912 resultados para EXTERNAL IRRADIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report produced as part of the Green Logistics project (EPSRC and Department for Transport funded). To what extent do the taxes paid by the light goods vehicles (LGVs) users in Britain cover their allocated infrastructural, environmental and congestion costs? This report is a continuation of a study on the internalisation of the external costs of heavy goods vehicle activity. Research undertaken jointly by the Transport Studies Group at University of Westminster and Logistics Research Centre at Heriot-Watt University has attempted to answer this question using official government transport statistics and monetary valuations for the external costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report produced as part of the Green Logistics project (EPSRC and Department for Transport funded). This report provides estimates of the total external costs of LGV and HGV operations in London. In 2006, total LGV and HGV activity imposed external costs of approximately £1.75-£1.8 billion using low, medium and high emission cost values. About 27 per cent of these costs were internalised by duties and taxes paid by LGV operators, compared with 26% in the case of HGVs. If congestion costs are excluded, taxes and duties paid by LGV operators are estimated to be 155% of LGVs' allocated infrastructural and environmental costs, compared with 85% in the case of HGVs. When using the medium emission cost values, LGVs accounted for 56% of these external costs in London and HGVs for 44%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides estimates of the total external costs of LGV and HGV operations in London. In 2006, total LGV and HGV activity imposed external costs of approximately £1.75-£1.8 billion using low, medium and high emission cost values. About 27 per cent of these costs were internalised by duties and taxes paid by LGV operators, compared with 26% in the case of HGVs. If congestion costs are excluded, taxes and duties paid by LGV operators are estimated to be 155% of LGVs' allocated infrastructural and environmental costs, compared with 85% in the case of HGVs. When using the medium emission cost values, LGVs accounted for 56% of these external costs in London and HGVs for 44%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To what extent do the taxes paid by the light goods vehicles (LGVs) users in Britain cover their allocated infrastructural, environmental and congestion costs? This report is a continuation of a study on the internalisation of the external costs of heavy goods vehicle activity. Research undertaken jointly by the Transport Studies Group at University of Westminster and Logistics Research Centre at Heriot-Watt University has attempted to answer this question using official government transport statistics and monetary valuations for the external costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Accurate placement of an external ventricular drain (EVD) for the treatment of hydrocephalus is of paramount importance for its functionality and in order to minimize morbidity and complications. The aim of this study was to compare two different drain insertion assistance tools with the traditional free-hand anatomical landmark method, and to measure efficacy, safety and precision. METHODS: Ten cadaver heads were prepared by opening large bone windows centered on Kocher's points on both sides. Nineteen physicians, divided in two groups (trainees and board certified neurosurgeons) performed EVD insertions. The target for the ventricular drain tip was the ipsilateral foramen of Monro. Each participant inserted the external ventricular catheter in three different ways: 1) free-hand by anatomical landmarks, 2) neuronavigation-assisted (NN), and 3) XperCT-guided (XCT). The number of ventricular hits and dangerous trajectories; time to proceed; radiation exposure of patients and physicians; distance of the catheter tip to target and size of deviations projected in the orthogonal plans were measured and compared. RESULTS: Insertion using XCT increased the probability of ventricular puncture from 69.2 to 90.2 % (p = 0.02). Non-assisted placements were significantly less precise (catheter tip to target distance 14.3 ± 7.4 mm versus 9.6 ± 7.2 mm, p = 0.0003). The insertion time to proceed increased from 3.04 ± 2.06 min. to 7.3 ± 3.6 min. (p < 0.001). The X-ray exposure for XCT was 32.23 mSv, but could be reduced to 13.9 mSv if patients were initially imaged in the hybrid-operating suite. No supplementary radiation exposure is needed for NN if patients are imaged according to a navigation protocol initially. CONCLUSION: This ex vivo study demonstrates a significantly improved accuracy and safety using either NN or XCT-assisted methods. Therefore, efforts should be undertaken to implement these new technologies into daily clinical practice. However, the accuracy versus urgency of an EVD placement has to be balanced, as the image-guided insertion technique will implicate a longer preparation time due to a specific image acquisition and trajectory planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Manifestations of external ventricular drain (EVD) - associated infections overlap with those of the underlying neurosurgical conditions. We analyzed characteristics of EVD-associated infections. METHODS: We included patients aged ≥18 years with EVD-associated infections from 1997 to 2008, using modified CDC criteria for nosocomial infections. Hospital charts were reviewed retrospectively and the in-hospital outcome was evaluated. RESULTS: Forty-eight patients with EVD-associated infections were included (median age, 52 years, range 20-74 years). The median EVD-indwelling time was 7 days (range, 1-39 days) and EVD-associated infection occurred 6 days after insertion (range, 1-17 days). In 23% of patients, meningitis occurred 1-10 days after EVD removal. Fever >38 °C was present in 79% of patients, but Glasgow Coma Scale (GCS) scores were reduced in only 29%, and headache, vomiting and/or neck stiffness were present in only 31%. The median cerebrospinal fluid (CSF) leukocyte count was higher at onset of EVD-associated infection than at EVD insertion (175 × 10(6)/l versus 46 × 10(6)/l, p = 0.021), but other CSF parameters did not differ significantly. The most commonly implicated organisms were coagulase-negative staphylococci (63%) and Propionibacterium acnes (15%). CONCLUSIONS: Fever and increased CSF leukocytes should raise the suspicion of EVD-associated infection, which may occur up to 10 days after removal of EVD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients affected with intra-thoracic recurrences of primary or secondary lung malignancies after a first course of definitive radiotherapy have limited therapeutic options, and they are often treated with a palliative intent. Re-irradiation with stereotactic ablative radiotherapy (SABR) represents an appealing approach, due to the optimized dose distribution that allows for high-dose delivery with better sparing of organs at risk. This strategy has the goal of long-term control and even cure. Aim of this review is to report and discuss published data on re-irradiation with SABR in terms of efficacy and toxicity. Results indicate that thoracic re-irradiation may offer satisfactory disease control, however the data on outcome and toxicity are derived from low quality retrospective studies, and results should be cautiously interpreted. As SABR may be associated with serious toxicity, attention should be paid for an accurate patients' selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a retrospective study on 22 operations of exostosis of the external auditory canal in 20 patients. 8 patients were passionated by water sports. The most frequent indication for surgery (13 operations) was recurrent external otitis or ceruminal obstruction. In 7 cases the need for a wider access to the middle ear indicated surgery. Surgery was usually performed as an outpatient procedure, maximum hospitalization was 3 days. The mean healing period was 6 (3-10) weeks. Mean follow up was 43 (3-110) months. There were no severe intraoperative complications such as facial paresis, lesions of the ossicles or of the inner ear. As intraoperative complications we found 2 perforations of the tympanic membrane, 2 expositions of the capsule of the mandibular joint, one of which was followed by chronic pain. As postoperative complications we found an early soft tissue stenosis of the external auditory canal and one late soft tissue stenosis which recurred after revision surgery. No recurrence of exostosis was seen. We describe an up to now unknown complication: the appearance of bilateral petrositis caused by staphylococcus epidermidis after bilateral surgery in an otherwise healthy patient. This study confirms that severe complications are rare, minor ones however relatively common. And that also minor complications may have a troublesome follow. Therefore and because of the potential of severe complications indication for surgery must be made cautiously and risks of the operation must not be underestimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid and large accumulation of GABA (y-aminobutyric acid) in response to a number of plant stresses has been well documented. But the role(s) of GABA in plants is not well defined. In recent years, the possibility of GABA involvement in regulating plant growth and development has been raised. In the present study, this possibility was examined. First, to rapidly and accurately determine GABA levels in plant tissues, a spectrometric method for GABA determination was developed based on a commercially available enzyme Gabase. Seventy mM LaCb almost completely removed water-soluble pigments from plant tissues which greatly interfere with the absorbance reading at 340nm. Inactivation of GAD (glutamate decarboxylase) by immediately adding methanol to a frozen plant tissue powder was suggested to prevent GABA production during extraction. The recovery of GABA with this method was approximately 100%. Second, the relationship between GABA levels and hypocotyl elongation in soybean seedlings was analyzed using different approaches to regulate in vivo GABA levels and the elongation of hypocotyls. The following major observations were made. (1) Mechanical stimulation by stroking elevated GABA levels and concurrently induced a rapid and significant reduction in hypocotyl elongation. (2) External GABA was demonstrated to penetrate into the hypocotyls using '*C-GABA. Application of external GABA elevated in vivo GABA levels, but failed to inhibit hypocotyl elongation. (3) LaCla and blue light irradiation caused an inhibition in the elongation of dark-grown hypocotyls, whereas GABA levels were not significantly affected. (4) Ca^was suggested to be involved in the signal transduction pathway leading from mechanical stimulation to GABA production, as indicated by the ability of La'* to inhibit GABA production in stimulated hypocotyls. (5) Bicuculline, saclofen and baclofen (agonists and antagonists of GABA receptors in animals) had no effect on hypocotyl elongation. It might indicate that GABA-binding components which are structurally similar to animal GABA receptors and functionally capable of regulating plant growth may not exist in plants. Therefore, the conclusion was drawn that GABA alone is not sufficient to inhibit hypocotyl elongation. Third, chloride influx in isolated Asparagus cells was enhanced by lOmM GABA during a 3 hour incubation, but the effect was not specific for GABA. Chloride efflux was not influenced by GABA. Both influx and efflux of chloride were significantly inhibited by NPPB, a chloride channel blocker. These results suggest that GABA does not influence the activity of plant chloride channels.