957 resultados para Angular scan
Resumo:
Objective: To evaluate the percutaneous Achilles tendon sectioning technique using a large gauge needle for the correction of residual equinus of congenital clubfoot treated with the Ponseti method. Methods: Fifty-seven Achilles tendon sections were prospectively evaluated in thirty-nine patients with clubfoot, treated with the Ponseti method between July 2005 and December 2008. The tenotomy was performed percutaneously with a large gauge needle. Ultrasound scan was performed immediately after the section, to ascertain whether the tenotomy was complete, as well as stump separation. Results: There was complete tendon section in all cases, but the need to perform the section maneuver more than once was common, due to the persistence of the residual strands between tendon stumps. The Thompson test and dynamic ultrasound evaluation were able to detect incomplete tenotomies. The mean ultrasound measurement of the tendon gap was 5.70 +/- 2.23 mm. Two patients had abnormal bleeding, which was controlled by digital pressure and did not compromise foot perfusion. Conclusion: Percutaneous Achilles tendon sectioning with a needle proved to be efficient and safe to correct residual equinus of clubfoot treated with the Ponseti technique.
Resumo:
Objective: The objective of the study was to compare the functional and aesthetic results of fractured orbital wall reconstruction with an auricular cartilage graft or absorbable polyacid copolymer. Materials and Methods: Twenty patients with blow-out orbital fracture/orbital floor associated or not with the medial wall were assessed by the same craniofacial surgical group. All were evaluated preoperatively and postoperatively by an ophthalmologist for diplopia, enophthalmos, exophthalmos, sensitivity, ophthalmic reflexes, intraocular pressure, and visual field. The patients were subjected to a preoperative facial multislice computed tomographic scan, repeated 6 months after surgery. Eight patients underwent reconstruction with an auricular cartilage graft, and 12 patients, with blade absorbable polyacid copolymer. Subtarsal access was used for all patients. Results: Two patients showed temporary ectropion, 1 in each group. All patients presented satisfactory ocular function, and all tests revealed good orbital delineation, orbital symmetry, periorbital sinus individualization, and reduction of blow-out. Conclusions: The blow-out orbital wall reconstruction can be performed with the use of an auricular cartilage or with a blade absorbable copolymer without differences regarding functional or aesthetic complications and sequelae.
Resumo:
Purpose: To describe the clinical and radiologic features of orbital involvement in craniofacial brown tumors and to compare the rate of brown tumors in primary and secondary hyperparathyroidism. Methods: A retrospective hospital-based study of 115 patients with chronic kidney disease and secondary hyperparathyroidism and 34 with primary hyperparathyroidism was conducted. Laboratory results such as serum levels of alkaline phosphatase, calcium, phosphorus, and parathyroid hormone were recorded. Demographic data (age, sex, duration of disease) and image findings (bone scan scintigraphy, skull and long bone x-rays, CT) were also obtained. The main outcome measures were analysis of clinical, biochemical, and radiologic findings of all patients. Results: Of the 115 patients with chronic kidney disease, 10 (8.7%) had brown tumors in different bones of the skeleton. Five patients had lesions in the craniofacial bones. The maxilla, mandible, maxillary sinus, and nasal cavity were the most affected sites. The orbit was involved in 2 patients with lesions arising in the maxillary and ethmoid sinuses. One patient had facial leontiasis. All patients with brown tumors had extremely high levels of parathyroid hormone (>1,000 pg/ml, normal values 10-69 pg/ml) and alkaline phosphatase (>400 U/l, normal values 65-300 U/l). The mean serum levels of phosphorus and calcium were not abnormal among the patients with brown tumors. Age and time of renal failure were similar for patients with and without brown tumors. Among the patients with primary hyperparathyroidism, only 2 (5.8%) had brown tumors, and in just 1, the lesion was localized in the craniofacial skeleton. A 2-tailed Z test applied to compare the proportion of occurrence of brown tumors in the 2 groups revealed that the difference at the 90% of confidence level was not significant. Conclusions: Brown tumors are equally found in secondary and primary hyperparathyroidism. Craniofacial brown tumors involve the orbit, usually because of the osteodystrophy process that involves the maxilla and paranasal sinuses. The lesions do not necessarily need to be excised and may regress spontaneously after the control of hyperparathyroidism.
Resumo:
Bovine leukemia virus (BLV) is among the most widespread livestock pathogens in many countries. Despite advances in understanding the pathogenesis of this disease, little is known about the involvement of oxidative stress. Therefore, this study examined the antioxidant status and the markers of oxidative stress in BLV-infected dairy cows. BLV infection was associated with an increase in triacylglycerol levels, a decrease in glutathione peroxidase (GSH-Px) activity and a tendency toward lower superoxide dismutase activity in the infected animals. No significant difference was observed in other markers of oxidative stress (i.e., conjugated dienes, hydroperoxides and malondialdehyde) in the infected animals compared to controls. A novel method for the analysis of oxidative stress, Z-scan based on the measurement of the mean-value of 9 in low density lipoprotein indicated that the infected animals had low-density lipoprotein particles that were slightly less modified than those from the healthy group. Thus, we conclude that BLV infection is associated with a selective decrease in GSH-Px activity without any alteration in the common plasma markers of oxidative stress. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Objective: To determine the oral status, salivary flow rate, Candida carriage in saliva, and prevalence of Candida albicans colonization in several areas of the mouth in patients with primary and secondary Sjogren`s syndrome as opposed to those of healthy subjects. Study design: Thirty-seven patients with Sjogren`s syndrome (SS), [14 patients with primary SS (SS-1) and 23 patients with secondary SS (SS-2)], along with 37 healthy controls were examined in regard to number of teeth, pro-bing pocket depth (PPD), approximal plaque index (API), bleeding on probing (BOP), presence of prosthetic appliances and smoking habits. Salivary flow rate (SFR), Candida carriage in saliva, presence of Candida albicans colonization on buccal, angular, palatal and sulcular areas, on dentures and on the tongue`s dorsal surface were determined. Statistical analyses were performed using the 2-tailed Fisher exact and Kruskal-Wallis test. Results: No statistically significant difference was found between SS-1 and SS-2 groups based on the parameters analysed. Statistically significant differences were observed between patients with SS and healthy subjects in terms of SFR, oral signs and symptoms, API, BOP, C. albicans colonization on tongue and buccal area, and Candida carriage in saliva. In the gingival crevicular fluid positive C. albicans colonization was found in only one subject of SS subgroup. Conclusions: SS patients carry a higher risk of having periodontitis and are more predisposed to develop candidiasis. C. albicans is scarcely detected in gingival crevicular fluid despite high scores on C. albicans colonization in different areas of the oral cavity in SS patients.
Resumo:
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)
Resumo:
Objective: To describe the clinical, speech, hearing, and imaging findings in three members of a Brazilian family with Saethre-Chotzen syndrome (SCS) who presented some unusual characteristics within the spectrum of the syndrome. Design: Clinical evaluation was performed by a multidisciplinary team. Direct sequencing of the polymerase chain reaction amplified coding region of the TWIST1 gene, routine and electrophysiological hearing evaluation, speech evaluation, and imaging studies through computed tomography (CT) scan and magnetic resonance imaging (MRI) were performed. Results: TWIST1 gene analysis revealed a Pro136His mutation in all patients. Hearing evaluation showed peripherial and mixed hearing loss in two of the patients, one of them with severe unilateral microtia. Computed tomography scan showed structural middle ear anomalies, and MRI showed distortion of the skull contour as well as some of the brain structures. Conclusions: We report a previously undescribed TWIST1 gene mutation in patients with SCS. There is evidence that indicates hearing loss (conductive and mixed) can be related both with middle ear (microtia, high jugular bulb, and enlarged vestibules) as well as with brain stem anomalies. Here we discuss the relationship between the gene mutation and the clinical, imaging, speech, and hearing findings.
Resumo:
Introduction: In this study, we compared the dentoalveolar changes of Class II patients treated with Jones jig and pendulum appliances. Methods: The experimental group comprised 40 Class II malocclusion subjects, divided into 2 groups: group 1 consisted of 20 patients (11 boys, 9 girls) at a mean pretreatment age of 13.17 years, treated with the Jones jig appliance for 0.91 years; group 2 comprised 20 patients (8 boys, 12 grls) at a mean pretreatment age of 13.98 years, treated with the pendulum appliance for 1.18 years. Only active treatment time of molar distalization was evaluated in the predistalization and postdistalization lateral cephalograms. Molar, second premolar, and incisor angular and linear variables were obtained. The intergroup treatment changes in these variables were compared with independent t tests. Results: The maxillary second premolars showed greater mesial tipping and extrusion in the Jones jig group, indicating more anchorage loss during molar distalization with this appliance. The amounts and the monthly rates of molar distalization were similar in both groups. Conclusions: The Jones jig group showed greater mesial tipping and extrusion of the maxillary second premolars. The mean amounts and the monthly rates of first molar distalization were similar in both groups. (Am J Orthod Dentofacial Orthop 2009;135:336-42)
Resumo:
Introduction: In premolar extraction cases, root parallelism is recommended to preserve the stability of space closures. The influence of the degree of root parallelism on relapse of tooth extraction spaces has been a controversial topic in the literature. The aim of this study was to compare the angle between the long axes of the canine and the second premolarin patients with and without stability of extraction-space closures. Methods: A sample of 56 patients, treated with 4 premolar extractions, was divided into 2 groups: group 1, consisting of 25 patients with reopening of extraction spaces; and group 2, consisting of 31 patients without reopening of extraction spaces. Panoramic radiographs of each patient were analyzed at the posttreatment and 1-year posttreatment stages. The data were statistically analyzed by using chi-square tests, t tests, analysis of variance (ANOVA), and Pearson correlation coefficients. Results: The results showed that the groups did not differ regarding the angle between the canine and the second premolar, and there was no correlation between angular changes and reopening of extraction spaces, showing that dental angular changes are not determining factors for relapse, and other factors should be investigated. Conclusions: The final angle and the posttreatment changes observed in the angle between the long axes of the canine and the second premolar showed no influence on the relapse of extraction spaces. (Am J Orthod Dentofacial Orthop 2011; 139: e505-e510)
Resumo:
The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.
Resumo:
We observe no evidence of linkage to the region around the PPARG locus in several samples of DZ twins who have been genotyped at multiple markers on chromosome 3 (Fig. 1). Among 199 Australian DZ twins ascertained for a history of wheezing2, mean identity by descent (IBD) sharing at the position of PPARG is 0.463 (99% bootstrapped confidence interval=0.412−0.516). We obtained a similar result with 232 pairs of Australian adolescent DZ twins taking part in a longitudinal study of naevus development3 (0.444, 0.390−0.499), and a set of 125 Australian adult DZ twin pairs assessed for anxiety4 (0.508, 0.435−0.580). A Dutch scan of 160 DZ twin pairs5 obtained slightly more encouraging results (0.553, 0.482−0.587, peak maximum lod score (MLS)=0.57). Pooling all these samples gives 0.477 (0.454−0.512) at the position of PPARG. The test for heterogeneity of sharing between studies was not significant (P=0.10). In the combined dataset, the peak IBD sharing (MLS=0.70) is 50 cM closer to the centromere than PPARG. Finally, in a sample of 203 Australian and New Zealand sister pairs where each had given birth to DZ twins6, sharing across the region is also not increased (0.433). We do not replicate linkage in the populations we study to survival of a twin pregnancy or polyovulation.
Resumo:
Polarized absorption and emission spectra of trigonal single crystals of an Er(III) complex coordinated to a heptadentate tripodal ligand are reported at temperatures between 8 and 298 K. The assigned energy levels below the onset of ligand absorption (< 25 000 cm(-1)) are fitted to a parametrized electronic Hamiltonian. The C-3 site symmetry of the Er(HI) ion requires eight parameters for a full description of the ligand field within a one-electron operator description. This compound shows unusually large splittings of the multiplets, and the fitted parameters imply that this heptadentate ligand imparts the largest ligand field reported for an Er(III) complex. The ligand field was also interpreted within the angular overlap model (AOM). We derive the AOM matrix to include both sigma and anisotropic pi bonding and show that a useful description of the C-3 ligand field can be made using only five parameters. The success of the AOM description is encouraging for applications on isomorphous complexes within the lanthanide series and in describing the ligand field of low-symmetry complexes with less parameters than in the usual spherical harmonic expansion.
Resumo:
When visual information is confined to one object plane, the emmetropization end-point is adjusted in accord with the corresponding incident optical vergence at the eye [Proceedings of the 7th International Conference on Myopia (2000) 113]. We now report the effect of adding extra visual information beyond the target plane. Visual conditions were controlled using a cone-lens system: black Maltese cross targets on white opaque backgrounds (OMX) were attached to the open faces of 2.5 cm translucent cones fitted with either 0, +25 or +40 D imaging lenses. An alternative target (TMX) was made by substituting the opaque target background for a transparent background, which allowed access to visual information beyond the target plane. The imaging devices were applied to 7-day-old chicks and worn for 4 days. Prior to this treatment, on day 2, some chicks underwent ciliary nerve section (CNS) to preclude accommodation. All treatments were monocular. Refractive errors and axial ocular dimensions were measured using retinoscopy and A-scan ultrasonography under halothane anesthesia. Treatment effects were specified as mean ( +/-S.D.) interocular differences. Eyes with the OMX/ + 40 D lens combination remained emmetropic ( +0.73 +/-3.57 D), consistent with the target plane being approximately conjugate with the retina. Switching to the TMX caused a hyperopic shift in refractive error ( + 3.78 +/- 3.41 D). This relative shift towards hyperopia in switching from the OMX to the TMX target also occurred for the other two lens powers. Thus, the OMX/ + 25 D lens induced myopia ( - 7.00 +/-5.88 D), corresponding to the imposed hyperopic defocus (target plane now imaged behind the retina), and switching to the TMX resulted in a reduction in myopia (-1.73 +/-5.36 D), The OMX/0 D lens combination produced the largest myopic shift, and here, switching to the TMX condition almost eliminated the myopic response (-15.50 +/-6.62 D cf. -0.56 +/-1.24 D). This relative hyperopic shift associated with switching from the OMX to the TMX target was eliminated by CNS surgery. Thus, the two CNS/TMX groups were both more myopic than the equivalent no CNS/TMX groups ( + 40 D lens: -2.66 +/-2.34 D; +25 D lens: -7.97 +/-6.87 D). When the visual information is restricted to one plane, incident optical vergence appears to direct emmetropization. Adding Visual information at other distances produces a shift in the end-point of ernmetropization in the direction of the added information. That these effects are dependent on the integrity of the accommodation system implies that accommodation plays a role in emmetropization and represents the first reported evidence of this kind. Published by Elsevier Science Ltd.