970 resultados para weld improvement method
Resumo:
In this study, we sought to assess the applicability of GC–MS/MS for the identification and quantification of 36 pesticides in strawberry from integrated pest management (IPM) and organic farming (OF). Citrate versions of QuEChERS (quick, easy, cheap, effective, rugged and safe) using dispersive solid-phase extraction (d-SPE) and disposable pipette extraction (DPX) for cleanup were compared for pesticide extraction. For cleanup, a combination of MgSO4, primary secondary amine and C18 was used for both the versions. Significant differences were observed in recovery results between the two sample preparation versions (DPX and d-SPE). Overall, 86% of the pesticides achieved recoveries (three spiking levels 10, 50 and 200 µg/kg) in the range of 70–120%, with <13% RSD. The matrix effects were also evaluated in both the versions and in strawberries from different crop types. Although not evidencing significant differences between the two methodologies were observed, however, the DPX cleanup proved to be a faster technique and easy to execute. The results indicate that QuEChERS with d-SPE and DPX and GC–MS/MS analysis achieved reliable quantification and identification of 36 pesticide residues in strawberries from OF and IPM.
Resumo:
i Gestão de Operações de um armazém Patrícia Raquel Freitas Gomes Relatório de estágio apresentado ao Instituto Superior de Contabilidade e Administração do Porto para obtenção de Grau de Mestre em Logística Orientado por: Prof. Doutora Maria Teresa Ribeiro Pereira Coorientado por: Eng.º César Emanuel Marinho Carvalho Teixeira
Resumo:
A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.
Resumo:
Dissertation submitted to Faculdade de Ciências e Tecnologia - Universidade Nova de Lisboa in fulfilment of the requirements for the degree of Doctor of Philosophy (Biochemistry - Biotechnology)
Resumo:
O presente trabalho visa a redução do tempo de mudança de produção e consequente aumento de produtividade de uma linha de envernizamento/pintura integrada na empresa Amorim Revestimentos SA, unidade S. Paio de Oleiros, que se dedica à produção de pisos flutuantes. Esta necessidade surgiu pelo facto desta linha de produção ser um ponto de estrangulamento do processo produtivo no departamento em que está inserida, devido principalmente à diminuição do tamanho de lotes e aumento da variedade de artigos a produzir. O trabalho envolveu as várias etapas da ferramenta SMED às quais está inerente a aplicação da técnica 5S às máquinas e ferramentas garantindo, assim, o posto de trabalho arrumado, limpo, seguro e com tudo pronto a ser utilizado. Aplicou-se a ferramenta SMED a dois tipos de mudança de acabamento e à mudança de rolo de pintura. Após a implementação desta ferramenta verificou-se uma redução de tempos de 37% (48 para 30 minutos) na mudança de pintura e acabamento de verniz, reduziu-se 25% (32 para 24 minutos) na mudança só de pintura e 13% (46 para 40 minutos) na mudança de rolo de pintura. Estes resultados foram alcançados através da redução do tempo das tarefas externas e internas e transformação das tarefas internas em externas consequentes da aplicação de um conjunto de ações de melhorias. Também foi fundamental a alteração do método de trabalho e a organização geral do posto de trabalho, no que diz respeito à repartição equilibrada das tarefas pelos dois operadores, alteração do sequenciamento das tarefas e aplicação da técnica 5S. As soluções encontradas estão sendo monitorizadas através do registo efectuado pelos operadores e realização de auditorias internas para garantir a perpetuação dos resultados.
Resumo:
Dissertação apresentada ao Instituto Superior de Administração e Contabilidade do Porto para obtenção do Grau de Mestre em Logística Orientada por: Professora Doutora Maria Clara Rodrigues Bento Vaz Fernandes
Resumo:
As the wireless cellular market reaches competitive levels never seen before, network operators need to focus on maintaining Quality of Service (QoS) a main priority if they wish to attract new subscribers while keeping existing customers satisfied. Speech Quality as perceived by the end user is one major example of a characteristic in constant need of maintenance and improvement. It is in this topic that this Master Thesis project fits in. Making use of an intrusive method of speech quality evaluation, as a means to further study and characterize the performance of speech codecs in second-generation (2G) and third-generation (3G) technologies. Trying to find further correlation between codecs with similar bit rates, along with the exploration of certain transmission parameters which may aid in the assessment of speech quality. Due to some limitations concerning the audio analyzer equipment that was to be employed, a different system for recording the test samples was sought out. Although the new designed system is not standard, after extensive testing and optimization of the system's parameters, final results were found reliable and satisfactory. Tests include a set of high and low bit rate codecs for both 2G and 3G, where values were compared and analysed, leading to the outcome that 3G speech codecs perform better, under the approximately same conditions, when compared with 2G. Reinforcing the idea that 3G is, with no doubt, the best choice if the costumer looks for the best possible listening speech quality. Regarding the transmission parameters chosen for the experiment, the Receiver Quality (RxQual) and Received Energy per Chip to the Power Density Ratio (Ec/N0), these were subject to speech quality correlation tests. Final results of RxQual were compared to those of prior studies from different researchers and, are considered to be of important relevance. Leading to the confirmation of RxQual as a reliable indicator of speech quality. As for Ec/N0, it is not possible to state it as a speech quality indicator however, it shows clear thresholds for which the MOS values decrease significantly. The studied transmission parameters show that they can be used not only for network management purposes but, at the same time, give an expected idea to the communications engineer (or technician) of the end-to-end speech quality consequences. With the conclusion of the work new ideas for future studies come to mind. Considering that the fourth-generation (4G) cellular technologies are now beginning to take an important place in the global market, as the first all-IP network structure, it seems of great relevance that 4G speech quality should be subject of evaluation. Comparing it to 3G, not only in narrowband but also adding wideband scenarios with the most recent standard objective method of speech quality assessment, POLQA. Also, new data found on Ec/N0 tests, justifies further research studies with the intention of validating the assumptions made in this work.
Resumo:
Faeces of 138 chickens were inoculated on Blaser agar plates. One set of plates was incubated in jars with CampyPak envelopes. The others were incubated in "Zip-lock" plastic bags (7 x X in.) and a microaerophilic atmosphere was generated exhaling into the "Zip-lock" plastic bag, after holding the breath for 20 sec. Then, the bag was pressed to evacuate its atmosphere, inflated again, and pressed (4 times), and finally sealed. Campylobacter was isolated from 127 (96.2%) of samples incubated in jars with gas generator envelopes and from 129 (98%) of the specimens incubated into the bags. The proposed methodology offers good savings for cost-conscious laboratories.
Resumo:
Prevalence of Strongyloides stercoralis infection in three areas of Brazil was surveyed by a recently developed faecal culture method (an agar plate culture). The Strongyloides infection was confirmed in 11.3% of 432 subjects examined. The diagnostic efficacy of the agar plate culture was as high as 93.9% compared to only 28.5% and 26.5% by the Harada-Mori filter paper culture and faecal concentration methods, when faecal samples were examined simultaneously by these three methods. Among the 49 positive samples, about 60% were confirmed to be positive only by the agar plate culture. These results indicate that the agar plate culture is a sensitive new tool for the correct diagnosis of chronic Strongyloides infection.
Resumo:
A single and practical method to slain Malassezia furfur and Corynebacterium minutissimum in lesions' scales is described. The scales are collected by pressing small pieces of scotch tape (about 4 cm lenght and 2 cm width) onto the lesions and following withdrawl the furfuraceous scales will remain on the glue side. These pieces are then immersed for some minutes in lactophenol-cotton blue stain. Following absorption of the stain the scales are washed in current water to remove the excess of blue stain, dried with filter paper, dehydrated via passage in two bottles containing absolute alcohol and then placed in xylene in a centrifugation tube. The xylene dissolves the scotch tape glue and the scales fall free in the tube. After centrifugation and decantation the scales concentrated on the bottom of the tube are collected with a platinum-loop, placed in Canada balsam on a microscopy slide and closed with a cover slip. The preparations are then ready to be submitted to microscopic examination. Other stains may also be used instead of lactophenol-cotton blue. This method is simple, easily performed, and offers good conditions to study these fungi as well as being useful for the diagnosis of the diseases that they cause.
Resumo:
Sustainable Construction, Materials and Practice, p. 426-432
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination
Resumo:
Nos últimos anos a indústria de semicondutores, nomeadamente a produção de memórias, tem sofrido uma grande evolução. A necessidade de baixar custos de produção, assim como de produzir sistemas mais complexos e com maior capacidade, levou à criação da tecnologia WLP (Wafer Level Packaging). Esta tecnologia permite a produção de sistemas mais pequenos, simplificar o fluxo do processo e providenciar uma redução significativa do custo final do produto. A WLP é uma tecnologia de encapsulamento de circuitos integrados quando ainda fazem parte de wafers (bolachas de silício), em contraste com o método tradicional em que os sistemas são individualizados previamente antes de serem encapsulados. Com o desenvolvimento desta tecnologia, surgiu a necessidade de melhor compreender o comportamento mecânico do mold compound (MC - polímero encapsulante) mais especificamente do warpage (empeno) de wafers moldadas. O warpage é uma característica deste produto e deve-se à diferença do coeficiente de expansão térmica entre o silício e o mold compound. Este problema é observável no produto através do arqueamento das wafers moldadas. O warpage de wafers moldadas tem grande impacto na manufatura. Dependendo da quantidade e orientação do warpage, o transporte, manipulação, bem como, a processamento das wafers podem tornar-se complicados ou mesmo impossíveis, o que se traduz numa redução de volume de produção e diminuição da qualidade do produto. Esta dissertação foi desenvolvida na Nanium S.A., empresa portuguesa líder mundial na tecnologia de WLP em wafers de 300mm e aborda a utilização da metodologia Taguchi, no estudo da variabilidade do processo de debond para o produto X. A escolha do processo e produto baseou-se numa análise estatística da variação e do impacto do warpage ao longo doprocesso produtivo. A metodologia Taguchi é uma metodologia de controlo de qualidade e permite uma aproximação sistemática num dado processo, combinando gráficos de controlo, controlo do processo/produto, e desenho do processo para alcançar um processo robusto. Os resultados deste método e a sua correta implementação permitem obter poupanças significativas nos processos com um impacto financeiro significativo. A realização deste projeto permitiu estudar e quantificar o warpage ao longo da linha de produção e minorar o impacto desta característica no processo de debond. Este projecto permitiu ainda a discussão e o alinhamento entre as diferentes áreas de produção no que toca ao controlo e a melhoria de processos. Conseguiu–se demonstrar que o método Taguchi é um método eficiente no que toca ao estudo da variabilidade de um processo e otimização de parâmetros. A sua aplicação ao processo de debond permitiu melhorar ou a fiabilidade do processo em termos de garantia da qualidade do produto, como ao nível do aumento de produção.