961 resultados para Electric power distribution systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors present an offline switching power supply with multiple isolated outputs and unity power factor with the use of only one power processing stage, based on the DC-DC SEPIC (single ended primary inductance converter) modulated by variable hysteresis current control. The principle of operation, the theoretical analysis, the design procedure, an example, and simulation results are presented. A laboratory prototype, rated at 160 W, operating at a maximum switching frequency of 100 kHz, with isolated outputs rated at +5 V/15 A -5 V/1 A, +12 V/6 A and -12 V/1 A, has been built given an input power factor near unity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Teaching a course of special electric loads in a continuing education program to power engineers is a difficult task because they are not familiarized with switching topology circuits. Normally, in a typical program, many hours are dedicated to explain the thyristors switching sequence and to draw the converter currents and terminal voltages waveforms for different operative conditions. This work presents teaching support software in order to optimize the time spent in this task and, mainly to benefit the assimilation of the proposed subjects, studying the static converter under different non-ideal operative conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a methodology for solving a set of linear sparse equations on vector computers. The new methodology is able to exploit the matrix and vector sparsities. The implementation was made on a CRAY Y-MP 2E/232 computer and the results were taken from electric power systems with 118, 320, 725 and 1729 buses. The proposed methodology was compared with three previous methods and the results show the superior performance of the new one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents an algorithm for the security control of electric power systems using control actions like generation reallocation, determined by sensitivity analysis (linearized model) and optimization by neural networks. The model is developed taking into account the dynamic network aspects. The preventive control methodology is developed by means of sensitivity analysis of the security margin related with the mechanical power of the system synchronous machines. The reallocation power in each machine is determined using neural networks. The neural network used in this work is of Hopfield type. These networks are dedicated electric circuits which simulate the constraint set and the objective function of an optimization problem. The advantage of using these networks is the higher speed in getting the solutions when compared to conventional optimization algorithms due to the great convergence rate of the process and the facility of the method parallelization. Then, the objectives are: formulate and investigate these networks implementations in determining. The generation reallocation in digital computers. Aiming to illustrate the proposed methodology an application considering a multi-machine system is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Substitution of fuzzy logic control in an electrical system normally controlled by proportional-integral frequency was studied and analyzed. A linear model of an electrical system, the concepts which govern the theory of fuzzy logic, and the application of this theory to systems control, are briefly presented. The methodology of fuzzy logic was then applied to develop a model for an electrical energy system. The results of the simulation demonstrated that fuzzy logic control eliminated the area frequency error and permitted that only the area experiencing an increase in charge responds to this variation. Based on the results, it is concluded that control based on fuzzy logic is simple, is easy to maintain, is of low cost, and can be used to substitute traditional velocity controllers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A model for preventive control in electrical systems is presented, taking into account the dynamic aspects of the network. Among these aspects, the effects provoked by perturbations which cause oscillations in synchronous machine angles (transient stability), such as electric equipment outages and short circuits, are presented. The energy function is used to measure the stability of the system using a procedure defined as the security margin. The control actions employed are load shedding and generation reallocation. An application of the methodology to a system located in southern Brazil, which is composed of 10 synchronous machines, 45 busses, and 72 transmission lines. The results confirm the theoretical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Technical and economic feasibility of using natural gas as a non-polluting energy source was studied. Conversion of electric ovens to gas-fired ovens for the preparation of aluminum plates for laminations was used as an example of this application. Four cases were evaluated for the use of heat derived from residual gases following combustion of the natural gas. Additionally, two possibilities are included for the use of systems of co-generation; one using an internal combustion engine, and second using a gas turbine. Results suggested that it was technically and economically feasible to convert the electric ovens considered to natural gas-operated ovens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Network reconfiguration in distribution systems can be carried out by changing the status of sectionalizing switches and it is usually done for loss minimization and load balancing. In this paper it is presented an heuristic algorithm that accomplishes network reconfiguration for operation planning in order to obtain a configuration set whose configurations have the smallest active losses on its feeders. To obtain the configurations, it is used an approached radial load flow method and an heuristic proceeding based on maximum limit of voltage drop on feeders. Results are presented for three hypothetical systems largely known whose data are available in literature and a real system with 135 busses. In addition, it is used a fast and robust load flow which decreases the computational effort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel isolated electronic ballast for multiple fluorescent lamps, featuring high power-factor, and high efficiency. Two stages compose this new electronic ballast, namely, a new voltage step-down isolated Sepic rectifier, and a classical resonant Half-Bridge inverter. The new isolated Sepic rectifier is obtained from a Zero-Current-Switching (ZCS) Pulse-Width-Modulated (PWM) soft-commutation cell. The average-current control technique is used in this preregulator stage in order to provide low phase displacement and low Total-Harmonic-Distortion (THD) at input current, resulting in high power-factor, and attending properly IEC 61000-3-2 standards. The resonant Half-Bridge inverter performs Zero-Voltage-Switching (ZVS), providing conditions for the obtaining of overall high efficiency. It is developed a design example for the new isolated electronic ballast rated at 200W output power, 220Vrms input voltage, 115Vdc dc link voltage, with rectifier and inverter stages operating at 50kHz. Finally, experimental results are presented in order to verify the developed analysis. The THD at input current is equal to 5.25%, for an input voltage THD equal to 1.63%, and the measured overall efficiency is about 88.25%, at rated load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the Benders decomposition technique and Branch and Bound algorithm used in the reactive power planning in electric energy systems. The Benders decomposition separates the planning problem into two subproblems: an investment subproblem (master) and the operation subproblem (slave), which are solved alternately. The operation subproblem is solved using a successive linear programming (SLP) algorithm while the investment subproblem, which is an integer linear programming (ILP) problem with discrete variables, is resolved using a Branch and Bound algorithm especially developed to resolve this type of problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An overview is given on the possibility of controlling the status of circuit breakers (CB) in a substations with the use of a knowledge base that relates some of the operation magnitudes, mixing status variables with time variables and fuzzy sets. It is shown that even when all the magnitudes to be controlled cannot be included in the analysis, it is possible to control the desired status while supervising some important magnitudes as the voltage, power factor, and harmonic distortion, as well as the present status.