998 resultados para Controlled mating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of a sub-seabed CO2 leak from geological sequestration on the microbial process of ammonia oxidation was investigated in the field. Sediment samples were taken before, during and after a controlled sub-seabed CO2 leak at four zones differing in proximity to the CO2 source (epicentre, and 25m, 75m, and 450m distant). The impact of CO2 release on benthic microbial ATP levels was compared to ammonia oxidation rates and the abundance of bacterial and archaeal ammonia amoA genes and transcripts, and also to the abundance of nitrite oxidize (nirS) and anammox hydrazine oxidoreductase (hzo) genes and transcripts. The major factor influencing measurements was seasonal: only minor differences were detected at the zones impacted by CO2 (epicentre and 25m distant). This included a small increase to ammonia oxidation after 37daysof CO2 release which was linked to an increase in ammonia availability as a result of mineral dissolution. A CO2 leak on the scale used within this study (<1tonneday−1) would have very little impact to ammonia oxidation within coastal sediments. However, seawater containing 5% CO2 did reduce rates of ammonia oxidation. This was linked to the buffering capacity of the sediment, suggesting that the impact of a sub-seabed leak of stored CO2 on ammonia oxidation would be dependent on both the scale of the CO2 release and sediment type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2012, a controlled sub-seabed release of carbon dioxide (CO2) was conducted in Ardmucknish Bay, a shallow (12 m) coastal bay on the west coast of Scotland. During the experiment, CO2 gas was released 12 m below the seabed for 37 days, causing significant disruption to sediment and water carbonate chemistry as the gas passed up through the sediment and into the overlying water. One of the aims of the study was to investigate how the impacts caused by leakage from geological CO2 Capture and Storage (CCS) could be detected and quantified in the context of natural heterogeneity and dynamics. To do this underwater photography was used to analyze (i) the benthic megafaunal response to the CO2 release and (ii) the dynamics of the CO2 bubble streams, emerging from the seabed into the overlying water column. The frequently observed megafauna species in the study area were Virgularia mirabilis (Cnidaria), Turritella communis (Mollusca), Asterias rubens (Echinodermata), Pagurus bernhardus (Crustacea), Liocarcinus depurator (Crustacea), and Gadus morhua (Osteichthyes). No discernable abnormal behavior was observed for these megafauna, in any of the zones investigated, during or after the CO2 release. Time-lapse photography revealed that the intensity and presence of the CO2 bubble plume was affected by the tides, with the most active bubbling seen at low tides and the larger hydrostatic pressure at high tide suppressing CO2 bubbling from the seabed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract There is considerable interest in developing medical devices that provide controlled delivery of biologically active agents, for example, to reduce the incidence of device-related infection. Silicone elastomers are one of the commonest biomaterials used in medical device production. However, they have a relatively high coefficient of friction and the resulting lack of lubricity can cause pain and tissue damage on device insertion and removal. Novel silicone cross-linking agents have recently been reported that produce inherently ‘self-lubricating’ silicone elastomers with very low coefficients of friction. In this study, the model antibacterial drug metronidazole has been incorporated into these self-lubricating silicone elastomers to produce a novel bioactive biomaterial. The in vitro release characteristics of the bioactive component were evaluated as a function of cross-linker composition and drug loading. Although conventional matrix-type release kinetics were observed for metronidazole from the silicone systems, it was also observed that increasing the concentration of the cross-linking agent responsible for the lubricious character (tetra(oleyloxy)silane) relative to that of the standard non-lubricious cross-linking agent (tetrapropoxysilane) produced an increase in the metronidazole flux rate by up to 65% for a specified drug loading. The results highlight the potential for developing lubricious silicone medical devices with enhanced drug release characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Lung inflammation and injury is critical in cystic fibrosis. An ideal antiinflammatory agent has not been identified but inhaled corticosteroids are widely used despite lack of evidence.

Objectives: To test the safety of withdrawal of inhaled corticosteroids with the hypothesis this would not be associated with an earlier onset of acute chest exacerbations.

Methods: Multicenter randomized double-blind placebo-controlled trial in 18 pediatric and adult UK centers. Eligibility criteria included age > 6.0 yr, FEV1 ? 40% predicted, and corticosteroid use > 3 mo. During the 2-mo run-in period, all patients received fluticasone; they then took either fluticasone or placebo for 6 mo.

Measurements and Main Results: Fluticasone group: n = 84, median age 14.6 yr, mean (SD) FEV1 76% (18); placebo group: n = 87, median age 15.8 yr, mean (SD) FEV1 76% (18). There was no difference in time to first exacerbation (primary outcome) with hazard ratio (95% confidence interval) of 1.07 (0.68 to 1.70) for fluticasone versus placebo. There was no effect of age, atopy, corticosteroid dose, FEV1, or Pseudomonas aeruginosa status. There was no change in lung function or differences in antibiotic or rescue bronchodilator use. Fewer patients in the fluticasone group withdrew from the study due to lung-related adverse events (9 vs. 15%); with a relative risk (95% confidence interval) of 0.59 (0.23–1.48) fluticasone versus placebo.

Conclusions: In this study population (applicable to 40% of patients with cystic fibrosis in the UK), it appears safe to consider stopping inhaled corticosteroids. Potential advantages will be to reduce the drug burden on patients, reduce adverse effects, and make financial savings.