810 resultados para INTERNAL REFLECTION
Resumo:
The vibrational spectrum of dimethyl acetylene has been remeasured with better resolving power than hitherto, and the rotational fine structure of some perpendicular type bands has been partly analyzed. The energy levels of a molecule of this kind in which internal rotation of methyl groups may arise have been re-examined theoretically and the rotational structure of the absorption bands has been more clearly defined than previously. The experimental results are consistent with the assumption of unrestricted internal rotation of the methyl groups, and the Coriolis factors $\zeta _{i}$ for several vibrations have been determined.
Resumo:
Orthogonal internal coordinates are defined which have useful properties for constructing the potential energy functions of triatomic molecules with two or three minima on the surface. The coordinates are used to obtain ground state potentials of ClOO and HOF, both of which have three minima.
Resumo:
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethyl-cyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS. Copyright (c) 2006 John Wiley & Sons, Ltd.
Resumo:
Conducts a study into how contrast could be established when using colours frequently used in everyday environments, and how different adjacent colours had to be in terms of chromaticity, saturation and/or hue in order for a difference to be discerned between them by fully sighted people and most visually impaired people. Location within a building where contrast would have the greatest benefits is considered. Relates the philosophy behind design procedures and decisions to meet the objectives.
Resumo:
In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.
Effect of internal partitioning on indoor air quality of rooms with mixing ventilation - basic study
Resumo:
The internal partitioning, which is frequently introduced in open-space planning due to its flexibility, was tested to study its effects on the room air quality as well as ventilation performance. For the study, physical tests using a small model room and numerical modeling using CFD computation were utilized to evaluate different test conditions employing mixing ventilation from the ceiling. The partition parameters, such as its location, height, and the gap underneath, as well as contaminant source location were tested under isothermal conditions. This paper summarizes the results from the study.
Resumo:
A one-dimensional shock-reflection test problem in the case of slab, cylindrical, or spherical symmetry is discussed. The differential equations for a similarity solution are derived and solved numerically in conjunction with the Rankie-Hugoniot shock relations.
Resumo:
A finite difference scheme is presented for the inviscid terms of the equations of compressible fluid dynamics with general non-equilibrium chemistry and internal energy.
Resumo:
A numerical mesoscale model is used to make a high-resolution simulation of the marine boundary layer in the Persian Gulf, during conditions of offshore flow from Saudi Arabia. A marine internal boundary layer (MIBL) and a sea-breeze circulation (SBC) are found to co-exist. The sea breeze develops in the mid-afternoon, at which time its front is displaced several tens of kilometres offshore. Between the coast and the sea-breeze system, the MIBL that occurs is consistent with a picture described in the existing literature. However, the MIBL is perturbed by the SBC, the boundary layer deepening significantly seaward of the sea-breeze front. Our analysis suggests that this strong, localized deepening is not a direct consequence of frontal uplift, but rather that the immediate cause is the retardation of the prevailing, low-level offshore wind by the SBC. The simulated boundary-layer development can be accounted for by using a simple 1D Lagrangian model of growth driven by the surface heat flux. This model is obtained as a straightforward modification of an established MIBL analytic growth model.
Resumo:
A synthesis method is outlined for the design of broadband anti-reflection coatings for use in spaceborne infrared optics. The Golden Section optimisation routine is used to make a search, using designated non-absorptive dielectric thin film combinations, for the coating design which fulfils the required spectral requirements using the least number of layers and different materials. Three examples are given of coatings designed by this method : (I) 1µm to 12µm anti-reflection coating on Zinc Sulphide using Zinc Sulphide and Yttrium Fluoride thin film materials. (ii) 2µm to 14µm anti-reflection coating on Germanium using Germanium and Ytterbium Fluoride thin film materials. (iii) 6µm to 17µm anti-reflection coating on Germanium using Lead Telluride, Zinc Selenide and Barium Fluoride. The measured spectral performance of the manufactured 6µm to 17µm coating on Germanium is given. This is the anti-reflection coating for the germanium optics in the NASA Cassini Orbiter CIRS instrument.