951 resultados para Actuarial instrument


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Associations between parenting style and depressive symptomatology in a community sample of young adolescents (N = 2596) were investigated using self-report measures including the Parental Bonding Instrument and the Center for Epidemiologic Studies Depression Scale. Specifically, the 25-item 2-factor and 3-factor models by Parker et al. (1979), Kendler's (1996) 16-item 3-factor model, and Parker's (1983) quadrant model for the Parental Bonding Instrument were compared. Data analysis included analysis of variance and logistic regression. Reanalysis of Parker's original scale indicates that overprotection is composed of separate factors: intrusiveness (at the individual level) and restrictiveness (in the social context). All models reveal significant independent contributions from paternal care, maternal care, and maternal overprotection (2-factor) or intrusiveness (3-factor) to moderate and serious depressive symptomatology, controlling for sex and family living arrangement. Additive rather than multiplicative interactions between care and overprotection were found. Regardless of the level of parental care and affection, clinicians should note that maternal intrusiveness is strongly associated with adverse psychosocial health in young adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To demonstrate properties of the International Classification of the External Cause of Injury (ICECI) as a tool for use in injury prevention research. Methods: The Childhood Injury Prevention Study (CHIPS) is a prospective longitudinal follow up study of a cohort of 871 children 5 - 12 years of age, with a nested case crossover component. The ICECI is the latest tool in the International Classification of Diseases (ICD) family and has been designed to improve the precision of coding injury events. The details of all injury events recorded in the study, as well as all measured injury related exposures, were coded using the ICECI. This paper reports a substudy on the utility and practicability of using the ICECI in the CHIPS to record exposures. Interrater reliability was quantified for a sample of injured participants using the Kappa statistic to measure concordance between codes independently coded by two research staff. Results: There were 767 diaries collected at baseline and event details from 563 injuries and exposure details from injury crossover periods. There were no event, location, or activity details which could not be coded using the ICECI. Kappa statistics for concordance between raters within each of the dimensions ranged from 0.31 to 0.93 for the injury events and 0.94 and 0.97 for activity and location in the control periods. Discussion: This study represents the first detailed account of the properties of the ICECI revealed by its use in a primary analytic epidemiological study of injury prevention. The results of this study provide considerable support for the ICECI and its further use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objective: To describe the diagnostic accuracy and practical application of the Peter James Centre Falls Risk Assessment Tool (PJC-FRAT), a multidisciplinary falls risk screening and intervention deployment instrument. Methods: In phase 1, the accuracy of the PJC-FRAT was prospectively compared to a gold standard (the STRATIFY) on a cohort of subacute hospital patients (n = 122). In phase 2, the PJC-FRAT was temporally reassessed using a subsequent cohort (n = 316), with results compared to those of phase 1. Primary outcomes were falls (events), fallers (patients who fell), and hospital completion rates of the PJC-FRAT. Results: In phase 1, PJC-FRAT accuracy of identifying falters showed sensitivity of 73% (bootstrap 95% confidence interval CI = 55, 90) and specificity of 75% (95% CI = 66, 83), compared with the STRATIFY (cutoff >= 2/5) sensitivity of 77% (95% CI = 59, 92) and specificity of 51% (95% CI = 41, 61). This difference was not significant. In phase 2, accuracy of nursing staff using the PJC-FRAT was lower. PJC-FRAT completion rates varied among disciplines over both phases: nurses and physiotherapists, >= 90%; occupational therapists, >= 82%; and medical officers, >= 57%. Conclusion: The PJC-FRAT was practical and relatively accurate as a predictor of falls and a deployment instrument for falls prevention interventions, although continued staff education may be necessary to maintain its accuracy. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phospholipids are complex and varied biomolecules that are susceptible to lipid peroxidation after attack by free radicals or electrophilic oxidants and can yield a large number of different oxidation products. There are many available methods for detecting phospholipid oxidation products, but also various limitations and problems. Electrospray ionization mass spectrometry allows the simultaneous but specific analysis of multiple species with good sensitivity and has a further advantage that it can be coupled to liquid chromatography for separation of oxidation products. Here, we explain the principles of oxidized phospholipid analysis by electrospray mass spectrometry and describe fragmentation routines for surveying the structural properties of the analytes, in particular precursor ion and neutral loss scanning. These allow targeted detection of phospholipid headgroups and identification of phospholipids containing hydroperoxides and chlorine, as well as the detection of some individual oxidation products by their specific fragmentation patterns. We describe instrument protocols for carrying out these survey routines on a QTrap5500 mass spectrometer and also for interfacing with reverse-phase liquid chromatography. The article highlights critical aspects of the analysis as well as some limitations of the methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the accuracy of three wavefront analyzers versus a validated binocular open-view autorefractor in determining refractive error in non-cycloplegic eyes. METHODS: Eighty eyes were examined using the SRW-5000 open-view infrared autorefractor and, in randomized sequence, three wavefront analyzers: 1) OPD-Scan (NIDEK, Gamagori, Japan), 2) WASCA (Zeiss/Meditec, Jena, Germany), and 3) Allegretto (WaveLight Laser Technologies AG, Erlangen, Germany). Subjects were healthy adults (19 men and 21 women; mean age: 20.8 +/- 2.5 years). Refractive errors ranged from +1.5 to -9.75 diopters (D) (mean: +1.83 +/- 2.74 D) with up to 1.75 D cylinder (mean: 0.58 +/- 0.53 D). Three readings were collected per instrument by one examiner without anticholinergic agents. Refraction values were decomposed into vector components for analysis, resulting in mean spherical equivalent refraction (M) and J0 and J45 being vectors of cylindrical power at 0 degrees and 45 degrees, respectively. RESULTS: Positive correlation was observed between wavefront analyzers and the SRW-5000 for spherical equivalent refraction (OPD-Scan, r=0.959, P<.001; WASCA, r=0.981, P<.001; Allegretto, r=0.942, P<.001). Mean differences and limits of agreement showed more negative spherical equivalent refraction with wavefront analyzers (OPD-Scan, 0.406 +/- 0.768 D [range: 0.235 to 0.580 D] [P<.001]; WASCA, 0.511 +/- 0.550 D [range: 0.390 to 0.634 D] [P<.001]; and Allegretto, 0.434 +/- 0.904 D [range: 0.233 to 0.635 D] [P<.001]). A second analysis eliminating outliers showed the same trend but lower differences: OPD-Scan (n=75), 0.24 +/- 0.41 D (range: 0.15 to 0.34 D) (P<.001); WASCA (n=78), 0.46 +/- 0.47 D (range: 0.36 to 0.57 D) (P<.001); and Allegretto (n=77), 0.30 +/- 0.62 D (range: 0.16 to 0.44 D) (P<.001). No statistically significant differences were noted for J0 and J45. CONCLUSIONS: Wavefront analyzer refraction resulted in 0.30 D more myopia compared to SRW-5000 refraction in eyes without cycloplegia. This is the result of the accommodation excess attributable to instrument myopia. For the relatively low degrees of astigmatism in this study (<2.0 D), good agreement was noted between wavefront analyzers and the SRW-5000. Copyright (C) 2006 SLACK Incorporated

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is primarily concerned with the problem of break-squeal in disc brakes, using moulded organic disc pads. Moulded organic friction materials are complex composites and due to this complexity it was thought that they are unlikely to be of uniform composition. Variation in composition would under certain conditions of the braking system, cause slight changes in its vibrational characteristics thus causing resonance in the high audio-frequency range. Dynamic mechanical propertes appear the most likely parameters to be related to a given composition's tendency to promote squeal. Since it was necessary to test under service conditions a review was made of all the available commercial test instruments but as none were suitable it was necessary to design and develop a new instrument. The final instrument design, based on longitudinal resonance, enabled modulus and damping to be determined over a wide range of temperatures and frequencies. This apparatus has commercial value since it is not restricted to friction material testing. Both used and unused pads were tested and although the cause of brake squeal was not definitely established, the results enabled formulation of a tentative theory of the possible conditions for brake squeal. The presence of a temperature of minimum damping was indicated which may be of use to braking design engineers. Some auxilIary testing was also performed to establish the effect of water, oil and brake fluid and also to determine the effect of the various components of friction materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report published in the Proceedings of the National Conference on "Education in the Information Society", Plovdiv, May, 2013