971 resultados para Diagnostic tests and procedures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study evaluated the flow, pH and calcium release of MTA Fillapex (G1) or Fillapex plus 10% in weight of calcium hydroxide powder (G2), compared to AH Plus (G3) and Sealapex (G4). Materials and methods:The flow test was performed according to ISO 6876:2001 requirements. The sealers were placed into plastic tubes and immersed in deionized water. After 24 hours, 7, 14 and 28 days, the water of each tube was removed and tested to evaluate the pH values and the level of released calcium. Calcium release values were analyzed statistically by Kruskal Wallis and Dunn tests and pH values analyzed by ANOVA and Tukey tests (? = 5%). Results:G1 presented higher flow among all sealers. The addition of 10% calcium hydroxide into MTA Fillapex reduced the flow (p < 0.05) but, in a level, that is lower than the one recommended for ISO norms. G2 and G4 presented pH values and calcium release higher than G3 (p < 0.05) in all periods. G1 presented pH value higher than G3 (p < 0.05), except in 7 days period (p > 0.05). G4 presented higher pH values than G1 and G2, but the calcium release was similar for all periods (p > 0.05). G3 presented lower calcium release among all groups (p < 0.05). Conclusion: The addition of 10% calcium hydroxide in MTA Fillapex caused reduction in flow and no negative interference in pH and/or calcium release. However, the obtained flow is different from ISO requirements. Clinical relevance: MTA Fillapex presents levels of flow above the ISO norms. The addition of calcium hydroxide is a suggestion for solving this problem, but the impact of these procedures should be carefully evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although vancomycin-resistant enterococci (VRE) are reported in Brazil since 1996, data on their impact over settings of different complexity are scarce. We performed a study aimed at identifying determinants ofVRE emergence and spread in a public hospital consortium (comprising 2 hospitals, with 318 and 57 beds) in inner Brazil. Molecular typing and case-control studies (addressing predictors of acquisition or clonality) were performed. Among 122 authocthonous isolates, 106 were Enterococcus faecium (22 clones), and 16, Enterococcus faecalis (5 clones). Incidence was greater in the small-sized hospital, and a previous admission to this hospital was associated with greater risk of VRE colonization or infection during admission to the larger one. Overall risk factors included comorbidities, procedures, and antimicrobials (piperacillin-tazobactam, cefepime, and imipenem). Risk factors varied among different hospitals, species, and clones. Our findings demonstrate that VRE can spread within low-complexity facilities and from these to larger hospitals. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to evaluate the performance of diagnostic tools to establish an affordable setting for early detection of cervical cancer in developing countries. We compared the performance of different screening tests and their feasibility in a cohort of over 12,000 women: conventional Pap smear, liquid-based cytology, visual inspection with acetic acid (VIA), visual inspection with Iodine solution (VILI), cervicography, screening colposcopy, and high-risk human papillomavirus (HPV) testing (HR-HPV) collected by physician and by self-sampling. HR-HPV assay collected by the physician has the highest sensitivity (80 %), but high unnecessary referrals to colposcopy (15.1 %). HR-HPV test in self-sampling had a markedly lower (57.1 %) sensitivity. VIA, VILI, and cervicography had a poor sensitivity (47.4, 55, and 28.6 %, respectively). Colposcopy presented with sensitivity of 100 % in detecting CIN2+, but the lowest specificity (66.9 %). Co-testing with VIA and VILI Pap test increased the sensitivity of stand-alone Pap test from 71.6 to 87.1 % and 71.6 to 95 %, respectively, but with high number of unnecessary colposcopies. Co-testing with HR-HPV importantly increased the sensitivity of Pap test (to 86 %), but with high number of unnecessary colposcopies (17.5 %). Molecular tests adjunct to Pap test seems a realistic option to improve the detection of high-grade lesions in population-based screening programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background In areas with limited structure in place for microscopy diagnosis, rapid diagnostic tests (RDT) have been demonstrated to be effective. Method The cost-effectiveness of the Optimal® and thick smear microscopy was estimated and compared. Data were collected on remote areas of 12 municipalities in the Brazilian Amazon. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, hospitalization records, primary data collected from the municipalities, and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2006. The results were expressed in costs per adequately diagnosed cases in 2006 U.S. dollars. Sensitivity analysis was performed considering key model parameters. Results In the case base scenario, considering 92% and 95% sensitivity for thick smear microscopy to Plasmodium falciparum and Plasmodium vivax, respectively, and 100% specificity for both species, thick smear microscopy is more costly and more effective, with an incremental cost estimated at US$549.9 per adequately diagnosed case. In sensitivity analysis, when sensitivity and specificity of microscopy for P. vivax were 0.90 and 0.98, respectively, and when its sensitivity for P. falciparum was 0.83, the RDT was more cost-effective than microscopy. Conclusion Microscopy is more cost-effective than OptiMal® in these remote areas if high accuracy of microscopy is maintained in the field. Decision regarding use of rapid tests for diagnosis of malaria in these areas depends on current microscopy accuracy in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The knee joint is a key structure of the human locomotor system. The knowledge of how each single anatomical structure of the knee contributes to determine the physiological function of the knee, is of fundamental importance for the development of new prostheses and novel clinical, surgical, and rehabilitative procedures. In this context, a modelling approach is necessary to estimate the biomechanic function of each anatomical structure during daily living activities. The main aim of this study was to obtain a subject-specific model of the knee joint of a selected healthy subject. In particular, 3D models of the cruciate ligaments and of the tibio-femoral articular contact were proposed and developed using accurate bony geometries and kinematics reliably recorded by means of nuclear magnetic resonance and 3D video-fluoroscopy from the selected subject. Regarding the model of the cruciate ligaments, each ligament was modelled with 25 linear-elastic elements paying particular attention to the anatomical twisting of the fibres. The devised model was as subject-specific as possible. The geometrical parameters were directly estimated from the experimental measurements, whereas the only mechanical parameter of the model, the elastic modulus, had to be considered from the literature because of the invasiveness of the needed measurements. Thus, the developed model was employed for simulations of stability tests and during living activities. Physiologically meaningful results were always obtained. Nevertheless, the lack of subject-specific mechanical characterization induced to design and partially develop a novel experimental method to characterize the mechanics of the human cruciate ligaments in living healthy subjects. Moreover, using the same subject-specific data, the tibio-femoral articular interaction was modelled investigating the location of the contact point during the execution of daily motor tasks and the contact area at the full extension with and without the whole body weight of the subject. Two different approaches were implemented and their efficiency was evaluated. Thus, pros and cons of each approach were discussed in order to suggest future improvements of this methodologies. The final results of this study will contribute to produce useful methodologies for the investigation of the in-vivo function and pathology of the knee joint during the execution of daily living activities. Thus, the developed methodologies will be useful tools for the development of new prostheses, tools and procedures both in research field and in diagnostic, surgical and rehabilitative fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kyrgyzstan reported 77.5 new human brucellosis cases per 100,000 people in 2007, which is one of the highest incidences worldwide. In Kyrgyzstan, the currently used diagnostic tests in humans and animals are the Rose Bengal Test and the Huddleson test. A national representative cross-sectional study using cluster sampling proportional to size in humans, cattle, sheep, and goats was undertaken to assess the apparent seroprevalence in humans and animals. A total of 4,936 livestock sera and 1,774 human sera were tested in Naryn, Chuy, and Osh Oblasts. The overall apparent seroprevalences of brucellosis were 8.8% in humans (95% CI 4.5-16.5), 2.8% (95% CI 1.6-4.9%) in cattle, 3.3% (95% CI 1.5-6.9%) in sheep, and 2.5% (95% CI 1.4-4.5%) in goats. Naryn Oblast had the highest seroprevalences in humans and sheep. More men than women were seropositive (OR = 1.96; P < 0.001). Human seroprevalence was significantly associated with small ruminant seroprevalence but not with cattle seroprevalence. Annual incidence of human brucellosis exposure, measured by serological tests, was more than ten times higher than the annual incidence of reported clinical brucellosis cases. This indicates an under-reporting of human brucellosis cases, even if only a fraction of seropositive people have clinical symptoms. In conclusion, this study confirms the high seroprevalence of brucellosis in Kyrgyzstan and warrants rapid effective intervention, among others, by mass vaccination of sheep and goats but also of cattle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Production of native antigens for serodiagnosis of helminthic infections is laborious and hampered by batch-to-batch variation. For serodiagnosis of echinococcosis, especially cystic disease, most screening tests rely on crude or purified Echinococcus granulosus hydatid cyst fluid. To resolve limitations associated with native antigens in serological tests, the use of standardized and highly pure antigens produced by chemical synthesis offers considerable advantages, provided appropriate diagnostic sensitivity and specificity is achieved. METHODOLOGY/PRINCIPAL FINDINGS: Making use of the growing collection of genomic and proteomic data, we applied a set of bioinformatic selection criteria to a collection of protein sequences including conceptually translated nucleotide sequence data of two related tapeworms, Echinococcus multilocularis and Echinococcus granulosus. Our approach targeted alpha-helical coiled-coils and intrinsically unstructured regions of parasite proteins potentially exposed to the host immune system. From 6 proteins of E. multilocularis and 5 proteins of E. granulosus, 45 peptides between 24 and 30 amino acids in length were designed. These peptides were chemically synthesized, spotted on microarrays and screened for reactivity with sera from infected humans. Peptides reacting above the cut-off were validated in enzyme-linked immunosorbent assays (ELISA). Peptides identified failed to differentiate between E. multilocularis and E. granulosus infection. The peptide performing best reached 57% sensitivity and 94% specificity. This candidate derived from Echinococcus multilocularis antigen B8/1 and showed strong reactivity to sera from patients infected either with E. multilocularis or E. granulosus. CONCLUSIONS/SIGNIFICANCE: This study provides proof of principle for the discovery of diagnostically relevant peptides by bioinformatic selection complemented with screening on a high-throughput microarray platform. Our data showed that a single peptide cannot provide sufficient diagnostic sensitivity whereas pooling several peptide antigens improved sensitivity; thus combinations of several peptides may lead the way to new diagnostic tests that replace, or at least complement conventional immunodiagnosis of echinococcosis. Our strategy could prove useful for diagnostic developments in other pathogens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 7-month-old male kitten was presented with chronic constipation and retarded growth. Clinical examination revealed disproportional dwarfism with mild skeletal abnormalities and a palpable thyroid gland. The presumptive diagnosis of congenital hypothyroidism was confirmed by low serum total thyroxine (tT(4)) concentration prior to and after the administration of thyroid stimulation hormone (TSH), increased endogenous TSH concentration and abnormal thyroid scintigraphic scan. The kitten had abnormal liver function tests and decreased insulin-like growth factor 1 (IGF-1) concentration, both of which returned to normal in correspondence with an improvement of the clinical signs after 6 weeks of thyroxine therapy. Congenital hypothyroidism is a rare disease that may present with considerable variation in clinical manifestation. In cases in which clinical signs are ambiguous, disorders such as portosystemic shunt and hyposomatotropism have to be taken into account as differential diagnosis. As hypothyroidism may be associated with abnormal liver function tests and low IGF-1 concentrations, test results have to be interpreted carefully.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of a periprosthetic joint infection (PJI) can be challenging, either because of the variable clinical presentation or because of previous antimicrobial treatment interfering with the detection of the pathogen. In recent years, various means to diagnose PJI have been analyzed. These include invasive and non-invasive laboratory tests, imaging procedures, and novel techniques such as sonication of implants and the use of molecular microbiology. In this review, both established and novel diagnostic procedures are presented. An algorithm for detecting PJI in patients with acute and chronic symptoms is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Fever is one of the most commonly seen symptoms in the pediatric emergency department. The objective of this study was to observe how the rapid testing for influenza virus impacts on the management of children with fever. METHODS: We performed a review of our pediatric emergency department records during the 2008/2009 annual influenza season. The BinaxNow Influenza A+B test was performed on patients with the following criteria: age 1.0 to 16.0 years, fever greater than 38.5 °C, fever of less than 96 hours' duration after the onset of clinical illness, clinical signs compatible with acute influenza, and nontoxic appearance. Additional laboratory tests were performed at the treating physician's discretion. RESULTS: The influenza rapid antigen test was performed in 192 children. One hundred nine (57%) were influenza positive, with the largest fraction (101 patients) positive for influenza A. The age distribution did not differ between children with negative and positive test results (mean, 5.3 vs. 5.1 years, not statistically significant). A larger number of diagnostic tests were performed in the group of influenza-negative patients. Twice as many complete blood counts, C-reactive protein determinations, lumbar punctures, and urinalyses were ordered in the latter group. CONCLUSIONS: Rapid diagnosis of influenza in the pediatric emergency department affects the management of febrile children as the confirmation of influenza virus infection decreases additional diagnostic tests ordered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnostic tests in patients with Hymenoptera venom allergy are frequently positive to venoms of both honey bee and wasp (Vespula). Component-resolved analysis with recombinant species-specific major allergens (rSSMA) may help to distinguish true double sensitization from crossreactivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To review systematically and critically, evidence used to derive estimates of costs and cost effectiveness of chlamydia screening. METHODS: Systematic review. A search of 11 electronic bibliographic databases from the earliest date available to August 2004 using keywords including chlamydia, pelvic inflammatory disease, economic evaluation, and cost. We included studies of chlamydia screening in males and/or females over 14 years, including studies of diagnostic tests, contact tracing, and treatment as part of a screening programme. Outcomes included cases of chlamydia identified and major outcomes averted. We assessed methodological quality and the modelling approach used. RESULTS: Of 713 identified papers we included 57 formal economic evaluations and two cost studies. Most studies found chlamydia screening to be cost effective, partner notification to be an effective adjunct, and testing with nucleic acid amplification tests, and treatment with azithromycin to be cost effective. Methodological problems limited the validity of these findings: most studies used static models that are inappropriate for infectious diseases; restricted outcomes were used as a basis for policy recommendations; and high estimates of the probability of chlamydia associated complications might have overestimated cost effectiveness. Two high quality dynamic modelling studies found opportunistic screening to be cost effective but poor reporting or uncertainty about complication rates make interpretation difficult. CONCLUSION: The inappropriate use of static models to study interventions to prevent a communicable disease means that uncertainty remains about whether chlamydia screening programmes are cost effective or not. The results of this review can be used by health service managers in the allocation of resources, and health economists and other researchers who are considering further research in this area.