987 resultados para Colony forming units
Resumo:
A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
The best places to locate the Gas Supply Units (GSUs) on a natural gas systems and their optimal allocation to loads are the key factors to organize an efficient upstream gas infrastructure. The number of GSUs and their optimal location in a gas network is a decision problem that can be formulated as a linear programming problem. Our emphasis is on the formulation and use of a suitable location model, reflecting real-world operations and constraints of a natural gas system. This paper presents a heuristic model, based on lagrangean approach, developed for finding the optimal GSUs location on a natural gas network, minimizing expenses and maximizing throughput and security of supply.The location model is applied to the Iberian high pressure natural gas network, a system modelised with 65 demand nodes. These nodes are linked by physical and virtual pipelines – road trucks with gas in liquefied form. The location model result shows the best places to locate, with the optimal demand allocation and the most economical gas transport mode: by pipeline or by road truck.
Resumo:
Natural gas industry has been confronted with big challenges: great growth in demand, investments on new GSUs – gas supply units, and efficient technical system management. The right number of GSUs, their best location on networks and the optimal allocation to loads is a decision problem that can be formulated as a combinatorial programming problem, with the objective of minimizing system expenses. Our emphasis is on the formulation, interpretation and development of a solution algorithm that will analyze the trade-off between infrastructure investment expenditure and operating system costs. The location model was applied to a 12 node natural gas network, and its effectiveness was tested in five different operating scenarios.
Resumo:
To maintain a power system within operation limits, a level ahead planning it is necessary to apply competitive techniques to solve the optimal power flow (OPF). OPF is a non-linear and a large combinatorial problem. The Ant Colony Search (ACS) optimization algorithm is inspired by the organized natural movement of real ants and has been successfully applied to different large combinatorial optimization problems. This paper presents an implementation of Ant Colony optimization to solve the OPF in an economic dispatch context. The proposed methodology has been developed to be used for maintenance and repairing planning with 48 to 24 hours antecipation. The main advantage of this method is its low execution time that allows the use of OPF when a large set of scenarios has to be analyzed. The paper includes a case study using the IEEE 30 bus network. The results are compared with other well-known methodologies presented in the literature.
Resumo:
The paper introduces an approach to solve the problem of generating a sequence of jobs that minimizes the total weighted tardiness for a set of jobs to be processed in a single machine. An Ant Colony System based algorithm is validated with benchmark problems available in the OR library. The obtained results were compared with the best available results and were found to be nearer to the optimal. The obtained computational results allowed concluding on their efficiency and effectiveness.
Resumo:
Swarm Intelligence generally refers to a problem-solving ability that emerges from the interaction of simple information-processing units. The concept of Swarm suggests multiplicity, distribution, stochasticity, randomness, and messiness. The concept of Intelligence suggests that problem-solving approach is successful considering learning, creativity, cognition capabilities. This paper introduces some of the theoretical foundations, the biological motivation and fundamental aspects of swarm intelligence based optimization techniques such Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO) and Artificial Bees Colony (ABC) algorithms for scheduling optimization.
Resumo:
OBJECTIVE: To identify potential prognostic factors for neonatal mortality among newborns referred to intensive care units. METHODS: A live-birth cohort study was carried out in Goiânia, Central Brazil, from November 1999 to October 2000. Linked birth and infant death certificates were used to ascertain the cohort of live born infants. An additional active surveillance system of neonatal-based mortality was implemented. Exposure variables were collected from birth and death certificates. The outcome was survivors (n=713) and deaths (n=162) in all intensive care units in the study period. Cox's proportional hazards model was applied and a Receiver Operating Characteristic curve was used to compare the performance of statistically significant variables in the multivariable model. Adjusted mortality rates by birth weight and 5-min Apgar score were calculated for each intensive care unit. RESULTS: Low birth weight and 5-min Apgar score remained independently associated to death. Birth weight equal to 2,500g had 0.71 accuracy (95% CI: 0.65-0.77) for predicting neonatal death (sensitivity =72.2%). A wide variation in the mortality rates was found among intensive care units (9.5-48.1%) and two of them remained with significant high mortality rates even after adjusting for birth weight and 5-min Apgar score. CONCLUSIONS: This study corroborates birth weight as a sensitive screening variable in surveillance programs for neonatal death and also to target intensive care units with high mortality rates for implementing preventive actions and interventions during the delivery period.
Resumo:
In this paper a solution to an highly constrained and non-convex economical dispatch (ED) problem with a meta-heuristic technique named Sensing Cloud Optimization (SCO) is presented. The proposed meta-heuristic is based on a cloud of particles whose central point represents the objective function value and the remaining particles act as sensors "to fill" the search space and "guide" the central particle so it moves into the best direction. To demonstrate its performance, a case study with multi-fuel units and valve- point effects is presented.
Resumo:
Mestrado (PES II), Educação Pré-Escolar e Ensino do 1º Ciclo do Ensino Básico, 3 de Julho de 2014, Universidade dos Açores.
Resumo:
The Late Miocene Malbusca outcrop is located in the southeastern coast of Santa Maria Island (Azores, NE Atlantic), interspersed in volcanic formations. At ~20 meters above present sea level, a prominent discontinuous layer of rhodoliths seizes with an extension of ~250 meters. This paper presents the first taxonomic record of fossil rhodolith forming coralline algae for the Miocene of the Azores. The preserved taxonomic features used were the following: (1) arrangement of basal filaments, (2) epithallial cells (when observable), (3) presence of cell fusions, (4) conceptacle type, (5) number of cells layers which conceptacle chamber floors are situated below the surrounding thallus surface and (6) for the sporangial pores, the orientation of the filaments around the conceptacle pores. Based on these characters, six taxa were identified encompassing three Corallinaceae (Lithophyllum prototypum, Lithophyllum sp., Spongites sp., Hydrolithon sp.) and one Hapalidaceae (Phymatolithon calcareum and cf. Phymatolithon sp.). An unidentified coaxial thallus was also present, the coaxial construction ascribing the specimens to the genus Mesophyllum or Neogoniolithon. Taxonomic accounts for the identified taxa are described, illustrated and an identification key is provided. The report of L prototypum represents the first Miocene record and the preservation of the specimens is very good. Miocene coralline algae seem very consistent among deposits but some species are relevant for particular areas, like in the Azores.
Resumo:
The impact of mycotoxins on human and animal health is well recognized. Aflatoxin B1 (AFB1) is by far the most prevalent and the most potent natural carcinogen and is usually the major aflatoxin produced by toxigenic fungal strains. Data available, points to an increasing frequency of poultry feed contamination by aflatoxins. Since aflatoxin residues may accumulate in body tissues, this represents a high risk to human health. Samples from commercial poultry birds have already presented detectable levels of aflatoxin in liver. A descriptive study was developed in order to assess fungal contamination by species from Aspergillus flavus complex in seven Portuguese poultry units. Air fungal contamination was studied by conventional and molecular methods. Air, litter and surfaces samples were collected. To apply molecular methods, air samples of 300L were collected using the Coriolis μ air sampler (Bertin Technologies), at 300 L/min airflow rate. For conventional methodologies, all the collected samples were incubated at 27ºC for five to seven days. Through conventional methods, Aspergillus flavus was the third fungal species (7%) most frequently found in 27 indoor air samples analysed and the most commonly isolated species (75%) in air samples containing only the Aspergillus genus...
Resumo:
Solvent extraction is considered as a multi-criteria optimization problem, since several chemical species with similar extraction kinetic properties are frequently present in the aqueous phase and the selective extraction is not practicable. This optimization, applied to mixer–settler units, considers the best parameters and operating conditions, as well as the best structure or process flow-sheet. Global process optimization is performed for a specific flow-sheet and a comparison of Pareto curves for different flow-sheets is made. The positive weight sum approach linked to the sequential quadratic programming method is used to obtain the Pareto set. In all investigated structures, recovery increases with hold-up, residence time and agitation speed, while the purity has an opposite behaviour. For the same treatment capacity, counter-current arrangements are shown to promote recovery without significant impairment in purity. Recycling the aqueous phase is shown to be irrelevant, but organic recycling with as many stages as economically feasible clearly improves the design criteria and reduces the most efficient organic flow-rate.
Resumo:
Objectives - This study intended to characterize work environment contamination by particles in 2 waste-sorting plants. Material and Methods - Particles were measured by portable direct-reading equipment. Besides mass concentration in different sizes, data related with the number of particles concentration were also obtained. Results - Both sorting units showed the same distribution concerning the 2 exposure metrics: particulate matter 5 (PM5) and particulate matter 10 (PM10) reached the highest levels and 0.3 μm was the fraction with a higher number of particles. Unit B showed higher (p < 0.05) levels for both exposure metrics. For instance, in unit B the PM10 size is 9-fold higher than in unit A. In unit A, particulate matter values obtained in pre-sorting and in the sequential sorting cabinet were higher without ventilation working. Conclusions - Workers from both waste-sorting plants are exposed to particles. Particle counting provided additional information that is of extreme value for analyzing the health effects of particles since higher values of particles concentration were obtained in the smallest fraction.
Resumo:
OBJECTIVE: To describe the implantation and the effects of directly-observed treatment short course (DOTS) in primary health care units. METHODS: Interviews were held with the staff of nine municipal health care units (MHU) that provided DOTS in Rio de Janeiro City, Southeastern Brazil, in 2004-2005. A dataset with records of all tuberculosis treatments beginning in 2004 in all municipal health care units was collected. Bivariate analyses and a multinomial model were applied to identify associations between treatment outcomes and demographic and treatment process variables, including being in DOTS or self-administered therapy (SAT). RESULTS: From 4,598 tuberculosis cases treated in public health units administrated by the municipality, 1,118 (24.3%) were with DOTS and 3,480 (75.7%) with SAT. The odds of DOTS were higher among patients with age under 50 years, tuberculosis relapse and prior history of default or treatment failure. The odds of death were 52.0% higher among patients on DOTS as compared to SAT. DOTS modality including community health workers (CHWs) showed the highest treatment success rate. A reduction of 21.0% was observed in the odds of default (vs. cure) among patients on DOTS as compared to patients on SAT, and a reduction of 64.0% among patients on DOTS with CHWs as compared to those without CHWs. CONCLUSIONS: Patients with a "low compliance profile" were more likely to be included in DOTS. This strategy improves the quality of care provided to tuberculosis patients, although the proposed goals were not achieved.