996 resultados para Imaging sensors
Resumo:
Keywords Diabetes mellitus; coronary artery disease; myocardial ischemia; prognostic value; single-photon emission computed tomography myocardial perfusion imaging Summary Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65±10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p<.0001), followed by history of CAD (Hazard Ratio (HR)= t 5.9, p=0.0001), diabetic retinopathy (HR=10.0, p=0.001) and inability to exercise (HR=7.7, p=0.02). Patients with normal 1VIPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5 fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. Mots-Clés Diabète; maladie coronarienne; ischémie myocardique; valeur pronostique; tomoscintigraphie myocardique de perfusion par émission monophotonique Résumé Objectifs: Déterminer la valeur pronostique à long terme de la tomoscintigraphie myocardique de perfusion (TSMP) chez les patients diabétiques pour prédire les événements cardiovasculaires (ECV). Méthodes: Etude de 210 diabétiques caucasiens consécutifs référés pour une TSMP. Les courbes de survie ont été déterminées par Kaplan-Meier et les facteurs prédictifs indépendants par analyses multivariées de type Cox. Résultats: Le suivi a été complet chez 200 (95%) patients avec une durée médiane de 3.0 ans (0.8-50). La population était composée de 114 (57%) hommes, âge moyen 65±10 ans, avec 181 (90.5%) diabète de type 2, 50 (25%) antécédents de maladie coronarienne (AMC) et 98 (49%) patients connus pour un angor avant la TSMP. La prévalence de TSMP anormales était de 58%. Aucun décès d'origine cardiaque ou infarctus du myocarde n'est survenu chez les patients avec une TSMP normale, ceci indépendamment de leurs AMC et des douleurs thoraciques. Les facteurs prédictifs indépendants pour les ECV sont une TSMP anormale (p<.0001), les AMC (Hazard Ratio (HR)=15.9, p-0.0001), suivi de la rétinopathie diabétique (HR-10.0, p=0.001) et de l'incapacité à effectuer un exercice (HR=7.7, p=0.02). Les patients avec une TSMP normale ont présenté un taux de revascularisations de 2.4%. La présence de défauts mixtes accroît le risque d'ECV de 20.1 fois, les défauts fixes de 8.5 fois et les défauts réversibles de 5.2 fois comparés aux sujets avec une TSMP normale. Conclusion: Les patients diabétiques, coronariens ou non, avec une tomoscintigraphie myocardique de perfusion normale ont un excellent pronostique. A l'opposé, une TSMP anormale est associée à une augmentation du risque d'ECV de plus de 5 fois. Ceci confirme l'utilité de la TSMP dans la stratification du risque chez les patients diabétiques.
Resumo:
BACKGROUND: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly being used for assessing the treatment succes in oncology, but the real clinical value needs to evaluated by comparison with other, already established, metabolic imaging techniques. PURPOSE: To prospectively evaluate the clinical potential of diffusion-weighted MRI with apparent diffusion coefficient (ADC) mapping for gastrointestinal stromal tumor (GIST) response to targeted therapy compared with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). MATERIAL AND METHODS: Eight patients (mean age, 56 ± 11 years) known to have metastatic GIST underwent 18F-FDG PET/CT and MRI (T1Gd, DWI [b = 50,300,600], ADC mapping) simultaneously, before and after change in targeted therapy. MR and PET/CT examinations were first analyzed blindly. Second, PET/CT images were co-registered with T1Gd-MR images for lesion detection. Only 18F-FDG avid lesions were considered. Maximum standardized uptake value (SUVmax) and the corresponding minimum ADCmin were measured for the six largest lesions per patient, if any, on baseline and follow-up examinations. The relationship between changes in SUVmax and ADCmin was analyzed (Spearman's correlation). RESULTS: Twenty-four metastases (12 hepatic, 12 extra-hepatic) were compared on PET/CT and MR images. SUVmax decreased from 7.7 ± 8.1 g/mL to 5.5 ± 5.4 g/mL (P = 0.20), while ADCmin increased from 1.2 ± 0.3 × 10(-3)mm(2)/s to 1.5 ± 0.3 × 10(-3)mm(2)/s (P = 0.0002). There was a significant association between changes in SUVmax and ADCmin (rho = - 0.62, P = 0.0014), but not between changes in lesions size (P = 0.40). CONCLUSION: Changes in ADCmin correlated with the response of 18F-FDG avid GIST to targeted therapy. Thus, diffusion-weighted MRI may represent a radiation-free alternative for follow-up treatment for metastatic GIST patients.
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.
Resumo:
Aquesta tesi explora la possibilitat de fer servir enllaços inductius per a una aplicació de l’automòbil on el cablejat entre la centraleta (ECU) i els sensors o detectors és difícil o impossible. S’han proposat dos mètodes: 1) el monitoratge de sensors commutats (dos possibles estats) via acoblament inductiu i 2) la transmissió mitjançant el mateix principi físic de la potència necessària per alimentar els sensors autònoms remots. La detecció d'ocupació i del cinturó de seguretat per a seients desmuntables pot ser implementada amb sistemes sense fils passius basats en circuits ressonants de tipus LC on l'estat dels sensors determina el valor del condensador i, per tant, la freqüència de ressonància. Els canvis en la freqüència són detectats per una bobina situada en el terra del vehicle. S’ha conseguit provar el sistema en un marge entre 0.5 cm i 3 cm. Els experiments s’han dut a terme fent servir un analitzador d’impedàncies connectat a una bobina primària i sensors comercials connectats a un circuit remot. La segona proposta consisteix en transmetre remotament la potència des d’una bobina situada en el terra del vehicle cap a un dispositiu autònom situat en el seient. Aquest dispositiu monitorarà l'estat dels detectors (d'ocupació i de cinturó) i transmetrà les dades mitjançant un transceptor comercial de radiofreqüència o pel mateix enllaç inductiu. S’han avaluat les bobines necessàries per a una freqüència de treball inferior a 150 kHz i s’ha estudiat quin és el regulador de tensió més apropiat per tal d’aconseguir una eficiència global màxima. Quatre tipus de reguladors de tensió s’han analitzat i comparat des del punt de vista de l’eficiència de potència. Els reguladors de tensió de tipus lineal shunt proporcionen una eficiència de potència millor que les altres alternatives, els lineals sèrie i els commutats buck o boost. Les eficiències aconseguides han estat al voltant del 40%, 25% i 10% per les bobines a distàncies 1cm, 1.5cm, i 2cm. Les proves experimentals han mostrat que els sensors autònoms han estat correctament alimentats fins a distàncies de 2.5cm.
Resumo:
Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.
Resumo:
Clinical use of the Stejskal-Tanner diffusion weighted images is hampered by the geometric distortions that result from the large residual 3-D eddy current field induced. In this work, we aimed to predict, using linear response theory, the residual 3-D eddy current field required for geometric distortion correction based on phantom eddy current field measurements. The predicted 3-D eddy current field induced by the diffusion-weighting gradients was able to reduce the root mean square error of the residual eddy current field to ~1 Hz. The model's performance was tested on diffusion weighted images of four normal volunteers, following distortion correction, the quality of the Stejskal-Tanner diffusion-weighted images was found to have comparable quality to image registration based corrections (FSL) at low b-values. Unlike registration techniques the correction was not hindered by low SNR at high b-values, and results in improved image quality relative to FSL. Characterization of the 3-D eddy current field with linear response theory enables the prediction of the 3-D eddy current field required to correct eddy current induced geometric distortions for a wide range of clinical and high b-value protocols.
Resumo:
We advocate the use of a novel compressed sensing technique for accelerating the magnetic resonance image acquisition process, coined spread spectrum MR imaging or simply s2MRI. The method resides in pre-modulating the signal of interest by a linear chirp, resulting from the application of quadratic phase profiles, before random k-space under-sampling with uniform average density. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The application of the technique for single coil acquisitions is thoroughly studied by means of numerical simulations as well as phantom and in vivo experiments on a 7T scanner. The corresponding results suggest a favorable comparison with state-of-the-art variable density k-space under-sampling approaches.
Resumo:
Monoclonal antibodies (MoAb) that react with the T-lymphocyte markers called cluster of differentiation CD5 and CD2 were labeled with iodine 131 (131I) and were injected intravenously in nude mice bearing solid subcutaneous xenografts derived from the human T-cell leukemia line Ichikawa. Both MoAb anti-CD5 and anti-CD2 yielded favorable mean tumor to whole-body ratios of 3.8 and 5.1, respectively. These ratios were further increased up to 10.0 for MoAb anti-CD5 and 15.5 for MoAb anti-CD2 by using their F(ab')2 fragments. The tumors could be imaged clearly by external scanning after injection of F(ab')2 fragments from both MoAb. F(ab')2 fragments from MoAb anti-CD2 and of a third MoAb recognizing the clonotypic determinant (Ti) of the antigen receptor expressed by the human T-cell line Jurkat were injected in mice bearing intrasplenic Jurkat xenografts. A selective localization of both fragments in tumor tissue was demonstrated with mean tumor to whole-body ratios of 7.5 and 4.1 for MoAb anti-CD2 and anti-Ti, respectively. These in vivo experimental results may provide useful information for the potential use of radiolabeled MoAb and fragments in the diagnosis and treatment of patients with T-cell lymphoma and different other forms of T-cell malignancies.
Resumo:
Congenital cardiopathies in adults are a rare clinical entity in the cardiology consultations. Advances in imaging techniques allow the fortuitous diagnosis of mild forms of these congenital abnormalities. We describe a case of an asymptomatic 41-year-old man, with a medical history of recurrent pneumonia during childhood and an established diagnosis of scimitar syndrome by computed tomography.
Resumo:
Chemosensation is the detection of chemical signals in the environment that enable an animal to make informed decisions about food choice, mate preference or predator detection. Dissecting the molecular and neural mechanisms by which animals detect chemical cues is an important goal towards understanding how they interact with the environment. An attractive system to dissect the mechanisms of chemosensation is the olfactory system. One of the most-investigated olfactory systems is that of Drosophila melanogaster, a model organism that is amenable to a powerful combination of genetic and physiological analyses. Embedded within the antennal olfactory organ of Drosophila is an unusual sensory structure called the sacculus. The sacculus is comprised of three distinct chambers, each lined with several sensilla housing two to three neurons. Previous morphological, anatomical and surgical studies of sacculus neurons have implicated sacculus neurons in chemosensation, hygrosensation and/or thermosensation. While a subset of sacculus neurons have been physiologically characterised as temperature sensors, the role of this organ has remained largely mysterious, due to its inaccessibility to peripheral electrophysiological analysis. Recently a new family of olfactory receptors, the lonotropic Receptors (IRs), was identified. Five IRs are expressed in sacculus neurons providing the first selective molecular markers for these cells. In this thesis I describe the molecular, physiological and anatomical characterisation of these neurons. Genetic labelling of specific populations of sacculus neurons with anatomical (CD8:GFP) reporters has identified neurons in sacculus chambers I and II express IR40a+IR93a together with their co- receptor IR25a, while neurons in chamber III express IR64a with its co-receptor IR8a. Both these sets of neurons project to two distinct glomeruli in the antennal lobe; IR40a neurons project to the column and arm, IR64a neurons project to DC4 and DP1m. Through a live optical imaging screen I showed that these neurons are indeed olfactory and IR64a neurons recognise acidic ligands, while IR40a neurons recognise amine ligands. IR40a and IR64a neurons are in fact composed of anatomically and physiologically distinct subpopulations, strongly implying the existence of other factors that define their functional properties. My thesis identifies the sacculus as a specialised olfactory organ capable of detecting acids and bases, which are of widespread importance to insects. The data from my thesis along with data from other labs show the sacculus is composed of different populations of olfactory sensory neurons and thermosensory neurons. Comparative genomic analysis of sacculus IRs across insects reveals them to be among the most conserved of this receptor repertoire, suggesting that the sacculus represents an evolutionarily ancient insect olfactory acid-base sensor. - La détection des produits chimiques se trouvant dans l'environnement (perception chimiosensorielle) permet à un animal de choisir sa nourriture, son partenaire ou encore d'identifier ses prédateurs. Décortiquer les mécanismes moléculaires et neuronaux grâce auxquels les animaux détectent ces signaux chimiques permet de comprendre comment ces animaux interagissent avec leur environnement. Un système intéressant pour décortiquer ces mécanismes de perception chimiosensorielle est le système olfactif, de la drosophile (Drosophila melanogaster), aussi appelée mouche du vinaigre. C'est un animal modèle très utile grâce à la combinaison d'outils génétiques puissants et d'analyses physiologiques facilement réalisables. Dans l'antenne de la drosophile, qui est l'organe olfactif principal de cet animal, se trouve une structure appelée sacculus. Celui-ci est composé de trois chambres distinctes, chacune comprenant plusieurs sensilles à l'intérieur desquelles se trouvent deux à trois neurones. De précédentes études morphologiques et anatomiques des ces neurones ont déterminé qu'ils sont impliqués dans la perception des odeurs, de l'humidité et de la température. Malgré ceci, la fonction principale de cet organe reste largement inconnue, principalement car il est inaccessible aux analyses électrophysiologiques. Récemment, une nouvelle famille de soixante-six récepteurs olfactifs, nommés Récepteurs lonotropiques (IRs), a été découverte chez la drosophile. Cinq IRs sont exprimés dans les neurones du sacculus. Pour la première fois, une sélection de marqueurs moléculaires est disponible pour l'étude de ces cellules. Dans cette thèse, les caractéristiques moléculaires, physiologiques et anatomiques des neurones du sacculus sont décrites. Ces populations de neurones situés dans le sacculus ont été marquées avec des gènes rapporteurs (CD8:GFP). Ceci a montré que les récepteurs IR40a et IR93a sont exprimés ensemble avec le co-récepteur IR25a dans les chambres I et II, tandis que les neurones de la chambre III expriment IR64a avec son co-récepteur IR8a. Ces deux groupes de neurones projettent vers deux glomérules distincts du lobe antennaire : les neurones IR40a projettent vers la column et le arm, alors que les neurones IR64a projettent vers DC4 et DP1m. Un screen d'imagerie optique a démontré que ces neurones sont en effet des neurones olfactifs, et que les neurones IR64a reconnaissent des ligands acides, tandis que les neurones IR40a reconnaissent des ligands aminés. De plus, les neurones IR40a et IR64a sont séparés en sous-populations distinctes anatomiquement et physiologiquement, et d'autres facteurs permettant de définir leurs propriétés fonctionnelles sont probablement impliqués. Cette thèse identifie ainsi le sacculus comme un organe olfactif spécialisé capable de détecter des acides et amines, lesquels sont très importants pour les insectes. Toutes les données collectées durant cette thèse, combinées aux données d'autres laboratoires, montrent que le sacculus est composé de différentes populations de neurones olfactifs et thermosenseurs. Ces IRs sont très conservés parmi les insectes, suggérant que le sacculus représente révolution d'un ancien détecteur olfactif d'acides et de bases chez l'insecte. - Tous les animaux sont capables de percevoir les signaux chimiques dans leur environnement, comme les odeurs ou le goût, via différents organes. L'odorat est le sens qui permet de percevoir les odeurs, et il est implique des neurones olfactifs qui se trouvent dans le nez des mammifères ou les antennes des insectes. La capacité d'un neurone olfactif à détecter une molécule odorante dépend des types de récepteurs olfactifs qu'il exprime. Il existe deux grandes familles de récepteurs qui perçoivent les odeurs : les Récepteurs Olfactifs, ORs, et Récepteurs lonotropiques IRs, qui détectent différents types d'odeurs avec différents mécanismes. Lorsqu'un récepteur reconnaît une molécule odorante, il convertit ce signal en un signal électrique qui est ensuite transmis au centre olfactif dans le cerveau. La drosophile (Drosophila melanogaster), aussi appelée mouche du vinaigre, est utilisée comme animal modèle pour étudier l'odorat, parce que son génome entier a été séquencé et que ses gènes sont facilement manipulables. De plus, l'anatomie du système olfactif de la mouche est similaire à celui des mammifères, malgré qu'il possède moins de neurones, ce qui le rend moins complexe. Ma thèse a pour objectif d'étudier les Récepteurs lonotropiques dans un organe spécifique, appelé le sacculus, situé dans les antennes. Les neurones du sacculus exprimant des IRs envoient leurs projections au centre olfactif du cerveau, suggérant que ces neurones perçoivent les odeurs. Une technique d'imagerie optique a été utilisée sur le cerveau de mouches vivantes afin de mesurer la réponse des neurones du le sacculus à différentes odeurs. J'ai démontré que ces récepteurs détectent des acides et des amines, qui sont très importants pour les insectes. Par exemple, les acides se retrouvent dans les fruits mûrs sur lesquels les mouches vont se nourrir, s'accoupler et poser leurs oeufs, et les amines sont souvent produites par des bactéries pouvant être nuisible pour la mouche. La principale découverte de ma thèse est donc l'identification du sacculus comme un organe capable de détecter deux des principales odeurs importantes pour la mouche. Ces récepteurs sont aussi présents dans d'autres insectes où ils jouent peut-être des rôles différents. Les acides et les amines se retrouvent aussi dans les excrétions (comme la sueur ou l'urine) de beaucoup de mammifères, qui pourraient potentiellement être dangereux pour la mouche, mais qui attirent les moustiques se nourrissant de leur sang.
Resumo:
In this paper we describe a system for underwater navigation with AUVs in partially structured environments, such as dams, ports or marine platforms. An imaging sonar is used to obtain information about the location of planar structures present in such environments. This information is incorporated into a feature-based SLAM algorithm in a two step process: (I) the full 360deg sonar scan is undistorted (to compensate for vehicle motion), thresholded and segmented to determine which measurements correspond to planar environment features and which should be ignored; and (2) SLAM proceeds once the data association is obtained: both the vehicle motion and the measurements whose correct association has been previously determined are incorporated in the SLAM algorithm. This two step delayed SLAM process allows to robustly determine the feature and vehicle locations in the presence of large amounts of spurious or unrelated measurements that might correspond to boats, rocks, etc. Preliminary experiments show the viability of the proposed approach
Resumo:
PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.