985 resultados para testing platform
Resumo:
A pair of blades were constructed following a Tapered Chord, Zero Twist pattern after Anderson. The construction uses the Wood Epoxy Saturation Technique, with a solid Beech main spar and leading edge joined together with laminated veneers of beech forming a D-section; the trailing edge is formed from millimetre ply skins, foam filled to resist compressive loads. This construction leads to an extremely light, flexible blade, with the centres of gravity and torsion well forward, giving good stability. Each blade has three built-in strain gauges, alowing flapwise bending to be measured. Stiffness, and natural frequencies, were measured, to input to a numerical computer model to calculate blade deformation during operation, and to determine stability boundaries of the blade. Preliminary aerodynamic performance measurements are presented and close agreement is found with theory.
Resumo:
Previously published expressions for the wear volume in the micro-scale abrasion test for curved specimen surfaces (K.L. Rutherford and I.M. Hutchings, Tribology Letters 2 (1996) 1-11) were based upon erroneous assumptions about the wear-scar geometry. Accurate volumes have now been computed, and the errors in the use of the original analytical equations are shown to be negligibly small (<0.5% error) for all practical cases. © J.C. Baltzer AG, Science Publishers.
Smart chemical sensor application of ZnO nanowires grown on CMOS compatible SOI microheater platform
Resumo:
Smart chemical sensor based on CMOS(complementary metal-oxide- semiconductor) compatible SOI(silicon on insulator) microheater platform was realized by facilitating ZnO nanowires growth on the small membrane at the relatively low temperature. Our SOI microheater platform can be operated at the very low power consumption with novel metal oxide sensing materials, like ZnO or SnO2 nanostructured materials which demand relatively high sensing temperature. In addition, our sol-gel growth method of ZnO nanowires on the SOI membrane was found to be very effective compared with ink-jetting or CVD growth techniques. These combined techniques give us the possibility of smart chemical sensor technology easily merged into the conventional semiconductor IC application. The physical properties of ZnO nanowire network grown by the solution-based method and its chemical sensing property also were reported in this paper.
Resumo:
An investigation into the seismic behaviour of municipal solid waste (MSW) landfills by dynamic centrifuge testing was undertaken. This paper presents physical modelling of MSW landfills for dynamic centrifuge testing, with regard to the following research areas: 1. amplification characteristics of municipal solid waste; 2. tension induced in geomembranes placed on landfill slopes due to earthquake loading; 3. damage to landfill liners due to liquefaction of foundation soil. A model waste, that has engineering properties similar to MSW, is presented. A model geomembrane that can be used in centrifuge tests is also presented. Results of dynamic centrifuge tests with the model geomembrane showed that an earthquake loading induces additional permanent tension (∼25%) in the geomembrane. © 2006 Taylor & Francis Group.
Resumo:
Horseflies are economically important blood-feeding arthropods and also a nuisance for humans and vectors for filariasis. They rely heavily on the pharmacological properties of their saliva to get a blood meal and suppress immune reactions of hosts. Little information is available on antihemostatic substances in horsefly salivary glands; especially no horsefly immune suppressants have been reported. By proteomics or peptidomics and coupling transcriptome analysis with pharmacological testing, several families of proteins or peptides, which act mainly on the hemostatic system or immune system of the host, were identified and characterized from 30,000 pairs salivary glands of the horsefly Tabanus yao (Diptera, Tabanidae). They are: (i) a novel family of inhibitors of platelet aggregation including two members, which possibly inhibit platelet aggregation by a novel mechanism and act on platelet membrane, (ii) a novel family of immunosuppressant peptides including 12 members, which can inhibit interferon-gamma production and increase interleukin-10 secretion, (iii) a serine protease inhibitor with 56 amino acid residues containing anticoagulant activity, (iv) a serine protease with anticoagulant activity, (v) a protease with fibrinogenolytic activity, (vi) three families of antimicrobial peptides including six members, (vii) a hyaluronidase, (viii) a vasodilator peptide, which is an isoform of vasotab identified from Hybomitra bimaculata, and interestingly (ix) two metallothioneins, which are the first metallothioneins reported from invertebrate salivary glands. The current work will facilitate the understanding of the molecular mechanisms of the ectoparasite-host relationship and help in identifying novel vaccine targets and novel leading pharmacological compounds.
Resumo:
A novel type of linear extensometer with exceptionally high resolution of 4 nm based on MEMS resonant strain sensors bonded on steel and operating in a vacuum package is presented. The tool is implemented by means of a steel thin bar that can be pre-stressed in tension within two fixing anchors. The extension of the bar is detected by using two vacuum-packaged resonant MEMS double- ended tuning fork (DETF) sensors bonded on the bar with epoxy glue, one of which is utilized for temperature compensation. Both sensors are driven by a closed loop self-oscillating transresistance amplifier feedback scheme implemented on a PCB (Printed Circuit Board). On the same board, a microcontroller-based frequency measurement circuit is also implemented, which is able to count the square wave fronts of the MEMS oscillator output with a resolution of 20 nsec. The system provides a frequency noise of 0.2 Hz corresponding to an extension resolution of 4 nm for the extensometer. Nearly perfect temperature compensation of the frequency output is achieved in the temperature range 20-35 C using the reference sensor. © 2011 IEEE.
Resumo:
Fish sausages are finely ground fish flesh, either of a single species or mixed, homogenised with starch, sugar, fat, spices and preservatives, generally filled in cylindrical synthetic or natural casings and pasteurised. Similar products containing small pieces of quality fish and lard are termed "fish ham". They are highly relished products in Japan, annual consumption exceeding 2 lakh tones. Preliminary studies have shown that they can catch a lucrative market in our country. However, being a pasteurised product which is often consumed as such without any further cooking, strict quality control measures have to be enforced so as to avoid food poisoning hazards. Besides physical characteristics like absence of damages, pin-holes, curliness and air pockets as well as jelly strength, texture and flavour, chemical characteristics like pH and acid values, moisture, carbohydrate and fat contents and volatile bases have to be assessed. A very important test that has to be carried out along with the above, before passing a lot for free distribution is the bacteriological examination to avoid the presence of pathogenic organisms.
Resumo:
Purpose: This paper seeks to measure in a quantitative way the degree of alignment among a set of performance measures between two organizations. Design/methodology/approach: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. The authors applied the test and present coefficients of misalignment across three sets of measures: those used by a service provider involved in the research, those used by customers contracting the services, and those documented in 11 contracts studied. Findings: Results confirmed a high degree of alignment between target and actual operational performance in the contracts. The alignment of customers' financial objectives and contracts' operational metrics was low. Calculations show poor alignment between the objectives of the provider and the contribution received from the contracts. Research limitations/implications: Some limitations of the conclusions include the small sample of contracts used in the calculations. Further research should include not only actual contracts, but also failed ones. Practical implications: It is possible that misaligned goals, represented in misaligned performance measures, lead to tensions in intra-firm relationships. If these tensions are not addressed properly the relationship could be unstable or terminated prematurely. This method of measuring alignment could detect early potential dangers in intra-firm relationships. Originality/value: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. Management researchers and business professionals may use this methodology when exploring degrees of alignment of performance measures in intra-functional and inter-firm relationships. © Emerald Group Publishing Limited.