998 resultados para Current injection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an analysis of factors influencing carrier transport and electroluminescence (EL) at 1.5 µm from erbium-doped silicon-rich silica (SiOx) layers. The effects of both the active layer thickness and the Si excess content on the electrical excitation of erbium are studied. We demonstrate that when the thickness is decreased from a few hundred to tens of nanometers the conductivity is greatly enhanced. Carrier transport is well described in all cases by a Poole-Frenkel mechanism, while the thickness-dependent current density suggests an evolution of both density and distribution of trapping states induced by Si nanoinclusions. We ascribe this observation to stress-induced effects prevailing in thin films, which inhibit the agglomeration of Si atoms, resulting in a high density of sub-nm Si inclusions that induce traps much shallower than those generated by Si nanoclusters (Si-ncs) formed in thicker films. There is no direct correlation between high conductivity and optimized EL intensity at 1.5 µm. Our results suggest that the main excitation mechanism governing the EL signal is impact excitation, which gradually becomes more efficient as film thickness increases, thanks to the increased segregation of Si-ncs, which in turn allows more efficient injection of hot electrons into the oxide matrix. Optimization of the EL signal is thus found to be a compromise between conductivity and both number and degree of segregation of Si-ncs, all of which are governed by a combination of excess Si content and sample thickness. This material study has strong implications for many electrically driven devices using Si-ncs or Si-excess mediated EL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chile has become a major actor in the blueberry industry as the most important supplier of off-season fresh fruit for the northern hemisphere. Blueberry exports passed from US$ 30 million (around 4,000 tons) in 2000 to US$ 380 million (94,000 tons) in 2011. The characteristics of the major blueberry growing regions (North, Central, South-central and South) are presented in terms of acreage, varieties, management practices, extension of the harvest season, and soil and climatic conditions. Most fruit is from highbush varieties, picked by hand and exported fresh by boat to United States. Largest proportion of fruit is exported from mid December to late January, which coincides with lowest prices. The south-central region (latitudes 34º50' to 38º15' S) was in 2007 the most important one with 5,075 ha (51.1% of area planted). Among the challenges for the Chilean blueberry industry in the near future are: 1. Lower profitability due to lower rates of currency exchange and higher costs, 2 - Greater scarcity and higher cost of labor, 3.- Need for higher productivity and sustainable production practices, 4- Fruit of high and consistent quality, and 5.- Greater investment in research. As a case study the article presents three approaches that can help identify areas with low availability of labor and improve its efficiency. The article shows the use of geomatic tools to establish labor availability, application of growth regulators to reduce crop load, increase fruit size and improve harvest efficiency, and the use of shakers to harvest fresh fruit for long distance markets. More research is needed to improve yields, reduce costs and give greater economical and ecological sustainability to the Chilean blueberry industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was designed to investigate the efficacy of the fluorescent dyes Fast Blue (FB), Fluoro-Gold (FG), and Diamidino Yellow (DY) for retrograde tracing of lumbar dorsal root ganglia after their subcutaneous injection into different hindlimb digits. Injection of equal volumes (0.5 mu l) of 5% FB or 2% FG resulted in similar mean numbers of sensory neurones labelled by each tracer. Injection of equal volumes (0.5 mu l) of FB or FG in a single digit followed 10 days later by a second injection of the same volume of 5% DY into the same digit resulted in similar mean numbers of labelled sensory neurones for each of the three tracers. Furthermore, on average, 75% of all the FB-labelled cells and 74% of all FC-labelled cells also contained DY. Repeating the same experiment with an increased volume of DY (1.5 mu l) resulted in an increase in the mean number of double-labelled profiles to 82 and 84% for FB and FG, respectively. The results show that FB, FG and DY label similar numbers of cutaneous afferents and that a high level of double labelling may be obtained after sequential injections in digits. These properties make them suitable candidates in investigations where a combination of tracers with similar labelling efficacies is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'imagerie par résonance magnétique (IRM) peut fournir aux cardiologues des informations diagnostiques importantes sur l'état de la maladie de l'artère coronarienne dans les patients. Le défi majeur pour l'IRM cardiaque est de gérer toutes les sources de mouvement qui peuvent affecter la qualité des images en réduisant l'information diagnostique. Cette thèse a donc comme but de développer des nouvelles techniques d'acquisitions des images IRM, en changeant les techniques de compensation du mouvement, pour en augmenter l'efficacité, la flexibilité, la robustesse et pour obtenir plus d'information sur le tissu et plus d'information temporelle. Les techniques proposées favorisent donc l'avancement de l'imagerie des coronaires dans une direction plus maniable et multi-usage qui peut facilement être transférée dans l'environnement clinique. La première partie de la thèse s'est concentrée sur l'étude du mouvement des artères coronariennes sur des patients en utilisant la techniques d'imagerie standard (rayons x), pour mesurer la précision avec laquelle les artères coronariennes retournent dans la même position battement après battement (repositionnement des coronaires). Nous avons découvert qu'il y a des intervalles dans le cycle cardiaque, tôt dans la systole et à moitié de la diastole, où le repositionnement des coronaires est au minimum. En réponse nous avons développé une nouvelle séquence d'acquisition (T2-post) capable d'acquérir les données aussi tôt dans la systole. Cette séquence a été testée sur des volontaires sains et on a pu constater que la qualité de visualisation des artère coronariennes est égale à celle obtenue avec les techniques standard. De plus, le rapport signal sur bruit fourni par la séquence d'acquisition proposée est supérieur à celui obtenu avec les techniques d'imagerie standard. La deuxième partie de la thèse a exploré un paradigme d'acquisition des images cardiaques complètement nouveau pour l'imagerie du coeur entier. La technique proposée dans ce travail acquiert les données sans arrêt (free-running) au lieu d'être synchronisée avec le mouvement cardiaque. De cette façon, l'efficacité de la séquence d'acquisition est augmentée de manière significative et les images produites représentent le coeur entier dans toutes les phases cardiaques (quatre dimensions, 4D). Par ailleurs, l'auto-navigation de la respiration permet d'effectuer cette acquisition en respiration libre. Cette technologie rend possible de visualiser et évaluer l'anatomie du coeur et de ses vaisseaux ainsi que la fonction cardiaque en quatre dimensions et avec une très haute résolution spatiale et temporelle, sans la nécessité d'injecter un moyen de contraste. Le pas essentiel qui a permis le développement de cette technique est l'utilisation d'une trajectoire d'acquisition radiale 3D basée sur l'angle d'or. Avec cette trajectoire, il est possible d'acquérir continûment les données d'espace k, puis de réordonner les données et choisir les paramètres temporel des images 4D a posteriori. L'acquisition 4D a été aussi couplée avec un algorithme de reconstructions itératif (compressed sensing) qui permet d'augmenter la résolution temporelle tout en augmentant la qualité des images. Grâce aux images 4D, il est possible maintenant de visualiser les artères coronariennes entières dans chaque phase du cycle cardiaque et, avec les mêmes données, de visualiser et mesurer la fonction cardiaque. La qualité des artères coronariennes dans les images 4D est la même que dans les images obtenues avec une acquisition 3D standard, acquise en diastole Par ailleurs, les valeurs de fonction cardiaque mesurées au moyen des images 4D concorde avec les valeurs obtenues avec les images 2D standard. Finalement, dans la dernière partie de la thèse une technique d'acquisition a temps d'écho ultra-court (UTE) a été développée pour la visualisation in vivo des calcifications des artères coronariennes. Des études récentes ont démontré que les acquisitions UTE permettent de visualiser les calcifications dans des plaques athérosclérotiques ex vivo. Cepandent le mouvement du coeur a entravé jusqu'à maintenant l'utilisation des techniques UTE in vivo. Pour résoudre ce problème nous avons développé une séquence d'acquisition UTE avec trajectoire radiale 3D et l'avons testée sur des volontaires. La technique proposée utilise une auto-navigation 3D pour corriger le mouvement respiratoire et est synchronisée avec l'ECG. Trois échos sont acquis pour extraire le signal de la calcification avec des composants au T2 très court tout en permettant de séparer le signal de la graisse depuis le signal de l'eau. Les résultats sont encore préliminaires mais on peut affirmer que la technique développé peut potentiellement montrer les calcifications des artères coronariennes in vivo. En conclusion, ce travail de thèse présente trois nouvelles techniques pour l'IRM du coeur entier capables d'améliorer la visualisation et la caractérisation de la maladie athérosclérotique des coronaires. Ces techniques fournissent des informations anatomiques et fonctionnelles en quatre dimensions et des informations sur la composition du tissu auparavant indisponibles. CORONARY artery magnetic resonance imaging (MRI) has the potential to provide the cardiologist with relevant diagnostic information relative to coronary artery disease of patients. The major challenge of cardiac MRI, though, is dealing with all sources of motions that can corrupt the images affecting the diagnostic information provided. The current thesis, thus, focused on the development of new MRI techniques that change the standard approach to cardiac motion compensation in order to increase the efficiency of cardioavscular MRI, to provide more flexibility and robustness, new temporal information and new tissue information. The proposed approaches help in advancing coronary magnetic resonance angiography (MRA) in the direction of an easy-to-use and multipurpose tool that can be translated to the clinical environment. The first part of the thesis focused on the study of coronary artery motion through gold standard imaging techniques (x-ray angiography) in patients, in order to measure the precision with which the coronary arteries assume the same position beat after beat (coronary artery repositioning). We learned that intervals with minimal coronary artery repositioning occur in peak systole and in mid diastole and we responded with a new pulse sequence (T2~post) that is able to provide peak-systolic imaging. Such a sequence was tested in healthy volunteers and, from the image quality comparison, we learned that the proposed approach provides coronary artery visualization and contrast-to-noise ratio (CNR) comparable with the standard acquisition approach, but with increased signal-to-noise ratio (SNR). The second part of the thesis explored a completely new paradigm for whole- heart cardiovascular MRI. The proposed techniques acquires the data continuously (free-running), instead of being triggered, thus increasing the efficiency of the acquisition and providing four dimensional images of the whole heart, while respiratory self navigation allows for the scan to be performed in free breathing. This enabling technology allows for anatomical and functional evaluation in four dimensions, with high spatial and temporal resolution and without the need for contrast agent injection. The enabling step is the use of a golden-angle based 3D radial trajectory, which allows for a continuous sampling of the k-space and a retrospective selection of the timing parameters of the reconstructed dataset. The free-running 4D acquisition was then combined with a compressed sensing reconstruction algorithm that further increases the temporal resolution of the 4D dataset, while at the same time increasing the overall image quality by removing undersampling artifacts. The obtained 4D images provide visualization of the whole coronary artery tree in each phases of the cardiac cycle and, at the same time, allow for the assessment of the cardiac function with a single free- breathing scan. The quality of the coronary arteries provided by the frames of the free-running 4D acquisition is in line with the one obtained with the standard ECG-triggered one, and the cardiac function evaluation matched the one measured with gold-standard stack of 2D cine approaches. Finally, the last part of the thesis focused on the development of ultrashort echo time (UTE) acquisition scheme for in vivo detection of calcification in the coronary arteries. Recent studies showed that UTE imaging allows for the coronary artery plaque calcification ex vivo, since it is able to detect the short T2 components of the calcification. The heart motion, though, prevented this technique from being applied in vivo. An ECG-triggered self-navigated 3D radial triple- echo UTE acquisition has then been developed and tested in healthy volunteers. The proposed sequence combines a 3D self-navigation approach with a 3D radial UTE acquisition enabling data collection during free breathing. Three echoes are simultaneously acquired to extract the short T2 components of the calcification while a water and fat separation technique allows for proper visualization of the coronary arteries. Even though the results are still preliminary, the proposed sequence showed great potential for the in vivo visualization of coronary artery calcification. In conclusion, the thesis presents three novel MRI approaches aimed at improved characterization and assessment of atherosclerotic coronary artery disease. These approaches provide new anatomical and functional information in four dimensions, and support tissue characterization for coronary artery plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adrenaline (epinephrine) auto-injectors provide life-saving pre-hospital treatment for individuals experiencing anaphylaxis in a community setting. Errors in handling adrenaline auto-injectors, particularly by children and healthcare professionals, have been reported. Reports of adrenaline overdoses are limited in the medical literature. In most of these cases, accidental adrenaline administration results from medical error. Exogenous administration of catecholamine is responsible for cardiovascular and metabolic responses, which may cause supraventricular tachycardia, ventricular dysrhythmias and myocardial ischemia. The authors present a unique autopsy case involving a 34 year-old woman who intentionally self-injected adrenaline using an adrenaline auto-injector as part of a suicide plan. Catecholamines and metanephrines were measured in peripheral and cardiac blood as well as urine and vitreous humor. Based on the results of all postmortem investigations, the cause of death was determined to be cardiac dysrhythmia and cardiac arrest following adrenaline self-injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">Video-assisted thoracoscopic surgery (VATS) is currently a routinely performed procedure for the management of early non small cell lung cancer. The oncological results of VATS in terms of local recurrence and overall survival are equivalent or superior to those of conventional thoracotomy with lower morbidity and hospital stay. In the field of pulmonary metastasectomy, current guidelines support a thoracotomy approach in order to properly palpate the lung and detect nodules too small to be identified on standard radiological examinations (typically less than 5mm in diameter). However, the oncological and clinical significance of these millimetric nodules is not known. This has led some thoracic surgeons to rethink the approach of solitary pulmonary metastasectomy: because of improvements in thin slice helical CT-scans, some support a VATS approach for solitary pulmonary nodules without formal bimanual palpation and suggest this allows equivalent oncological results and decreased surgical morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline-six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le traitement de l'hépatite C chronique a été révolutionné par l'introduction de nouveaux antiviraux (directly acting antivirals [DAA]). Ces inhibiteurs de protéase, de la protéine NS5A et de la polymérase peuvent être associés dans des traitements oraux hautement efficaces et bien tolérés sans interféron. Dans cet article, nous fournissons un aperçu du traitement actuel de l'hépatite C chronique avec considération particulière des DAA actuellement autorisés en Suisse. Treatment of chronic hepatitis C is currently being revolutionised, with the introduction of directly acting antivirals (DAA), including protease, NS5A and polymerase inhibitors. These can be combined in interferon-free oral therapies with unprecedented efficacy and good tolerance. Here, we review the current therapy of chronic hepatitis C, with a particular focus on DAA that are approved in Switzerland today.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the effectiveness and safety of Posterior Sub-Tenon (PST) Triamcinolone Acetonide (TA) injection for persistent macular oedema associated with non-ischemic Central Retinal Vein Occlusion (CRVO) or Branch Retinal Vein Occlusion (BRVO) in non-vitrectomized eye. Methods: Fourteen consecutive eyes of 14 patients characterized by macular oedema lasting more than 3 months and with a visual acuity of less than 20/40 were enrolled. Six eyes presented with BRVO, 8 eyes with CRVO. PST injection of 40 mg TA was performed in topical anaesthesia. All patients were phakic, and followed for at least 6 months. Snellen visual acuity converted to LogMAR units and anatomic responses were evaluated before, and at 1, 3, 6, and 12 (if required) months after injections and re-injection considered. Results: In the BRVO group, mean foveal thickness was 548.2±49.50 μm preoperatively, and 452.8±56.2 μm and 280.8±62.5 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test) 3 months after injections. Improvement of visual acuity by at least 0.2 LogMAR was seen in 3(50%) of the 6 eyes. No re-injection was needed. In the CRVO group, mean foveal thickness was 543.7±34.4 μm preoperatively, and 283.0±29.0 μm and 234.8±23.6 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test). Improvement of visual acuity by at least 0.2 LogMAR was seen in 7 eyes (88%). Mean number of re-injection was of 2.1±0.3. Intraocular pressure elevation of 22 mm Hg or higher was found in 2/14 eyes (14%). Cataract progression was noted in 5/14 eyes (36%). Conclusions: PST injection of TA appears to be as safe and effective treatment for chronic macular oedema associated due to both non-ischemic BRVO or CRVO, with a better efficacy in BRVO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delirium is an acute disorder of attention and cognition seen relatively commonly in people aged 65 yr or older. The prevalence is estimated to be between 11 and 42 per cent for elderly patients on medical wards. The prevalence is also high in nursing homes and long term care (LTC) facilities. The consequences of delirium could be significant such as an increase in mortality in the hospital, long-term cognitive decline, loss of autonomy and increased risk to be institutionalized. Despite being a common condition, it remains under-recognised, poorly understood and not adequately managed. Advanced age and dementia are the most important risk factors. Pain, dehydration, infections, stroke and metabolic disturbances, and surgery are the most common triggering factors. Delirium is preventable in a large proportion of cases and therefore, it is also important from a public health perspective for interventions to reduce further complications and the substantial costs associated with these. Since the aetiology is, in most cases, multfactorial, it is important to consider a multi-component approach to management, both pharmacological and non-pharmacological. Detection and treatment of triggering causes must have high priority in case of delirium. The aim of this review is to highlight the importance of delirium in the elderly population, given the increasing numbers of ageing people as well as increasing geriatric age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To present a protocol for a multi-phase study about the current practice of end-of-life care in paediatric settings in Switzerland. BACKGROUND: In Switzerland, paediatric palliative care is usually provided by teams, who may not necessarily have specific training. There is a lack of systematic data about specific aspects of care at the end of a child's life, such as symptom management, involvement of parents in decision-making and family-centred care and experiences and needs of parents, and perspectives of healthcare professionals. DESIGN: This retrospective nationwide multicentre study, Paediatric End-of-LIfe CAre Needs in Switzerland (PELICAN), combines quantitative and qualitative methods of enquiry. METHODS: The PELICAN study consists of three observational parts, PELICAN I describes practices of end-of-life care (defined as the last 4 weeks of life) in the hospital and home care setting of children (0-18 years) who died in the years 2011-2012 due to a cardiac, neurological or oncological disease, or who died in the neonatal period. PELICAN II assesses the experiences and needs of parents during the end-of-life phase of their child. PELICAN III focuses on healthcare professionals and explores their perspectives concerning the provision of end-of-life care. CONCLUSION: This first study across Switzerland will provide comprehensive insight into the current end-of-life care in children with distinct diagnoses and the perspectives of affected parents and health professionals. The results may facilitate the development and implementation of programmes for end-of-life care in children across Switzerland, building on real experiences and needs. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01983852.