929 resultados para ISO 9001 Standard.
Resumo:
Farmers have difficult of determining the evenness of transverse distribution and the working width, due the tests with this aim require equipments and complex methodologies. So, this study evaluates some alternative containers with the aim to allow a more accessible adjustment of the full width of the solid fertilizer spreaders. Four different containers were tested: i) standard container constructed in accordance with ISO 5690/1; ii) container of polyethylene (plastic trays) with screen shading to prevent the ricochet of material; iii) containers composed by boxes of long-life milk, and iv) containers composed by flowerpots (number 3.5). Also, three different spreaders were used for the tests. Alternative containers showed greater retention of particles than the standardized containers. The full width of work obtained for the coefficients of variation of 12.5; 15; 17.5 and 20%, ranged due the containers in the different pathways. The flowerpots of polyethylene showed similar results to the standardized containers. The heights of the containers were more important for its efficiency than its area of collection.
Resumo:
Este trabalho teve como objetivo avaliar a conformidade dos acessos e de saídas dos postos de operação em tratores agrícolas, por meio de população amostral dos tratores fabricados no Brasil. Para a avaliação, diversos itens referentes aos acessos e às saídas dos postos de operação foram analisados qualitativa e quantitativamente com base nos padrões da Norma NBR/ISO 4252. Ao final do trabalho, foi observado que os tratores classificados na Classe III, quanto à potência nominal do motor, atendem ao maior número de requisitos da Norma em comparação a tratores da Classe II. Dentre os itens avaliados, a altura da plataforma até o teto dos postos de operação foi atendida por todos os modelos. As presenças de batentes de proteção sobre os degraus e de corrimão para o operador foram os itens em maior desconformidade sobre os tratores. Como resultado médio, a população amostral foi conforme em 66% dos itens analisados. Os tratores dotados de motores de maior potência apresentaram, em geral, acessos e saídas dos postos de operação mais ergonômicos e seguros. De maneira geral, conclui-se pela baixa conformidade dos itens de ergonomia e de segurança dispostos ao operador sobre os postos de operação em tratores agrícolas nacionais.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
The focus of this research was to evaluate the horizontal pressures on a cylindrical metal silo of corrugated walls and flat bottom with 1.82m diameter and 5.4m high, and to compare the values with those obtained theoretically by the ISO 11697, EP 433 and AS 3774 standards. The silo was symmetrically filled and constant speed with wheat cv. soft red for two different height/diameter ratios (H/D) and was unloaded through three orifices with a diameter of 71.6mm, one concentric and two eccentrics. Horizontal pressures were measured on the walls of the silo at three positions using hydraulic type pressure cells. The results showed that shortly after the start of the unloading, there was a mass flow above the quota of H/D = 1.2, whereas below this quota funnel flow occurred. It can be said that the EP 433 standard was more appropriate to predict horizontal pressures in silos in H/D ratio = 1.0, with eccentric unloading. For the H/D ratio = 1.5, AS 3774 standard was the one that produced values closer to the experimental.
Resumo:
OBJETIVO: avaliar a morbidade e a mortalidade cirúrgica em pacientes submetidos a gastroduodenopancreatectomia (GDP) com linfadenectomia padrão e radical para adenocarcinoma de papila, analisando os fatores prognósticos com relação à sobrevida global e livre de doença. MÉTODOS: foram analisados retrospectivamente no período de 1999 a 2007, no Serviço de Cirurgia Abdômino-Pélvica do INCa-RJ, 50 casos de GDP para adenocarcinoma da papila duodenal divididos em dois grupos de acordo com a linfadenectomia (grupo A: linfadenectomia padrão e grupo B: linfadenectomia radical). RESULTADOS: A mediana de idade foi semelhante nos dois grupos, assim como a distribuição entre os sexos. Na comparação entre as linfadenectomias somente o número de linfonodos ressecados (grupo A: 12,3 e grupo B: 26,5) e o tempo operatório (grupo A: 421 e grupo B: 474) foram significativamente diferentes. Não ocorreram diferenças estatisticamente significativas nos dois grupos com relação a morbi-mortalidade operatória e tempo de internação. A sobrevida livre de doença (grupo A: 35 meses e grupo B: 51 meses) e sobrevida global (grupo A: 38 meses e grupo B: 53 meses) foi maior no grupo da linfadenectomia radical, porém não foram significantes estatisticamente. CONCLUSÃO: no presente estudo não ocorreram casos de linfonodos metastáticos para outros grupos nodais sem o acometimento linfonodal das cadeias pancreato-duodenais (13 e 17), sugerindo um padrão de disseminação linfonodal. Apesar da linfadenectomia radical apresentar taxas de sobrevida livre de doença e sobrevida global maiores esses dados não foram significativos estatisticamente. Novos estudos devem ser realizados para avaliar o real papel da linfadenectomia radical no adenocarcinoma da papila duodenal.
Resumo:
Kirjallisuusarvostelu
Resumo:
Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.
Resumo:
Configuration management is often seen as an enabler for the main IT Service Management (ITSM) processes such as Incident and Problem management. A decent level of quality of IT configuration data is required in order to carry out routines of these processes. This case study examines the state of configuration management in a multinational organization and aims at identification of methods for its improvement. The author has stayed five months with this company in order to collect different sources of evidence and to make observations. The main source of data for this study is interviews with some of the key employees of the assigned organization who are involved into the ITSM processes. This study concludes the maturity level of the existing configuration management process to be repeatable but intuitive, and outlines the principal requirements for its improvement. A match between the requirements identified in the organization and the requirements stated in the ISO/IEC 20000 standard indicates the possibility of adopting ITIL guidelines as a method for configuration management process improvement. The outcome of the study presents a set of recommendations for improvement that considers the process, the information model and the information system for configuration management in the case organization.
Resumo:
kuv., 16 x 25 cm
Resumo:
kuv., 10 x 22 cm
Resumo:
kuv., 10 x 22 cm
Resumo:
kuv., 8 x 20 cm
Resumo:
kuv., 8 x 20 cm
Resumo:
kuv., 10 x 15 cm