20.00% 20.00%

Publicador:

Resumo:

Some efficient solution techniques for solving models of noncatalytic gas-solid and fluid-solid reactions are presented. These models include those with non-constant diffusivities for which the formulation reduces to that of a convection-diffusion problem. A singular perturbation problem results for such models in the presence of a large Thiele modulus, for which the classical numerical methods can present difficulties. For the convection-diffusion like case, the time-dependent partial differential equations are transformed by a semi-discrete Petrov-Galerkin finite element method into a system of ordinary differential equations of the initial-value type that can be readily solved. In the presence of a constant diffusivity, in slab geometry the convection-like terms are absent, and the combination of a fitted mesh finite difference method with a predictor-corrector method is used to solve the problem. Both the methods are found to converge, and general reaction rate forms can be treated. These methods are simple and highly efficient for arbitrary particle geometry and parameters, including a large Thiele modulus. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe and analyse the study design and manuscript deficiencies in original research articles submitted to Emergency Medicine. Methods: This was a retrospective, analytical study. Articles were enrolled if the reports of the Section Editor and two reviewers were available. Data were extracted from these reports only. Outcome measures were the mean number and nature of the deficiencies and the mean reviewers’ assessment score. Results: Fifty-seven articles were evaluated (28 accepted for publication, 19 rejected, 10 pending revision). The mean (± SD) number of deficiencies was 18.1 ± 6.9, 16.4 ± 6.5 and 18.4 ± 6.7 for all articles, articles accepted for publication and articles rejected, respectively (P = 0.31 between accepted and rejected articles). The mean assessment scores (0–10) were 5.5 ± 1.5, 5.9 ± 1.5 and 4.7 ± 1.4 for all articles, articles accepted for publication and articles rejected, respectively. Accepted articles had a significantly higher assessment score than rejected articles (P = 0.006). For each group, there was a negative correlation between the number of deficiencies and the mean assessment score (P > 0.05). Significantly more rejected articles ‘… did not further our knowledge’ (P = 0.0014) and ‘… did not describe background information adequately’ (P = 0.049). Many rejected articles had ‘… findings that were not clinically or socially significant’ (P = 0.07). Common deficiencies among all articles included ambiguity of the methods (77%) and results (68%), conclusions not warranted by the data (72%), poor referencing (56%), inadequate study design description (51%), unclear tables (49%), an overly long discussion (49%), limitations of the study not described (51%), inadequate definition of terms (49%) and subject selection bias (40%). Conclusions: Researchers should undertake studies that are likely to further our knowledge and be clinically or socially significant. Deficiencies in manuscript preparation are more frequent than mistakes in study design and execution. Specific training or assistance in manuscript preparation is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data warehouse is a data repository which collects and maintains a large amount of data from multiple distributed, autonomous and possibly heterogeneous data sources. Often the data is stored in the form of materialized views in order to provide fast access to the integrated data. One of the most important decisions in designing a data warehouse is the selection of views for materialization. The objective is to select an appropriate set of views that minimizes the total query response time with the constraint that the total maintenance time for these materialized views is within a given bound. This view selection problem is totally different from the view selection problem under the disk space constraint. In this paper the view selection problem under the maintenance time constraint is investigated. Two efficient, heuristic algorithms for the problem are proposed. The key to devising the proposed algorithms is to define good heuristic functions and to reduce the problem to some well-solved optimization problems. As a result, an approximate solution of the known optimization problem will give a feasible solution of the original problem. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HLA-A*0201 transgenic, H-2D(b)/mouse beta2-microglobulin double-knockout mice were used to compare and optimize the immunogenic potential of 17HIV 1-derived, HLA-A0201-restricted epitopic peptides. A tyrosine substitution in position 1 of the epitopic peptides, which increases both their affinity for and their HLA-A0201 molecule stabilizing capacity, was introduced in a significant proportion, having verified that such modifications enhance their immunogenicity in respect of their natural antigenicity. Based on these results, a 13-polyepitope construct was inserted in the pre-S2 segment of the hepatitis B middle glycoprotein and used for DNA immunization. Long-lasting CTL responses against most of the inserted epitopes could be elicited simultaneously in a single animal with cross-recognition in several cases of their most common natural variants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. To evaluate the effectiveness of three approaches to assisting the female partners of male problem drinkers with the stress imposed by the male's drinking. Design. Participants were assigned randomly via random number tables to one of three treatment conditions: supportive counselling, stress management or alcohol-focused couples therapy. Setting. The intervention took place at the Behaviour Research and Therapy Centre (BRTC), The University of Queensland. This research and training centre offers outpatient psychology services to the community. Participants. Sixty-one married women whose husbands drank heavily. Participants reported protracted alcohol problems, severe impact of alcohol on social functioning and severe marital distress. Measurement. The women's stress, alcohol consumption by the male, and relationship functioning were assessed at pre- and post-treatment and at 6-month follow-up. Interventions. All three treatments involved 15 1-hour sessions with the woman. In the alcohol-focused couple therapy, attempts were made to engage the man in these sessions. Results. Contrary to our predictions, there were few differences between the treatments. All three treatments were associated with reductions in the women's reported stress, with trends for somewhat greater reduction in the women's stress in the stress management and alcohol-focused couples therapy conditions than for supportive counselling. None of the treatments produced clinically significant reductions in men's drinking or relationship distress. Conclusion. The treatments ease stresses and burden but do not improve drinking or relationships. Limited power in the design restricted the capacity to detect differential treatment effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inverse, current density mapping (CDM) method has been developed for the design of elliptical cross-section MRI magnets. The method provides a rapid prototyping system for unusual magnet designs, as it generates a 3D current density in response to a set of target field and geometric constraints. The emphasis of this work is on the investigation of new elliptical coil structures for clinical MRI magnets. The effect of the elliptical aspect ratio on magnet performance is investigated. Viable designs are generated for symmetric, asymmetric and open architecture elliptical magnets using the new method. Clinically relevant attributes such as reduced stray field and large homogeneous regions relative to total magnet length are included in the design process and investigated in detail. The preliminary magnet designs have several novel features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New designs for force-minimized compact high-field clinical MRI magnets are described. The design method is a modified simulated annealing (SA) procedure which includes Maxwell forces in the error function to be minimized. This permits an automated force reduction in the magnet designs while controlling the overall dimensions of the system. As SA optimization requires many iterations to achieve a final design, it is important that each iteration in the procedure is rapid. We have therefore developed a rapid force calculation algorithm. Novel designs for short 3- and 4-T clinical MRI systems are presented in which force reduction has been invoked. The final designs provide large homogeneous regions and reduced stray fields in remarkable short magnets. A shielded 4-T design that is approximately 30% shorter than current designs is presented. This novel magnet generates a full 50-cm diameter homogeneous region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current exposures. A method using current exposure data, known exposure-response relationships and the semi-quantitative matrix is proposed for more accurate and current risk rankings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients who play musical instruments (especially wind and stringed instruments) and vocalists are prone to particular types of orofacial problems. Some problems are caused by playing and some are the result of dental treatment. This paper proposes to give an insight into these problems and practical guidance to general practice dentists. Method: Information in this paper is gathered from studies published in dental, music and occupational health journals, and from discussions with career musicians and music teachers. Results: Orthodontic problems, soft tissue trauma, focal dystonia, denture retention, herpes labialis, dry mouth and temporomandibular joint (TMJ) disorders were identified as orofacial problems of career musicians. Options available for prevention and palliative treatment as well as instrument selection are suggested to overcome these problems. Conclusions: Career musicians express reluctance to attend dentists who are not sensitive to their specific needs. General practitioner dentists who understand how the instruments impact on the orofacial structures and are aware of potential problems faced by musicians are able to offer preventive advice and supportive treatment to these patients, especially those in the early stages of their career.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.