987 resultados para BYPASS GRAFTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enhanced tobacco control policies and programmes are an important component of any strategic approach to improving population health and tackling health inequalities. The consultation on standardised packaging of tobacco products in the UK is particularly timely in view of the recent publication of the Ten Year Tobacco Strategy for Northern Ireland (DHSSPS, 2012). In this strategy the Department expressed its support for the introduction of further measures to reduce the influence of tobacco advertising and promotion upon children e.g. the introduction of plain packaging for cigarettes and hand rolling tobacco.  IPH key points •    The extent of tobacco-related harm across the island of Ireland and across the UK is unacceptable. Increasingly comprehensive and effective tobacco-control interventions are required. •    IPH recommends the adoption of option 2: require standardised packaging of tobacco products. •    IPH acknowledges that as plain packaging has not yet been introduced in any country, it is not possible at this time to accurately forecast the extent and nature of this intervention on population level health outcomes in the UK context. •    The proposed approach appears comprehensive in addressing the direct and indirect ways in which elements of tobacco packaging can promote brand appeal and can portray impressions in respect of tobacco-related harm. Consideration should be given to include specific provisions relating to roll-your-own (RYO) tobacco packaging. Any approach needs to be regularly reviewed to take into account attempts to bypass restrictions and evaluate responses in respect of consumer choices. •    IPH considers that the introduction of plain packaging has the potential to support the achievement of the goals set out in the Ten Year Tobacco Control Strategy for Northern Ireland ( DHSSPS, 2012). •    Among children in Northern Ireland who reported trying their first cigarette, around one quarter were aged 11 or under and three quarters were 14 or under when they did so (DHSSPS, 2012).  The very young age of these children is concerning on many levels including their susceptibility to sophisticated branding and marketing techniques linked to tobacco packaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thesis at hand is concerned with the spatio-temporal brain mechanisms of visual food perception as investigated by electrical neuroimaging. Due to the increasing prevalence of obesity and its associated challenges for public health care, there is a need to better understand behavioral and brain processes underlying food perception and food-based decision-making. The first study (Study A) of this thesis was concerned with the role of repeated exposure to visual food cues. In our everyday lives we constantly and repeatedly encounter food and these exposures influence our food choices and preferences. In Study A, we therefore applied electrical neuroimaging analyses of visual evoked potentials to investigate the spatio-temporal brain dynamics linked to the repeated viewing of high- and low-energy food cues (published manuscript: "The role of energetic value in dynamic brain response adaptation during repeated food image viewing" (Lietti et al., 2012)). In this study, we found that repetitions differentially affect behavioral and brain mechanisms when high-energy, as opposed to low-energy foods and non-food control objects, were viewed. The representation of high-energy food remained invariant between initial and repeated exposures indicating that the sight of high-energy dense food induces less behavioral and neural adaptation than the sight of low-energy food and non-food control objects. We discuss this finding in the context of the higher salience (due to greater motivation and higher reward or hedonic valuation) of energy- dense food that likely generates a more mnemonically stable representation. In turn, this more invariant representation of energy-dense food is supposed to (partially) explain why these foods are over-consumed despite of detrimental health consequences. In Study Β we investigated food responsiveness in patients who had undergone Roux-en-Y gastric bypass surgery to overcome excessive obesity. This type of gastric bypass surgery is not only known to alter food appreciation, but also the secretion patterns of adipokines and gut peptides. Study Β aimed at a comprehensive and interdisciplinary investigation of differences along the gut-brain axis in bypass-operated patients as opposed to weight-matched non-operated controls. On the one hand, the spatio-temporal brain dynamics to the visual perception of high- vs. low-energy foods under differing states of motivation towards food intake (i.e. pre- and post-prandial) were assessed and compared between groups. On the other hand, peripheral gut hormone measures were taken in pre- and post-prandial nutrition state and compared between groups. In order to evaluate alterations in the responsiveness along the gut-brain-axis related to gastric bypass surgery, correlations between both measures were compared between both participant groups. The results revealed that Roux-en- Y gastric bypass surgery alters the spatio-temporal brain dynamics to the perception of high- and low-energy food cues, as well as the responsiveness along the gut-brain-axis. The potential role of these response alterations is discussed in relation to previously observed changes in physiological factors and food intake behavior post-Roux-en-Y gastric bypass surgery. By doing so, we highlight potential behavioral, neural and endocrine (i.e. gut hormone) targets for the future development of intervention strategies for deviant eating behavior and obesity. Together, the studies showed that the visual representation of foods in the brain is plastic and that modulations in neural activity are already noted at early stages of visual processing. Different factors of influence such as a repeated exposure, Roux-en-Y gastric bypass surgery, motivation (nutrition state), as well as the energy density of the visually perceived food were identified. En raison de la prévalence croissante de l'obésité et du défi que cela représente en matière de santé publique, une meilleure compréhension des processus comportementaux et cérébraux liés à la nourriture sont nécessaires. En particulier, cette thèse se concentre sur l'investigation des mécanismes cérébraux spatio-temporels liés à la perception visuelle de la nourriture. Nous sommes quotidiennement et répétitivement exposés à des images de nourriture. Ces expositions répétées influencent nos choix, ainsi que nos préférences alimentaires. La première étude (Study A) de cette thèse investigue donc l'impact de ces exposition répétée à des stimuli visuels de nourriture. En particulier, nous avons comparé la dynamique spatio-temporelle de l'activité cérébrale induite par une exposition répétée à des images de nourriture de haute densité et de basse densité énergétique. (Manuscrit publié: "The role of energetic value in dynamic brain response adaptation during repeated food image viewing" (Lietti et al., 2012)). Dans cette étude, nous avons pu constater qu'une exposition répétée à des images représentant de la nourriture de haute densité énergétique, par opposition à de la nourriture de basse densité énergétique, affecte les mécanismes comportementaux et cérébraux de manière différente. En particulier, la représentation neurale des images de nourriture de haute densité énergétique est similaire lors de l'exposition initiale que lors de l'exposition répétée. Ceci indique que la perception d'images de nourriture de haute densité énergétique induit des adaptations comportementales et neurales de moindre ampleur par rapport à la perception d'images de nourriture de basse densité énergétique ou à la perception d'une « catégorie contrôle » d'objets qui ne sont pas de la nourriture. Notre discussion est orientée sur les notions prépondérantes de récompense et de motivation qui sont associées à la nourriture de haute densité énergétique. Nous suggérons que la nourriture de haute densité énergétique génère une représentation mémorielle plus stable et que ce mécanisme pourrait (partiellement) être sous-jacent au fait que la nourriture de haute densité énergétique soit préférentiellement consommée. Dans la deuxième étude (Study Β) menée au cours de cette thèse, nous nous sommes intéressés aux mécanismes de perception de la nourriture chez des patients ayant subi un bypass gastrique Roux- en-Y, afin de réussir à perdre du poids et améliorer leur santé. Ce type de chirurgie est connu pour altérer la perception de la nourriture et le comportement alimentaire, mais également la sécrétion d'adipokines et de peptides gastriques. Dans une approche interdisciplinaire et globale, cette deuxième étude investigue donc les différences entre les patients opérés et des individus « contrôles » de poids similaire au niveau des interactions entre leur activité cérébrale et les mesures de leurs hormones gastriques. D'un côté, nous avons investigué la dynamique spatio-temporelle cérébrale de la perception visuelle de nourriture de haute et de basse densité énergétique dans deux états physiologiques différent (pre- et post-prandial). Et de l'autre, nous avons également investigué les mesures physiologiques des hormones gastriques. Ensuite, afin d'évaluer les altérations liées à l'intervention chirurgicale au niveau des interactions entre la réponse cérébrale et la sécrétion d'hormone, des corrélations entre ces deux mesures ont été comparées entre les deux groupes. Les résultats révèlent que l'intervention chirurgicale du bypass gastrique Roux-en-Y altère la dynamique spatio-temporelle de la perception visuelle de la nourriture de haute et de basse densité énergétique, ainsi que les interactions entre cette dernière et les mesures périphériques des hormones gastriques. Nous discutons le rôle potentiel de ces altérations en relation avec les modulations des facteurs physiologiques et les changements du comportement alimentaire préalablement déjà démontrés. De cette manière, nous identifions des cibles potentielles pour le développement de stratégies d'intervention future, au niveau comportemental, cérébral et endocrinien (hormones gastriques) en ce qui concerne les déviances du comportement alimentaire, dont l'obésité. Nos deux études réunies démontrent que la représentation visuelle de la nourriture dans le cerveau est plastique et que des modulations de l'activité neurale apparaissent déjà à un stade très précoce des mécanismes de perception visuelle. Différents facteurs d'influence comme une exposition repetee, le bypass gastrique Roux-en-Y, la motivation (état nutritionnel), ainsi que la densité énergétique de la nourriture qui est perçue ont pu être identifiés.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND/AIMS: Restenosis after percutaneous transluminal angioplasty (PTA) of the internal mammary artery (IMA) grafts is much less pronounced than in other arteries and venous grafts. The aim of the study was to test whether various arteries respond differently to dilatation. METHODS: PTA of the IMA, carotid, renal and circumflex coronary (RCx) arteries was performed in 9 pigs (balloon to artery ratio of 1:1.5). After 8 weeks, angiography was repeated and vessels prepared for histological analysis. Immunohistochemical staining was done to examine proliferative activity (Ki67) and to identify the vasa vasorum of the adventitia (F VIII-RA). RESULTS: The intima-media ratio after PTA was lowest in the IMA (0.06), followed by the carotid (0.27) and renal arteries (0.49) and the RCx (0.69). Proliferation of the intima was seen at 287 degrees of the vessel circumference in the RCx, at 286 degrees in the renal and at 166 degrees in the carotid artery. No proliferative activity was seen in the IMA. The intima-adventitia ratio was lower in the IMA than in the RCx and renal arteries (p &lt; 0.05). CONCLUSION: Intima proliferation after PTA varies between the different vessels, with best results seen in the IMA. There are differences in remodeling after PTA between muscular, muscular/elastic and elastic arteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: betaTC-tet (H2(k)) is a conditional insulinoma cell line derived from transgenic mice expressing a tetracycline-regulated oncogene. Transgenic expression of several proteins implicated in the apoptotic pathways increase the resistance of betaTC-tet cells in vitro. We tested in vivo the sensitivity of the cells to rejection and the protective effect of genetic alterations in NOD mice. METHODS: betaTC-tet cells and genetically engineered lines expressing Bcl-2 (CDM3D), a dominant negative mutant of MyD88 or SOCS-1 were transplanted in diabetic female NOD mice or in male NOD mice with diabetes induced by high-dose streptozotocin. Survival of functional cell grafts in NOD-scid mice was also analyzed after transfer of splenocytes from diabetic NOD mice. Autoreactive T-cell hybridomas and splenocytes from diabetic NOD mice were stimulated by betaTC-tet cells. RESULTS: betaTC-tet cells and genetically engineered cell lines were all similarly rejected in diabetic NOD mice and in NOD-scid mice after splenocyte transfer. In 3- to 6-week-old male NOD mice treated with high-dose streptozotocin, the cells temporarily survived, in contrast with C57BL/6 mice treated with high-dose streptozotocin (indefinite survival) and untreated 3- to 6-week-old male NOD mice (rejection). The protective effect of high-dose streptozotocin was lost in older male NOD mice. betaTC-tet cells did not stimulate autoreactive T-cell hybridomas, but induced IL-2 secretion by splenocytes from diabetic NOD mice. CONCLUSION/INTERPRETATION: The autoimmune process seems to play an important role in the destruction of betaTC-tet cells in NOD mice. Genetic manipulations intended at increasing the resistance of beta cells were inefficient. Similar approaches should be tested in vivo as well as in vitro. High dose streptozotocin influences immune rejection and should be used with caution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: Hyperglycaemia is now a recognized predictive factor of morbidity and mortality after coronary artery bypass grafting (CABG). For this reason, we aimed to evaluate the postoperative management of glucose control in patients undergoing cardiovascular surgery, and to assess the impact of glucose levels on in-hospital mortality and morbidity. METHODS: This was a retrospective study investigating the association between postoperative blood glucose and outcomes, including death, post-surgical complications, and length of stay in the intensive care unit (ICU) and in hospital. RESULTS: A total of 642 consecutive patients were enrolled into the study after cardiovascular surgery (CABG, carotid endarterectomy and bypass in the lower limbs). Patients' mean age was 68+/-10 years, and 74% were male. In-hospital mortality was 5% in diabetic patients vs 2% in non-diabetic patients (OR: 1.66, P=0.076). Having blood glucose levels in the upper quartile range (> or =8.8 mmol/L) on postoperative day 1 was independently associated with death (OR: 10.16, P=0.0002), infectious complications (OR: 1.76, P=0.04) and prolonged ICU stay (OR: 3.10, P<0.0001). Patients presenting with three or more hypoglycaemic episodes (<4.1 mmol/L) had increased rates of mortality (OR: 9.08, P<0.0001) and complications (OR: 8.57, P<0.0001). CONCLUSION: Glucose levels greater than 8.8 mmol/L on postoperative day 1 and having three or more hypoglycaemic episodes in the postoperative period were predictive of mortality and morbidity among patients undergoing cardiovascular surgery. This suggests that a multidisciplinary approach may be able to achieve better postoperative blood glucose control. Conclusion: Objectif: L'hyperglycémie a été reconnue comme facteur prédictif de morbidité et mortalité après un pontage aortocoronaire. Notre étude avait pour objectif d'évaluer la prise en charge postopératoire des glycémies chez les patients qui avaient subi une intervention chirurgicale cardiovasculaire et d'évaluer l'impact de ces glycémies sur la mortalité et la morbidité intrahospitalières. Méthodes: Étude rétrospective recherchant une association entre la glycémie postopératoire et les complications postchirurgicales, la mortalité et la durée du séjour aux soins intensifs et à l'hôpital. Résultats: L'étude a été réalisée sur 642 patients qui avaient subi une intervention chirurgicale cardiovasculaire (ex. pontage aortocoronaire, endartérectomie de la carotide, pontage artériel des membres inférieurs). L'âge moyen est de 68 ± 10 ans et 74 % des patients étaient de sexe masculin. La mortalité intrahospitalière a été de 5 % parmi les patients diabétiques et 2 % chez les non-diabétiques (OR 1,66, p = 0,076). Les taux de glycémies situés dans le quartile supérieur (≥ 8,8 mmol/l) à j1 postopératoire sont associés de manière indépendante avec la mortalité (OR 10,16, 95 % CI 3,20-39,00, p = 0,0002), les complications infectieuses (OR 1,76, 95 % CI 1,02-3,00, p = 0,04) et la durée du séjour aux soins intensifs (OR 3,10, 95 % CI 1,83-5,38, p < 0,0001). Les patients qui avaient présenté trois hypoglycémies ou plus (< 4,1 mmol/l) ont présenté un taux augmenté de mortalité (OR 9,08, p ≤ 0,0001) et de complications (OR 8,57, p < 0,0001). Conclusion : Des glycémies supérieures à 8,8 mmol/l à j1 postopératoire et la présence de trois hypoglycémies ou plus en période postopératoire sont des facteurs prédictifs de mauvais pronostic chez les patients qui avaient subi une intervention chirurgicale cardiovasculaire. Ainsi, une approche multidisciplinaire devrait être proposée afin d'obtenir un meilleur contrôle postopératoire des glycémies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental studies in nude mice with human colon-carcinoma grafts demonstrated the therapeutic efficiency of F(ab')2 fragments to carcinoembryonic antigen (CEA) labeled with a high dose of 131Iodine. A phase I/II study was designed to determine the maximum tolerated dose of 131I-labeled F(ab')2 fragments (131I-F(ab')2) from anti-CEA monoclonal antibody F6, its limiting organ toxicity and tumor uptake. Ten patients with non-resectable liver metastases from colorectal cancer (9 detected by CT scan and 1 by laparotomy) were treated with 131I-F(ab')2, doses ranging from 87 mCi to 300 mCi for the first 5 patients, with a constant 300-mCi dose for the last 5 patients. For all the patients, autologous bone marrow was harvested and stored before treatment. Circulating CEA ranged from 2 to 126 ng/ml. No severe adverse events were observed during or immediately following infusion of therapeutic doses. The 9 patients with radiologic evidence of liver metastases showed uptake of 131I-F(ab')2 in the metastases, as observed by single-photon-emission tomography. The only toxicity was hematologic, and no severe aplasia was observed when up to 250 mCi was infused. At the 300-mCi dose, 5 out of 6 patients presented grade-3 or -4 hematologic toxicity, with a nadir for neutrophils and thrombocytes ranging from 25 to 35 days after infusion. In these 5 cases, bone marrow was re-infused. No clinical complications were observed during aplasia. The tumor response could be evaluated in 9 out of 10 patients. One patient showed a partial response of one small liver metastasis (2 cm in diameter) and a stable evolution of the other metastases, 2 patients had stable disease, and 6 showed tumor progression at the time of evaluation (2 or 3 months after injection) by CT scan. This phase-I/II study demonstrated that a dose of 300 mCi of 131I-F(ab')2 from the anti-CEA Mab F6 is well tolerated with bone-marrow rescue, whereas a dose of 200 mCi can be infused without severe bone-marrow toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Posterior chest wall defects are frequently encountered after excision of tumors as a result of trauma or in the setting of wound dehiscence after spine surgery. Various pedicled fasciocutaneous and musculocutaneous flaps have been described for the coverage of these wounds. The advent of perforator flaps has allowed the preservation of muscle function but their bulk is limited. Musculocutaneous flaps remain widely employed. The trapezius and the latissimus dorsi (LD) flaps have been used extensively for upper and middle posterior chest wounds, respectively. Their bulk allows for obliteration of the dead space in deep wounds. The average width of the LD skin paddle is limited to 10-12 cm if closure of the donor site is expected without skin grafting. In 2001 a modification of the skin paddle design was introduced in order to allow large flaps to be raised without requiring grafts or flaps for donor site closure. This V-Y pattern allows coverage of large anterior chest defects after mastectomy. We have modified this flap to allow its use for posterior chest wall defects. We describe the flap design, its indications, and its limitations with three clinical cases. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266 .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Use of cardiopulmonary bypass for emergency resuscitation is not new. In fact, John Gibbon proposed this concept for the treatment of severe pulmonary embolism in 1937. Significant progress has been made since, and two main concepts for cardiac assist based on cardiopulmonary bypass have emerged: cardiopulmonary support (CPS) and extracorporeal membrane oxygenation (ECMO). The objective of this review is to summarize the state of the art in these two technologies. METHODS: Configuration of CPS is now fairly standard. A mobile cart with relatively large wheels allowing for easy transportation carries a centrifugal pump, a back-up battery with a charger, an oxygen cylinder, and a small heating system. Percutaneous cannulation, pump-driven venous return, rapid availability, and transportability are the main characteristics of a CPS system. Cardiocirculatory arrest is a major predictor of mortality despite the use of CPS. In contrast, CPS appears to be a powerful tool for patients in cardiogenic shock before cardiocirculatory arrest, requiring some type of therapeutic procedures, especially repair of anatomically correctable problems or bridging to other mechanical circulatory support systems such as ventricular assist devices. CPS is in general not suitable for long-term applications because of the small-bore cannulas, resulting in significant pressure gradients and eventually hemolysis. RESULTS: In contrast, ECMO can be designed for longer-term circulatory support. This requires large-bore cannulas and specifically designed oxygenators. The latter are either plasma leakage resistent (true membranes) or relatively thrombo-resistant (heparin coated). Both technologies require oxygenator changeovers although the main reason for this is different (clotting for the former, plasma leakage for the latter). Likewise, the tubing within a roller pump has to be displaced and centrifugal pump heads have to be replaced over time. ECMO is certainly the first choice for a circulatory support system in the neonatal and pediatric age groups, where the other assist systems are too bulky. ECMO is also indicated for patients improving on CPS. Septic conditions are, in general, considered as contraindications for ECMO. CONCLUSIONS: Ease of availability and moderate cost of cardiopulmonary bypass-based cardiac support technologies have to be balanced against the significant immobilization of human resources, which is required to make them successful.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: Hyperglycaemia is now a recognized predictive factor of morbidity and mortality after coronary artery bypass grafting (CABG). For this reason, we aimed to evaluate the postoperative management of glucose control in patients undergoing cardiovascular surgery, and to assess the impact of glucose levels on in-hospital mortality and morbidity. METHODS: This was a retrospective study investigating the association between postoperative blood glucose and outcomes, including death, post-surgical complications, and length of stay in the intensive care unit (ICU) and in hospital. RESULTS: A total of 642 consecutive patients were enrolled into the study after cardiovascular surgery (CABG, carotid endarterectomy and bypass in the lower limbs). Patients' mean age was 68+/-10 years, and 74% were male. In-hospital mortality was 5% in diabetic patients vs 2% in non-diabetic patients (OR: 1.66, P=0.076). Having blood glucose levels in the upper quartile range (> or =8.8 mmol/L) on postoperative day 1 was independently associated with death (OR: 10.16, P=0.0002), infectious complications (OR: 1.76, P=0.04) and prolonged ICU stay (OR: 3.10, P<0.0001). Patients presenting with three or more hypoglycaemic episodes (<4.1 mmol/L) had increased rates of mortality (OR: 9.08, P<0.0001) and complications (OR: 8.57, P<0.0001). CONCLUSION: Glucose levels greater than 8.8 mmol/L on postoperative day 1 and having three or more hypoglycaemic episodes in the postoperative period were predictive of mortality and morbidity among patients undergoing cardiovascular surgery. This suggests that a multidisciplinary approach may be able to achieve better postoperative blood glucose control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute massive pulmonary embolism (PE) is a life-threatening event. Before the era of cardiopulmonary bypass, acute pulmonary embolectomy had been historically attempted in patients with severe hemodynamic compromise. The Klippel-Trenaunay syndrome (KTS) represents a significant life-long risk for major thromboembolic events. We present two young patients with Klippel-Trenaunay syndrome who survived surgical embolectomy after massive PE and cardiopulmonary resuscitation, with good postoperative recovery. Even though the role of surgical embolectomy in massive PE is not clearly defined, with current technology it can be life saving and can lead to a complete recovery, especially in young patients as described in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors present the case of an open fracture of femur Cauchoix type II with an infection due to Escherichia coli, Clostridium perfringens, Enterococcus and Aspergillus fumigatus. After several sequestrectomies and five hyperbaric sessions, apyrexia was attained at the end of the third month, the femur having been stabilised with an external fixator. The 15 cm gap due to loss of bone substance, filled at each dressing with an antiseptic iodine based ointment, closed itself finishing as continuous bone five months after the accident, the granulation tissue having been recovered by thin skin grafts. A repeated fracture occurring forty-eight hours after the removal of the Hoffmann frame was treated by fitting an Ilizarov fixator arriving at consolidation in seven months. The authors examine different possibilities of accelerating osteogenesis and highlight the potential role of iodine ointment as inductive to osteogenesis stemming from a periosteal layer seemingly held in place.