994 resultados para Initial solution
Resumo:
The objective of this work was to compare the relative efficiency of initial selection and genetic parameter estimation, using augmented blocks design (ABD), augmented blocks twice replicated design (DABD) and group of randomised block design experiments with common treatments (ERBCT), by simulations, considering fixed effect model and mixed model with regular treatment effects as random. For the simulations, eight different conditions (scenarios) were considered. From the 600 simulations in each scenario, the mean percentage selection coincidence, the Pearsons´s correlation estimates between adjusted means for the fixed effects model, and the heritability estimates for the mixed model were evaluated. DABD and ERBCT were very similar in their comparisons and slightly superior to ABD. Considering the initial stages of selection in a plant breeding program, ABD is a good alternative for selecting superior genotypes, although none of the designs had been effective to estimate heritability in all the different scenarios evaluated.
Resumo:
A multicomponent indicator displacement assay ( MIDA) based on an organometallic receptor and three dyes can be used for the identification and quantification of nucleotides in aqueous solution at neutral pH.
Resumo:
We conducted an open, randomized, and prospective study to determine the effect of hypertonic saline on the secretion of antidiuretic hormone (ADH) and aldosterone in children with severe head injury (Glasgow coma scale <8). Thirty-one consecutive patients at a level III pediatric intensive care unit at a children's hospital received either lactated Ringer's solution (Ringer's group, n = 16) or hypertonic saline (Hypertonic Saline group, n = 15) over a 3-day period. Serum ADH levels were significantly larger in the Hypertonic Saline group as compared with the Ringer's group (P = 0.001; analysis of variance) and were correlated to sodium intake (Ringer's group: r = 0.39, R(2) = 0.15, P = 0.02; Hypertonic Saline group: r = 0.42, R(2) = 0.18, P = 0.02) and volume of fluids given IV (Ringer's group: r = 0.38, R(2) = 0.15, P = 0.02; Hypertonic Saline group: r = 0.32, R(2) = 0.1, P = not significant). Correlation of ADH to plasma osmolality was significant if plasma osmolality was >280 mOsm/kg (r = 0.5, R(2) = 0.25, P = 0.06), indicating an osmotic threshold for ADH release. Serum aldosterone levels were larger on the first day than during Days 2 and 3 in both groups and inversely correlated to serum sodium levels only in the Ringer's group (r = -0.55, R(2) = 0.3, P < 0.001). This group received a significantly larger fluid volume on Day 1 (P = 0.05, Mann-Whitney U-test) than did patients in the Hypertonic Saline group, indicating hypovolemia during the first day. Head-injured children have appropriate levels of ADH. They may be hypovolemic during the first day of treatment, especially if they receive lactated Ringer's solution. IMPLICATIONS: In head-injured patients, we recommend fluid restriction to avoid inappropriate secretion of antidiuretic hormone. In a prospective, randomized, and controlled study in 31 children, we were able to show that the antidiuretic hormone levels are appropriate in response to hypovolemia, sodium load, or both.
Resumo:
The Brianconnais area is explained as a large scale exotic terrain separating from Europe during the opening of the Valais ocean. It's displacement history during the Alpine evolution allows to replace older concepts of multiple oceans separating narrow strips of continental crust.
Resumo:
PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.
Resumo:
Purpose: To examine the efficacy and safety of repeat deep sclerectomy (DS) versus Baerveldt shunt (BS) implantation as second line surgery following failed primary DS. Methods: Fifty one patients were prospectively recruited to undergo BS implantation following failed DS and 51 patients underwent repeat DS, for which data was collected retrospectively. All eyes had at least one failed DS. Surgical success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline. Success rates, number of glaucoma medications (GMs), IOP, and complication rates were compared between the two groups at year 1, post-operatively. Results: Mean age, sex and the proportion of glaucoma subtypes were similar between groups. Preoperatively IOP was significantly lower in DS group vs BS group (18.8mmHg vs 23.8mmHg, p<0.01, two sample t-test). Postoperatively IOP was significantly higher in DS group than BS group (14.6mmHg vs 12.0mmHg, p<0.01, two-sample t-test). In the DS group, 47% of eyes did not achieve 20% reduction in IOP from baseline, as a result the success rates were significantly lower in eyes with DS (51%) than in eyes with BS (88%) (p=0.02, log-rank test). Preoperatively the number of GMs used in DS and BS groups were similar (2.2 vs 2.7 p=0.02, two sample t-test). Postoperatively there remained no significant difference in GMs between groups (0.9 vs 1.1, p= 0.58, two sample t-test). Complication rates were similar between the two groups (12% vs 10%). Conclusions: Baerveldt tube implantation was more effective in lowering IOP than repeat deep sclerectomy in eyes with failed primary DS, at year one. Complications were minor and infrequent in both groups
Resumo:
The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.
Resumo:
An image analysis method is presented which allows for the reconstruction of the three-dimensional path of filamentous objects from two of their projections. Starting with stereo pairs, this method is used to trace the trajectory of DNA molecules embedded in vitreous ice and leads to a faithful representation of their three-dimensional shape in solution. This computer-aided reconstruction is superior to the subjective three-dimensional impression generated by observation of stereo pairs of micrographs because it enables one to look at the reconstructed molecules from any chosen direction and distance and allows quantitative analysis such as determination of distances, curvature, persistence length, and writhe of DNA molecules in solution.
Resumo:
Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.
Resumo:
Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.