975 resultados para Hernia abdominal
Resumo:
The CIAO Study is a multicenter observational study currently underway in 66 European medical institutions over the course of a six-month study period (January-June 2012).This preliminary report overviews the findings of the first half of the study, which includes all data from the first three months of the six-month study period.Patients with either community-acquired or healthcare-associated complicated intra-abdominal infections (IAIs) were included in the study.912 patients with a mean age of 54.4 years (range 4-98) were enrolled in the study during the first three-month period. 47.7% of the patients were women and 52.3% were men. Among these patients, 83.3% were affected by community-acquired IAIs while the remaining 16.7% presented with healthcare-associated infections. Intraperitoneal specimens were collected from 64.2% of the enrolled patients, and from these samples, 825 microorganisms were collectively identified.The overall mortality rate was 6.4% (58/912). According to univariate statistical analysis of the data, critical clinical condition of the patient upon hospital admission (defined by severe sepsis and septic shock) as well as healthcare-associated infections, non-appendicular origin, generalized peritonitis, and serious comorbidities such as malignancy and severe cardiovascular disease were all significant risk factors for patient mortality.White Blood Cell counts (WBCs) greater than 12,000 or less than 4,000 and core body temperatures exceeding 38°C or less than 36°C by the third post-operative day were statistically significant indicators of patient mortality.
Resumo:
Although routine ultrasound screening for abdominal aortic aneurysm (AAA) reduces mortality in subjects at risk, it is often omitted in clinical practice. Because computerized alerts may systematically identify subjects at risk of AAA, we hypothesized that such alerts would encourage physicians to perform an ultrasound screening test.
Resumo:
Whether total extraperitoneal inguinal hernia repair (TEP) is associated with worse outcomes than transabdominal preperitoneal inguinal hernia repair (TAPP) continues to be a matter of debate. The objective of this large cohort study is to compare outcomes between patients undergoing TEP or TAPP.
Resumo:
A recent study suggested that the anti-inflammatory effect of immunonutrition starts after only two d. We therefore investigated the effect of an immunoenriched oral diet administered for three d preoperatively.
Resumo:
OBJECTIVE: The study was conducted to determine activation of coagulation in patients undergoing open and endovascular infrarenal abdominal aortic aneurysm repair (EVAR). METHODS: In a prospective, comparative study, 30 consecutive patients undergoing open repair (n = 15) or EVAR (n = 15) were investigated. Blood samples to determine fibrinopeptide A, fibrin monomer, thrombin-antithrombin complex, and D-dimer were taken up to 5 days postoperatively. Routine hematologic and hematochemical parameters as well as clinical data were collected. RESULTS: Both groups showed comparable demographic variables. Operating time was longer in open repair (249 +/- 77 minutes vs 186 +/- 69 minutes, P < .05). Perioperatively elevated markers of coagulation were measured in both groups. Fibrinopeptide A levels did not differ significantly between the groups (P = .55). The levels of fibrin monomer and thrombin-antithrombin complex were significantly higher in patients undergoing EVAR (P < .0001), reflecting increased thrombin activity and thrombin formation compared with open surgery. The D-dimer level did not differ significantly between the groups. These results were also valid after correction for hemodilution. CONCLUSION: These data suggest increased procoagulant activity in EVAR compared with open surgery. A procoagulant state may favor possible morbidity derived from micro- and macrovascular thrombosis, such as in myocardial infarction, multiple organ dysfunction, venous thrombosis and thromboembolism, or disseminated intravascular coagulation.
Resumo:
Low cardiac output impairs the hepatic arterial buffer response (HABR). Whether this is due to low abdominal blood flow per se is not known. Dobutamine is commonly used to increase cardiac output, and it may further modify hepatosplanchnic and renal vasoregulation. We assessed the effects of isolated abdominal aortic blood flow changes and dobutamine on hepatosplanchnic and renal blood flow. Twenty-five anesthetized pigs with an abdominal aorto-aortic shunt were randomized to 2 control groups [zero (n = 6) and minimal (n = 6) shunt flow], and 2 groups with 50% reduction of abdominal blood flow and either subsequent increased abdominal blood flow by shunt reduction (n = 6) or dobutamine infusion at 5 and 10 microg kg(-1) min(-1) with constant shunt flow (n = 7). Regional (ultrasound) and local (laser Doppler) intra-abdominal blood flows were measured. The HABR was assessed during acute portal vein occlusion. Sustained low abdominal blood flow, by means of shunt activation, decreased liver, gut, and kidney blood flow similarly and reduced local microcirculatory blood flow in the jejunum. Shunt flow reduction partially restored regional blood flows but not jejunal microcirculatory blood flow. Low-but not high-dose dobutamine increased gut and celiac trunk flow whereas hepatic artery and renal blood flows remained unchanged. Neither intervention altered local blood flows. The HABR was not abolished during sustained low abdominal blood flow despite substantially reduced hepatic arterial blood flow and was not modified by dobutamine. Low-but not high-dose dobutamine redistributes blood flow toward the gut and celiac trunk. The jejunal microcirculatory flow, once impaired, is difficult to restore.
Resumo:
BACKGROUND: Ventral hernia repair is increasingly performed by laparoscopic means since the introduction of dual-layer meshes. This study aimed to compare the early complications and cost effectiveness of open hernia repair with those associated with laparoscopic repair. METHODS: Open ventral hernia repair was performed for 92 consecutive patients using a Vypro mesh, followed by laparoscopic repair for 49 consecutive patients using a Parietene composite mesh. RESULTS: The rate of surgical-site infections was significantly higher with open ventral hernia repair (13 vs 1; p = 0.03). The median length of hospital stay was significantly shorter with laparoscopic surgery (7 vs 6 days; p = 0.02). For laparoscopic repair, the direct operative costs were higher (2,314 vs 2,853 euros; p = 0.03), and the overall hospital costs were lower (9,787 vs 7,654 euros; p = 0.02). CONCLUSIONS: Laparoscopic ventral hernia repair leads to fewer surgical-site infections and a shorter hospital stay than open repair. Despite increased operative costs, overall hospital costs are lowered by laparoscopic ventral hernia repair.
Resumo:
BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.