913 resultados para Eye Movement
Resumo:
OPINION STATEMENT: The diagnosis and appropriate treatment of hyperkinetic movement disorders require a work up of potentially reversible metabolic, infectious and structural disorders as well as side effects of current medication. In pharmacoresistant movement disorders with a disabling impact on quality of life, deep brain stimulation (DBS) should be considered. At different targets, DBS has become an established therapy for Parkinson's disease (GPi-STN), tremor (VIM) and primary dystonia (GPi) with reasonable perioperative risks and side effects, established guidelines and some clinical and radiological predictive factors. In contrast, for other hyperkinetic movement disorders, including secondary dystonia, Gilles de la Tourette, chorea and ballism, only few data are available. Definite targets are not well defined, and reported results are of less magnitude than those of the recognized indications. In this expanding therapeutical field without worked out recommendations, an individual approach is needed with DBS indication assessment only after rigorous multidisciplinary scrutiny, restricted to expert centres.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.
Resumo:
Covert spatial attention produces biases in perceptual and neural responses in the absence of overt orienting movements. The neural mechanism that gives rise to these effects is poorly understood. Here we report the relation between fixational eye movements, namely eye vergence, and covert attention. Visual stimuli modulate the angle of eye vergence as a function of their ability to capture attention. This illustrates the relation between eye vergence and bottom-up attention. In visual and auditory cue/no-cue paradigms, the angle of vergence is greater in the cue condition than in the no-cue condition. This shows a top-down attention component. In conclusion, observations reveal a close link between covert attention and modulation in eye vergence during eye fixation. Our study suggests a basis for the use of eye vergence as a tool for measuring attention and may provide new insights into attention and perceptual disorders.
Resumo:
In the context of the evidence-based practices movement, the emphasis on computing effect sizes and combining them via meta-analysis does not preclude the demonstration of functional relations. For the latter aim, we propose to augment the visual analysis to add consistency to the decisions made on the existence of a functional relation without losing sight of the need for a methodological evaluation of what stimuli and reinforcement or punishment are used to control the behavior. Four options for quantification are reviewed, illustrated, and tested with simulated data. These quantifications include comparing the projected baseline with the actual treatment measurements, on the basis of either parametric or nonparametric statistics. The simulated data used to test the quantifications include nine data patterns in terms of the presence and type of effect and comprising ABAB and multiple baseline designs. Although none of the techniques is completely flawless in terms of detecting a functional relation only when it is present but not when it is absent, an option based on projecting split-middle trend and considering data variability as in exploratory data analysis proves to be the best performer for most data patterns. We suggest that the information on whether a functional relation has been demonstrated should be included in meta-analyses. It is also possible to use as a weight the inverse of the data variability measure used in the quantification for assessing the functional relation. We offer an easy to use code for open-source software for implementing some of the quantifications.
Resumo:
We present here the first part of the literature review regarding our study object, the Open Device Labs. The research on ODLs emerges from the observation of worldwide non-profit movement, which, through mutual collaboration, information and devices sharing, proposes a final improvement on user’s experience with the web and app.
The art of "touching the kantele" : aspects of the effect of posture and movement in kantele playing
Resumo:
Diabetes is a rapidly increasing worldwide problem which is characterised by defective metabolism of glucose that causes long-term dysfunction and failure of various organs. The most common complication of diabetes is diabetic retinopathy (DR), which is one of the primary causes of blindness and visual impairment in adults. The rapid increase of diabetes pushes the limits of the current DR screening capabilities for which the digital imaging of the eye fundus (retinal imaging), and automatic or semi-automatic image analysis algorithms provide a potential solution. In this work, the use of colour in the detection of diabetic retinopathy is statistically studied using a supervised algorithm based on one-class classification and Gaussian mixture model estimation. The presented algorithm distinguishes a certain diabetic lesion type from all other possible objects in eye fundus images by only estimating the probability density function of that certain lesion type. For the training and ground truth estimation, the algorithm combines manual annotations of several experts for which the best practices were experimentally selected. By assessing the algorithm’s performance while conducting experiments with the colour space selection, both illuminance and colour correction, and background class information, the use of colour in the detection of diabetic retinopathy was quantitatively evaluated. Another contribution of this work is the benchmarking framework for eye fundus image analysis algorithms needed for the development of the automatic DR detection algorithms. The benchmarking framework provides guidelines on how to construct a benchmarking database that comprises true patient images, ground truth, and an evaluation protocol. The evaluation is based on the standard receiver operating characteristics analysis and it follows the medical practice in the decision making providing protocols for image- and pixel-based evaluations. During the work, two public medical image databases with ground truth were published: DIARETDB0 and DIARETDB1. The framework, DR databases and the final algorithm, are made public in the web to set the baseline results for automatic detection of diabetic retinopathy. Although deviating from the general context of the thesis, a simple and effective optic disc localisation method is presented. The optic disc localisation is discussed, since normal eye fundus structures are fundamental in the characterisation of DR.
Resumo:
Då man rör sig i New York eller Jerusalem är det inte ovanligt att man stöter på judiska "missionärer" - ett fenomen som annars är ovanligt inom judendomen - och får ett traktat i sin hand som säger "Moshiach är här" eller "Welcome Moshiach". Det är den ultra-ortodoxa rörelsen Chabad-Lubavitch som har blivit känd för sitt utåtriktade missionsarbete och för att ha proklamerat sin ledare, Rabbi Schneerson som messias. Trots att han har varit död sedan 1994 och man från judiskt håll säger att en messias inte kan dö, lever förväntningarna på Rabbi Schneerson kvar inom rörelsen. Den akademiska forskningen har gjort gällande att denna messiastro, som tar sig ett så aktivt uttryck, är en produkt av den existentiella hopplöshet som lägrade sig över det judiska samfundet i och med Förintelsen, därför att väntan på messias omedelbara ankomst ingav livshopp. Dessutom har forskningen från ett religionssociologiskt perspektiv frågat hur en religiös rörelse överlever en så stor besvikelse som att ens ledare inte uppfyller de profetior som talats ut. Avhandlingen "We Want Moshiach NOW!" ifrågasätter den tidigare forskningen genom att påvisa de starka messianska förväntningar som fanns redan på 1700-talet vid rörelsens tillkomst. Avhandlingen tar upp vilka förväntningar som framkommer i det litterära verket "Tanja", författad av rörelsens grundare, och jämför dem med den moderna litteraturen. I "Tanja" ges även förklaringsmodeller till varför en person som man trodde var messias inte är det. Avhandlingens tes är att forskningen inte har beaktat utsagorna i "Tanja" tillräckligt mycket då man försökt förstå den samtida messiastron och de uttryck den tar.
Resumo:
RESUMO A tomada de decisão é uma das dimensões essenciais da formação do profissional da saúde, como mencionado nas atuais Diretrizes Curriculares Nacionais do Curso de Graduação em Medicina. O processo decisório, no âmbito da saúde, envolve diferentes aspectos, incluindo os elementos (bio)éticos. Nesse sentido, pesquisas que investiguem a tomada de decisão em (bio)ética poderão elucidar passos ainda não completamente esclarecidos, permitindo uma construção mais efetiva das competências em (bio)ética, na graduação e na pós-graduação. Diante desta perspectiva, o objetivo deste estudo é explorar possibilidades de uso do Mobile Eye Tracking para o estudo do papel da atenção visual – durante a exibição de filmes de cinema – no processo decisório em (bio)ética.