955 resultados para text user interface


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 mu g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO2 into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO2 can be provided in four different ways to the versatile gas interface. As a primary method. CO2 is delivered in glass or quartz ampoules. In this case, the CO2 is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO2 is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO2 is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Software for use with patient records is challenging to design and difficult to evaluate because of the tremendous variability of patient circumstances. A method was devised by the authors to overcome a number of difficulties. The method evaluates and compares objectively various software products for use in emergency departments and compares software to conventional methods like dictation and templated chart forms. The technique utilizes oral case simulation and video recording for analysis. The methodology and experiences of executing a study using this case simulation are discussed in this presentation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces an extended hierarchical task analysis (HTA) methodology devised to evaluate and compare user interfaces on volumetric infusion pumps. The pumps were studied along the dimensions of overall usability and propensity for generating human error. With HTA as our framework, we analyzed six pumps on a variety of common tasks using Norman’s Action theory. The introduced method of evaluation divides the problem space between the external world of the device interface and the user’s internal cognitive world, allowing for predictions of potential user errors at the human-device level. In this paper, one detailed analysis is provided as an example, comparing two different pumps on two separate tasks. The results demonstrate the inherent variation, often the cause of usage errors, found with infusion pumps being used in hospitals today. The reported methodology is a useful tool for evaluating human performance and predicting potential user errors with infusion pumps and other simple medical devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GuideView is a system designed for structured, multi-modal delivery of clinical guidelines. Clinical instructions are presented simultaneously in voice, text, pictures or video or animations. Users navigate using mouse-clicks and voice commands. An evaluation study performed at a medical simulation laboratory found that voice and video instructions were rated highly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Interruptions are known to have a negative impact on activity performance. Understanding how an interruption contributes to human error is limited because there is not a standard method for analyzing and classifying interruptions. Qualitative data are typically analyzed by either a deductive or an inductive method. Both methods have limitations. In this paper, a hybrid method was developed that integrates deductive and inductive methods for the categorization of activities and interruptions recorded during an ethnographic study of physicians and registered nurses in a Level One Trauma Center. Understanding the effects of interruptions is important for designing and evaluating informatics tools in particular as well as improving healthcare quality and patient safety in general. METHOD: The hybrid method was developed using a deductive a priori classification framework with the provision of adding new categories discovered inductively in the data. The inductive process utilized line-by-line coding and constant comparison as stated in Grounded Theory. RESULTS: The categories of activities and interruptions were organized into a three-tiered hierarchy of activity. Validity and reliability of the categories were tested by categorizing a medical error case external to the study. No new categories of interruptions were identified during analysis of the medical error case. CONCLUSIONS: Findings from this study provide evidence that the hybrid model of categorization is more complete than either a deductive or an inductive method alone. The hybrid method developed in this study provides the methodical support for understanding, analyzing, and managing interruptions and workflow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

People often use tools to search for information. In order to improve the quality of an information search, it is important to understand how internal information, which is stored in user’s mind, and external information, represented by the interface of tools interact with each other. How information is distributed between internal and external representations significantly affects information search performance. However, few studies have examined the relationship between types of interface and types of search task in the context of information search. For a distributed information search task, how data are distributed, represented, and formatted significantly affects the user search performance in terms of response time and accuracy. Guided by UFuRT (User, Function, Representation, Task), a human-centered process, I propose a search model, task taxonomy. The model defines its relationship with other existing information models. The taxonomy clarifies the legitimate operations for each type of search task of relation data. Based on the model and taxonomy, I have also developed prototypes of interface for the search tasks of relational data. These prototypes were used for experiments. The experiments described in this study are of a within-subject design with a sample of 24 participants recruited from the graduate schools located in the Texas Medical Center. Participants performed one-dimensional nominal search tasks over nominal, ordinal, and ratio displays, and searched one-dimensional nominal, ordinal, interval, and ratio tasks over table and graph displays. Participants also performed the same task and display combination for twodimensional searches. Distributed cognition theory has been adopted as a theoretical framework for analyzing and predicting the search performance of relational data. It has been shown that the representation dimensions and data scales, as well as the search task types, are main factors in determining search efficiency and effectiveness. In particular, the more external representations used, the better search task performance, and the results suggest the ideal search performance occurs when the question type and corresponding data scale representation match. The implications of the study lie in contributing to the effective design of search interface for relational data, especially laboratory results, which are often used in healthcare activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present the Cellular Dynamic Simulator (CDS) for simulating diffusion and chemical reactions within crowded molecular environments. CDS is based on a novel event driven algorithm specifically designed for precise calculation of the timing of collisions, reactions and other events for each individual molecule in the environment. Generic mesh based compartments allow the creation / importation of very simple or detailed cellular structures that exist in a 3D environment. Multiple levels of compartments and static obstacles can be used to create a dense environment to mimic cellular boundaries and the intracellular space. The CDS algorithm takes into account volume exclusion and molecular crowding that may impact signaling cascades in small sub-cellular compartments such as dendritic spines. With the CDS, we can simulate simple enzyme reactions; aggregation, channel transport, as well as highly complicated chemical reaction networks of both freely diffusing and membrane bound multi-protein complexes. Components of the CDS are generally defined such that the simulator can be applied to a wide range of environments in terms of scale and level of detail. Through an initialization GUI, a simple simulation environment can be created and populated within minutes yet is powerful enough to design complex 3D cellular architecture. The initialization tool allows visual confirmation of the environment construction prior to execution by the simulator. This paper describes the CDS algorithm, design implementation, and provides an overview of the types of features available and the utility of those features are highlighted in demonstrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical text understanding (CTU) is of interest to health informatics because critical clinical information frequently represented as unconstrained text in electronic health records are extensively used by human experts to guide clinical practice, decision making, and to document delivery of care, but are largely unusable by information systems for queries and computations. Recent initiatives advocating for translational research call for generation of technologies that can integrate structured clinical data with unstructured data, provide a unified interface to all data, and contextualize clinical information for reuse in multidisciplinary and collaborative environment envisioned by CTSA program. This implies that technologies for the processing and interpretation of clinical text should be evaluated not only in terms of their validity and reliability in their intended environment, but also in light of their interoperability, and ability to support information integration and contextualization in a distributed and dynamic environment. This vision adds a new layer of information representation requirements that needs to be accounted for when conceptualizing implementation or acquisition of clinical text processing tools and technologies for multidisciplinary research. On the other hand, electronic health records frequently contain unconstrained clinical text with high variability in use of terms and documentation practices, and without commitmentto grammatical or syntactic structure of the language (e.g. Triage notes, physician and nurse notes, chief complaints, etc). This hinders performance of natural language processing technologies which typically rely heavily on the syntax of language and grammatical structure of the text. This document introduces our method to transform unconstrained clinical text found in electronic health information systems to a formal (computationally understandable) representation that is suitable for querying, integration, contextualization and reuse, and is resilient to the grammatical and syntactic irregularities of the clinical text. We present our design rationale, method, and results of evaluation in processing chief complaints and triage notes from 8 different emergency departments in Houston Texas. At the end, we will discuss significance of our contribution in enabling use of clinical text in a practical bio-surveillance setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Se presenta el proyecto de investigación aprobado y subsidiado en el marco de la Programación Científica UBACYT 2011-2014 sobre la problemática de las interfaces de usuario de los catálogos en línea de acceso público (OPACs) en entorno web de las bibliotecas nacionales, universitarias, especializadas y públicas de Latinoamérica, a fin de examinar las funcionalidades propias de las áreas de control de operaciones, formulación de la búsqueda y puntos de acceso, control de salida y asistencia al usuario, así como también las funcionalidades Web 2.0. Se adopta una metodología cuantitativa. Se plantea aplicar a una muestra representada por 102 unidades, extraída por muestreo aleatorio simple (de una población compuesta por 846 casos), la lista de funcionalidades que proporciona Hildreth (1982) actualizada; comparar, mediante un diseño experimental de muestras relacionadas, las variaciones producidas en cuanto a presencia/ausencia de funcionalidades y tipo de software adoptado en relación con la situación existente ya verificada en investigaciones previas; identificar, a partir de la observación de las interfaces de los OPACs que constituyen la muestra, la presencia/ausencia de funcionalidades Web 2.0; utilizar para ello como instrumento de recolección la lista de funcionalidades deseables en los OPACs 2.0 confeccionada por Margaix-Arnal (2007); aplicar diferentes pruebas estadísticas para describir las características de la interface de usuario de los OPACs Web de la región a partir del supuesto de que ha aumentado el uso de Sistemas Integrados de Gestión Bibliotecaria y la presencia de funcionalidades en aquellas unidades que han adoptado estos sistemas, aunque carecen aún de funcionalidades 2.0.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Se presenta el proyecto de investigación aprobado y subsidiado en el marco de la Programación Científica UBACYT 2011-2014 sobre la problemática de las interfaces de usuario de los catálogos en línea de acceso público (OPACs) en entorno web de las bibliotecas nacionales, universitarias, especializadas y públicas de Latinoamérica, a fin de examinar las funcionalidades propias de las áreas de control de operaciones, formulación de la búsqueda y puntos de acceso, control de salida y asistencia al usuario, así como también las funcionalidades Web 2.0. Se adopta una metodología cuantitativa. Se plantea aplicar a una muestra representada por 102 unidades, extraída por muestreo aleatorio simple (de una población compuesta por 846 casos), la lista de funcionalidades que proporciona Hildreth (1982) actualizada; comparar, mediante un diseño experimental de muestras relacionadas, las variaciones producidas en cuanto a presencia/ausencia de funcionalidades y tipo de software adoptado en relación con la situación existente ya verificada en investigaciones previas; identificar, a partir de la observación de las interfaces de los OPACs que constituyen la muestra, la presencia/ausencia de funcionalidades Web 2.0; utilizar para ello como instrumento de recolección la lista de funcionalidades deseables en los OPACs 2.0 confeccionada por Margaix-Arnal (2007); aplicar diferentes pruebas estadísticas para describir las características de la interface de usuario de los OPACs Web de la región a partir del supuesto de que ha aumentado el uso de Sistemas Integrados de Gestión Bibliotecaria y la presencia de funcionalidades en aquellas unidades que han adoptado estos sistemas, aunque carecen aún de funcionalidades 2.0.