950 resultados para Computational fluid dynamics modeling


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerical models of the atmosphere combine a dynamical core, which approximates solutions to the adiabatic, frictionless governing equations for fluid dynamics, with tendencies arising from the parametrization of other physical processes. Since potential vorticity (PV) is conserved following fluid flow in adiabatic, frictionless circumstances, it is possible to isolate the effects of non-conservative processes by accumulating PV changes in an air-mass relative framework. This “PV tracer technique” is used to accumulate separately the effects on PV of each of the different non-conservative processes represented in a numerical model of the atmosphere. Dynamical cores are not exactly conservative because they introduce, explicitly or implicitly, some level of dissipation and adjustment of prognostic model variables which acts to modify PV. Here, the PV tracers technique is extended to diagnose the cumulative effect of the non-conservation of PV by a dynamical core and its characteristics relative to the PV modification by parametrized physical processes. Quantification using the Met Office Unified Model reveals that the magnitude of the non-conservation of PV by the dynamical core is comparable to those from physical processes. Moreover, the residual of the PV budget, when tracing the effects of the dynamical core and physical processes, is at least an order of magnitude smaller than the PV tracers associated with the most active physical processes. The implication of this work is that the non-conservation of PV by a dynamical core can be assessed in case studies with a full suite of physics parametrizations and directly compared with the PV modification by parametrized physical processes. The nonconservation of PV by the dynamical core is shown to move the position of the extratropical tropopause while the parametrized physical processes have a lesser effect at the tropopause level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Weakly nonlinear interactions among equatorial waves have been explored in this paper using the adiabatic version of the equatorial beta-plane primitive equations in isobaric coordinates. Assuming rigid lid vertical boundary conditions, the conditions imposed at the surface and at the top of the troposphere were expanded in a Taylor series around two isobaric surfaces in an approach similar to that used in the theory of surface-gravity waves in deep water and capillary-gravity waves. By adopting the asymptotic method of multiple time scales, the equatorial Rossby, mixed Rossby-gravity, inertio-gravity, and Kelvin waves, as well as their vertical structures, were obtained as leading-order solutions. These waves were shown to interact resonantly in a triad configuration at the O(epsilon) approximation. The resonant triads whose wave components satisfy a resonance condition for their vertical structures were found to have the most significant interactions, although this condition is not excluding, unlike the resonant conditions for the zonal wavenumbers and meridional modes. Thus, the analysis has focused on such resonant triads. In general, it was found that for these resonant triads satisfying the resonance condition in the vertical direction, the wave with the highest absolute frequency always acts as an energy source (or sink) for the remaining triad components, as usually occurs in several other physical problems in fluid dynamics. In addition, the zonally symmetric geostrophic modes act as catalyst modes for the energy exchanges between two dispersive waves in a resonant triad. The integration of the reduced asymptotic equations for a single resonant triad shows that, for the initial mode amplitudes characterizing realistic magnitudes of atmospheric flow perturbations, the modes in general exchange energy on low-frequency (intraseasonal and/or even longer) time scales, with the interaction period being dependent upon the initial mode amplitudes. Potential future applications of the present theory to the real atmosphere with the inclusion of diabatic forcing, dissipation, and a more realistic background state are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research, the drying process of acerola waste was investigated by using a spouted bed drier. The process was conducted using high density polyethylene inert particles with the objective of producing an ascorbic acid-rich final product. The fruit waste was ground and used to prepare different water-maltodextrin suspensions. Initially, fluidynamical experiments were conducted in order to evaluate the feeding effect on the spouted bed drier fluidynamics behavior. The experimental planning 23 + 3 was used to investigate the effect of the following variables: solids concentration, drying air temperature, intermittence time, production efficiency, solids retention and product losses by elutriation of fine particles on drier walls. The effect of selected independent variables on the drier stability was also evaluated based on a parameter defined as the ratio between the feed suspension volume and the total inert particles volume. Finally, the powder quality was verified in experiments with fixed feed flow and varying air drying temperature, drying air velocity and intermittence time. It was observed that the suspension interferes in the spouted bed drier fluidynamics behavior, and higher air flow is necessary to stabilize the drier. The suspension also promotes the expansion of the spouted bed diameter, decreases the solid circulation and favors the air distribution at the flush area. All variables interfere in the spouted bed performance, and the solids concentration has a major effect on the material retention and losses. The intermittence time also has great effect on the stability and material retention. When it comes to production efficiency, the main effect observed was the drying air temperature. First order models were well adjusted to retention and losses data. The acerola powder presented ascorbic acid levels around 600 to 700 mg/100g. Similar moisture and ascorbic acid levels were obtained for powders obtained by spouted bed and spray drier. However, the powder production efficiency of the spray drier was lower when compared to spouted bed drier. When it comes to energetic analysis, the spray drier process was superior. The results obtained for spouted bed drier are promising and highly dependent on the operational parameters chosen, but in general, it is inferred that this drying process is adequate for paste and suspension drying

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dispersion of pollutants in the environment is an issue of great interest as it directly affects air quality, mainly in large cities. Experimental and numerical tools have been used to predict the behavior of pollutant species dispersion in the atmosphere. A software has been developed based on the control-volume based on the finite element method in order to obtain two-dimensional simulations of Navier-Stokes equations and heat or mass transportation in regions with obstacles, varying position of the pollutant source. Numeric results of some applications were obtained and, whenever possible, compared with literature results showing satisfactory accordance. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the dynamics of the noncommutative fluid in the Snyder space perturbatively at the first order in powers of the noncommutative parameter. The linearized noncommutative fluid dynamics is described by a system of coupled linear partial differential equations in which the variables are the fluid density and the fluid potentials. We show that these equations admit a set of solutions that are monochromatic plane waves for the fluid density and two of the potentials and a linear function for the third potential. The energy-momentum tensor of the plane waves is calculated. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Física - IFT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Educação Matemática - IGCE

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A linhaça é a semente da planta do linho (Linum usitatissimum L.), uma espécie polimorfa originária do linho, sendo considerada uma das 6 plantas atualmente reconhecidas pelo Instituto Nacional do Câncer dos Estados Unidos (US National Cancer Institute - NCI) por suas propriedades específicas no combate ao câncer. Parte desse reconhecimento deve-se a notável característica de ser a fonte mais rica de precursores de lignina (esteróide vegetal de ação análoga ao estrógeno de mamíferos) na dieta humana. A variedade utilizada neste trabalho foi a “Linseed” de cor marrom e o objetivo deste trabalho foi analisar a fluidodinâmica dessa partícula em leito de jorro, estabelecida pelas medidas de tomadas de queda de pressão no leito a partir das deflexões em relação às velocidades de ar crescente e decrescente, obtendo assim informações para a determinação de parâmetros correlacionados ao processo, como: velocidade de mínimo jorro, queda de pressão máxima, queda de pressão no jorro estável e queda de pressão no mínimo jorro. Estes valores foram comparados aos correspondentes valores obtidos por equações empíricas citadas na literatura. Foi também avaliado o comportamento da secagem da matéria prima, mediante um planejamento estatístico 22, tendo com as variáveis de entrada temperatura do gás (Tg) e o tempo de operação (t), para a quantificação das variáveis de resposta razão de umidade (Xr, adim.), germinação (G, %) e o índice de velocidade de germinação (IVG, t-1) e analisadas estatisticamente pelo planejamento fatorial completo com três repetições no ponto central. A cinética de secagem das sementes de linhaça, previamente umidificadas, foi realizada nas temperaturas de 45, 55 e 65 °C, e dentre os três modelos propostos, o modelo de Midilli et al., foi que melhor descreveu aos dados experimentais. Para os parâmetros fluidodinâmicos observou-se que a correlação de Gorshtein e Mukhlenov (1965) apresentou os menores desvios para queda e pressão de mínimo jorro e jorro estável, Abdelrazek (1969) apresentou o menor desvio para a velocidade no mínimo jorro e Pallai e Németh (1969) descreveu adequadamente a queda de pressão máxima. Foi observado que a carga de sementes e a temperatura exerceram influência significativa nos parâmetros fluidodinâmicos em leito de jorro. Com base na análise do planejamento estatístico proposto pode-se concluir que os parâmetros de entrada temperatura do gás e tempo de operação exerceram influência significativa sobre todas as variáveis de resposta, sendo observada influência quadrática das variáveis de entrada ao se observar a significância da curvatura sobre os parâmetros: Razão de umidade, Germinação e Índice de Velocidade de Germinação, propondo-se modelos representativos destes parâmetros com a presença da curvatura, apresentando um coeficiente de determinação (R2) superior a 99 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to study the thermal aspects involved in a liquid cooling system for processors, analyzing their competitiveness and efficiency across the fins and fan system usually used by personal computers, because electronic components become more potent and consequently current methods of cooling are becoming ineffective. The liquid cooling system and air cooling system have different heat transfer mechanisms that involve mainly convection and conduction heat transfer modes, and, furthermore, requires an analysis of fluid dynamics, which can evaluate the losses involved in the closed system, consisting in an exchanger heat pipe and water blocks in liquid cooling system or heat sink and turbo-axial fan in the air cooling system