835 resultados para Edentulous jaw


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this randomized, cross-over in situ study was to determine the effects of 4 chewing gums on artificial caries-like subsurface lesions. Two chewing gums (1 with zinc citrate and 1 without) contained dicalcium phosphate (3.9%), calcium gluconate (1.8%) and calcium lactate (0.45%), 1 chewing gum contained casein phosphopeptide-amorphous calcium phosphate nanocomplexes (0.7%), and another one contained no calcium. Fifteen subjects without current caries activity (7 male, 8 female; mean age: 27.5 +/- 2.5 years) wore removable buccal appliances in the lower jaw with 4 bovine enamel slabs with subsurface lesions. The appliances were inserted immediately before gum chewing for 20 min and then retained for an additional 20 min. This was performed 4 times per day. Every subject chewed 4 different chewing gums over 4 periods of 14 days each. During a fifth period (control) the subjects only wore the appliances without chewing gum. At completion of each period the enamel slabs were embedded, sectioned and subjected to transversal microradiography. With regard to change of mineral loss and of lesion depth no significant differences could be found between chewing gums containing calcium and calcium-free chewing gums. Moreover, the chewing gum groups and the control group did not differ significantly if adjustments were made for baseline values (p > 0.05; ANCOVA). Under the conditions of the present study it may be concluded that the use of chewing gum offers no additional remineralizing benefit to buccal tooth surfaces, even if the chewing gum contains calcium compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Peri-implantitis is associated with the presence of submarginal plaque, soft-tissue inflammation and advanced breakdown of the supporting bone. The progression of peri-implantitis following varying periods of continuing plaque accumulation has been studied in animal models. OBJECTIVE: The aim of the current experiment was to study the progression of peri-implantitis around implants with different surface roughness. MATERIAL AND METHODS: In five beagle dogs, three implants with either a sandblasted acid-etched surface (SLA) or a polished surface (P) were installed bilaterally in the edentulous premolar regions. After 3 months on a plaque control regimen, experimental peri-implantitis was induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. After this 4-month period, ligatures were removed and plaque accumulation was continued for an additional 5 months. Radiographs of all implant sites were obtained before and after 'active' experimental peri-implantitis as well as at the end of the experiment. Biopsies were harvested and the tissue samples were prepared for light microscopy. The sections were used for histometric and morphometric examinations. RESULTS: The radiographic examinations indicated that similar amounts of bone loss occurred at SLA and P sites during the active breakdown period, while the progression of bone loss was larger at SLA than at polished sites following ligature removal. The histological examination revealed that both bone loss and the size of the inflammatory lesion in the connective tissue were larger in SLA than in polished implant sites. The area of plaque was also larger at implants with an SLA surface than at implants with a polished surface. CONCLUSION: It is suggested that the progression of peri-implantitis, if left untreated, is more pronounced at implants with a moderately rough surface than at implants with a polished surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The surgical treatment of oral cancer results in functional and aesthetical impairments. Patients' quality of life is considerably impaired by oral symptoms resulting from therapy of oral cancer. In many cases the inevitable resection of the tumor, as well as the adjuvant radiochemotherapy will cause the destruction of physiologically and anatomically important structures. One focus of research was the specific rehabilitation of dental loss by functional dentures. Another was the course of 19 impairments (comprehension of speech for unknown others, comprehension of speech for familiar others, eating/swallowing, mobility of the tongue, opening range of the mouth, mobility of lower jaw, mobility of neck, mobility of arms and shoulders, sense of taste, sense of smell, appearance, strength, appetite, respiration, pain, swelling, xerostomia, halitosis). METHODS: Commissioned by the German, Austrian and Swiss cooperative group on tumors of the maxillofacial region (DOSAK), data were collected in 3.894 questionnaires at 43 hospitals in Germany, Austria and Switzerland. The catalogue comprised 147 items in 9 chapters. At the end of the enquiry, 1.761 anonymous questionnaires were returned by 38 hospitals. 1.652 of these could be evaluated regarding the question. RESULTS: The sum score of the 19 impairments was highly increased immediately after the operation and recovered over the next 6 months, without, however, reaching the pre-surgery level. Of 1.652 patients, only 35% did not lose any teeth during therapy. 23% lost up to 5, 17% up to 10 teeth. A quarter of the patients lost more than 10 teeth. The more teeth were lost, the greater the decline of quality of life (p < or = 0.001), although this could be allayed by the functionality of the dentures (p < or = 0.001). There is a reciprocal dependence between the functionality of dental prosthetics and impairment by eating/swallowing (p < or = 0.001). CONCLUSIONS: Patients' quality of life after radical surgery of a carcinoma of the oral cavity depends not only on the functionality of dentures and the specificity of rehabilitation, but also from the initial findings, the extent and location of the resection, the chosen therapy, the general circumstances of the patient's life as well as their strategies of coping. These factors, however, unlike those of functionality of dental prosthesis and rehabilitation, are not modifiable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation dose delivered from the SCANORA radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest. METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading. RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing. CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the study was to analyse longitudinal vertical facial and dentoalveolar changes using panoramic radiographs (PRs) and to compare the results with measurements on lateral cephalometric radiographs (LCRs) in order to determine whether, under certain circumstances, the radiation dose for a patient may be reduced by taking only a PR instead of a PR and a LCR. Pre- and post-treatment PRs and LCRs of 30 (15 females and 15 males) orthodontically treated adolescents (mean age pre-treatment 10.9 years, post-treatment 13.4 years) were analysed using Pearson's correlation coefficients and gender differences using Fisher's z-transformation. The results revealed that most variables exhibited larger absolute values on PRs than on LCRs. Comparison of dentoskeletal morphology between the LCRs and the PRs revealed moderate to high, mostly statistically significant, interrelations both before and after orthodontic treatment. The lowest correlations were found for the maxillary jaw base angle (NL/H; r= 0.35***) and the highest for the gonial angle (ML/RL; r = 0.90***). However, when assessing the combined growth and treatment changes from before to after treatment, only weak to moderate, not statistically significant, interrelations were found between LCRs and PRs. Anterior face height (AFH; r = 0.43***), the mandibular plane angle (ML/H; r = 0.06*), and the distance of the incisal tip of the most extruded mandibular incisor to the ML-line (ii-ML; r = -0.21*) were the only statistically significant parameters. The average group differences for growth and treatment changes, however, were small for most parameters. Analysis of vertical facial and dentoalveolar parameters on PRs delivers a moderate approximation to the situation depicted on LCRs. However, PRs cannot be recommended for the analysis of individual longitudinal changes in vertical facial and dentoalveolar parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The Nobel Direct implant (Nobel Biocare AB, Göteborg, Sweden) was developed to minimize marginal bone resorption and to result in "soft tissue integration" for an optimized aesthetic outcome. However, conflicting results have been presented in the literature. The aim of this present study was to evaluate the clinical and microbiologic outcomes of Nobel Direct implants. MATERIALS AND METHODS: Ten partially edentulous subjects without evidence of active periodontitis (mean age 55 years) received 12 Nobel Direct implants. Implants were loaded with single crowns after a healing period of 3 to 6 months. Treatment outcomes were assessed at month 24. Routine clinical assessments, intraoral radiographs, and microbiologic samplings were made. Histologic analysis of one failing implant and chemical spectroscopy around three unused implants was performed. Paired Wilcoxon signed-rank test was used for the evaluation of bone loss; otherwise, descriptive analysis was performed. RESULTS: Implants were functionally loaded after 3 to 6 months. At 2 years, the mean bone loss of remaining implants was 2.0 mm (SD +/- 1.1 mm; range: 0.0-3.4 mm). Three out of 12 implants with an early mean bone loss >3 mm were lost. The surviving implants showed increasing bone loss between 6 and 24 months (p = .028). Only 3 out of the 12 implants were considered successful and showed bone loss of <1.7 mm after 2 years. High rates of pathogens, including Aggregatibacter actinomycetemcomitans, Fusobacterium spp., Porphyromonas gingivalis, Pseudomonas aeruginosa, and Tanerella forsythia, were found. Chemical spectroscopy revealed, despite the normal signals from Ti, O, and C, also peaks of P, F, S, N, and Ca. A normal histologic image of osseointegration was observed in the apical part of the retrieved implant. CONCLUSION: Radiographic evidence and 25% implant failures are indications of a low success rate. High counts and prevalence of significant pathogens were found at surviving implants. Although extensive bone loss had occurred in the coronal part, the apical portion of the implant showed some bone to implant integration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osseointegration of titanium dental implants into the jaw bone, which is required for maintenance of the implant in the jaw, results in ankylosis. Dental implants are therefore very unlike natural teeth, which exhibit significant movement in response to mechanical forces. The ability to generate periodontal ligament (PDL) tissues onto dental implants would better mimic the functional characteristics of natural teeth, and would likely improve implant duration and function. OBJECTIVES: The objective of this study was to investigate the feasibility of bioengineering PDL tissues onto titanium implant surfaces. METHODS: Bilateral maxillary first and second molars of 8-week old rats were extracted and used to generate single cell suspensions of PDL tissues, which were expanded in culture. Immunohistochemistry and RT-PCR were used to identify putative PDL progenitor/stem cell populations and characterize stem cell properties, including self-renewal, multipotency and stem cell maker expression. Cultured rPDL cells were harvested at third passage, seeded onto Matrigel-coated titanium implants (1.75 mm x 1 mm), and placed into healed M1/M2 extraction sites. Non-cell seeded Matrigel-coated titanium implants served as negative controls. Implants were harvested after 8, 12, or 18 weeks. RESULTS: Cultured rPDL cells expressed the mesenchymal stem-cell marker STRO-1. Under defined culture conditions, PDL cells differentiated into adipogenic, neurogenic and osteogenic lineages. While control implants were largely surrounded by alveolar bone, experimental samples exhibited fibrous PDL-like tissues, and perhaps cementum, on the surface of experimental implants. CONCLUSIONS: PDL contains stem cells that can generate cementum/PDL-like tissue in vivo. Transplantation of these cells might hold promise as a therapeutic approach for the bioengineering of PDL tissues onto titanium implant. Further refinement of this method will likely result in improved dental implant strategies for use of autologous PDL tissue regeneration in humans. This research was supported by CIMIT, and NIH/NIDCR grant DE016132 (PCY), and TEACRS (YL).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Various imaging techniques, including conventional radiography and computed tomography, are proposed to localize the mandibular canal prior to implant surgery. The aim of this study is to determine the incidence of altered mental nerve sensation after implant placement in the posterior segment of the mandible when a panoramic radiograph is the only preoperative imaging technique used. MATERIAL AND METHODS: The study included 1527 partially and totally edentulous patients who had consecutively received 2584 implants in the posterior segment of the mandible. Preoperative bone height was evaluated from the top of the alveolar crest to the superior border of the mandibular canal on a standard panoramic radiograph. A graduated implant scale from the implant manufacturer was used and 2 mm were subtracted as a safety margin to determine the length of the implant to be inserted. RESULTS: No permanent sensory disturbances of the inferior alveolar nerve were observed. There were two cases of postoperative paresthesia, representing 2/2584 (0.08%) of implants inserted in the posterior segment of the mandible or 2/1527 (0.13%) of patients. These sensory disturbances were minor, lasted for 3 and 6 weeks and resolved spontaneously. CONCLUSIONS: Panoramic examination can be considered a safe preoperative evaluation procedure for routine posterior mandibular implant placement. Panoramic radiography is a quick, simple, low-cost and low-dose presurgical diagnostic tool. When a safety margin of at least 2 mm above the mandibular canal is respected, panoramic radiography appears to be sufficient to evaluate available bone height prior to insertion of posterior mandibular implants; cross-sectional imaging techniques may not be necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: In alveolar distraction, in cases of severe atrophy in particular, it is often difficult to perform osteotomies in order to make a transport segment in optimal size and shape. Moreover care must be taken, not to damage the closely locating anato- mical structures such as the maxillary sinus, the inferior alveolar nerve, and the roots of the neighboring teeth. For setting ideal osteotomy lines exactly, we have developed a CT-based preoperative planning tool. Methods: 3-dimensional visual reconstruction of the jaw is created from the preoperative CT scans (1.0-mm slice thick- ness). Using the image-processing software Mimics (Materialise, Yokohama, Japan), various procedures of virtual cutting are simulated first to determine optimal osteotomy lines and to design an ideal transport segment. After the computer planning, data from the virtual solid model are transferred to a rapid prototype model, and a guiding splint is made to transfer the planned surgical simulation to the actual surgery. Results: The method was used in a case of severe atrophy of the anterior maxilla. The patient had a large maxillary sinus requir- ing a precise osteotomy in this critical area. Using the splint allowing a 3-dimensional guidance, alveolar osteotomies were easily done to achieve a transport segment in sufficient dimen- sion as planned, and any perforation of the maxillary sinus could be avoided. Finally the alveolar distraction of 10mm has suc- cessfully been performed. Conclusion: The preoperative planning method and the guiding splint described here are useful in problematic cases requiring an extremely precise osteotomy due to lack of bony space.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.