981 resultados para Benachteiligtes Kind


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A. lumbricoides has been associated to the ABO System by various authors. The objective was to detect ABO System epitopes in A. lumbricoides of groups O, A, B and AB patients. 28 adult parasites were obtained from children to be used as assay material. The patients ABO blood groups were determined. Extracts of A. lumbricoides [AE] were prepared by surgical remotion of the cuticle and refrigerated mechanical rupture. Agglutination Inhibition (AI) and Hemoagglutination Kinetics (HK) tests were used with the [AE]. Of the 28 [AE], eight belonged to O group patients, 15 to A group, three to B group and the remaining two to AB children. The AI Test showed A epitopes in two [AE] of group A patients and B epitopes in two [AE] of group B patients. The HK Test showed B antigenic determiners in two [AE] of group B patients and in two [AE] of group AB patients as well as A antigenic determiners in one [AE] of A group patient. Of the 28 [AE] studied in both tests B epitopes were detected in all [AE] from B and AB patients and A epitopes in three of the 15 [AE] of group A patients. The experiments carried out suggest that A. lumbricoides might absorb A and B antigens from the host, and/or modify the cuticular carbohydrates expression as a kind of antigenic mimicry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes different kind of solid-contact graphite-based electrodes for the selective determination of sulphonamides (SPHs) in pharmaceuticals, biological fluids and aquaculture waters. Sulfadiazine (SDZ) and sulfamethoxazole (SMX) were selected for this purpose for being the most representative compounds of this group. The template molecules were imprinted in sol–gel (ISG) and the resulting material was used as detecting element. This was made by employing it as either a sensing layer or an ionophore of PVC-based membranes and subsequent potentiometric transduction, a strategy never reported before. The corresponding non-imprinted sol–gel (NISG) membranes were used as blank. The effect of plasticizer and kind/charge of ionic lipophilic additive was also studied. The best performance in terms of slope, linearity ranges and signal reproducibility and repeatability was achieved by PVC membranes including a high dielectric constant plasticizer and 15 mg of ISG particles. The corresponding average slope was −51.4 and −52.4 mV/decade, linear responses were 9.0 × 10−6 and 1.7 × 10−5 M, and limits of detection were 0.74 and 1.3 μg/mL for SDZ and for SMX, respectively. Good selectivity with log Kpot < −0.3 was observed for carbonate, chloride, fluoride, hydrogenocarbonate, nitrate, nitrite, phosphate, cyanide, sulfate, borate, persulphate, citrate, tartrate, salicylate, tetracycline, ciprofloxacin, sulphamerazine, sulphatiazole, dopamine, glucose, galactose, cysteine and creatinine. The best sensors were successfully applied to the analysis of real samples with relative errors ranging from −6.8 to + 3.7%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - Este trabalho consiste numa análise sobre a viabilidade económico-financeira do projecto de construção de uma Unidade de Cuidados Continuados Integrados de Longa Duração e Manutenção pela Fundação COI, que pretende ser uma resposta adequada à diversidade de fenómenos que têm origem no envelhecimento populacional, inserindo-se no modelo de prestação de cuidados de saúde e apoio social preconizado pela Rede Nacional de Cuidados Continuados Integrados. Em termos estruturais, numa primeira fase, o trabalho faz uma análise sobre o estado da arte dos cuidados continuado, nomeadamente através da sua conceptualização e enquadramento, focando os aspectos e características da RNCCI, nomeadamente os aspectos relacionados com a sustentabilidade financeira e os desafios futuros que este sector da saúde se confronta. Numa segunda fase, o trabalho apresenta o projecto de investimento alvo do estudo de caso, mediante o enquadramento histórico e caracterização da Fundação COI, sendo descrita especificamente a tipologia de longa duração e manutenção e o projecto em termos da sua estrutura física e humana. Numa terceira fase, o trabalho estuda a racionalidade do projecto de investimento, através da análise económico-financeira. Tendo-se concluído, com a utilização de indicadores de avaliação e decisão de investimentos, que a ULDM, é viável. Deve-se contudo ter em conta que a sua viabilidade é sensível a hipotéticas alterações de cenários, nomeadamente perante diferentes taxas de ocupação ou alteração do modelo de pagamento. ----------------------- ABSTRACT - This paper consists on analyzing the economical and financial viability of a project of Integrated Continuous Cares on Long-Term and Maintenance Unit (LTMU), managed by COI Foundation, that can create a correct social answer on the various aspects and phenomenon’s that have their origin in an aged population. This kind of project belongs in the role model of social and health cares of the National Network of Integrated Continuous Cares (NNICC). In a first stage the paper is focused on the analysis of the state of the present services of the continuous cares in Portugal, more concretely of his conceptualization and social frame, putting under the lights the aspects and characteristics of the NNICC, more closely the parts related to their financial sustainability and the challenges that this health sector faces nowadays. The next stage is about the investment project applied to this case-study, given his social and historical frame and attending to the specific characteristics of the COI Foundation. It’s also describing its specific LTMU typology under the involved physic and human structure. Finally this paper study the investment project rationality trough scientific methods like its economic–financial analysis. The conclusion, using decision and evaluation procedures that lead to financial indicators, is that the LTMU, is viable. However, the viability of the project is sensible to an hypothetical change of scenario, namely with different rates of change of occupation or type of payment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A theory of free vibrations of discrete fractional order (FO) systems with a finite number of degrees of freedom (dof) is developed. A FO system with a finite number of dof is defined by means of three matrices: mass inertia, system rigidity and FO elements. By adopting a matrix formulation, a mathematical description of FO discrete system free vibrations is determined in the form of coupled fractional order differential equations (FODE). The corresponding solutions in analytical form, for the special case of the matrix of FO properties elements, are determined and expressed as a polynomial series along time. For the eigen characteristic numbers, the system eigen main coordinates and the independent eigen FO modes are determined. A generalized function of visoelastic creep FO dissipation of energy and generalized forces of system with no ideal visoelastic creep FO dissipation of energy for generalized coordinates are formulated. Extended Lagrange FODE of second kind, for FO system dynamics, are also introduced. Two examples of FO chain systems are analyzed and the corresponding eigen characteristic numbers determined. It is shown that the oscillatory phenomena of a FO mechanical chain have analogies to electrical FO circuits. A FO electrical resistor is introduced and its constitutive voltage–current is formulated. Also a function of thermal energy FO dissipation of a FO electrical relation is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary sarcoma of the heart is a rare disease that has an ominous prognosis with either medical or surgical therapy. We report a case of a 25-year-old woman with sarcoma of the heart who received a transplant and is clinically well after 7 years. We believe that transplantation must be considered in this kind of pathology for selected cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Well-structured questionnaire on the perception, impression and response to genitourinary bilharziasis (Genitourinary schistosomiasis) was administered and explained in local languages: 'Igbo' 'Esan' 'Ezon' Itshekiri and Bini to 33815 inhabitants of selected endemic areas in south-eastern Nigeria from January, 1999 to December, 2001. Out of this number, 3815 (11.3%) were properly filled and returned. About 42.0% of the inhabitants admitted knowledge of the disease, while 14 (0.4%) knew about the aetiologic agent. About 181 (5.0%) who responded, admitted procuring treatment, while 100 (5.0%) declined to seek treatment of any sort. The relationships between water-bodies and human activities, and infection were well discussed. Amongst those who admitted knowledge of the disease but no knowledge of its etiologic agent, declined seeking treatment of any kind, but believe the disease is a natural phenomenon in ones developmental stage and therefore of no morbidity and mortality. Laboratory analysis of urine, faeces, semen and HVS was employed to assess questionnaire responses, and in some cases, physical examination was utilized to augment laboratory analysis in confirming urinal diagnosis. Haematuria was only directly related to egg count in the early part of life. Females were significantly haematuric and excreted more ova than males (p < 0.05). Headache (43.0%) and fever (31.0%) were major clinical signs while sexual pains (22.0%) were the least.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Thesis submitted for the co-tutelle degree of Doctor in Physics at Universidade Nova de Lisboa and Université Pierre et Marie Curie

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to analyze the enteroparasitic occurrence in children from 0 to 12 years old consulted at the University of western São Paulo Clinical Laboratory, Presidente Prudente, SP, Brazil, in relation to the socioeconomic profile of the attended children. Stool samples were examined and a questionnaire was applied with the objective of knowing the patient's age, sex, medical attendance, characteristic of the habitation, provisioning of water, dejection and domestic waste fates, use of footwear and clinical signs. The software EPI INFO 6 (Version 6.04b) was used for the elaboration of the data bank structure and analysis after previous data codification. Among 1,000 children analyzed, as many as 21.3% presented some kind of parasite. The most frequent protozoan was Giardia lamblia (7.3%) followed by Entamoeba coli (3.9%). The most frequent helminth was Enterobius vermicularis (1.9%) followed by Hymenolepis nana (0.5%). The most frequent protozoan association was Giardia lamblia / Entamoeba coli (0.9%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, we evaluate electrocardiographic (ECG) alterations among urban workers from a mechanical-metallurgical industry in São Paulo, Brazil. In a cross-sectional survey carried out in 1980, we found 2.2% positive serological testing for Trypanosoma cruzi infection among 27,081 workers. A comparison between seropositive workers and a random sample of seronegative workers frequency-matched by age and occupation revealed that seropositive workers had a much lower educational level, and that a higher proportion of seropositive workers had ECG abnormalities (42.7%) when compared to those negative for T. cruzi infection (19.8%). The high frequency of ECG abnormalities suggests the need to provide medical assistance to these workers, without any kind of discrimination and to bring in a form of management that would decrease this dangerous risk to the workers and people around them.