956 resultados para Correntes eletricas - Aterramento
Resumo:
Atmospheric Discharges are responsible for several lost in the electrical system therefore it´s done studies to find ways to reduce the problem caused by discharges. This branch of engineering is necessary the gathering, stock and analysis of large quantity of data to validate or refuse the many studies produced about it The CENDAT proposed a project to collect data on induced voltages in distribution lines and current waveform of the lightning, but a difficulty that arose was the accumulation of data due to lack of manpower available to catalog all the data collected. Thinking in this difficulty, the engineer Acacio Silva Neto CENDAT´s researcher with trainees began to develop a program to solve this problem. This work keeps the development of this program in order to solve the problem of accumulation of data
Resumo:
This paper discusses the importance of energy efficiency and the use of alternative energy sources, facing to the increasing energy demand and the concomitant economic, social and environmental restrictions imposed by society. In this work, alternative sources are illustrated by photovoltaic, micro turbines and fuel cells microgeneration systems. Energy efficiency is presented by direct current microgrids because its uses excludes the conversions of direct current (DC) to alternating current (AC) losses made with the intention of injecting energy into the electric grid and then the inverse conversion, AC to DC, in order to feed residential loads. The object of this paper is to analyze a case study and evaluates the costs and technical feasibility of a Project that combines a DC microgrid and a microgeneration system
Resumo:
The increase in energy consumption in the world has caused the electrical systems becoming ever larger and more complex. Because of that becomes necessary to use special tools to efficiently manage the equipment present in these systems. Nowadays a tool very used is the remote monitoring of assets which works collecting signals using sensors processing these signals and make them available to the system user. So the user can use informations that may assist him efficiently in making decisions when doing a maintenance. The system is technically efficient since it improves the measurement process and enables the asset management of a substation by using advanced technology for that and economically viable especially in cases where the user is subject to monetary loss due an interruption of power supply
Resumo:
This paper addresses the topics required for the selection of surge arresters used, the output of autotransformers, which protect the system Auxiliary Services (SE) of an electrical substation. Surge arresters used are part of the Protection System Lightning (SPDA). Transmission lines mostly run through regions with orographic well diversified and have constant weather changes, which lead to many undesirable interactions with electromagnetic phenomena, such as giving rise to blackout on 10 November 2009, which left nine states without power, which led to unplanned shutdowns in the system that left millions of people without electricity. This work of completion is to determine whether the method used in the selection of surge arresters meet the protection needs faced by a substation auxiliary services, through the use of software use ATPDraw
Resumo:
On the field of the projects of hydraulic systems exists a lot of worries when we talk about the calculate of hydraulic pumps. In this case some facts must be considerate: length of tubes, fluid characteristics, height gauge, temperature, pressure, characteristics of tubes, flow required and others. For that mathematic calculates must be developed with the objective to optimize hydraulic pumps and agree to find an ideal machine (that don't requires more energy than necessary or less energy than it requires; that is the more critical case, cause exists the risk that the fluid pumped do not agree to become in your destiny). The wrong calculate of this machine can super-size its, bringing an excessive energy consumption. Actually it's an important subject because we are in the age of lack of energy what turn it more expensive. So the correct sizing of a hydraulic pump is connected with the fact that you have to uses the enough energy resources avoiding waste. The calculate of ideal pump in the pumping system is studied during years and a lot of specialists in this subject develop equations and theories to calculate its. Some researches study about this subject and all of them become to the same conclusion: to find the ideal pump we have to know the characteristics of fluid (cinematic viscosity), the required flow , overall yield (overall of motor x overall of pump) the high gauge or discharge pressure and the loss of repression. The pressure drop can be calculated with different theories: using Hazen-Williams, Darcy e Weisbach or Chézy (1775 - that starts the researches to calculate the pressure drop). Although the most used theory and what is most near to reality is the Darcy's equation. So, in this job the Darcy's equation were choice to calculate the drop pressure that consider what kind of flow we are studying: laminar or turbulent. The determination of the best pump to be used in the ... ( complete abstract click eletronic access below)
Resumo:
In this paper are compared two methods of deploying electrical substations, conventional type, when installed at open areas (Air Insulated Switchgear - AIS), and compact gas-insulated (Gas Insulated Switchgear - GIS) when installed inside buildings. With the expansion of urban centers, areas available for deployment of conventional substations become increasingly difficult to find in these locations. Also due to speculation in urban areas, it becomes feasible to install Gas Insulated Switchgear. This paper presents and evaluates criteria with advantages and disadvantages for application of the two methodologies, aiming to assist in decisionmaking moment of choice in deployment of Electric Power Substations in two scenarios. It is expected that at the end of this work, the criteria evaluated assist in this decision making
Resumo:
This study aims to analyze the feasibility of using predictive techniques like thermography, vibration analysis, eddy current, liquid penetrant, visual examination and ultrasound in equipment as batch reactors of the type used in a biodiesel production company. This study is based on: analysis of the practices of corrective and preventive maintenance commonly adopted in the company in question, the cost and time spent for such activities and the potential savings and revenue generation that can be after implementation of these techniques on the analysis of maintenance current
Resumo:
Brazil faces a complex problem in respect to municipal solid waste, having been in recent years an increase of its generation without the country there be adequate for proper disposal thereof. In many states , the percentage of waste destined improperly , ie , in dumps , landfills, send- outs , among others , is greater than that disposed in landfills , which would be the most correct way to be made. It can be argued that this discrepancy is due to the high cost of implementation and operation of the landfill, and the same need large areas with physical characteristics that suit their operations . When there is a provision in properly constructed landfills , municipal solid waste grounded generate gases with high potential energy through biochemical reactions during the anaerobic decomposition of organic material stored . Such gases can be used for power generation within the landfill or other economic means . To estimate the gas generation will be sufficient for such economic compensation , there are mathematical models that make estimating the amount of gas produced . These models calculate the energy capacity and generation , using parameters obtained based on the characteristics of solid waste , climate of the region where they are grounded and grounding time . Such models have been raised and studied so that it was possible to perform simulations that demonstrate the behavior of biogas generation related to the external conditions of the landfill that interfere with biological reactions within. The results show differences between the values obtained , it shows that the preparation of the models found and used in the simulations were allocated amounts for different parameters that determine this difference in the estimate . Therefore, to rule, the models have difficulty understanding this because there is no clarity in the formulation of the equations , and the definition of variables and parameters would require a detailed study to...
Resumo:
Are presented on this paper, concepts of corrective, preventive and predictive maintenances, following the prerequisites for planning and implementation of a maintenance plan. You also find the theoretical introduction of some measurement instruments accompanied by the necessary and recommended activities during routine maintenances of the electrical equipments in a building installation. Using case study, it is possible to assess a real maintenance plan applied to two occupied floors in a financial institution. The developing of a case study consolidates the effectiveness of the present concepts on this theoretical introduction and shows that the current maintenance plan can be improved in order to obtain better results on company productivity and reliability of equipments. As a conclusion, we can notice the importance of a solid maintenance plan and the need of including this theme on the graduation in Electrical Engineering
Resumo:
The proposed of scanning of an electrical industrial substation HV is associated with a segment of the Electrotechnical area and aims the study and preliminary application of digital technologies in the protection, control, measurement and automation maneuvers aimed at a Industrial Electrical System typical High Voltage. Well intended to supervision, protection and control of major electrical and thermal quantities involved in a substation, such as voltage levels, current, temperature, power factor, loads of transformers and circuit feeders, status of interlocking devices, switching equipment maneuvers, etc
Resumo:
This paper presents the study on the application of the electrolytic plasma for surface treatment of aluminum. A bibliographical study on the material of interest was preliminarily performed and later designed and built an electrolytic cell, including the excitation source. Unlike conventional electrolysis process, the plasma assisted carry on in the non-linear region of characteristic current/voltage curve. Therefore it requires for the on set of the process that the power supply operates on harder conditions than those on high current process. The plasma produced during the present investigation has temperatures in the range o 6,0.10 3 -7,0 .10 3 K, well above those found in conventional chemical process. It also shows a particular dynamic to promote changes on surface and to produce new materials. The plasma is generated by microdischarge in vapor or gas bubbles involved in physic-chemical processes in electrode regions of the electrolytic cell. The electrode material was the aluminum (7075). The Process Electrolytic Plasma Processing (EPP) is sensitive to various parameters such as operating voltage, current density, electrolyte, concentration of electrolyte, geometry of reactor, temperature of electrolytic solution and dynamic of the fluid in the cell. The experiments were carried on in order to find parameters for a stable abd steady operation. The choice for the electrolytic was silicate/alkali solution in various concentrations to operate in various voltage as well. Plasma was produced on negative (cathode) and positive (anode) electrode, in specific conditions. A stable operation on the cathode process was obtained with low concentration of the electrolytic in aqueous solution, current density around 250V effective voltage. For the evolution of plasma in anodic process it was required higher concentrations and higher... (Complete abstract click electronic access below)
Resumo:
With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system
Resumo:
Solar energy can be considered the largest source of energy available on earth and has attracted in recent decades, attention and interest for its rational use. The use of energy sources in a sustainable manner is essential to the survival of future generations, due to the scarcity of natural resources and their exploitation in a disorderly way. Studies related to the applications of renewable sources becomes then relevant, given its great importance as regards the conscious use of resources provided by nature, with the least possible impact on it. The present study presents an evaluation of generation potential and feasibility of implementing a solar photovoltaic connected to the grid and connected to the roofs of some buildings of the Faculty of Engineering of Guaratinguetá - FEG, to supply the demand of electric energy consumption on campus and attempting to inject a possible surplus power generation in local power grid, increasing network capacity and reducing peak loads
Resumo:
The human social organization has undergone major changes in recent years. The technological and digital revolutions accelerated the process of dissemination and evolution of the knowledge in all sciences, from social studies to nanotechnology. This process led to many advances that have enabled the emergence of new markets. Among these new markets, residential automation shows to be a market of great potential, seeking to meet the needs of residents, in order to make their daily practice and as fast as the rhythm of present life requests. To perform this task the residence stops being a passive place and becomes an active and controllable system, where actions may occur without the need for direct human interaction. The aim of this work is designing the electrical installation of a residence seeking better use of energy and show the technology diversity involving intelligent houses
Resumo:
A parameter commonly used in investigations of environmental magnetism is the magnetic susceptibility (MS), which is the quantitative measure of the ability of magnetization of a specific material in the presence of an induced magnetic field. The present study aimed to determine the magnetic susceptibility of sediments collected on the continental shelf near the Santos Basin, southeast of the São Sebastião island (25°57.97’S 45°07.81'W), seeking to identify the possible source area of terrigenous sediments and the flow patterns of siliciclastic sediment yield in the area. It was used particle size analysis and contents of organic matter and calcium carbonate to characterize the sediments, besides paleomagnetism parameters. The analyzed material - core NAP61-1 - was collected using the piston corer sampler in 60 meters water depth, recovering 3.98 meters of sediment core. As from experiments, cyclicity was observed in relative abundance between sand and silt, most likely due to rapid and cyclical variations in the depositional environment. In general, the MS values are low, and show that the sand supply (terrigenous material) has a certain consistency, probably having the same origin. More absolute age is still necessary to establish clearly the events marked here