901 resultados para Contour extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manuscript describes the use of a tooth indicated for extraction due
to orthodontic reasons as an anchorage aid to receive undesirable side effects caused by orthodontic uprighting of a contralateral molar tooth. The mandibular right second molar was mesially tipped as a result of loss of the adjacent first molar. Since the treatment plan involved extraction of the mandibular left first premolar, undesirable side effects associated with the molar uprighting movement were transferred to this tooth. Once the second molar was vertical, the premolar was extracted and the treatment continued. The results suggest that treatment time can be reduced if undesirable orthodontic mechanical side effects can be directed to a tooth whose extraction is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Third molar extraction is one of the most frequently performed procedures in the dental clinic, and it is associated with innumerable trans- and postoperative complications, such as pain, trismus, edema, localized alveolar osteitis, and surgical site infection. Some authors advocate the use of local or systemic antibiotics to reduce the incidence of these postoperative complications. However, several studies have revealed an insignificant gain after using antibiotics. Despite the risks of allergic reactions, toxicity, and the development of resistant microorganisms, about 50% of dentists routinely prescribe the use of prophylactic antibiotics for this purpose. The goal of this paper is to evaluate the scientific evidence that justifies antibiotic prescription to healthy patients undergoing third molar extraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter, a semiautomatic method for road extraction in object space is proposed that combines a stereoscopic pair of low-resolution aerial images with a digital terrain model (DTM) structured as a triangulated irregular network (TIN). First, we formulate an objective function in the object space to allow the modeling of roads in 3-D. In this model, the TIN-based DTM allows the search for the optimal polyline to be restricted along a narrow band that is overlaid upon it. Finally, the optimal polyline for each road is obtained by optimizing the objective function using the dynamic programming optimization algorithm. A few seed points need to be supplied by an operator. To evaluate the performance of the proposed method, a set of experiments was designed using two stereoscopic pairs of low-resolution aerial images and a TIN-based DTM with an average resolution of 1 m. The experimental results showed that the proposed method worked properly, even when faced with anomalies along roads, such as obstructions caused by shadows and trees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo compare the sequential healing at immediately loaded implants installed in a healed alveolar bony ridge or immediately after tooth extraction.Material and methodsIn the mandible of 12 dogs, the second premolars were extracted. After 3months, the mesial roots of the third premolars were endodontically treated and the distal roots extracted. Implants were placed immediately into the extraction sockets (test) and in the second premolar region (control). Crowns were applied at the second and third maxillary premolars, and healing abutments of appropriate length were applied at both implants placed in the mandible and adapted to allow occlusal contacts with the crowns in the maxilla. The time of surgery and time of sacrifices were planned in such a way to obtain biopsies representing the healing after 1 and 2weeks and 1 and 3months. Ground sections were prepared for histological analyses.ResultsAt the control sites, a resorption of the buccal bone of 1mm was found after 1week and remained stable thereafter. At the test sites, the resorption was 0.4mm at 1-week period and further loss was observed after 1month. The height of the peri-implant soft tissue was 3.8mm both at test and control sites. Higher values of mineralized bone-to-implant contact and bone density were seen at the controls compared with the test sites. The differences, however, were not statistically significant.ConclusionsDifferent patterns of sequential early healing were found at implants installed in healed alveolar bone or in alveolar sockets immediately after tooth extractions. However, three months after implant installation, no statistically significant differences were found for the hard- and soft-tissue dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a method is proposed to refine the LASER 3D roofs geometrically by using a high-resolution aerial image and Markov Random Field (MRF) models. In order to do so, a MRF description for grouping straight lines is developed, assuming that each projected side contour and ridge is topologically correct and that it is only necessary to improve its accuracy. Although the combination of laser data with data from image is most justified for refining roof contour, the structure of ridges can give greater robustness in the topological description of the roof structure. The MRF model is formulated based on relationships (length, proximity, and orientation) between the straight lines extracted from the image and projected polygon and also on retangularity and corner injunctions. The energy function associated with MRF is minimized by the genetic algorithm optimization method, resulting in the grouping of straight lines for each roof object. Finally, each grouping of straight lines is topologically reconstructed based on the topology of the corresponding LASER scanning polygon projected onto the image-space. The results obtained were satisfactory. This method was able to provide polygons roof refined buildings in which most of its contour sides and ridges were geometrically improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is intended to study the possibility of adding an amount of waste from iron mining in the ceramic mass. Clay and coal, from Vale do Paraiba, Sao Paulo, Brazil, were used in this research. These raw materials are used in the ceramic block manufacture. Clay and waste were analyzed by X-ray fluorescence and X-ray diffraction, particle size, differential thermal and thermogravimetric analysis. Liquid limit and plasticity index tests were performed in order to determine the amount of waste that which should be used in the ceramic mass. After determining the amount of waste, all samples were uniaxially pressed and sintered at 900 degrees C. Surface roughness measurements, apparent porosity and bulk density technique and three-point flexural tests were also performed to characterize the samples. The results showed that by adding the exact amount of waste, which was determined by the essays, it is possible to manufacture solid bricks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)