852 resultados para Anatomía ocular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Optómetra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometría, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Optómetra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometría, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Optometra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometria, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyze the consequences of unilateral and bilateral ablation based on ovigerous percentage, consecutive spawns, and secondary effects of the surgical process in the females of Macrobrachium rosenbergii (De Man, 1879). Two experiments were carried out with four and seven months old females in intermolt stage. Each experiment was comprised of control, unilateral and bilateral ablation. Eyestalk ablation was done with a bistoury with a topic hot cauterization followed by application of antibiotic pomades. The animals were maintained at constant temperature (28 ± 1,05ºC) and photoperiod of 12L: 12D within fibercement boxes with sandy bottom and biological filter. Females were observed once a day during fourteen weeks, registering gonadal condition, ecdysis and presence of spermatophore (mating) and spawning. Unilateral ablation technique is more efficient due to the anticipation of the first spawn, repeatability between spawns, expressive rate of ovigerous females and survival, that favored its applicability. Bilateral eyestalk ablation produced the mortality of ali the females with change in coloration and food activity patterns. These results corroborate other observations on penaeid shrimps. though bilateral ablation on some lobsters was a success. These results showing an interespecific variation and can be used in aquaculture projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To fabricate ultra-small algal chitosan nanoparticles (US CS NPs) for efficient delivery of bovine lactoferrin (bLf) to ocular tissues through topical administration to prevent carbendazim-induced toxicity. MATERIALS & METHODS: Rat eye model was used to evaluate the in vivo biodistribution the US CS NPs and bovine eye model was used for evaluating ex vivo biodistribution. Human lens epithelial cell line (HLEB-3) model was used to evaluate the in vitro toxicity, uptake mechanism and in vitro efficacy of the synthesized bLf-US CS NPs over carbendazim-induced ocular toxicity. RESULTS: The in vivo and ex vivo biodistribution results suggest that the ultra-small CS NPs efficiently internalize into the ocular tissues within 1 h after administering topically. Ultra-small algal nanocarriers to encapsulate bioactive antioxidant bLf protein and evaluated its potential in inhibiting carbendazim-induced human lens cell apoptosis and oxidative stress. CONCLUSION: US CS NPs could be explored for their potential for delivering various ocular drugs through topical administration for other eye diseases including cataract, glaucoma and age-related macular degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the progress of computer technology, computers are expected to be more intelligent in the interaction with humans, presenting information according to the user's psychological and physiological characteristics. However, computer users with visual problems may encounter difficulties on the perception of icons, menus, and other graphical information displayed on the screen, limiting the efficiency of their interaction with computers. In this dissertation, a personalized and dynamic image precompensation method was developed to improve the visual performance of the computer users with ocular aberrations. The precompensation was applied on the graphical targets before presenting them on the screen, aiming to counteract the visual blurring caused by the ocular aberration of the user's eye. A complete and systematic modeling approach to describe the retinal image formation of the computer user was presented, taking advantage of modeling tools, such as Zernike polynomials, wavefront aberration, Point Spread Function and Modulation Transfer Function. The ocular aberration of the computer user was originally measured by a wavefront aberrometer, as a reference for the precompensation model. The dynamic precompensation was generated based on the resized aberration, with the real-time pupil diameter monitored. The potential visual benefit of the dynamic precompensation method was explored through software simulation, with the aberration data from a real human subject. An "artificial eye'' experiment was conducted by simulating the human eye with a high-definition camera, providing objective evaluation to the image quality after precompensation. In addition, an empirical evaluation with 20 human participants was also designed and implemented, involving image recognition tests performed under a more realistic viewing environment of computer use. The statistical analysis results of the empirical experiment confirmed the effectiveness of the dynamic precompensation method, by showing significant improvement on the recognition accuracy. The merit and necessity of the dynamic precompensation were also substantiated by comparing it with the static precompensation. The visual benefit of the dynamic precompensation was further confirmed by the subjective assessments collected from the evaluation participants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMEN Objetivo: Estimar la prevalencia de las diferentes enfermedades oftalmológicas que aparecen en el contexto de una enfermedad autoinmune (EAI) en pacientes de un centro de referencia reumatológica en Colombia, según características clínicas y sociodemográficas durante un período de 15 años, comprendido entre los años 2000 a 2015. Métodos: Se realizó un estudio descriptivo, observacional de prevalencia. El tipo de muestreo fue aleatorio estratificado con asignación proporcional en el programa Epidat 3.4. Los datos se analizaron en el programa SPSS v22.0 y se realizó análisis univariado de las variables categóricas, para las variables cuantitativas se realizaron medidas de tendencia central. Resultados: De 1640 historias clínicas revisadas, se encontraron 634 pacientes (38,65%) con compromiso ocular. Si excluimos los pacientes con SS, que por definición presentan ojo seco, 222 pacientes (13,53%) presentaron compromiso oftalmológico. Del total de pacientes, el 83,3% fueron mujeres. La AR fue la enfermedad autoinmune con mayor compromiso oftalmológico con 138 pacientes (62,2%), y en último lugar la sarcoidosis con 1 solo paciente afectado. La QCS fue la manifestación más común en todos los grupos diagnósticos de EAI, con 146 pacientes (63,5%). De 414 pacientes con Síndrome de Sjögren (SS) y QCS 8 presentaron compromiso ocular adicional, siendo la uveítis la segunda patología ocular asociada en pacientes con SS y la primera causa en las espondiloartropatias (71,4 %). Los pacientes con catarata (4,1%) presentaron la mayor prevalencia de uso de corticoide (88.8%). De 222 pacientes, 28 (12,6%) presentaron uveítis. Del total de pacientes, 16 (7,2%) presentaron maculopatía por antimalaráricos y 6 (18,75%) de los pacientes con LES. Los ANAS se presentaron en el 100% los pacientes con trastorno vascular de la retina. Los pacientes con epiescleritis presentaron la mayor proporción de positivización de anticuerpos anti-DNA. La EAI que más presentó epiescleritis fue LES con 4 pacientes (12,5%) El 22% de paciente con anticuerpos anti-RNP presentaron escleritis y 32,1% de los pacientes con uveítis presentaron HLA-B27 positivo. Las manifestaciones oftalmológicas precedieron a las sistémicas entre un 11,1% y un 33,3% de los pacientes. Conclusión: Las enfermedades oculares se presentan con frecuencia en los pacientes colombianos con EAI (38.65%), siendo la AR la enfermedad con mayor compromiso ocular (62,2%) y la QCS la enfermedad ocular con mayor prevalencia en todas las EAI (63,5%). La uveítis se presentó en 28 pacientes (12,6%). Las manifestaciones oftalmológicas pueden preceder a las sistémicas. El examen oftalmológico debe ser incluido en los pacientes con EAI, por ser la enfermedad ocular una comorbilidad frecuente. Adicionalmente, los efectos oftalmológicos de las medicaciones sistémicas utilizadas en EAI deben ser estrechamente monitorizados, durante el curso del tratamiento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To introduce techniques for deriving a map that relates visual field locations to optic nerve head (ONH) sectors and to use the techniques to derive a map relating Medmont perimetric data to data from the Heidelberg Retinal Tomograph. METHODS: Spearman correlation coefficients were calculated relating each visual field location (Medmont M700) to rim area and volume measures for 10 degrees ONH sectors (HRT III software) for 57 participants: 34 with glaucoma, 18 with suspected glaucoma, and 5 with ocular hypertension. Correlations were constrained to be anatomically plausible with a computational model of the axon growth of retinal ganglion cells (Algorithm GROW). GROW generated a map relating field locations to sectors of the ONH. The sector with the maximum statistically significant (P < 0.05) correlation coefficient within 40 degrees of the angle predicted by GROW for each location was computed. Before correlation, both functional and structural data were normalized by either normative data or the fellow eye in each participant. RESULTS: The model of axon growth produced a 24-2 map that is qualitatively similar to existing maps derived from empiric data. When GROW was used in conjunction with normative data, 31% of field locations exhibited a statistically significant relationship. This significance increased to 67% (z-test, z = 4.84; P < 0.001) when both field and rim area data were normalized with the fellow eye. CONCLUSIONS: A computational model of axon growth and normalizing data by the fellow eye can assist in constructing an anatomically plausible map connecting visual field data and sectoral ONH data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retinal image properties such as contrast and spatial frequency play important roles in the development of normal vision. For example, visual environments comprised solely of low contrast and/or low spatial frequencies induce myopia. The visual image is processed by the retina and it then locally controls eye growth. In terms of the retinal neurotransmitters that link visual stimuli to eye growth, there is strong evidence to suggest involvement of the retinal dopamine (DA) system. For example, effectively increasing retinal DA levels by using DA agonists can suppress the development of form-deprivation myopia (FDM). However, whether visual feedback controls eye growth by modulating retinal DA release, and/or some other factors, is still being elucidated. This thesis is chiefly concerned with the relationship between the dopaminergic system and retinal image properties in eye growth control. More specifically, whether the amount of retinal DA release reduces as the complexity of the image degrades was determined. For example, we investigated whether the level of retinal DA release decreased as image contrast decreased. In addition, the effects of spatial frequency, spatial energy distribution slope, and spatial phase on retinal DA release and eye growth were examined. When chicks were 8-days-old, a cone-lens imaging system was applied monocularly (+30 D, 3.3 cm cone). A short-term treatment period (6 hr) and a longer-term treatment period (4.5 days) were used. The short-term treatment tests for the acute reduction in DA release by the visual stimulus, as is seen with diffusers and lenses, whereas the 4.5 day point tests for reduction in DA release after more prolonged exposure to the visual stimulus. In the contrast study, 1.35 cyc/deg square wave grating targets of 95%, 67%, 45%, 12% or 4.2% contrast were used. Blank (0% contrast) targets were included for comparison. In the spatial frequency study, both sine and square wave grating targets with either 0.017 cyc/deg and 0.13 cyc/deg fundamental spatial frequencies and 95% contrast were used. In the spectral slope study, 30% root-mean-squared (RMS) contrast fractal noise targets with spectral fall-off of 1/f0.5, 1/f and 1/f2 were used. In the spatial alignment study, a structured Maltese cross (MX) target, a structured circular patterned (C) target and the scrambled versions of these two targets (SMX and SC) were used. Each treatment group comprised 6 chicks for ocular biometry (refraction and ocular dimension measurement) and 4 for analysis of retinal DA release. Vitreal dihydroxyphenylacetic acid (DOPAC) was analysed through ion-paired reversed phase high performance liquid chromatography with electrochemical detection (HPLC-ED), as a measure of retinal DA release. For the comparison between retinal DA release and eye growth, large reductions in retinal DA release possibly due to the decreased light level inside the cone-lens imaging system were observed across all treated eyes while only those exposed to low contrast, low spatial frequency sine wave grating, 1/f2, C and SC targets had myopic shifts in refraction. Amongst these treatment groups, no acute effect was observed and longer-term effects were only found in the low contrast and 1/f2 groups. These findings suggest that retinal DA release does not causally link visual stimuli properties to eye growth, and these target induced changes in refractive development are not dependent on the level of retinal DA release. Retinal dopaminergic cells might be affected indirectly via other retinal cells that immediately respond to changes in the image contrast of the retinal image.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5 mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defocus blur limits of six subjects with uncorrected intrinsic higher-order ocular aberrations ranged from 0.18 ± 0.08 D (noticeable blur criterion, 0.1 logMAR) to 1.01 ± 0.27 D (objectionable blur criterion, 0.6 logMAR. Crossed-cylinder astigmatic blur limits were approximately 90% of those for defocus, but with considerable meridional influences. In two of the subjects, the intrinsic aberrations of the eye were subsequently corrected before the defocus and astigmatic blur were added. This resulted in only minor reductions in their blur limits. When assessed with trefoil blur and corrected intrinsic ocular aberrations, the ratio of objectionable to noticeable blur limits in these two subjects was much higher for trefoil (3.5) than for defocus (2.5) and astigmatism (2.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the clinical signs, symptoms, and ocular and systemic comorbidities in a large case series of contact lens-related microbial keratitis. Methods: Two hundred ninety-seven cases of contact lens-related microbial keratitis, aged between 15 and 64 years were detected through surveillance of hospital and community based ophthalmic practitioners in Australia and New Zealand. Full clinical data were available for 190 cases and 90 were interviewed by telephone. Clinical data included the size, location, and degree of anterior chamber response. Symptom data were available from the practitioner and from participant self-report. Associations between symptoms and disease severity were evaluated. Data on ocular and systemic disease were collected from participants and practitioners. The frequency of comorbidities was compared between the different severities of disease and to population norms. Results: More severe disease was associated with greater symptom severity and pain was the most prevalent symptom reported. Ninety-one percent of cases showed progression of ocular symptoms after lens removal, and symptom progression was associated with all severities of disease. Twenty-five percent of cases reported prior episodes requiring emergency attention. Thyroid disease (p 0.05) and self-reported poor health (p 0.001) were more common in cases compared with age-matched population norms. Discussion: Information on the signs, symptoms, and comorbidities associated with contact lens-related microbial keratitis may be useful in patient education and for practitioners involved in the fitting of lenses and management of complications. Although pain was the most common symptom experienced, progression of symptoms despite lens removal was close to universal. Poor general health, particularly respiratory disease and thyroid disease was more common in cases than in the general population, which may prompt practitioners to recommend flexibility in wear schedules when in poor health or the selection of a lower risk wear schedule in at risk patients