971 resultados para 030100 ANALYTICAL CHEMISTRY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since the introduction of the European ban on hormones in 1989, its implementation has proved to be an enormous challenge to regulatory authorities, because the great economic benefits that result from illegal misuse of growth promoters in animal production encourage their continued use. In efforts to challenge black-market trade in hormones, there have been many analytical advances. Recently, both effect-based bioanalysis for screening to target illegal misuse and improved mass-spectrometry-based confirmatory analysis have greatly increased the likelihood of detecting hormone abuse. This review outlines analytical methods currently used for detecting hormone abuse and presents advances in new approaches based on biological determinants that may complement these techniques in the future. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Growth-promoting agents are illicitly used during animal rearing processes and the detection of their use is limited by new compounds and dosing practices that limit the efficiency of current testing which is based on residue analysis by liquid chromatography–tandem mass spectrometry (LC–MS/MS) and gas chromatography–mass spectrometry (GC–MS) methodology. An alternative approach is to use indirect biological evidence as a screening tool to identify growth-promoter treated animals thus improving the effectiveness of residue testing through the targeted sampling of these animals. Sex hormone-binding globulin (SHBG) is a glycoprotein which binds and controls the levels of sex-hormones within the circulation. Using a biosensor assay based on measurement of binding to an immobilised 1a-dihydrotestosterone (1a-DHT) derivative, reduced SHBG binding capacities were detected in growth-promoter treated animals. During the course of a veal treatment regime based on repeated oestradiol benzoate, nortestosterone decanoate and dexamethasone administrations, treated male and female calves were shown to have significantly lower SHBG capacities. To assess the effectiveness of using SHBG binding capacities as a biomarker of treatment and to investigate the role of individual growth-promoter components to the SHBG capacity lowering effects, adult heifer animals were subjected to repeated doses of nortestosterone decanoate. These animals also demonstrated a reduction in SHBG capacity levels at Day 39 of the study, in contrast to oestradiol benzoate treated adult steers who were found to have unaltered levels. These findings suggest that the measurement of SHBG binding capacities using a biosensor assay has potential in the identification of illegally treated animals, particularly those exposed to androgens.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

C17 polyacetylenes are a group of bioactive compounds present in carrots which have recently gained scientific attention due to their cytotoxicity against cancer cells. In common with many bioactive compounds, their levels may be influenced by thermal processes, such as boiling or water immersion. This study investigated the effect of a number of water immersion time/temperature combinations on concentrations of these compounds and attempted to model the changes. Carrot samples were thermally treated by heating in water at temperatures from 50–100 °C and holding times of 2–60 min. Following heating, levels of falcarinol (FaOH), falcarindiol (FaDOH), falcarindiol-3-acetate (FaDOAc) and Hunter colour parameters (L*a*b*) were determined. FaOH, FaDOH, FaDOAc levels were significantly reduced at lower temperatures (50–60 °C). In contrast, samples heated at temperatures from 70–100 °C exhibited higher levels of polyacetylenes (p < 0.05) than did raw unprocessed samples. Regression modelling was used to model the effects of temperature and holding time on the levels of the variables measured. Temperature treatment and holding time were found to significantly affect the polyacetylene content of carrot disks. Predicted models were found to be significant (p < 0.05) with high coefficients of determination (R2).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We review the design and fabrication of thin-film composite optical waveguides (OWG) with high refractive index for sensor applications. A highly sensitive optical sensor device has been developed on the basis of thin-film, composite OWG. The thin-film OWG was deposited onto the surface of a potassium-ion-exchanged (K+) glass OWG by sputtering or spin coating (5-9 mm wide, and with tapers at both ends). By allowing an adiabatic transition of the guided light from the secondary OWG to the thin-film OWG, the electric field of the evanescent wave at the thin film was enhanced. The attenuation of the guided light in the thin film layer was small, and the guided light intensity changed sensitively with the refractive index of the cladding layer. Our experimental results demonstrate that thin-film, composite OWG gas sensors or immunosensors are much more sensitive than sensors based on other technologies. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increasing availability and use of sports supplements is of concern as highlighted by a number of studies reporting endocrine disruptor contamination in such products. The health food supplement market, including sport supplements, is growing across the Developed World. Therefore, the need to ensure the quality and safety of sport supplements for the consumer is essential. The development and validation of two reporter gene assays coupled with solid phase sample preparation enabling the detection of estrogenic and androgenic constituents in sport supplements is reported. Both assays were shown to be of high sensitivity with the estrogen and androgen reporter gene assays having an EC50 of 0.01 ng mL-1 and 0.16 ng mL-1 respectively. The developed assays were applied in a survey of 63 sport supplements samples obtained across the Island of Ireland with an additional seven reference samples previously investigated using LC–MS/MS. Androgen and estrogen bio-activity was found in 71% of the investigated samples. Bio-activity profiling was further broken down into agonists, partial agonists and antagonists. Supplements (13) with the strongest estrogenic bio-activity were chosen for further investigation. LC–MS/MS analysis of these samples determined the presence of phytoestrogens in seven of them. Supplements (38) with androgen bio-activity were also selected for further investigation. Androgen agonist bio-activity was detected in 12 supplements, antagonistic bio-activity was detected in 16 and partial antagonistic bio-activity was detected in 10. A further group of supplements (7) did not present androgenic bio-activity when tested alone but enhanced the androgenic agonist bio-activity of dihydrotestosterone when combined. The developed assays offer advantages in detection of known, unknown and low-level mixtures of endocrine disruptors over existing analytical screening techniques. For the detection and identification of constituent hormonally active compounds the combination of biological and physio-chemical techniques is optimal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Time of flight (ToF) mass spectrometer suitable in terms of sensitivity, detector response and time resolution, for application in fast transient Temporal Analysis of Products (TAP) kinetic catalyst characterization is reported. Technical difficulties associated with such application as well as the solutions implemented in terms of adaptations of the ToF apparatus are discussed. The performance of the ToF was validated and the full linearity of the specific detector over the full dynamic range was explored in order to ensure its applicability for the TAP application. The reported TAP-ToF setup is the first system that achieves the high level of sensitivity allowing monitoring of the full 0-200 AMU range simultaneously with sub-millisecond time resolution. In this new setup, the high sensitivity allows the use of low intensity pulses ensuring that transport through the reactor occurs in the Knudsen diffusion regime and that the data can, therefore, be fully analysed using the reported theoretical TAP models and data processing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we define the structural information content of graphs as their corresponding graph entropy. This definition is based on local vertex functionals obtained by calculating-spheres via the algorithm of Dijkstra. We prove that the graph entropy and, hence, the local vertex functionals can be computed with polynomial time complexity enabling the application of our measure for large graphs. In this paper we present numerical results for the graph entropy of chemical graphs and discuss resulting properties. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An enzyme labeled immunosorbent assay (ELISA) and surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins were developed and a comparative evaluation was performed. A polyclonal antibody (BC67) used in both assay formats was raised to saxitoxin–jeffamine–BSA in New Zealand white rabbits. Each assay format was designed as an inhibition assay. Shellfish samples (n = 54) were evaluated by each method using two simple rapid extraction procedures and compared to the AOAC high performance liquid chromatography (HPLC) and the mouse bioassay (MBA). The results of each assay format were comparable with the HPLC and MBA methods and demonstrate that an antibody with high sensitivity and broad specificity to PSP toxins can be applied to different immunological techniques. The method of choice will depend on the end-users needs. The reduced manual labor and simplicity of operation of the SPR biosensor compared to ELISA, ease of sample extraction and superior real time semi-quantitative analysis are key features that could make this technology applicable in a high-throughput monitoring unit.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new stir bar sorptive extraction (SBSE) technique coupled with HPLC-UV method for quantification of diclofenac in pharmaceutical formulations has been developed and validated as a proof of concept study. Commercially available polydimethylsiloxane stir bars (Twister (TM)) were used for method development and SBSE extraction (pH, phase ratio, stirring speed, temperature, ionic strength and time) and liquid desorption (solvents, desorption method, stirring time etc) procedures were optimised. The method was validated as per ICH guidelines and was successfully applied for the estimation of diclofenac from three liquid formulations viz. Voltarol (R) Optha single dose eye drops, Voltarol (R) Ophtha multidose eye drops and Voltarol (R) ampoules. The developed method was found to be linear (r=0.9999) over 100-2000 ng/ml concentration range with acceptable accuracy and precision (tested over three QC concentrations). The SBSE extraction recovery of the diclofenac was found to be 70% and the LOD and LOQ of the validated method were found to be 16.06 and 48.68 ng/ml, respectively. Furthermore, a forced degradation study of a diclofenac formulation leading to the formation of structurally similar cyclic impurity (indolinone) was carried out. The developed extraction method showed comparable results to that of the reference method, i.e. method was capable of selectively extracting the indolinone and diclofenac from the liquid matrix. Data on inter and intra stir bar accuracy and precision further confirmed robustness of the method, supporting the multiple re-use of the stir bars. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The need for chemical and biological entities of predetermined selectivity and affinity towards target analytes is greater than ever, in applications such as environmental monitoring, bioterrorism detection and analysis of natural toxin contaminants in the food chain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biosensors are used for a large number of applications within biotechnology, including the pharmaceutical industry and life sciences. Since the production of Biacore surface-plasmon resonance instruments in the early 1990s, there has been steadily growing use of this technology for the detection of food contaminants (e.g., veterinary drugs, mycotoxins, marine toxins, food dyes and processing contaminants). Other biosensing technologies (e.g., electrochemical and piezoelectric) have also been employed for the analysis of small-molecule contaminants. This review concentrates on recent advances made in detection and quantification of antimicrobial compounds with different types of biosensors and on the emergence of multiplexing, which is highly desirable as it increases sample analysis at lower cost and in less time. (C) 2010 Elsevier Ltd. All rights reserved.