970 resultados para Biomedical engineering|Biomechanics|Biophysics
Resumo:
In this paper, a novel motion-tracking scheme using scale-invariant features is proposed for automatic cell motility analysis in gray-scale microscopic videos, particularly for the live-cell tracking in low-contrast differential interference contrast (DIC) microscopy. In the proposed approach, scale-invariant feature transform (SIFT) points around live cells in the microscopic image are detected, and a structure locality preservation (SLP) scheme using Laplacian Eigenmap is proposed to track the SIFT feature points along successive frames of low-contrast DIC videos. Experiments on low-contrast DIC microscopic videos of various live-cell lines shows that in comparison with principal component analysis (PCA) based SIFT tracking, the proposed Laplacian-SIFT can significantly reduce the error rate of SIFT feature tracking. With this enhancement, further experimental results demonstrate that the proposed scheme is a robust and accurate approach to tackling the challenge of live-cell tracking in DIC microscopy.
Resumo:
A new method for catalyst deposition on the inner walls of capillary microreactors is proposed which allows exact control of the coating thickness, pore size of the support, metal particle size, and metal loading. The wall-coated microreactors have been tested in a selective hydrogenation reaction. Activity and selectivity reach values close to those obtained with a homogeneous Pd catalyst. The catalyst activity was stable for a period of 1000 h time-on-stream.
Resumo:
Research has focused on in vitro expansion of bone marrow stromal cells with the aim of developing cell-based therapies or tissue-engineered constructs. There is debate over whether there is a reduction in stem cells/osteoprogenitors in the bone marrow compartment with increasing age. The aim of this study was to investigate patient factors that affect the progenitor pool in bone marrow samples. Six milliliters of marrow aspirate was obtained from the femoral canal of 38 primary hip replacement patients (aged 28-91). Outcome measures were total nucleated cell count, colony-forming efficiency, alkaline phosphatase expression, and expression of stem cell markers. There was a nonsignificant negative correlation between age and both colony-forming efficiency and stem cell marker expression. However, body mass index showed a positive, significant correlation with colony area and number in men-accounting for up to 75% of the variation. In conclusion, body mass index, not age, was highly predictive of the number of progenitors found in bone marrow, and this relationship was sex specific. These results may inform the clinician's treatment choice when considering bone marrow-based therapies. Further, it highlights the need to widen research into patient factors that affect the adult stem cell population beyond age and reinforces the need to consider sexes separately.
Resumo:
Experimental use of statins as stimulators of bone formation suggests they may have widespread applicability in the field of orthopaedics. With their combined effects on osteoblasts and osteoclasts, statins have the potential to enhance resorption of synthetic materials and improve bone ingrowth. In this study, the effect of oral and local administration of simvastatin to a 0 tricalcium phosphate (beta TCP)-filled defect around an implant was compared with recombinant human bone morphogenetic protein 2 (rhBMP2). On hundred and sixty-two Sprague-Dawley rats were assigned to treatment groups: local application of 0.1, 0.9 or 1.7 mg of simvastatin, oral simvastatin at 5, 10 or 50 mg kg(-1) day(-1) for 20 days, local delivery of I or 10 mu g of rhBMP2, or control. At 6 weeks rhBMP2 increased serum tartrate-resistant acid phosphatase 5b levels and reduced PTCP area fraction, particle size and number compared with control, suggesting increased osteoclast activity. There was reduced stiffness and increased mechanical strength with this treatment. Local simvastatin resulted in a decreased mineral apposition rate at 6 weeks and increased fibrous area fraction, PTCP area fraction, particle size and number at 26 weeks. Oral simvastatin had no effect compared with control. Local application of rhBMP2 increased resorption and improved mechanical strength whereas simvastatin was detrimental to healing. Oral simvastatin was ineffective at promoting either ceramic resorption or bone formation. The effect of statins on the repair of bone defects with graft substitute materials is influenced by its bioavailability. Thus, further studies on the optimal delivery system are needed. (C) 2007 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to visualize integrin expression by cells in interface tissue in relation to their ligands. Tissue samples were obtained from 25 patients undergoing revision of aseptically loose total joint replacements. Serial sections were immunolabeled for the integrins alpha (2)beta (1) alpha (v)beta (3), alpha (4)beta (1) alpha (L)beta (2) (CD11a), alpha (M)beta (2) (CD11b), and alpha (x)beta (2) (CD11c), and the ligands fibronectin, laminin, vitronectin, intercellular adhesion molecule-1, and vascular adhesion molecule-1. Most cells were found to express alpha (2)beta (1) most macrophages and giant cells expressed CD11b, and the majority of CD11a was found on perivascular T lymphocytes. From the small amount of alpha (4)beta (1) and vascular adhesion molecule-1 expression in the interface tissue and the combination of CD11a, CD11b, and intercellular adhesion molecule-1 expression, it would seem that macrophages use beta (2) integrins to transmigrate. (C) 2001 John Wiley & Sons, Inc.
Resumo:
Over twenty years ago ‘Our Common Future’ presented a conceptualization and explanation of the concept of sustainable development. Since then numerous alternative definitions of the concept have been offered, of which at least some are exclusive to each other. At the same time, the role of business in the transition to sustainable development has increasingly received attention. Bringing these two trends in sustainable development together, this paper returns to the Brundtland version of the concept to examine to what extent the original principles of sustainable development are still embedded within key business guidelines, namely the UN Global Compact, the OECD Guidelines for Multinational Enterprises, the ICC Business Charter for Sustainable Development, the CAUX Principles, the Global Sullivan Principles and the CERES Principles. The findings suggest that these business guidelines tend to emphasize environmental rather than social aspects of sustainable development, in particular to the detriment of the original Brundtland prioritization of the needs of the poorest. Furthermore, the attention to environmental aspects stresses win-win situations and has a clear managerialist focus; whereas more conceptual environmental issues concerning systems interdependencies, critical thresholds or systemic limits to growth find little attention. The normative codes and principles targeted at the private sector thus not only add another voice to the multiple discourses on sustainable development but also contribute to a reinterpretation of the original agenda set by Brundtland towards conceptualizations of sustainable development around the needs of industrialised rather than developing countries. Copyright © 2011 John Wiley & Sons, Ltd and ERP Environment
Resumo:
All-optical signal processing enables modulation and transmission speeds not achievable using electronics alone(1,2). However, its practical applications are limited by the inherently weak nonlinear effects that govern photon-photon interactions in conventional materials, particularly at high switching rates(3). Here, we show that the recently discovered nonlocal optical behaviour of plasmonic nanorod metamaterials(4) enables an enhanced, ultrafast, nonlinear optical response. We observe a large (80%) change of transmission through a subwavelength thick slab of metamaterial subjected to a low control light fluence of 7 mJ cm(-2), with switching frequencies in the terahertz range. We show that both the response time and the nonlinearity can be engineered by appropriate design of the metamaterial nanostructure. The use of nonlocality to enhance the nonlinear optical response of metamaterials, demonstrated here in plasmonic nanorod composites, could lead to ultrafast, low-power all-optical information processing in subwavelength-scale devices.
Resumo:
The synthesis of nanophase hydroxyapatite (nHA) is of importance in the field of biomaterials and bone tissue engineering. The bioactive and osteoconductive properties of nHA are of much benefit to a wide range of biomedical applications such as producing bone tissue engineered constructs, coating medical implants, or as a carrier for plasmid DNA in gene delivery. This study aimed to develop a novel low-temperature dispersant-aided precipitation reaction to produce nHA particles (
Resumo:
The objectives of this study were to develop a three-dimensional acellular cartilage matrix (ACM) and investigate its possibility for use as a scaffold in cartilage tissue engineering. Bovine articular cartilage was decellularized sequentially with trypsin, nuclease solution, hypotonic buffer, and Triton x 100 solution; molded with freeze-drying process; and cross-linked by ultraviolet irradiation. Histological and biochemical analysis showed that the ACM was devoid of cells and still maintained the collagen and glycosaminoglycan components of cartilage. Scanning electronic microscopy and mercury intrusion porosimetry showed that the ACM had a sponge-like structure of high porosity. The ACM scaffold had good biocompatibility with cultured rabbit bone marrow mesenchymal stem cells with no indication of cytotoxicity both in contact and in extraction assays. The cartilage defects repair in rabbit knees with the mesenchymal stem cell-ACM constructs had a significant improvement of histological scores when compared to the control groups at 6 and 12 weeks. In summary, the ACM possessed the characteristics that afford it as a potential scaffold for cartilage tissue engineering.
Resumo:
Computational modelling is becoming ever more important for obtaining regulatory approval for new medical devices. An accepted approach is to infer performance in a population from an analysis conducted for an idealised or ‘average’ patient; we present here a method for predicting the performance of an orthopaedic implant when released into a population—effectively simulating a clinical trial. Specifically we hypothesise that an analysis based on a method for predicting the performance in a population will lead to different conclusions than an analysis based on an idealised or ‘average’ patient. To test this hypothesis we use a finite element model of an intramedullary implant in a bone whose size and remodelling activity is different for each individual in the population. We compare the performance of a low Young’s modulus implant (View the MathML source) to one with a higher Young’s modulus (200 GPa). Cyclic loading is applied and failure is assumed when the migration of the implant relative to the bone exceeds a threshold magnitude. The analysis for an idealised of ‘average’ patient predicts that the lower modulus device survives longer whereas the analysis simulating a clinical trial predicts no statistically-significant tendency (p=0.77) for the low modulus device to perform better. It is concluded that population-based simulations of implant performance–simulating a clinical trial–present a very valuable opportunity for more realistic computational pre-clinical testing of medical devices.