986 resultados para Ferritin-Reference value


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to provide a comparative analysis of pork value chains in Catalonia, Spain and Manitoba, Canada. Intensive hog production models were implemented in Catalonia in the 1960s as a result of agriculture crises and fostered by feedstuffs factories. The expansion of the hog sector in Manitoba is more recent (in the 1990s) and brought about in large part by the opening of the Maple Leaf Meats processing plant in Brandon, Manitoba. This plant is capable of processing 90,000 hogs per week. Both hog production models ‐ the ‘older’ one in Catalonia (Spain) and the ‘newer’ in Manitoba‐ have been, until recently, examples of success. Inventories and production have been increasing substantially and both regions have proven to have great export potential. Recently, however, tensions have been developing with the hog production models of both regions, particularly as they relate to environmental concerns. The purpose of the paper is to compare the value chains with respect to their origins (e.g. supply a growing demand for pork, ensure farm profitability) and present states (e.g. environmental concerns, profitability). Keywords: pork value chain, hog farms, agri‐food studies. JEL: Q10, Q13, O57

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor necrosis factor (TNF) alpha, interleukins (IL) 2, 4, 6, and 10, and IgG oligoclonal bands (IgG OB) in vitro production was assessed, after whole-blood stimulation with lipopolysaccharide or concanavalin A, in 61 patients presenting with relapsing-remitting, relapsing-progressive, or chronic progressive multiple sclerosis. Multiple sclerosis patients were receiving no treatment or azathioprine (AZA), cyclosporin, cyclophosphamide, subcutaneous interferon (IFN) beta 1 a, or corticosteroids (CST). Statistical correlations significantly showed that: (a) AZA lowers TNF-alpha (P = 0.002) and increases IL-4 production (P = 0.0024), and IFN-beta 1 a increases TNF-alpha and decreases IL-4 levels; (b) CST has a negative effect on TNF-alpha, IL-6, and IL-4 synthesis; and (c) AZA, IFN-beta 1 a, and CST diminish IgG OB synthesis (P = 0.001). Although our study of the dynamics of TNF-alpha, IL-2, IL-4, IL-6, and IL-10 in vitro production generally found no statistically significant correlations (partly explained by the limited number of values in the various groups), IL-6 was shown to drop during the periods surrounding relapse (P = 0.05) in the absence of treatment, while TNF-alpha (P = 0.04) and IL-6 (P < 0.05) dropped before exacerbation in the presence of AZA. In vitro production of TNF-alpha was closely and positively correlated with that of IL-6, independently of clinical features. The enhanced production of IL-10 detected before or at relapse with AZA and IFN-beta 1 a (trends) may interfere with initiation of the immune reaction and with the development of new CNS lesions. Some discrepancies with previously published results stress the difficulties in studying the state of stimulation of different populations of leukocytes by using a variety of in vitro stimuli and in establishing a correlation between mRNA studies and the amount of final or active protein produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In April 2000, Deloitte & Touche in conjunction with the York Health Economics Consortium were chosen by The Department of Health & Children to carry out an examination of the health services over the past ten years Download the Report here

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angiogenesis inhibitors have been developed to block tumour angiogenesis and target vascular endothelial cells. While some of them have already been approved by the health authorities and are successfully integrated into patient care, many others are still under development, and the clinical value of this approach has to be established. OBJECTIVES: To assess the efficacy and toxicity of targeted anti-angiogenic therapies, in addition to chemotherapy, in patients with metastatic colorectal cancer. Primary endpoints are both progression-free and overall survival. Response rates, toxicity and secondary resectability were secondary endpoints. Comparisons were first-line chemotherapy in combination with angiogenesis inhibitor, to the same chemotherapy without angiogenesis inhibitor; and second-line chemotherapy, to the same chemotherapy without angiogenesis inhibitor. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials, MEDLINE, as well as proceedings from ECCO, ESMO and ASCO until November 2008. In addition, reference lists from trials were scanned, experts in the field and drug manufacturers were contacted to obtain further information. SELECTION CRITERIA: Randomized controlled trials on targeted anti-angiogenic drugs in metastatic colorectal cancer (MCRC). DATA COLLECTION AND ANALYSIS: Data collection and analysis was performed, according to a previously published protocol. Because individual patient data was not provided, aggregate data had to be used for the analysis. Summary statistics for the primary endpoints were hazard ratios (HR's) and their 95% confidence intervals. MAIN RESULTS: At present, eligible first line trials for this meta-analysis were available for bevacizumab (5 trials including 3101 patients) and vatalanib (1 trial which included 1168 patients). The overall HR s for PFS (0.61, 95% CI 0.45 - 0.83) and OS (0.81, 95% 0.73 - 0.90) for the comparison of first-line chemotherapy, with or without bevacizumab, confirms significant benefits in favour of the patients treated with bevacizumab. However, the effect on PFS shows significant heterogeneity. For second-line chemotherapy, with or without bevacizumab, a benefit in both PFS (HR 0.61, 95% CI 0.51 - 0.73) and OS (HR 0.75, 95% CI 0.63-0.89) was demonstrated in a single, randomized trial. While differences in treatment-related deaths and 60-day mortality were not significant, higher incidences in grade III/IV hypertension, arterial thrombembolic events and gastrointestinal perforations were observed in the patients treated with bevacizumab. For valatanib, currently available data showed a non-significant benefit in PFS and OS. AUTHORS' CONCLUSIONS: The addition of bevacizumab to chemotherapy of metastatic colorectal cancer prolongs both PFS and OS in first-and second-line therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the prevalence of non-tuberculous mycobacteria (NTM) isolates at University Hospital, Reference Center for Aids in Rio de Janeiro, Brazil, during one year. We used standard biochemical tests for species identification and IS1245 PCR amplification was applied as a Mycobacterium avium specific identification marker. Four hundred and four specimens from 233 patients yielded acid-fast bacilli growth. M. tuberculosis was identified in 85% of the patients and NTM in 15%. NTM disseminated infection was a common event correlated with human immunodeficiency virus (HIV) infected patients and only in HIV negative patients the source of NTM was non sterile site. M. avium complex (MAC) was biochemically identified in 57.8% (49/83) of NTM isolates, most of them from sterile sites (75.5%), and in 94% (46/49) the IS 1245 marker specific for M. avium was present. Twenty NTM strains showed a MAC biochemical pattern with the exception of a urease-positive (99% of MAC are urease-negative), however IS1245 was detected in 96% of the strains leading to their identification as M. avium. In this group differences in NTM source was not significant. The second most frequently isolated NTM was identified as M. scrofulaceum (7.2%), followed by M. terrae (3.6%), M. gordonae (2.4%), M. chelonae (1.2%), M. fortuitum (1.2%) and one strain which could not be identified. All were IS1245 negative except for one strain identified as M. scrofulaceum. It is interesting to note that non-sterile sites were the major source of these isolates (92.8%). Our finding indicated that M. avium is still the major atypical species among in the MAC isolates recovered from Brazilian Aids patients without highty active antiretroviral therapy schema. Some discrepancies were seen between the identification methods and further investigations must be done to better characterize NTM isolates using other phenotypic and genotypic methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La localització d'òrgans és un tòpic important en l'àmbit de la imatge mèdica per l'ajuda del tractament i diagnosi del càncer. Un exemple es pot trobar en la cal•libració de models farmacoquinètics. Aquesta pot ésser realitzada utilitzant un teixit de referència, on, per exemple en imatges de ressonància magnètica de pit, una correcta segmentació del múscul pectoral és necessària per a la detecció de signes de malignitat. Els mètodes de segmentació basat en atlas han estat altament avaluats en imatge de ressonància magnètica de cervell, obtenint resultats satisfactoris. En aquest projecte, en col•laboració amb el el Diagnostic Image Analysis Group de la Radboud University Nijmegen Medical Centre i la supervisió del Dr. N.Karssemeijer, es presenta la primera aproximació d'un mètode de segmentació basat en atlas per segmentar els diferents teixits visibles en imatges de ressonància magnètica (T1) del pit femení. L'atlas consisteix en 5 estructures (teixit greixòs, teixit dens, cor, pulmons i múscul pectoral) i ha estat utilitzat en un algorisme de segmentació Bayesià per tal de delinear les esmentades estructures. A més a més, s'ha dut a terme una comparació entre un mètode de registre global i un de local, utilitzats tant en la construcció de l'atlas com en la fase de segmentació, essent el primer el que ha presentat millors resultats en termes d'eficiència i precisió. Per a l'avaluació, s'ha dut a terme una comparació visual i numèrica entre les segmentacions obtingudes i les realitzades manualment pels experts col•laboradors. Pel que fa a la numèrica, s'ha emprat el coeficient de similitud de Dice ( mesura que dóna valors entre 0 i 1, on 0 significa no similitud i 1 similitud màxima) i s'ha obtingut una mitjana general de 0.8. Aquest resultat confirma la validesa del mètode presentat per a la segmentació d'imatges de ressonància magnètica del pit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Value for Money Report – The Efficiency and Effectiveness of Long-Stay Residential Care for Adults within the Mental Health Services Executive Summary and Contents PDF 164kb Chapters 1 and 2 – Introduction and Service Objectives PDF 504kb Chapter 3 plus annexes – Service Effectiveness and Efficiency PDF 3.7mb Chapter 4 – Service Resources PDF 2.4mb Chapters 5, 6 and 7 – Future Funding and Alternative Approaches, Key Performance Indicators, Conclusions and Recommendations PDF 2.4mb Appendices 1 to 6

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proposed Model for Reference Pricing and Generic Substitution Click here to download PDF 137KB   Click here to download the Frequently Asked Questions PDF 23KB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to inform the work of the Value for Money (VFM) Review of Disability Services, an Expert Reference Group was established comprising representatives from the DoH and HSE, disability agencies and representative groups. The Group conducted an extensive policy review and its Report is here. In essence, it proposes a reframing of disability services towards a model of individualised supports, underpinned by mainstreaming of all public services.   Click here to download PDF 1.67MB  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Review is an evaluation of the efficiency and effectiveness of the HSE-funded statutory and non-statutory disability services in Ireland. It was conducted by the Department of Health and the HSE under the auspices of the Governmentâ?Ts programme of Value for Money Reviews for 2009-2011. It makes a range of recommendations about how these services should be structured. www.dohc.ie/press/releases/2012/20120720.html Click here to download PDF 3.7mb Value for Money and Policy Review of the Disability Services Programme – Recommendation PDF 205kb Value for Money and Policy Review of the Disability Services Programme – Questions & Answers PDF 44kb Value for Money and Policy Review of the Disability Services Programme – Questions & Answers PDF 151kb  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The National Implementation Framework describes how the recommendations from the Value for Money (VFM) and Policy Review of the Disability Services Programme will be translated into concrete actions. It assigns responsibilities for those actions, and specifies timelines for their completion. It also identifies priorities and key performance indicators. The Framework describes how these reforms can be achieved in a planned, timely and cost effective manner. Click here to download (PDF 876KB)