at expiration, outpouchings and diverticula, dehiscence, fistulas, and calcifications.
Resumo:
In mammals, glycogen synthesis and degradation are dynamic processes regulating blood and cerebral glucose-levels within a well-defined physiological range. Despite the essential role of glycogen in hepatic and cerebral metabolism, its spatiotemporal distribution at the molecular and cellular level is unclear. By correlating electron microscopy and ultra-high resolution ion microprobe (NanoSIMS) imaging of tissue from fasted mice injected with (13)C-labeled glucose, we demonstrate that liver glycogenesis initiates in the hepatocyte perinuclear region before spreading toward the cell membrane. In the mouse brain, we observe that (13)C is inhomogeneously incorporated into astrocytic glycogen at a rate ~25 times slower than in the liver, in agreement with prior bulk studies. This experiment, using temporally resolved, nanometer-scale imaging of glycogen synthesis and degradation, provides greater insight into glucose metabolism in mammalian organs and shows how this technique can be used to explore biochemical pathways in healthy and diseased states. FROM THE CLINICAL EDITOR: By correlating electron microscopy and ultra-high resolution ion microprobe imaging of tissue from fasting mice injected with (13)C-labeled glucose, the authors demonstrate a method to image glycogen metabolism at the nanometer scale.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Resumo:
As an emerging alternative to DXA, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non invasive assessment of fracture risk in the management of osteoporosis. While the potential of QUS in the management of osteoporosis have been highly recognized by the scientific community and granted by the majority of the international bone disease organizations, it becomes important to develop strategies how to use ultrasound clinically. Our paper is highlighting Swiss operational clinical propositions for 2 QUS devices sold in Switzerland, on how to use the QUS in the management of osteoporosis.
Resumo:
Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.