888 resultados para Fio de Kirschner


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Filosofia - FFC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of Information and Communication Technology has grown in most agricultural activities. As a consequence, it has changed the way of thinking and acting of the farmer who wants to establish a more and more competitive market. However, the high costs of acquisition and maintenance of those technologies may be a factor which can inhibit its spread and acceptance, mainly to a large number of small grain Brazilian farmers. In this context, there is a need for innovative solutions that are proper for this universe of farmers. Starting from this premise, this paper presents the development of a low cost prototype to the monitoring process of temperature and humidity values of grains stored in silos, using communication based on wireless technology by radio frequency. Therefore, the economic implications of cost/benefit ratio of innovative application of wireless transmission in the process of thermometry of grains were analysed. The prototype was made of two electronic units, one of acquisition and another one of data reception, as well as computational software, which offered the farmer more precise information for the control of aeration. By means of stability, integrity and reliability tests of data transmission via radio, using low cost electronic components, the development system can be considered as potentially viable. It presented the difference regarding the wireless communication via radio in the process of grains thermometry, providing mobility, reducing cabling costs and maintenance, and also offering an easy system expansion; it was also appropriate to temperature and humidity monitoring in grain silos; and revealed operational viability, besides the low cost development when compared to similar products available in the Brazilian market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper was to perform an energy assessment of firewood and woodshaving use for energy generation in sericulture agroindustry boilers. In this research, we used a boiler from a silk spinning factory located in the city of Duartina, São Paulo, Brazil, that currently uses eucalyptus firewood as fuel to generate water vapour used in silk fiber production. In the studied fuels utilization system energy consumption structure development, we considered energy input in Megajoule (MJ) by type, source and form involved in several firewood use technical itinerary operations, as well as in woodshaving use technical itinerary operations. From these fuels utilization built structure, we performed a firewood- and woodshaving-generated energy input comparative analysis, in Megajoule/hour (MJ.h-1), to produce 2.968,80 kg.h-1 of vapour, which is the boiler average production, during the following years: 2004, 2005, and 2006. The energy analysis results revealed that to replace eucalyptus firewood with woodshaving is something possible in the boiler, reducing total energy consumption approximately by 21%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to build and validate a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) to apply a spray solutions containing water plus a food dye (Blue FDC) at 0,6% m v-1 mixed with two adjuvants: a polymer based anti drift formulation at 0,06% m v-1 and a sodium lauryl ether sulfate based surfactant at 0,2% v v-1. After a 10-second application the drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The wind tunnel had low levels of turbulence and high repeatability of the data, which means that the flow was uniform and able to be used for carrying out measures to estimate drift. The validation results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk potential under those spray technologies. The use of an adjuvant based on a polymer reduced the amount of drift from the nozzle compared to the surfactant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of the addition of different surfactants in physical and chemical properties of spray solutions, droplets spectra and drift potential on agricultural spraying. The surfactants and concentrations (v v-1) were: Haiten (0.1%), Antideriva and Intec (0.05% and 0.1%). The following characteristics were analyzed: surface tension, viscosity, density and electric conductivity. The droplet size spectrum was determined by a laser particle analyzer (Mastersizer S®, version 2.15) including measurements of volume medium diameter (VMD), the percent of droplets below 50 and 100 μm (V50 e V100) and index span. In order to estimate the drift potential, a series of wind tunnel tests were performed with a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) used to apply the spray solutions containing water, the adjuvants and a food color dye (Brilliant blue FD & C no 1) at 0,6% m v-1. The drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The results showed that the addition of adjuvants changed physical and chemical properties of spray solutions in different magnitudes according to the surfactant. Surfactants changed the droplet spectrum and drift potential, indicating that higher VMD and smaller V100 induced higher percentage of drift.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes the occurrence of iatrogenic hydronephrosis in left kidney with compression of the abdominal aorta in persian cat and paralysis of hind limbs. The animal had slight dehydration, pale mucous membranes, cold extremities and cyanotic, absence of bilateral femoral artery pulse, and absence of superficial and deep pain, and presence of a mass of firm consistency with six centimeters in diameter, on abdominal palpation. Performed exploratory celiotomy, there was increased left kidney compressing the abdominal aorta and dilation of the cranial left ureter attached to the uterine horn by means of ligation with nonabsorbable. After nephrectomy, it was observed the restoration of local circulation. The animal died after eight hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS: A prospective cohort study. RESULTS: Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO(2) level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 - 19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II >= 34, an inspiratory positive airway pressure level >= 15 cmH2O and pH<7.40. CONCLUSION: The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II >= 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to study the morphology and biometry of the infraorbital foramen (FIO), variations in its shape, size and number as well as to obtain measurements of its location. 60 dry skulls were analyzed. The test of Qui-quadrant and the T Test were used in measurements with a 5% significance. On the right side, the FIO was measured at a distance of 6.49(+/- 1.68) mm from the lower, 39.65(+/- 3) mm from the upper, 17.7(+/- 2.97) mm from the medial and 20.46(+/- 2.9) mm from the lateral margin of the orbit; its pear-shaped opening distance was 13.67(+/- 2.17) mm. On the left side, the distance of the FIO to the lower margin of the orbit was 6.52(+/- 1.82) mm; to the upper margin was 39.9(+/- 2.62) mm and to the lateral and medial margin were 17.93(+/- 2.58) mm and 21.12(+/- 3) mm, respectively; its distance to the pear-shaped opening was 14.26(+/- 1.83) mm. It was found predominately in an oval shape, in 39 (65%) of the skulls, on both sides. Accessory foramens were present in 11 samples on the right and in 15 samples on the left side. The FIO was most frequently found on the side of, or laterally to the sagittal plane that passes through the middle of the supraorbital foramen/incisures, in 38 skulls (63.3%) on the right side and in 45 skulls (75%) on the left and middle to the zigomatic-maxillary suture, in 41 skulls (68.3%) on right and in 42 skulls (70%) on the left side, besides being most frequently found in a region between the first and second premolars, in 22 skulls (36.7%) on the right side and in 17 skulls (28.3%) on the left.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The benefits of higher positive end expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS) have been modest, but few studies have fully tested the "open-lung hypothesis". This hypothesis states that most of the collapsed lung tissue observed in ARDS can be reversed at an acceptable clinical cost, potentially resulting in better lung protection, but requiring more intensive maneuvers. The short-/middle-term efficacy of a maximum recruitment strategy (MRS) was recently described in a small physiological study. The present study extends those results, describing a case-series of non-selected patients with early, severe ARDS submitted to MRS and followed until hospital discharge or death. Methods: MRS guided by thoracic computed tomography (CT) included two parts: a recruitment phase to calculate opening pressures (incremental steps under pressure-controlled ventilation up to maximum inspiratory pressures of 60 cmH(2)O, at constant driving-pressures of 15 cmH(2)O); and a PEEP titration phase (decremental PEEP steps from 25 to 10 cmH2O) used to estimate the minimum PEEP to keep lungs open. During all steps, we calculated the size of the non-aerated (-100 to +100 HU) compartment and the recruitability of the lungs (the percent mass of collapsed tissue re-aerated from baseline to maximum PEEP). Results: A total of 51 severe ARDS patients, with a mean age of 50.7 years (84% primary ARDS) was studied. The opening plateau-pressure was 59.6 (+/- 5.9 cmH(2)O), and the mean PEEP titrated after MRS was 24.6 (+/- 2.9 cmH(2)O). Mean PaO2/FiO(2) ratio increased from 125 (+/- 43) to 300 (+/- 103; P < 0.0001) after MRS and was sustained above 300 throughout seven days. Non-aerated parenchyma decreased significantly from 53.6% (interquartile range (IQR): 42.5 to 62.4) to 12.7% (IQR: 4.9 to 24.2) (P < 0.0001) after MRS. The potentially recruitable lung was estimated at 45% (IQR: 25 to 53). We did not observe major barotrauma or significant clinical complications associated with the maneuver. Conclusions: MRS could efficiently reverse hypoxemia and most of the collapsed lung tissue during the course of ARDS, compatible with a high lung recruitability in non-selected patients with early, severe ARDS. This strategy should be tested in a prospective randomized clinical trial.