917 resultados para INTRAOPERATIVE ULTRASOUND


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS In a controlled clinical trial, 48 patients (mean age 50±21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N=24) or conventional catheter-directed thrombolysis (N=24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55%±27% in the ultrasound-assisted catheter-directed thrombolysis group and 54%±27% in the conventional catheter-directed thrombolysis group (P=0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P>0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P>0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P=0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0±3.9 [range 0-15] versus 1.9±1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Continuous intraoperative norepinephrine infusion combined with restrictive deferred hydration improves surgical field visibility, and significantly decreases intraoperative blood loss and postoperative complications in patients undergoing radical cystectomy and urinary diversion. We determined whether the intraoperative fluid regimen would affect functional results (continence and erectile function) 1 year after orthotopic ileal bladder substitution. MATERIALS AND METHODS We analyzed a subgroup of 93 patients who received an ileal orthotopic bladder substitute. The subgroup was part of a randomized trial in 167 patients initially allocated to continuous norepinephrine administration starting with 2 μg/kg per hour combined with 1 ml/kg per hour initially and 3 ml/kg per hour crystalloid infusion after cystectomy (norepinephrine/low volume group of 51) or a standard crystalloid infusion of 6 ml/kg per hour throughout surgery (42 controls). We prospectively assessed daytime and nighttime continence, and erectile function 1 year postoperatively in the 93-patient subgroup. RESULTS Daytime continence was reported by 44 of 51 patients (86%) in the norepinephrine/low volume group and by 27 of 42 controls (64%) (p = 0.016), and nighttime continence was reported by 38 (75%) and 25 (60%), respectively (p = 0.077). Erectile function recovery was reported by 26 of 33 preoperatively potent patients (79%) in the norepinephrine/low volume group and by 11 of 29 controls (38%) (p = 0.002). CONCLUSIONS Patients who undergo radical cystectomy and orthotopic bladder substitution with continuous norepinephrine infusion and restrictive hydration during surgery have significantly better daytime continence and erectile function 1 year postoperatively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The primary aim of the study was to evaluate whether rheumatoid arthritis (RA) patients considered to be in remission according to clinical criteria sets still had persisting ultrasound (US) synovitis. We further intended to evaluate the capacity of our US score to discriminate between the patients with a clinically active disease versus those in remission. METHODS This is an observational study nested within the Swiss Clinical Quality Management in Rheumatic Diseases (SCQM) rheumatoid arthritis cohort. A validated US score (SONAR score) based on a semi-quantitative B-mode and Doppler (PwD) score as part of the regular clinical workup by rheumatologists in different clinical settings was used. To define clinically relevant synovitis, the same score was applied to 38 healthy controls and the 90st percentile was used as cut-off for 'relevant' synovitis. RESULTS Three hundred and seven patients had at least one US examination and concomitant clinical information on disease activity. More than a third of patients in both DAS28 and ACR/EULAR remission showed significant gray scale synovitis (P=0.01 and 0.0002, respectively) and PwD activity (P=0.005 and 0.0005, respectively) when compared to controls. The capacity of US to discriminate between the two clinical remission groups and patients with active disease was only moderate. CONCLUSION This observational study confirms that many patients considered to be in clinical remission according the DAS and the ACR/EULAR definitions still have residual synovitis on US. The prognostic significance of US synovitis and the exact place of US in patients reaching clinical remission need to be further evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the correlation between clinical measures of disease activity and a ultrasound (US) scoring system for synovitis applied by many different ultrasonographers in a daily routine care setting within the Swiss registry for RA (SCQM) and further to determine the sensitivity to change of this US Score. METHODS One hundred and eight Swiss rheumatologists were trained in performing the Swiss Sonography in Arthritis and Rheumatism (SONAR) score. US B-mode and Power Doppler (PwD) scores were correlated with DAS28 and compared between the clinical categories in a cross-sectional cohort of patients. In patients with a second US (longitudinal cohort), we investigated if change in US score correlated with change in DAS and evaluated the responsiveness of both methods. RESULTS In the cross-sectional cohort with 536 patients, correlation between the B-mode score and DAS28 was significant but modest (Pearson coefficient r = 0.41, P < 0.0001). The same was true for the PwD score (r = 0.41, P < 0.0001). In the longitudinal cohort with 183 patients we also found a significant correlation between change in B-mode and in PwD score with change in DAS28 (r = 0.54, P < 0.0001 and r = 0.46, P < 0.0001, respectively). Both methods of evaluation (DAS and US) showed similar responsiveness according to standardized response mean (SRM). CONCLUSIONS The SONAR Score is practicable and was applied by many rheumatologists in daily routine care after initial training. It demonstrates significant correlations with the degree of as well as change in disease activity as measured by DAS. On the level of the individual, the US score shows many discrepancies and overlapping results exist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate treatment response of hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with a new real-time imaging fusion technique of contrast-enhanced ultrasound (CEUS) with multi-slice detection computed tomography (CT) in comparison to conventional post-interventional follow-up. MATERIAL AND METHODS 40 patients with HCC (26 male, ages 46-81 years) were evaluated 24 hours after TACE using CEUS with ultrasound volume navigation and image fusion with CT compared to non-enhanced CT and follow-up contrast-enhanced CT after 6-8 weeks. Reduction of tumor vascularization to less than 25% was regarded as "successful" treatment, whereas reduction to levels >25% was considered as "partial" treatment response. Homogenous lipiodol retention was regarded as successful treatment in non-enhanced CT. RESULTS Post-interventional image fusion of CEUS with CT was feasible in all 40 patients. In 24 patients (24/40), post-interventional image fusion with CEUS revealed residual tumor vascularity, that was confirmed by contrast-enhanced CT 6-8 weeks later in 24/24 patients. In 16 patients (16/40), post-interventional image fusion with CEUS demonstrated successful treatment, but follow-up CT detected residual viable tumor (6/16). Non-enhanced CT did not identify any case of treatment failure. Image fusion with CEUS assessed treatment efficacy with a specificity of 100%, sensitivity of 80% and a positive predictive value of 1 (negative predictive value 0.63). CONCLUSIONS Image fusion of CEUS with CT allows a reliable, highly specific post-interventional evaluation of embolization response with good sensitivity without any further radiation exposure. It can detect residual viable tumor at early state, resulting in a close patient monitoring or re-therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.