969 resultados para Historically accurate reconstructions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we present a map of the glacial geomorphology of the Altai andWestern Sayan Mountains, covering an area of almost 600,000 km2. Although numerous studies provide evidence for restricted Pleistocene glaciations in this area, others have hypothesized the past existence of an extensive ice sheet. To provide a framework for accurate glacial reconstructions of the Altai and Western Sayan Mountains, we present a map at a scale of 1:1,000,000 based on a mapping from 30 m resolution ASTER DEM and 15 m/30 mresolution Landsat ETM+ satellite imagery. Four landform classes have been mapped: marginal moraines, glacial lineations, hummocky terrain, and glacial valleys. Our mapping reveals an abundance of glacial erosional and depositional landforms. The distribution of these glacial landforms indicates that the Altai and Western Sayan Mountains have experienced predominantly alpine-style glaciations, with some small ice caps centred on the higher mountain peaks. Large marginal moraine complexes mark glacial advances in intermontane basins. By tracing the outer limits of present-day glaciers, glacial valleys, and moraines, we estimate that the past glacier coverage have totalled to 65,000 km2 (10.9% of the mapped area), whereas present-day glacier coverage totals only 1300 km2 (0.2% of the mapped area). This demonstrates the usefulness of remote sensing techniques for mapping the glacial geomorphology in remote mountain areas and for quantifying the past glacier dimensions. The glacial geomorphological map presented here will be used for further detailed reconstructions of the paleoglaciology and paleoclimate of the region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study aimed to explore methods of assessing interactions between neuronal sources using MEG beamformers. However, beamformer methodology is based on the assumption of no linear long-term source interdependencies [VanVeen BD, vanDrongelen W, Yuchtman M, Suzuki A. Localization of brain electrical activity via linearly constrained minimum variance spatial filtering. IEEE Trans Biomed Eng 1997;44:867-80; Robinson SE, Vrba J. Functional neuroimaging by synthetic aperture magnetometry (SAM). In: Recent advances in Biomagnetism. Sendai: Tohoku University Press; 1999. p. 302-5]. Although such long-term correlations are not efficient and should not be anticipated in a healthy brain [Friston KJ. The labile brain. I. Neuronal transients and nonlinear coupling. Philos Trans R Soc Lond B Biol Sci 2000;355:215-36], transient correlations seem to underlie functional cortical coordination [Singer W. Neuronal synchrony: a versatile code for the definition of relations? Neuron 1999;49-65; Rodriguez E, George N, Lachaux J, Martinerie J, Renault B, Varela F. Perception's shadow: long-distance synchronization of human brain activity. Nature 1999;397:430-3; Bressler SL, Kelso J. Cortical coordination dynamics and cognition. Trends Cogn Sci 2001;5:26-36]. Methods: Two periodic sources were simulated and the effects of transient source correlation on the spatial and temporal performance of the MEG beamformer were examined. Subsequently, the interdependencies of the reconstructed sources were investigated using coherence and phase synchronization analysis based on Mutual Information. Finally, two interacting nonlinear systems served as neuronal sources and their phase interdependencies were studied under realistic measurement conditions. Results: Both the spatial and the temporal beamformer source reconstructions were accurate as long as the transient source correlation did not exceed 30-40 percent of the duration of beamformer analysis. In addition, the interdependencies of periodic sources were preserved by the beamformer and phase synchronization of interacting nonlinear sources could be detected. Conclusions: MEG beamformer methods in conjunction with analysis of source interdependencies could provide accurate spatial and temporal descriptions of interactions between linear and nonlinear neuronal sources. Significance: The proposed methods can be used for the study of interactions between neuronal sources. © 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a Markov chain based analytical model is proposed to evaluate the slotted CSMA/CA algorithm specified in the MAC layer of IEEE 802.15.4 standard. The analytical model consists of two two-dimensional Markov chains, used to model the state transition of an 802.15.4 device, during the periods of a transmission and between two consecutive frame transmissions, respectively. By introducing the two Markov chains a small number of Markov states are required and the scalability of the analytical model is improved. The analytical model is used to investigate the impact of the CSMA/CA parameters, the number of contending devices, and the data frame size on the network performance in terms of throughput and energy efficiency. It is shown by simulations that the proposed analytical model can accurately predict the performance of slotted CSMA/CA algorithm for uplink, downlink and bi-direction traffic, with both acknowledgement and non-acknowledgement modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Macular oedema is not directly visible on digital photographs used in screening. Photographic surrogate markers are used to detect patients who may have macular oedema. Evidence suggests that only around 10% of patients with these surrogate markers referred to an ophthalmologist have macular oedema when examined by slit-lamp biomicroscopy. Purpose: The purpose of this audit was to determine how many patients with surrogate markers were truly identified by optical coherence tomography (OCT) as having macular oedema. Method: Data were collected from patients attending digital diabetic retinopathy screening. Patients who presented with surrogate markers for macular oedema also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Results: Out of 66 patients with maculopathy defined as haemorrhages or microaneurysms within one optic disc diameter (DD) of the fovea and visual acuity (VA) worse than 6/9 11 (17%) showed thickening on the OCT, only 4 (6%) had macular oedema. None required laser. Out of 155 patients with maculopathy defined as any exudate within one DD of the fovea or circinate within two DD 45 (29%) showed thickening on the OCT of these 27% required laser. Conclusion: OCT is a useful tool in screening to help identify those who need a true referral to ophthalmology for maculopathy. If exudate is present the chance of having macular oedema and requiring laser treatment is greater than the presence of microaneurysms within one DD and reduced VA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DESIGN. Retrospective analysis PURPOSE. Macular oedema is not directly visible on two dimensional digital photographs such that surrogate markers need to be used. In the English National Screening Programme these are exudate within one optic disc diameter (DD) of the fovea, group of exudates within two DD of the fovea and haemorrhages or microaneurysms (HMA) within one DD of the fovea with best corrected visual acuity (VA) worse than 6/9. All patients who present with any of these surrogate markers at screening are referred to an ophthalmology clinic for slit lamp examination. The purpose of this audit was to determine how many patients with positive maculopathy diagnosis on photography were truly identified by optical coherence tomography (OCT) with macular oedema. METHODS. Data was collected from patients attending digital diabetic retinopathy screening. Patients who presented with surrogate markers for macular oedema also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. RESULTS. Maculopathy by exudates: Of 155 patients 45 (29%) showed thickening on the OCT of these 12 required laser. Those who also had pre-proliferative retinopathy (n=20) were more likely to have macular oedema (75%) than those with background diabetic retinopathy. Maculopathy by HMA and VA worse than 6/9: Of 66 patients 11 (16.7%) showed thickening on the OCT. 5 (7.6%) of these had macular oedema, 5 (7.6%) epi-retinal membrane, and 1 (1.5%) age related macular degeneration. None of these patients required laser. CONCLUSIONS. The likelihood of the presence of macular oedema and requiring laser treatment is greater with macular exudation than HMA within one DD and reduced VA. Overall the surrogate markers used show low specificity for macular oedema, however combining OCT with photography does identify those with macular oedema who require a true referral for an ophthalmological slit lamp examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetoencephalography (MEG) can be used to reconstruct neuronal activity with high spatial and temporal resolution. However, this reconstruction problem is ill-posed, and requires the use of prior constraints in order to produce a unique solution. At present there are a multitude of inversion algorithms, each employing different assumptions, but one major problem when comparing the accuracy of these different approaches is that often the true underlying electrical state of the brain is unknown. In this study, we explore one paradigm, retinotopic mapping in the primary visual cortex (V1), for which the ground truth is known to a reasonable degree of accuracy, enabling the comparison of MEG source reconstructions with the true electrical state of the brain. Specifically, we attempted to localize, using a beanforming method, the induced responses in the visual cortex generated by a high contrast, retinotopically varying stimulus. Although well described in primate studies, it has been an open question whether the induced gamma power in humans due to high contrast gratings derives from V1 rather than the prestriate cortex (V2). We show that the beanformer source estimate in the gamma and theta bands does vary in a manner consistent with the known retinotopy of V1. However, these peak locations, although retinotopically organized, did not accurately localize to the cortical surface. We considered possible causes for this discrepancy and suggest that improved MEG/magnetic resonance imaging co-registration and the use of more accurate source models that take into account the spatial extent and shape of the active cortex may, in future, improve the accuracy of the source reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter we propose an Markov model for slotted CSMA/CA algorithm working in a non-acknowledgement mode, specified in IEEE 802.15.4 standard. Both saturation throughput and energy consumption are modeled as functions of backoff window size, number of contending devices and frame length. Simulations show that the proposed model can achieve a very high accuracy (less than 1% mismatch) if compared to all existing models (bigger than 10% mismatch).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative structure-activity relationship (QSAR) analysis is a cornerstone of modern informatics. Predictive computational models of peptide-major histocompatibility complex (MHC)-binding affinity based on QSAR technology have now become important components of modern computational immunovaccinology. Historically, such approaches have been built around semiqualitative, classification methods, but these are now giving way to quantitative regression methods. We review three methods--a 2D-QSAR additive-partial least squares (PLS) and a 3D-QSAR comparative molecular similarity index analysis (CoMSIA) method--which can identify the sequence dependence of peptide-binding specificity for various class I MHC alleles from the reported binding affinities (IC50) of peptide sets. The third method is an iterative self-consistent (ISC) PLS-based additive method, which is a recently developed extension to the additive method for the affinity prediction of class II peptides. The QSAR methods presented here have established themselves as immunoinformatic techniques complementary to existing methodology, useful in the quantitative prediction of binding affinity: current methods for the in silico identification of T-cell epitopes (which form the basis of many vaccines, diagnostics, and reagents) rely on the accurate computational prediction of peptide-MHC affinity. We have reviewed various human and mouse class I and class II allele models. Studied alleles comprise HLA-A*0101, HLA-A*0201, HLA-A*0202, HLA-A*0203, HLA-A*0206, HLA-A*0301, HLA-A*1101, HLA-A*3101, HLA-A*6801, HLA-A*6802, HLA-B*3501, H2-K(k), H2-K(b), H2-D(b) HLA-DRB1*0101, HLA-DRB1*0401, HLA-DRB1*0701, I-A(b), I-A(d), I-A(k), I-A(S), I-E(d), and I-E(k). In this chapter we show a step-by-step guide into predicting the reliability and the resulting models to represent an advance on existing methods. The peptides used in this study are available from the AntiJen database (http://www.jenner.ac.uk/AntiJen). The PLS method is available commercially in the SYBYL molecular modeling software package. The resulting models, which can be used for accurate T-cell epitope prediction, will be made are freely available online at the URL http://www.jenner.ac.uk/MHCPred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial lipoproteins have many important functions and represent a class of possible vaccine candidates. The prediction of lipoproteins from sequence is thus an important task for computational vaccinology. Naïve-Bayesian networks were trained to identify SpaseII cleavage sites and their preceding signal sequences using a set of 199 distinct lipoprotein sequences. A comprehensive range of sequence models was used to identify the best model for lipoprotein signal sequences. The best performing sequence model was found to be 10-residues in length, including the conserved cysteine lipid attachment site and the nine residues prior to it. The sensitivity of prediction for LipPred was 0.979, while the specificity was 0.742. Here, we describe LipPred, a web server for lipoprotein prediction; available at the URL: http://www.jenner.ac.uk/LipPred/. LipPred is the most accurate method available for the detection of SpaseIIcleaved lipoprotein signal sequences and the prediction of their cleavage sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A possibility of a strong change of an electromagnetic signal by a short sequence of time cycles of pulses that modulate the medium parameters is shown. The backward wave is demonstrated to be an inevitable result of the medium time change. Dependence of the relation between backward and forward waves on the parameters of the medium modulation is investigated. The finite statistical complexity of the electromagnetic signal transformed by a finite sequence of modulating cycles is calculated. Increase of the complexity with the number of cycles is shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential group delay measurement of narrowband fiber devices using a fiber polarization scrambler with a modulation phase shift technique is demonstrated. Accurate measurement is realized with high wavelength and delay resolution and immunity to environmental perturbation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Particle delivery to the airways is an attractive prospect for many potential therapeutics, including vaccines. Developing strategies for inhalation of particles provides a targeted, controlled and non-invasive delivery route but, as with all novel therapeutics, in vitro and in vivo testing are needed prior to clinical use. Whilst advanced vaccine testing demands the use of animal models to address safety issues, the production of robust in vitro cellular models would take account of the ethical framework known as the 3Rs (Replacement, Reduction and Refinement of animal use), by permitting initial screening of potential candidates prior to animal use. There is thus a need for relevant, realistic in vitro models of the human airways. Key findings Our laboratory has designed and characterised a multi-cellular model of human airways that takes account of the conditions in the airways and recapitulates many salient features, including the epithelial barrier and mucus secretion. Summary Our human pulmonary models recreate many of the obstacles to successful pulmonary delivery of particles and therefore represent a valid test platform for screening compounds and delivery systems.