995 resultados para Commercial Radio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A vaginally-worn temperature telemeter may be used by women to chart their basal body temperature for ovulation detection. The telemeter uses a temperature to pulse width converter to key a Colpitts oscillator which is controlled in frequency by a 418 MHz SAW resonator. The circuit’s tank inductor acts as a compact, multi-turn loop antenna with a radiated power in isolation of around 1 uW. The transmission characteristics of the system are affected by the proximity of the human body, which acts as an electrically-large lossy dielectric. The RF link-budget must allow for the reduction in total emitted power, directional body-induced fading, and polarization effects. The polar power patterns of the telemeter were measured for both isolated and in-situ cases, using horizontal and vertical polarization. The power patterns were numerically integrated to determine relative emitted power, and a reference dipole used to determine the emitted power for the isolated device. In isolation the telemeter radiation is vertically polarized and isotropic in nature. With the telemeter in-situ, total body absorption was found to be over 20 dB, with directional fades of up to 40 dB; there was extensive cross-polarization, with up to 60% of radiated power horizontally polarized. With limited radiated power and directional fading, the operating range for the telemeter is limited to single room operation (less than 10m). The majority of RF radiation is absorbed by the body, but the radiation hazard is negligible due to the low power level of the device. The high level of cross-polarization suggests that either horizontal or vertically polarized base-station antennas may be used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radio-based signalling devices will play an important role in future generations of remote patient monitoring equipment, both at home and in hospital. Ultimately, it will be possible to sample vital signs frompatients, whatever their location and without them necessarily being aware that a measurement is being taken. This paper reviews currentmethods for the transmission by radio of physiological parameters over ranges of 0.3, 3 and 30 m, and describes the radiofrequency hardware required and the carrier frequencies commonly used. Future developments, including full duplex systems and the use of more advanced modulation schemes, are described. The paper concludeswith a case studyof a humantemperature telemeter built to indicateovulation. Clinical results clearly show the advantage to be had in adopting radio biotelemetry in this instance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigations were undertaken to identify causes for the occurrence of high levels of the zootechnical feed additive nicarbazin in broiler liver at slaughter. The first investigation on 32 commercial broiler flocks involved sampling and analysis for nicarbazin ( as dinitrocarbanilide, DNC) in liver from birds during a 3-10-day period after withdrawal of nicarbazin from their feed and before commercial slaughter. DNC residues in liver samples of broilers scheduled as being withdrawn from nicarbazin for >= 6 days ranged from 20 to > 1600 mu g kg(-1) ( the specified withdrawal period for nicarbazin is 5 days and the Joint Expert Committee on Food Additives (JECFA)maximum residue limit (MRL) is 200 mu g kg(-1) liver). Further on-farm investigations on 12 of these flocks, selected on the basis of the feeding system in use and the levels of DNC residues determined in liver, identified issues in feed management contributing to elevated residues in broiler liver. A significant correlation (0.81, p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several commercial titania photocatalyst powders were formed into thin (ca. 350 mu m), 25 mm diameter ceramic wafers, sputter deposited with Pt on one side. The activities of each of the ceramic wafers were tested for hydrogen and oxygen evolution from aqueous sacrificial systems. The commercial sample PC50 (Millennium Chemicals, UK) yielded reproducible ceramic wafers with high activity for water photoreduction. Many of the ceramic wafers displayed low water photo-oxidation activities; however, these were greatly increased with addition of a NiO co-catalyst. In a selected case, hydrogen evolution activity was compared between a PC50 wafer and an identical weight of platinised PC50 powder suspension. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The major current commercial applications of semiconductor photochemistry promoted on the world wide web are reviewed. The basic principles behind the different applications are discussed, including the use of semiconductor photochemistry to: photo-mineralise organics, photo-sterilise and photo-demist. The range of companies, and their products, which utilise semiconductor photochemistry are examined and typical examples listed. An analysis of the geographical distribution of current commercial activity in this area is made. The results indicate that commercial activity in this area is growing world-wide, but is especially strong in Japan. The number and geographical distribution of patents in semiconductor photocatalysis are also commented on. The trends in the numbers of US and Japanese patents over the last 6 years are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photocatalytic efficiencies of laboratory made and commercial TiO2 samples were compared using a standard test reaction: the photomineralization of 4-chlorophenol (4-CP) to CO2, H2O and HCl mediated by Degussa P25 TiO2 in a batch reactor. The results show that the rate of photodegradation of 4-CP, sensitized by a sample of TiO2, shows no clear simple dependence on physical characteristics such as the degree of crystallinity, the surface area and the percentage of H2O.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: