972 resultados para CT, Radiation Dose, Image Quality


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Simultaneous Multiple Surface (SMS) method in planar geometry (2D) is applied to imaging designs, generating lenses that compare well with aplanatic designs. When the merit function utilizes image quality over the entire field (not just paraxial), the SMS strategy is superior. In fact, the traditional aplanatic approach is actually a particular case of the SMS strategy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta tesis analiza los elementos que afectan a la evaluación del rendimiento dentro de la técnica de radiodiagnóstico mediante tomografía por emisión de positrones (PET), centrándose en escáneres preclínicos. Se exploran las posibilidades de los protocolos estándar de evaluación sobre los siguientes aspectos: su uso como herramienta para validar programas de simulación Montecarlo, como método para la comparación de escáneres y su validez en el estudio del efecto sobre la calidad de imagen al utilizar radioisótopos alternativos. Inicialmente se estudian los métodos de evaluación orientados a la validación de simulaciones PET, para ello se presenta el programa GAMOS como entorno de simulación y se muestran los resultados de su validación basada en el estándar NEMA NU 4-2008 para escáneres preclínicos. Esta validación se ha realizado mediante la comparación de los resultados simulados frente a adquisiciones reales en el equipo ClearPET, describiendo la metodología de evaluación y selección de los parámetros NEMA. En este apartado también se mencionan las aportaciones desarrolladas en GAMOS para aplicaciones PET, como la inclusión de herramientas para la reconstrucción de imágenes. Por otro lado, la evaluación NEMA del ClearPET es utilizada para comparar su rendimiento frente a otro escáner preclínico: el sistema rPET-1. Esto supone la primera caracterización NEMA NU 4 completa de ambos equipos; al mismo tiempo que se analiza cómo afectan las importantes diferencias de diseño entre ellos, especialmente el tamaño axial del campo de visión y la configuración de los detectores. El 68Ga es uno de los radioisótopos no convencionales en imagen PET que está experimentando un mayor desarrollo, sin embargo, presenta la desventaja del amplio rango o distancia recorrida por el positrón emitido. Además del rango del positrón, otra propiedad física característica de los radioisótopos PET que puede afectar a la imagen es la emisión de fotones gamma adicionales, tal como le ocurre al isótopo 48V. En esta tesis se evalúan dichos efectos mediante estudios de resolución espacial y calidad de imagen NEMA. Finalmente, se analiza el alcance del protocolo NEMA NU 4-2008 cuando se utiliza para este propósito, adaptándolo a tal fin y proponiendo posibles modificaciones. Abstract This thesis analyzes the factors affecting the performance evaluation in positron emission tomography (PET) imaging, focusing on preclinical scanners. It explores the possibilities of standard protocols of assessment on the following aspects: their use as tools to validate Monte Carlo simulation programs, their usefulness as a method for comparing scanners and their validity in the study of the effect of alternative radioisotopes on image quality. Initially we study the methods of performance evaluation oriented to validate PET simulations. For this we present the GAMOS program as a simulation framework and show the results of its validation based on the standard NEMA NU 4-2008 for preclinical PET scanners. This has been accomplished by comparing simulated results against experimental acquisitions in the ClearPET scanner, describing the methodology for the evaluation and selection of NEMA parameters. This section also mentions the contributions developed in GAMOS for PET applications, such as the inclusion of tools for image reconstruction. Furthermore, the evaluation of the ClearPET scanner is used to compare its performance against another preclinical scanner, specifically the rPET-1 system. This is the first complete NEMA NU 4 based characterization study of both systems. At the same time we analyze how do the significant design differences of these two systems, especially the size of the axial field of view and the detectors configuration affect their performance characteristics. 68Ga is one of the unconventional radioisotopes in PET imaging the use of which is currently significantly increasing; however, it presents the disadvantage of the long positron range (distance traveled by the emitted positron before annihilating with an electron). Besides the positron range, additional gamma photon emission is another physical property characteristic of PET radioisotopes that can affect the reconstructed image quality, as it happens to the isotope 48V. In this thesis we assess these effects through studies of spatial resolution and image quality. Finally, we analyze the scope of the NEMA NU 4-2008 to carry out such studies, adapting it and proposing possible modifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Classical imaging optics has been developed over centuries in many areas, such as its paraxial imaging theory and practical design methods like multi-parametric optimization techniques. Although these imaging optical design methods can provide elegant solutions to many traditional optical problems, there are more and more new design problems, like solar concentrator, illumination system, ultra-compact camera, etc., that require maximum energy transfer efficiency, or ultra-compact optical structure. These problems do not have simple solutions from classical imaging design methods, because not only paraxial rays, but also non-paraxial rays should be well considered in the design process. Non-imaging optics is a newly developed optical discipline, which does not aim to form images, but to maximize energy transfer efficiency. One important concept developed from non-imaging optics is the “edge-ray principle”, which states that the energy flow contained in a bundle of rays will be transferred to the target, if all its edge rays are transferred to the target. Based on that concept, many CPC solar concentrators have been developed with efficiency close to the thermodynamic limit. When more than one bundle of edge-rays needs to be considered in the design, one way to obtain solutions is to use SMS method. SMS stands for Simultaneous Multiple Surface, which means several optical surfaces are constructed simultaneously. The SMS method was developed as a design method in Non-imaging optics during the 90s. The method can be considered as an extension to the Cartesian Oval calculation. In the traditional Cartesian Oval calculation, one optical surface is built to transform an input wave-front to an out-put wave-front. The SMS method however, is dedicated to solve more than 1 wave-fronts transformation problem. In the beginning, only 2 input wave-fronts and 2 output wave-fronts transformation problem was considered in the SMS design process for rotational optical systems or free-form optical systems. Usually “SMS 2D” method stands for the SMS procedure developed for rotational optical system, and “SMS 3D” method for the procedure for free-form optical system. Although the SMS method was originally employed in non-imaging optical system designs, it has been found during this thesis that with the improved capability to design more surfaces and control more input and output wave-fronts, the SMS method can also be applied to imaging system designs and possesses great advantage over traditional design methods. In this thesis, one of the main goals to achieve is to further develop the existing SMS-2D method to design with more surfaces and improve the stability of the SMS-2D and SMS-3D algorithms, so that further optimization process can be combined with SMS algorithms. The benefits of SMS plus optimization strategy over traditional optimization strategy will be explained in details for both rotational and free-form imaging optical system designs. Another main goal is to develop novel design concepts and methods suitable for challenging non-imaging applications, e.g. solar concentrator and solar tracker. This thesis comprises 9 chapters and can be grouped into two parts: the first part (chapter 2-5) contains research works in the imaging field, and the second part (chapter 6-8) contains works in the non-imaging field. In the first chapter, an introduction to basic imaging and non-imaging design concepts and theories is given. Chapter 2 presents a basic SMS-2D imaging design procedure using meridian rays. In this chapter, we will set the imaging design problem from the SMS point of view, and try to solve the problem numerically. The stability of this SMS-2D design procedure will also be discussed. The design concepts and procedures developed in this chapter lay the path for further improvement. Chapter 3 presents two improved SMS 3 surfaces’ design procedures using meridian rays (SMS-3M) and skew rays (SMS-1M2S) respectively. The major improvement has been made to the central segments selections, so that the whole SMS procedures become more stable compared to procedures described in Chapter 2. Since these two algorithms represent two types of phase space sampling, their image forming capabilities are compared in a simple objective design. Chapter 4 deals with an ultra-compact SWIR camera design with the SMS-3M method. The difficulties in this wide band camera design is how to maintain high image quality meanwhile reduce the overall system length. This interesting camera design provides a playground for the classical design method and SMS design methods. We will show designs and optical performance from both classical design method and the SMS design method. Tolerance study is also given as the end of the chapter. Chapter 5 develops a two-stage SMS-3D based optimization strategy for a 2 freeform mirrors imaging system. In the first optimization phase, the SMS-3D method is integrated into the optimization process to construct the two mirrors in an accurate way, drastically reducing the unknown parameters to only few system configuration parameters. In the second optimization phase, previous optimized mirrors are parameterized into Qbfs type polynomials and set up in code V. Code V optimization results demonstrates the effectiveness of this design strategy in this 2-mirror system design. Chapter 6 shows an etendue-squeezing condenser optics, which were prepared for the 2010 IODC illumination contest. This interesting design employs many non-imaging techniques such as the SMS method, etendue-squeezing tessellation, and groove surface design. This device has theoretical efficiency limit as high as 91.9%. Chapter 7 presents a freeform mirror-type solar concentrator with uniform irradiance on the solar cell. Traditional parabolic mirror concentrator has many drawbacks like hot-pot irradiance on the center of the cell, insufficient use of active cell area due to its rotational irradiance pattern and small acceptance angle. In order to conquer these limitations, a novel irradiance homogenization concept is developed, which lead to a free-form mirror design. Simulation results show that the free-form mirror reflector has rectangular irradiance pattern, uniform irradiance distribution and large acceptance angle, which confirm the viability of the design concept. Chapter 8 presents a novel beam-steering array optics design strategy. The goal of the design is to track large angle parallel rays by only moving optical arrays laterally, and convert it to small angle parallel output rays. The design concept is developed as an extended SMS method. Potential applications of this beam-steering device are: skylights to provide steerable natural illumination, building integrated CPV systems, and steerable LED illumination. Conclusion and future lines of work are given in Chapter 9. Resumen La óptica de formación de imagen clásica se ha ido desarrollando durante siglos, dando lugar tanto a la teoría de óptica paraxial y los métodos de diseño prácticos como a técnicas de optimización multiparamétricas. Aunque estos métodos de diseño óptico para formación de imagen puede aportar soluciones elegantes a muchos problemas convencionales, siguen apareciendo nuevos problemas de diseño óptico, concentradores solares, sistemas de iluminación, cámaras ultracompactas, etc. que requieren máxima transferencia de energía o dimensiones ultracompactas. Este tipo de problemas no se pueden resolver fácilmente con métodos clásicos de diseño porque durante el proceso de diseño no solamente se deben considerar los rayos paraxiales sino también los rayos no paraxiales. La óptica anidólica o no formadora de imagen es una disciplina que ha evolucionado en gran medida recientemente. Su objetivo no es formar imagen, es maximazar la eficiencia de transferencia de energía. Un concepto importante de la óptica anidólica son los “rayos marginales”, que se pueden utilizar para el diseño de sistemas ya que si todos los rayos marginales llegan a nuestra área del receptor, todos los rayos interiores también llegarán al receptor. Haciendo uso de este principio, se han diseñado muchos concentradores solares que funcionan cerca del límite teórico que marca la termodinámica. Cuando consideramos más de un haz de rayos marginales en nuestro diseño, una posible solución es usar el método SMS (Simultaneous Multiple Surface), el cuál diseña simultáneamente varias superficies ópticas. El SMS nació como un método de diseño para óptica anidólica durante los años 90. El método puede ser considerado como una extensión del cálculo del óvalo cartesiano. En el método del óvalo cartesiano convencional, se calcula una superficie para transformar un frente de onda entrante a otro frente de onda saliente. El método SMS permite transformar varios frentes de onda de entrada en frentes de onda de salida. Inicialmente, sólo era posible transformar dos frentes de onda con dos superficies con simetría de rotación y sin simetría de rotación, pero esta limitación ha sido superada recientemente. Nos referimos a “SMS 2D” como el método orientado a construir superficies con simetría de rotación y llamamos “SMS 3D” al método para construir superficies sin simetría de rotación o free-form. Aunque el método originalmente fue aplicado en el diseño de sistemas anidólicos, se ha observado que gracias a su capacidad para diseñar más superficies y controlar más frentes de onda de entrada y de salida, el SMS también es posible aplicarlo a sistemas de formación de imagen proporcionando una gran ventaja sobre los métodos de diseño tradicionales. Uno de los principales objetivos de la presente tesis es extender el método SMS-2D para permitir el diseño de sistemas con mayor número de superficies y mejorar la estabilidad de los algoritmos del SMS-2D y SMS-3D, haciendo posible combinar la optimización con los algoritmos. Los beneficios de combinar SMS y optimización comparado con el proceso de optimización tradicional se explican en detalle para sistemas con simetría de rotación y sin simetría de rotación. Otro objetivo importante de la tesis es el desarrollo de nuevos conceptos de diseño y nuevos métodos en el área de la concentración solar fotovoltaica. La tesis está estructurada en 9 capítulos que están agrupados en dos partes: la primera de ellas (capítulos 2-5) se centra en la óptica formadora de imagen mientras que en la segunda parte (capítulos 6-8) se presenta el trabajo del área de la óptica anidólica. El primer capítulo consta de una breve introducción de los conceptos básicos de la óptica anidólica y la óptica en formación de imagen. El capítulo 2 describe un proceso de diseño SMS-2D sencillo basado en los rayos meridianos. En este capítulo se presenta el problema de diseñar un sistema formador de imagen desde el punto de vista del SMS y se intenta obtener una solución de manera numérica. La estabilidad de este proceso se analiza con detalle. Los conceptos de diseño y los algoritmos desarrollados en este capítulo sientan la base sobre la cual se realizarán mejoras. El capítulo 3 presenta dos procedimientos para el diseño de un sistema con 3 superficies SMS, el primero basado en rayos meridianos (SMS-3M) y el segundo basado en rayos oblicuos (SMS-1M2S). La mejora más destacable recae en la selección de los segmentos centrales, que hacen más estable todo el proceso de diseño comparado con el presentado en el capítulo 2. Estos dos algoritmos representan dos tipos de muestreo del espacio de fases, su capacidad para formar imagen se compara diseñando un objetivo simple con cada uno de ellos. En el capítulo 4 se presenta un diseño ultra-compacto de una cámara SWIR diseñada usando el método SMS-3M. La dificultad del diseño de esta cámara de espectro ancho radica en mantener una alta calidad de imagen y al mismo tiempo reducir drásticamente sus dimensiones. Esta cámara es muy interesante para comparar el método de diseño clásico y el método de SMS. En este capítulo se presentan ambos diseños y se analizan sus características ópticas. En el capítulo 5 se describe la estrategia de optimización basada en el método SMS-3D. El método SMS-3D calcula las superficies ópticas de manera precisa, dejando sólo unos pocos parámetros libres para decidir la configuración del sistema. Modificando el valor de estos parámetros se genera cada vez mediante SMS-3D un sistema completo diferente. La optimización se lleva a cabo variando los mencionados parámetros y analizando el sistema generado. Los resultados muestran que esta estrategia de diseño es muy eficaz y eficiente para un sistema formado por dos espejos. En el capítulo 6 se describe un sistema de compresión de la Etendue, que fue presentado en el concurso de iluminación del IODC en 2010. Este interesante diseño hace uso de técnicas propias de la óptica anidólica, como el método SMS, el teselado de las lentes y el diseño mediante grooves. Este dispositivo tiene un límite teórica en la eficiencia del 91.9%. El capítulo 7 presenta un concentrador solar basado en un espejo free-form con irradiancia uniforme sobre la célula. Los concentradores parabólicos tienen numerosas desventajas como los puntos calientes en la zona central de la célula, uso no eficiente del área de la célula al ser ésta cuadrada y además tienen ángulos de aceptancia de reducido. Para poder superar estas limitaciones se propone un novedoso concepto de homogeneización de la irrandancia que se materializa en un diseño con espejo free-form. El análisis mediante simulación demuestra que la irradiancia es homogénea en una región rectangular y con mayor ángulo de aceptancia, lo que confirma la viabilidad del concepto de diseño. En el capítulo 8 se presenta un novedoso concepto para el diseño de sistemas afocales dinámicos. El objetivo del diseño es realizar un sistema cuyo haz de rayos de entrada pueda llegar con ángulos entre ±45º mientras que el haz de rayos a la salida sea siempre perpendicular al sistema, variando únicamente la posición de los elementos ópticos lateralmente. Las aplicaciones potenciales de este dispositivo son varias: tragaluces que proporcionan iluminación natural, sistemas de concentración fotovoltaica integrados en los edificios o iluminación direccionable con LEDs. Finalmente, el último capítulo contiene las conclusiones y las líneas de investigación futura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In professional video production, users have to access to huge multimedia files simultaneously in an error-free environment, this restriction force the use of expensive disk architectures for video servers. Previous researches proposed different RAID systems for each specific task (ingest, editing, file, play-out, etc.). Video production companies have to acquire different servers with different RAIDs systems in order to support each task in the production workflow. The solution has multiples disadvantages, duplicated material in several RAIDs, duplicated material for different qualities, transfer and transcoding processes, etc. In this work, an architecture for video servers based on the spreading of JPEG200 data in different RAIDs is presented, each individual part of the data structure goes to a specific RAID type depending on the effect that produces the data on the overall image quality, the method provide a redundancy correlated with the data rank. The global storage can be used in all the different tasks of the production workflow saving disk space, redundant files and transfers procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrodynamic bare-tether mission to Jupiter,following the capture of a spacecraft (SC) into an equatorial highly elliptical orbit with perijove at about 1.3 times the Jovian radius, is discussed. Repeated applications of the propellantless Lorentz drag on a spinning tether, at the perijove vicinity, can progressively lower the apojove at constant perijove, for a tour of Galilean moons. Electrical energy is generated and stored as the SC moves from an orbit at 1 : 1 resonance with a moon, down to resonance with the next moon; switching tether current off, stored power is then used as the SC makes a number of flybys of each moon. Radiation dose is calculated throughout the mission,during capture, flybys and moves between moons. The tour mission is limited by both power needs and accumulated dose. The three-stage apojove lowering down to Ganymede, Io, and Europa resonances would total less than 14 weeks, while 4 Ganymede, 20 Europa, and 16 Io flybys would add up to 18 weeks, with the entire mission taking just over seven months and the accumulated radiation dose keeping under 3 Mrad (Si) at 10-mm Al shield thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three separate scenarios of an electrodynamic tether mission at Jupiter following capture of a spacecraft (SC) into an equatorial, highly elliptical orbit around the planet, with perijove at about 1.5 times the Jovian radius, are discussed. Repeated application of Lorentz drag on the spinning tether, at the perijove vicinity, can progressively lower the apojove. One mission involves the tethered-SC rapidly and frequently visiting Galilean moons; elliptical orbits with apojove down at the Ganymede, Europa, and Io orbits are in 2:5, 4:9, and 1:2 resonances with the respective moons. About 20 slow flybys of Io would take place before the accumulated radiation dose exceeds 3 Mrad (Si) at 10 mm Al shield thickness, with a total duration of 5 months after capture (4 months for lowering the apojove to Io and one month for the flybys). The respective number of flybys for Ganymede would be 10 with a total duration of about 9 months. An alternative mission would have the SC acquire a low circular orbit around Jupiter, below the radiation belts, and manoeuvre to get an optimal altitude, with no major radiation effects, in less than 5 months after capture. In a third mission, repeated thrusting at the apojove vicinity, once down at the Io torus, would raise the perijove itself to the torus to acquire a low circular orbit around Io in about 4 months, for a total of 8 months after capture; this corresponds, however, to over 100 apojove passes with an accumulated dose, of about 8.5 Mrad (Si), that poses a critical issue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: A fully three-dimensional (3D) massively parallelizable list-mode ordered-subsets expectation-maximization (LM-OSEM) reconstruction algorithm has been developed for high-resolution PET cameras. System response probabilities are calculated online from a set of parameters derived from Monte Carlo simulations. The shape of a system response for a given line of response (LOR) has been shown to be asymmetrical around the LOR. This work has been focused on the development of efficient region-search techniques to sample the system response probabilities, which are suitable for asymmetric kernel models, including elliptical Gaussian models that allow for high accuracy and high parallelization efficiency. The novel region-search scheme using variable kernel models is applied in the proposed PET reconstruction algorithm. Methods: A novel region-search technique has been used to sample the probability density function in correspondence with a small dynamic subset of the field of view that constitutes the region of response (ROR). The ROR is identified around the LOR by searching for any voxel within a dynamically calculated contour. The contour condition is currently defined as a fixed threshold over the posterior probability, and arbitrary kernel models can be applied using a numerical approach. The processing of the LORs is distributed in batches among the available computing devices, then, individual LORs are processed within different processing units. In this way, both multicore and multiple many-core processing units can be efficiently exploited. Tests have been conducted with probability models that take into account the noncolinearity, positron range, and crystal penetration effects, that produced tubes of response with varying elliptical sections whose axes were a function of the crystal's thickness and angle of incidence of the given LOR. The algorithm treats the probability model as a 3D scalar field defined within a reference system aligned with the ideal LOR. Results: This new technique provides superior image quality in terms of signal-to-noise ratio as compared with the histogram-mode method based on precomputed system matrices available for a commercial small animal scanner. Reconstruction times can be kept low with the use of multicore, many-core architectures, including multiple graphic processing units. Conclusions: A highly parallelizable LM reconstruction method has been proposed based on Monte Carlo simulations and new parallelization techniques aimed at improving the reconstruction speed and the image signal-to-noise of a given OSEM algorithm. The method has been validated using simulated and real phantoms. A special advantage of the new method is the possibility of defining dynamically the cut-off threshold over the calculated probabilities thus allowing for a direct control on the trade-off between speed and quality during the reconstruction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrodynamic bare tether is shown to allow carrying out scientific observations very close to Jupiter, for exploration of its surface and subsurface, and ionospheric and atmospheric in-situ measurements. Starting at a circular equatorial orbit of radius about 1.3/1.4 times the Jovian radius, continuous propellantless Lorentz drag on a thin-tape tether in the 1-5 km length range would make a spacecraft many times as heavy as the tape slowly spiral in, over a period of many months, while generating power at a load plugged in the tether circuit for powering instruments in science data acquisition and transmission. Lying under the Jovian radiation belts, the tape would avoid the most severe problem facing tethers in Jupiter, which are capable of producing both power and propulsion but, operating slowly, could otherwise accumulate too high a radiation dose . The tether would be made to spin in its orbit to keep taut; how to balance the Lorentz torque is discussed. Constraints on heating and bowing are also discussed, comparing conditions for prograde versus retrograde orbits. The system adapts well to the moderate changes in plasma density and motional electric field through the limited radial range in their steep gradients near Jupiter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los sistemas de imagen por ultrasonidos son hoy una herramienta indispensable en aplicaciones de diagnóstico en medicina y son cada vez más utilizados en aplicaciones industriales en el área de ensayos no destructivos. El array es el elemento primario de estos sistemas y su diseño determina las características de los haces que se pueden construir (forma y tamaño del lóbulo principal, de los lóbulos secundarios y de rejilla, etc.), condicionando la calidad de las imágenes que pueden conseguirse. En arrays regulares la distancia máxima entre elementos se establece en media longitud de onda para evitar la formación de artefactos. Al mismo tiempo, la resolución en la imagen de los objetos presentes en la escena aumenta con el tamaño total de la apertura, por lo que una pequeña mejora en la calidad de la imagen se traduce en un aumento significativo del número de elementos del transductor. Esto tiene, entre otras, las siguientes consecuencias: Problemas de fabricación de los arrays por la gran densidad de conexiones (téngase en cuenta que en aplicaciones típicas de imagen médica, el valor de la longitud de onda es de décimas de milímetro) Baja relación señal/ruido y, en consecuencia, bajo rango dinámico de las señales por el reducido tamaño de los elementos. Complejidad de los equipos que deben manejar un elevado número de canales independientes. Por ejemplo, se necesitarían 10.000 elementos separados λ 2 para una apertura cuadrada de 50 λ. Una forma sencilla para resolver estos problemas existen alternativas que reducen el número de elementos activos de un array pleno, sacrificando hasta cierto punto la calidad de imagen, la energía emitida, el rango dinámico, el contraste, etc. Nosotros planteamos una estrategia diferente, y es desarrollar una metodología de optimización capaz de hallar de forma sistemática configuraciones de arrays de ultrasonido adaptados a aplicaciones específicas. Para realizar dicha labor proponemos el uso de los algoritmos evolutivos para buscar y seleccionar en el espacio de configuraciones de arrays aquellas que mejor se adaptan a los requisitos fijados por cada aplicación. En la memoria se trata el problema de la codificación de las configuraciones de arrays para que puedan ser utilizados como individuos de la población sobre la que van a actuar los algoritmos evolutivos. También se aborda la definición de funciones de idoneidad que permitan realizar comparaciones entre dichas configuraciones de acuerdo con los requisitos y restricciones de cada problema de diseño. Finalmente, se propone emplear el algoritmo multiobjetivo NSGA II como herramienta primaria de optimización y, a continuación, utilizar algoritmos mono-objetivo tipo Simulated Annealing para seleccionar y retinar las soluciones proporcionadas por el NSGA II. Muchas de las funciones de idoneidad que definen las características deseadas del array a diseñar se calculan partir de uno o más patrones de radiación generados por cada solución candidata. La obtención de estos patrones con los métodos habituales de simulación de campo acústico en banda ancha requiere tiempos de cálculo muy grandes que pueden hacer inviable el proceso de optimización con algoritmos evolutivos en la práctica. Como solución, se propone un método de cálculo en banda estrecha que reduce en, al menos, un orden de magnitud el tiempo de cálculo necesario Finalmente se presentan una serie de ejemplos, con arrays lineales y bidimensionales, para validar la metodología de diseño propuesta comparando experimentalmente las características reales de los diseños construidos con las predicciones del método de optimización. ABSTRACT Currently, the ultrasound imaging system is one of the powerful tools in medical diagnostic and non-destructive testing for industrial applications. Ultrasonic arrays design determines the beam characteristics (main and secondary lobes, beam pattern, etc...) which assist to enhance the image resolution. The maximum distance between the elements of the array should be the half of the wavelength to avoid the formation of grating lobes. At the same time, the image resolution of the target in the region of interest increases with the aperture size. Consequently, the larger number of elements in arrays assures the better image quality but this improvement contains the following drawbacks: Difficulties in the arrays manufacturing due to the large connection density. Low noise to signal ratio. Complexity of the ultrasonic system to handle large number of channels. The easiest way to resolve these issues is to reduce the number of active elements in full arrays, but on the other hand the image quality, dynamic range, contrast, etc, are compromised by this solutions In this thesis, an optimization methodology able to find ultrasound array configurations adapted for specific applications is presented. The evolutionary algorithms are used to obtain the ideal arrays among the existing configurations. This work addressed problems such as: the codification of ultrasound arrays to be interpreted as individuals in the evolutionary algorithm population and the fitness function and constraints, which will assess the behaviour of individuals. Therefore, it is proposed to use the multi-objective algorithm NSGA-II as a primary optimization tool, and then use the mono-objective Simulated Annealing algorithm to select and refine the solutions provided by the NSGA I I . The acoustic field is calculated many times for each individual and in every generation for every fitness functions. An acoustic narrow band field simulator, where the number of operations is reduced, this ensures a quick calculation of the acoustic field to reduce the expensive computing time required by these functions we have employed. Finally a set of examples are presented in order to validate our proposed design methodology, using linear and bidimensional arrays where the actual characteristics of the design are compared with the predictions of the optimization methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La construcción en la actualidad de nuevas fuentes para el uso de haces de neutrones así como los programas de renovación en curso en algunas de las instalaciones experimentales existentes han evidenciado la necesidad urgente de desarrollar la tecnología empleada para la construcción de guías de neutrones con objeto de hacerlas mas eficientes y duraderas. Esto viene motivado por el hecho de que varias instalaciones de experimentación con haces de neutrones han reportado un número de incidentes mecánicos con tales guías, lo que hace urgente el progresar en nuestro conocimiento de los susbtratos vítreos sobre los cuales se depositan los espejos que permiten la reflexión total de los neutrones y como aquellos se degradan con la radiación. La presente tesis se inscribe en un acuerdo de colaboración establecido entre el Institut Max von Laue - Paul Langevin (ILL) de Grenoble y el Consorcio ESS-Bilbao con objeto de mejorar el rendimiento y sostenibilidad de los sistemas futuros de guiado de neutrones. El caso de la Fuente Europea de Espalación en construcción en Lund sirve como ejemplo ya que se contempla la instalación de guías de neutrones de más de 100 metros en algunos de los instrumentos. Por otro lado, instalaciones como el ILL prevén también dentro del programa Endurance de rejuvenecimiento la reconstrucción de varias líneas de transporte de haz. Para el presente estudio se seleccionaron cuatro tipos de vidrios borosilicatados que fueron el Borofloat, N-ZK7, N-BK7 y SBSL7. Los tres primeros son bien conocidos por los especialistas en instrumentación neutrónica ya que se han empleado en la construcción de varias instalaciones mientras que el último es un candidato potencial en la fabricación de substratos para espejos neutrónicos en un futuro. Los cuatro vidrios tiene un contenido en óxido de Boro muy similar, approximadamente un 10 mol.%. Tal hecho que obedece a las regulaciones para la fabricación de estos dispositivos hace que tales substratos operen como protección radiológica absorbiendo los neutrones transmitidos a través del espejo de neutrones. Como contrapartida a tal beneficio, la reacción de captura 10B(n,_)7Li puede degradar el substrato vítreo debido a los 2.5 MeV de energía cinética depositados por la partícula _ y los núcleos en retroceso y de hecho la fragilidad de tales vidrios bajo radiación ha sido atribuida desde hace ya tiempo a los efectos de esta reacción. La metodología empleada en esta tesis se ha centrado en el estudio de la estructura de estos vidrios borosilicatados y como esta se comporta bajo condiciones de radiación. Los materiales en cuestión presentan estructuras que dependen de su composición química y en particular del ratio entre formadores y modificadores de la red iono-covalente. Para ello se han empleado un conjunto de técnicas de caracterización tanto macro- como microscópicas tales como estudios de dureza, TEM, Raman, SANS etc. que se han empleado también para determinar el comportamiento de estos materiales bajo radiación. En particular, algunas propiedades macroscópicas relacionadas con la resistencia de estos vidrios como elementos estructurales de las guías de neutrones han sido estudiadas así como también los cambios en la estructura vítrea consecuencia de la radiación. Para este propósito se ha diseñado y fabricado por el ILL un aparato para irradiación de muestras con neutrones térmicos en el reactor del ILL que permite controlar la temperatura alcanzada por la muestra a menos de 100 °C. Tal equipo en comparación con otros ya existences permite en cuestión de dias acumular las dosis recibidas por una guía en operación a lo largo de varios años. El uso conjunto de varias técnicas de caracterización ha llevado a revelar que los vidrios aqui estudiados son significativamente diferentes en cuanto a su estructura y que tales diferencias afectan a sus propiedades macroscópicas asi como a su comportamiento bajo radiación. Tal resultado ha sido sorprendente ya que, como se ha mencionado antes, algunos de estos vidrios eran bien conocidos por los fabricantes de guías de neutrones y hasta el momento eran considerados prácticamente similares debido a su contenido comparable en óxido de Boro. Sin embargo, los materiales N-BK7 and S-BSL7 muetran gran homogeneidad a todas las escalas de longitud, y más específicamente, a escalas nanométricas las subredes de Sílice y óxido de Boro se mezclan dando logar a estructuras locales que recuerdan a la del cristal de Reedmergnerita. Por el contrario, N-ZK7 y Borofloat muestran dominios separados ricos en Sílice o Boro. Como era de esperar, las importantes diferencias arriba mencionadas se traducen en comportamientos dispares de estos materiales bajo un haz de neutrones térmicos. Los resultados muestran que el N-BK7 y el S-BSL7 son los más estables bajo radiación, lo que macroscópicamente hace que estos materiales muestren un comportamiento similar expandiéndose lentamente en función de la dosis recibida. Por el contario, los otros dos materiales muestran un comportamiento mucho más reactivo, que hace que inicialmente se compacten con la dosis recibida lo que hace que las redes de Silicio y Boro se mezclen resultando en un incremento en densidad hasta alcanzar un valor límite, seguido por un proceso de expansión lenta que resulta comparable al observado para N-BK7 y SBSL7. Estos resultados nos han permitido explicar el origen de las notorias diferencias observadas en cuanto a las dosis límite a partir de las cuales estos materiales desarrollan procesos de fragmentación en superficie. ABSTRACT The building of new experimental neutron beam facilities as well as the renewal programmes under development at some of the already existing installations have pinpointed the urgent need to develop the neutron guide technology in order to make such neutron transport devices more efficient and durable. In fact, a number of mechanical failures of neutron guides have been reported by several research centres. It is therefore important to understand the behaviour of the glass substrates on top of which the neutron optics mirrors are deposited and how these materials degrade under radiation conditions. The case of the European Spallation Source (ESS) at present under construction at Lund is a good example. It previews the deployment of neutron guides having more than 100 metres of length for most of the instruments. Also, the future renovation programme of the ILL, called Endurance, foresees the refurbishment of several beam lines. This Ph.D. thesis was the result of a collaboration agreement between the ILL and ESS-Bilbao aiming to improve the performance and sustainability of future neutron delivery systems. Four different industrially produced alkali-borosilicate glasses were selected for this study: Borofloat, N-ZK7, N-BK7 and SBSL7. The first three are well known within the neutron instrumentation community as they have already been used in several installations whereas the last one is at present considered as a candidate for making future mirror substrates. All four glasses have a comparable content of boron oxide of about 10 mol.%. The presence of such a strong neutron absorption element is in fact a mandatory component for the manufacturing of neutron guides because it provides a radiological shielding for the environment. This benefit is however somewhat counterbalanced since the resulting 10B(n,_)7Li reactions degrade the glass due to the deposited energy of 2.5 MeV by the _ particle and the recoil nuclei. In fact, the brittleness of some of these materials has been ascribed to this reaction. The methodology employed by this study consisted in understanding the general structure of borosilicates and how they behave under irradiation. Such materials have a microscopic structure strongly dependent upon their chemical content and particularly on the ratios between network formers and modifiers. The materials have been characterized by a suite of macroscopic and structural techniques such as hardness, TEM, Raman, SANS, etc. and their behaviour under irradiation was analysed. Some macroscopic properties related to their resistance when used as guide structural elements were monitored. Also, changes in the vitreous structure due to radiation were observed by means of several experimental tools. For such a purpose, an irradiation apparatus has been designed and manufactured to enable irradiation with thermal neutrons within the ILL reactor while keeping the samples below 100 °C. The main advantage of this equipment if compared to others previously available was that it allowed to reach in just some days an equivalent neutron dose to that accumulated by guides after several years of use. The concurrent use of complementary characterization techniques lead to the discovery that the studied glasses were deeply different in terms of their glass network. This had a strong impact on their macroscopic properties and their behaviour under irradiation. This result was a surprise since, as stated above, some of these materials were well known by the neutron guide manufacturers, and were considered to be almost equivalent because of their similar boron oxide content. The N-BK7 and S-BSL7 materials appear to be fairly homogeneous glasses at different length scales. More specifically, at nanometre scales, silicon and boron oxide units seem to mix and generate larger structures somewhat resembling crystalline Reedmergnerite. In contrast, N-ZK7 and Borofloat are characterized by either silicon or boron rich domains. As one could expect, these drastic differences lead to their behaviour under thermal neutron flux. The results show that N-BK7 and S-BSL7 are structurally the most stable under radiation. Macroscopically, such stability results in the fact that these two materials show very slow swelling as a function or radiation dose. In contrast, the two other glasses are much more reactive. The whole glass structure compacts upon radiation. Specifically, the silica network, and the boron units tend to blend leading to an increase in density up to some saturation, followed by a very slow expansion which comes to be of the same order than that shown by N-BK7 and S-BSL7. Such findings allowed us to explain the drastic differences in the radiation limits for macroscopic surface splintering for these materials when they are used in neutron guides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viável

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Medidas de espectroscopia gama de alta resolução têm diversas aplicações. Aplicações envolvendo medidas de radioisótopos de meia-vida curta podem apresentar problemas de baixa precisão nas contagens quando a fonte radioativa está distante do detector e de perda de acurácia por efeitos de tempo morto e empilhamento de pulsos em situação de altas taxas de contagens. Um modo de minimizar esses problemas é alterando a posição da fonte radioativa durante o processo de medição, aproximando-a do detector conforme sua atividade diminui e assim maximizando o número de contagens medidas. Neste trabalho, foi desenvolvido o Movimentador de Amostras Radioativas Automatizado (MARA), um aparato de baixo custo, feito com materiais de baixo número atômico e leve, projetado e construído para auxiliar nas medidas de espectroscopia gama, capaz de controlar a distância entre a fonte e o detector, permitindo inclusive que ocorra alteração dessa distância durante o processo de medição. Por ser automatizado ele otimiza o tempo do operador, que tem total liberdade para criar suas rotinas de medidas no dispositivo, além de evitar que o mesmo tome uma parcela da dose radioativa. Foi também feita uma interface que permite controle do MARA e a programação do sistema de aquisição de dados. Foram realizados testes para otimização da operação do sistema MARA e foi verificada a segurança de operação do MARA, não apresentando nenhuma falha durante seus testes. Foi aplicado o teste de repetitividade, por meio de medições com uma fonte calibrada de 60Co, e verificou-se que o sistema de movimentação de prateleiras automatizado reproduziu os resultados do sistema estático com confiabilidade de 95%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Póster presentado en el VII European/ I World Meeting in Visual and Physiological Optics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are a large number of image processing applications that work with different performance requirements and available resources. Recent advances in image compression focus on reducing image size and processing time, but offer no real-time solutions for providing time/quality flexibility of the resulting image, such as using them to transmit the image contents of web pages. In this paper we propose a method for encoding still images based on the JPEG standard that allows the compression/decompression time cost and image quality to be adjusted to the needs of each application and to the bandwidth conditions of the network. The real-time control is based on a collection of adjustable parameters relating both to aspects of implementation and to the hardware with which the algorithm is processed. The proposed encoding system is evaluated in terms of compression ratio, processing delay and quality of the compressed image when compared with the standard method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical power of a thick spherical lens and its Coddington shape factor are essential magnitudes that characterize its image quality. Here, we propose an experimental procedure and apparatus that allow accurate determination of those magnitudes for any spherical lens from geometrical measurements. The performance of the technique and the used instruments are simple since it only requires a microscope and an optical mouse. The propose overcomes the drawbacks of other devices that need of the refractive index or may damage the lens surfaces, like spherometers, and provides similar results to those from commercial lensmeters.