965 resultados para AIR POLLUTION IN MEGACITIES
Resumo:
"EPA Report No. 600/9-86-013"--P. ii.
Resumo:
Bibliography: p. 47-51.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Growing evidence suggest the importance of different environments in promoting the pathogenesis and/or exacerbation of asthma. Indoor air pollution is a major contributor to human exposure, since people spend up to 90% of their day indoors. Apart from active smoking, indoor pollution is considered one of the major preventable risk factors of chronic respiratory diseases. The professional activity can also be dangerous because it exposes the subject to environments that can promote the onset of asthma or worsening of the latter in those already affected. Even bad habits such as incorrect diet, lead to more difficulty in controlling their disease. However asthma is a multifactorial disease in nature so it is not easy to distinguish the role of occupational exposure, pollution and normal habits such as smoking, nutrition, sports, etc. This retrospective study was conducted on a sample of asthma patients residing in the metropolitan area of Parma. 116 patients were selected among those who are followed up at least two years at the Asthma outpatient Clinic of Parma University Hospital. The sample in question is therefore closely controlled and monitored; it comes to patients who are well educated on the control of their disease, are able to take appropriate measures to minimize the symptomatology. With this tight approach is proposed to minimize the effect of confounding and then traced with greater certainty the possible cause of the failure to control the disease. For this purpose, each patient was subjected to regular checkups; we took as a reference the period of time between April and October 2015. During each visit, in addition to general data for each patient, we were collected personal information about their habits and way of life through a validated questionnaire delivered and completed by the patient during the visit in the presence of the permanent staff. The questionnaire covers mainly the qualification of the patient, its possible occupational exposure, his home, with information about nearby traffic, time spent outside, physical activity (place and time), exposure to chemicals, exposure to various fumes (fireplace or stove) and cigarette smoke, comorbidities and any drugs taken during the visits considered. Regarding the respiratory conditions of patients during every examination we were considered: Asthma Control Test (a test performed by patients to assess the state of the disease during the month preceding the test), the measurement of exhaled nitric oxide (FeNO) as an index of airways inflammation, measuring the resistance level of small airways (R5-R20) and some spirometric values observed in experiment; in particular the forced vital capacity (FVC), forced expiratory volume in the first second (FEV 1), FEV1/FVC ratio, forced expiratory flow rate over the middle 50% of the FVC (FEF25–75) and FEF25-75/FVC were recorded. The sample has been studied considering both the changes of the respiratory parameters for every patient in their examinations, and the respiratory parameters of all the examinations took as a whole in relation with the variables considered. From the results obtained, the patients are clinically stable; their adopted lifestyle and the exposure to possible sources of outdoor pollution, seems not affect the overall control of their disease. Some findings of our study are of interest. First, the subjects who carry a steroid therapy show a clinical worst, as revealed by the decrease of most spirometric indices, particularly FEF25, FEF75, FEF25-75 and R5-R20; also, the presence of comorbidities and the subsequent intake of other drugs, in addition to normal therapy for asthma, seem to be conditions associated with poorer performance in the functional respiratory parameters in particular FEV1/FVC, FEF75 and FEF25-75. Spirometric indexes that are down are mainly those related to obstruction imposed on small airways; this suggests a neglect to the latter on the contrary should be further explored and treated accordingly. It is also observed that both patients are overweight than those living on the lower floors and/or who have the most windows exposed to traffic, showed a decrease of pulmonary function, especially those relate to an obstruction at the small airways level. In conclusion, our results provided the evidence that a most appropriate therapy, specific to reach the small airways, associated with a healthy lifestyle, can help improve the management of asthma.
Resumo:
This thesis is concerned with various aspects of Air Pollution due to smell, the impact it has on communities exposed to it, the means by which it may be controlled and the manner in which a local authority may investigate the problems it causes. The approach is a practical one drawing on examples occurring within a Local Authority's experience and for that reason the research is anecdotal and is not a comprehensive treatise on the full range of options available. Odour Pollution is not yet a well organised discipline and might be considered esoteric as it is necessary to incorporate elements of science and the humanities. It has been necessary to range widely across a number of aspects of the subject so that discussion is often restricted but many references have been included to enable a reader to pursue a particular point in greater depth. In a `fuzzy' subject there is often a yawning gap separating theory and practice, thus case studies have been used to illustrate the interplay of various disciplines in resolution of a problem. The essence of any science is observation and measurement. Observation has been made of the spread of odour pollution through a community and also of relevant meterological data so that a mathematical model could be constructed and its predictions checked. It has been used to explore the results of some options for odour control. Measurements of odour perception and human behaviour seldom have the precision and accuracy of the physical sciences. However methods of social research enabled individual perception of odour pollution to be quantified and an insight gained into reaction of a community exposed to it. Odours have four attributes that can be measured and together provide a complete description of its perception. No objective techniques of measurement have yet been developed but in this thesis simple, structured procedures of subjective assessment have been improvised and their use enabled the functioning of the components of an odour control system to be assessed. Such data enabled the action of the system to be communicated using terms that are understood by a non specialist audience.
Resumo:
Automotive catalysts are the most effective short-term answer to air pollution from automobiles. Since strict control of exhaust emissions is, or will be,covered by legislation in most developed countries in the world, catalytic devices will be increasingly fitted to cars. There is consequently an urgent need for the development of catalysts that will not compete for scarce precious metal resources. A number of problems have already been identified in connection with base metal catalysts but quantitative investigations are lacking. The base metal reduction catalysts developed by Imperial Chemical Industries Limited, catalysts and Chemical Group, in collaboration with the Air Pollution Control Laboratory, B L Cars Limited for automotive emission control, are susceptible to de-activation by three major mechanisms. These are: physical loss of the wash-coat (a high surface area coating which supports the active species), aggregation of the active species and poisoning by fuel and engine oil additives. This thesis is especially concerned with the first two of these and attempts to indicate the relative magnitude .of their effect on the activity of. the catalysts. Aggregation of the active species or sintering, as it is loosely called, was studied by using impregnated granules to overcome effects due to the loss of the wash-coat. Samples were aged in a synthetic exhaust gas, free from poisons, and metal crystallite sizes were measured by scanning-electron microscopy. The increase in particle size was correlated with the loss in catalytic activity. In order to maintain a link with the real conditions of service a number of monolithic catalysts were tested in an engine-dynamometer and several previously tested endurance catalysts were examined. A mechanism is proposed for the break-up and subsequent 10s.5 of the wash-coat and suggestions for improved resistance to loss of the' coating and active species are proposed.
Resumo:
Community acceptance has been identified as one of the key requirements for a sustainable bioenergy project. However less attention has been paid to this aspect from developing nations and small projects perspective. Therefore this research examines the role of community acceptance for sustainable small scale bioenergy projects in India. While addressing the aim, this work identifies influence of community over bioenergy projects, major concerns of communities regarding bioenergy projects and factors influencing perceptions of communities about bioenergy projects. The empirical research was carried out on four bioenergy companies in India as case studies. It has been identified that communities have significant influence over bioenergy projects in India. Local air pollution, inappropriate storage of by-products and credibility of developer are identified as some of the important concerns. Local energy needs, benefits to community from bioenergy companies, level of trust on company and relationship between company and the community are some of the prime factors which influence community's perception on bioenergy projects. This research sheds light on important aspects related to community acceptance of bioenergy projects, and this information would help practitioners in understanding the community perceptions and take appropriate actions to satisfy them. © 2014 Elsevier Ltd.
Resumo:
Objectionable odors remain at the top of air pollution complaints in urban areas such as Broward County that is subject to increasing residential and industrial developments. The odor complaints in Broward County escalated by 150 percent for the 2001 to 2004 period although the population increased by only 6 percent. It is estimated that in 2010 the population will increase to 2.5 million. Relying solely on enforcing the local odor ordinance is evidently not sufficient to manage the escalating odor complaint trends. An alternate approach similar to odor management plans (OMPs) that are successful in managing major malodor sources such as animal farms is required. ^ This study aims to develop and determine the feasibility of implementing a comprehensive odor management plan (COMP) for the entire Broward County. Unlike existing OMPs for single sources where the receptors (i.e. the complainants) are located beyond the boundary of the source, the COMP addresses a complex model of multiple sources and receptors coexisting within the boundary of the entire county. Each receptor is potentially subjected to malodor emissions from multiple sources within the county. Also, the quantity and quality of the source/receptor variables are continuously changing. ^ The results of this study show that it is feasible to develop a COMP that adopts a systematic procedure to: (1) Generate maps of existing odor complaint areas and malodor sources, (2) Identify potential odor sources (target sources) responsible for existing odor complaints, (3) Identify possible odor control strategies for target sources, (4) Determine the criteria for implementing odor control strategies, (5) Develop an odor complaint response protocol, and (6) Conduct odor impact analyses for new sources to prevent future odor related issues. Geographic Information System (GIS) is used to identify existing complaint areas. A COMP software that incorporates existing United States Environmental Protection Agency (EPA) air dispersion software is developed to determine the target sources, predict the likelihood of new complaints, and conduct odor impact analysis. The odor response protocol requires pre-planning field investigations and conducting surveys to optimize the local agency available resources while protecting the citizen's welfare, as required by the Clean Air Act. ^
Resumo:
Best management practices in green lodging are sustainable or “green” business strategies designed to enhance the lodging product from the perspective of owners, operators and guests. For guests, these practices should enhance their experience while for owners and operators, generate positive returns on investments. Best management practices in green lodging typically starts with a clear understanding of each lodging firm’s role in society, its impact on the environment and strategies developed to mitigate negative environmental externalities generated from the production of lodging goods and services. Negative externalities of hotel operations manifest themselves in energy and water usage, waste generation and air pollution. Hence, best management practices in green lodging are dynamic, cost effective, innovative, stakeholder driven and environmentally sound technical and behavioral solutions that attempt to ameliorate or eliminate the negative environmental externalities associated with lodging operations, while simultaneously generate positive returns on green investments. Thus, best management practices in green lodging should reduce lodging firms’ operating costs, increase guest satisfaction, reduce or eliminate the negative environmental impacts associated with hotel operations while simultaneously enhance business operations.
Resumo:
Best management practices in green lodging are sustainable or “green” business strategies designed to enhance the lodging product from the perspective of owners, operators and guests. For guests, these practices should enhance their experience while for owners and operators, generate positive returns on investments. Best management practices in green lodging typically starts with a clear understanding of each lodging firm’s role in society, its impact on the environment and strategies developed to mitigate negative environmental externalities generated from the production of lodging goods and services. Negative externalities of hotel operations manifest themselves in energy and water usage, waste generation and air pollution. Hence, best management practices in green lodging are dynamic, cost effective, innovative, stakeholder driven and environmentally sound technical and behavioral solutions that attempt to ameliorate or eliminate the negative environmental externalities associated with lodging operations, while simultaneously generate positive returns on green investments. Thus, best management practices in green lodging should reduce lodging firms’ operating costs, increase guest satisfaction, reduce or eliminate the negative environmental impacts associated with hotel operations while simultaneously enhance business operations.
Resumo:
We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 +/- 0.7 (stat) +/- 6.7 (syst) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.
Resumo:
As part of the EUCAARI Intensive Observing Period, a 4-week campaign to measure aerosol physical, chemical and optical properties, atmospheric structure, and cloud microphysics was conducted from mid-May to mid-June, 2008 at the Mace Head Atmospheric Research Station, located at the interface of Western Europe and the N. E. Atlantic and centered on the west Irish coastline. During the campaign, continental air masses comprising both young and aged continental plumes were encountered, along with polar, Arctic and tropical air masses. Polluted-continental aerosol concentrations were of the order of 3000 cm(-3), while background marine air aerosol concentrations were between 400-600 cm(-3). The highest marine air concentrations occurred in polar air masses in which a 15 nm nucleation mode, with concentration of 1100 cm(-3), was observed and attributed to open ocean particle formation. Continental air submicron chemical composition (excluding refractory sea salt) was dominated by organic matter, closely followed by sulphate mass. Although the concentrations and size distribution spectral shape were almost identical for the young and aged continental cases, hygroscopic growth factors (GF) and cloud condensation nuclei (CCN) to total condensation nuclei (CN) concentration ratios were significantly less in the younger pollution plume, indicating a more oxidized organic component to the aged continental plume. The difference in chemical composition and hygroscopic growth factor appear to result in a 40-50% impact on aerosol scattering coefficients and Aerosol Optical Depth, despite almost identical aerosol microphysical properties in both cases, with the higher values been recorded for the more aged case. For the CCN/CN ratio, the highest ratios were seen in the more age plume. In marine air, sulphate mass dominated the sub-micron component, followed by water soluble organic carbon, which, in turn, was dominated by methanesulphonic acid (MSA). Sulphate concentrations were highest in marine tropical air - even higher than in continental air. MSA was present at twice the concentrations of previously-reported concentrations at the same location and the same season. Both continental and marine air exhibited aerosol GFs significantly less than ammonium sulphate aerosol pointing to a significant organic contribution to all air mass aerosol properties.
Resumo:
In developing countries, access to modern energy for cooking and heating still remains a challenge to raising households out of poverty. About 2.5 billion people depend on solid fuels such as biomass, wood, charcoal and animal dung. The use of solid fuels has negative outcomes for health, the environment and economic development (Universal Energy Access, UNDP). In low income countries, 1.3 million deaths occur due to indoor smoke or air pollution from burning solid fuels in small, confined and unventilated kitchens or homes. In addition, pollutants such as black carbon, methane and ozone, emitted when burning inefficient fuels, are responsible for a fraction of the climate change and air pollution. There are international efforts to promote the use of clean cookstoves in developing countries but limited evidence on the economic benefits of such distribution programs. This study undertook a systematic economic evaluation of a program that distributed subsidized improved cookstoves to rural households in India. The evaluation examined the effect of different levels of subsidies on the net benefits to the household and to society. This paper answers the question, “Ex post, what are the economic benefits to various stakeholders of a program that distributed subsidized improved cookstoves?” In addressing this question, the evaluation used empirical data from India applied to a cost-benefit model to examine how subsidies affect the costs and the benefits of the biomass improved cookstove and the electric improved cookstove to different stakeholders.
Resumo:
The air trapped in freshly formed ice gives information concerning the ice formation processes as weH as concerning severa,l environmental parameters at the time of ice formation. Air arnount, air composition, and the size and form of bubbles may change with time. Possible processes responsible for such changes are discussed. In very cold ice air content and air composition remain almost unchanged. Samples of ancient atmospheric air are therefore very weH preserved in cold ice. In temperate ice changes of the air amount and air composition depend on the intergranular water fiow through the glacier. This waterfiow can be estimated by measuring air amount and air composition in ice sampIes.
Resumo:
Natural ice is formed by freezing of water or by sintering of dry or wet snow. Each of these processes causes atmospheric air to be enclosed in ice as bubbles. The air amount and composition as well as the bubble sizes and density depend not only on the kind of process but also on several environmental conditions. The ice in the deepest layers of the Greenland and thc Antarctic ice sheet was formed more than 100 000 years ago. In the bubbles of this ice, samples of atmospheric air from that time are preserved. The enclosure of air is discussed for each of the three processes. Of special interest are the parameters which control the amount and composition of the enclosed air. If the ice is formed by sintering of very cold dry snow, the air composition in the bubbles corresponds with good accuracy to the composition of atmospheric air.