936 resultados para resonance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is considerable interest in intramolecular energy transfer, especially in complexes which absorb visible light, because it is crucial to the better understanding of photoharvesting systems in photosynthetic organisms and for utilizing solar energy as well. Porphyrin dimers represent one of the best systems for the exploration of light-induced intramolecular energy transfer. Many kinds of porphyrins and porphyrin dimers have been studied over the past decade, however little attention has been paid to the influence of paramagnetic metals on the behavior of their excited states. In this thesis, Electron Paramagnetic Resonance Spectroscopy (EPR) is used to study such compounds. After light irradiation, porphyrins easily produce a variety of excited states, which are spin polarized and can be detected by the time-resolved (TR) EPR technique. The spin polarized results for vanadyl porphyrins, their electrostatically-coupled dimers, a covalently-linked copper porphyrin-free base porphyrin dimer, and free base porphyrins are presented in this thesis. From these results we can conclude that the spin polarization patterns of vanadyl porphyrins come primarily from the trip-quartet state generated by intersystem crossing (lSC) from the excited sing-doublet state through the trip-doublet state. The spin polarization pattern of electrostatically-coupled vanadyl porphyrin-free base porphyrin dimer is produced by the triplet state of the free base porphyrin half which is coupled to the unpaired electron on the vanadyl ion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boron tribalide complexes of 1,1-bis(dimethylamino)ethylene (DME) , t etramethylurea (TMU), tetramethylguanidine (TMG) , and pentamethylguanidine (PMG) and also mixed boron t r ihalide adducts of DME have been investigated by 1H and 19F NMR spectroscopy. Both nitrogen and the C-Q-H carbon of DME are possible donor a toms to boron trihal ides but complexation has been found to occur only at carbon of DME. The initial adduct acts as a Bronsted acid and gives up a proton to free DME in solut ion. A side reaction in the DME-BF, system gives rise to trace amounts of a complex aSSigned as (DME)2BF2+. (DME)2BF2+ is produced in much larger quantities in t he DME-BF3-BC13 and DME-BF,-BBr, systems by reaction of free DME with DME:BF2X (X = Cl, Br). Restricted r otation about the C-N bonds of TMUlBC13 and n1U:BBr3 has been observed at low temperatures. This complements previous work in this system and confirms oxygen donation of TMU to boron trihalides . Restricted rotation at low temperatures also has been observed in DMEboron trihalide systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proce-ss ofoxygenic photosynthesis is vital to life on Earth. the central event in photosynthesis is light induced electron transfer that converts light into energy for growth. Ofparticular significance is the membrane bound multisubunit protein known as Photosystem I (PSI). PSI is a reaction centre that is responsible for the transfer of electrons across the membrane to reduce NADP+ to NADPH. The recent publication ofa high resolution X-ray structure of PSI has shown new information about the structure, in particular the electron transfer cofactors, which allows us to study it in more detail. In PSI, the secondary acceptor is crucial for forward electron transfer. In this thesis, the effect of removing the native acceptor phylloquinone and replacing it with a series of structurally related quinones was investigated via transient electron paramagnetic resonance (EPR) experiments. The orientation of non native quinones in the binding site and their ability to function in the electron transfer process was determined. It was found that PSI will readily accept alkyl naphthoquinones and anthraquinone. Q band EPR experiments revealed that the non-native quinones are incorporated into the binding site with the same orientation of the headgroup as in the native system. X band EPR spectra and deuteration experiments indicate that monosubstituted naphthoquinones are bound to the Al site with their side group in the position occupied by the methyl group in native PSI (meta to the hydrogen bonded carbonyl oxygen). X band EPR experiments show that 2, 3- disubstituted methyl naphthoquinones are also incorporated into the Al site in the same orientation as phylloquinone, even with the presence of a halogen- or sulfur-containing side chain in the position normally occupied by the phytyl tail ofphylloquinone. The exception to this is 2-bromo-3-methyl --.- _. -. - -- - - 4 _._ _ _ - _ _ naphthoquinone which has a poorly resolved spectrum, making determination of the orientation difficuh. All of the non-native quinones studied act as efficient electron acceptors. However, forward electron transfer past the quinone could only be demonstrated for anthraquinone, which has a more negative midpoint potential than phylloquinone. In the case of anthraquinone, an increased rate of forward electron transfer compared to native PSI was found. From these results we can conclude that the rate ofelectron transfer from Al to Fx in native PSI lies in the normal region ofthe Marcus Curve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two time-resolved EPR techniques, have been used to study the light induced electron transfer(ET) in Type I photosynthetic reaction centers(RCs). First, pulsed EPR was used to compare PsaA-M688H and PsaB-M668H mutants of Chlamydomonas reinhardtii and Synechosystis sp. PCC 6803.The out-of-phase echo modulation curves combined with other EPR and optical data show that the effect of the mutations is species dependent. Second, transient and pulsed EPR data are presented which show that PsaA-A660N and PsaB-A640N mutations in C. reinhardtii alter the relative quantum yield of ET in the A- and B-branches of PS I. Third, transient EPR studies on RCs from Heliobacillus mobilis that have been exposed to oxygen show partial inhibition of ET. In the RCs in which ET still occurs, the ET kinetics and EPR spectra show evidence of oxidation of some but not all of the, BChl g and BChl g' to Chl a.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dependence of the electron transfer (ET) rate on the Photosystem I (PSI) cofactor phylloquinone (A1) is studied by time-resolved absorbance and electron paramagnetic resonance (EPR) spectroscopy. Two active branches (A and B) of electron transfer converge to the FX cofactor from the A1A and A1B quinone. The work described in Chapter 5 investigates the single hydrogen bond from the amino acid residue PsaA-L722 backbone nitrogen to A1A for its effect on the electron transfer rate to FX. Room temperature transient EPR measurements show an increase in the rate for the A1A- to FX for the PsaA-L722T mutant and an increased hyperfine coupling to the 2-methyl group of A1A when compared to wild type. The Arrhenius plot of the A1A- to FX ET in the PsaA-L722T mutant suggests that the increased rate is probably the result of a slight change in the electronic coupling between A1A- and FX. The reasons for the non-Arrhenius behavior are discussed. The work discussed in Chapter 6 investigates the directionality of ET at low temperature by blocking ET to the iron-sulfur clusters FX, FA and FB in the menB deletion mutant strain of Synechocyctis sp. PCC 6803, which is unable to synthesize phylloquinone, by incorporating the high midpoint potential (49 mV vs SHE) 2,3-dichloro-1,4-naphthoquinone (Cl2NQ) into the A1A and A1B binding sites. Various EPR spectroscopic techniques were implemented to differentiate between the spectral features created from A and B- branch electron transfer. The implications of this result for the directionality of electron transfer in PS I are discussed. The work discussed in Chapter 7 was done to study the dependence of the heterogeneous ET at low temperature on A1 midpoint potential. The menB PSI mutant contains plastiquinone-9 in the A1 binding site. The solution midpoint potential of the quinone measures 100 mV more positive then wild-type phylloquinone. The irreversible ET to the terminal acceptors FA and FB at low temperature is not controlled by the forward step from A1 to FX as expected due to the thermodynamic differences of the A1 cofactor in the two active branches A and B. Alternatives for the ET heterogeneity are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les lésions de la moelle épinière ont un impact significatif sur la qualité de la vie car elles peuvent induire des déficits moteurs (paralysie) et sensoriels. Ces déficits évoluent dans le temps à mesure que le système nerveux central se réorganise, en impliquant des mécanismes physiologiques et neurochimiques encore mal connus. L'ampleur de ces déficits ainsi que le processus de réhabilitation dépendent fortement des voies anatomiques qui ont été altérées dans la moelle épinière. Il est donc crucial de pouvoir attester l'intégrité de la matière blanche après une lésion spinale et évaluer quantitativement l'état fonctionnel des neurones spinaux. Un grand intérêt de l'imagerie par résonance magnétique (IRM) est qu'elle permet d'imager de façon non invasive les propriétés fonctionnelles et anatomiques du système nerveux central. Le premier objectif de ce projet de thèse a été de développer l'IRM de diffusion afin d'évaluer l'intégrité des axones de la matière blanche après une lésion médullaire. Le deuxième objectif a été d'évaluer dans quelle mesure l'IRM fonctionnelle permet de mesurer l'activité des neurones de la moelle épinière. Bien que largement appliquées au cerveau, l'IRM de diffusion et l'IRM fonctionnelle de la moelle épinière sont plus problématiques. Les difficultés associées à l'IRM de la moelle épinière relèvent de sa fine géométrie (environ 1 cm de diamètre chez l'humain), de la présence de mouvements d'origine physiologique (cardiaques et respiratoires) et de la présence d'artefacts de susceptibilité magnétique induits par les inhomogénéités de champ, notamment au niveau des disques intervertébraux et des poumons. L'objectif principal de cette thèse a donc été de développer des méthodes permettant de contourner ces difficultés. Ce développement a notamment reposé sur l'optimisation des paramètres d'acquisition d'images anatomiques, d'images pondérées en diffusion et de données fonctionnelles chez le chat et chez l'humain sur un IRM à 3 Tesla. En outre, diverses stratégies ont été étudiées afin de corriger les distorsions d'images induites par les artefacts de susceptibilité magnétique, et une étude a été menée sur la sensibilité et la spécificité de l'IRM fonctionnelle de la moelle épinière. Les résultats de ces études démontrent la faisabilité d'acquérir des images pondérées en diffusion de haute qualité, et d'évaluer l'intégrité de voies spinales spécifiques après lésion complète et partielle. De plus, l'activité des neurones spinaux a pu être détectée par IRM fonctionnelle chez des chats anesthésiés. Bien qu'encourageants, ces résultats mettent en lumière la nécessité de développer davantage ces nouvelles techniques. L'existence d'un outil de neuroimagerie fiable et robuste, capable de confirmer les paramètres cliniques, permettrait d'améliorer le diagnostic et le pronostic chez les patients atteints de lésions médullaires. Un des enjeux majeurs serait de suivre et de valider l'effet de diverses stratégies thérapeutiques. De telles outils représentent un espoir immense pour nombre de personnes souffrant de traumatismes et de maladies neurodégénératives telles que les lésions de la moelle épinière, les tumeurs spinales, la sclérose en plaques et la sclérose latérale amyotrophique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’accident vasculaire cérébral (AVC) est une cause principale de décès et de morbidité dans le monde; une bonne partie des AVC est causée par la plaque d’athérosclérose carotidienne. La prévention de l’AVC chez les patients ayant une plaque carotidienne demeure controversée, vu les risques et bénéfices ambigus associés au traitement chirurgical ou médical. Plusieurs méthodes d’imagerie ont été développées afin d’étudier la plaque vulnérable (dont le risque est élevé), mais aucune n’est suffisamment validée ou accessible pour permettre une utilisation comme outil de dépistage. L’élastographie non-invasive vasculaire (NIVE) est une technique nouvelle qui cartographie les déformations (élasticité) de la plaque afin de détecter les plaque vulnérables; cette technique n’est pas encore validée cliniquement. Le but de ce projet est d’évaluer la capacité de NIVE de caractériser la composition de la plaque et sa vulnérabilité in vivo chez des patients ayant des plaques sévères carotidiennes, en utilisant comme étalon de référence, l’imagerie par résonance magnétique (IRM) à haute-résolution. Afin de poursuivre cette étude, une connaissance accrue de l’AVC, l’athérosclérose, la plaque vulnérable, ainsi que des techniques actuelles d’imagerie de la plaque carotidienne, est requise. Trente-et-un sujets ont été examinés par NIVE par ultrasonographie et IRM à haute-résolution. Sur 31 plaques, 9 étaient symptomatiques, 17 contenaient des lipides, et 7 étaient vulnérables selon l’IRM. Les déformations étaient significativement plus petites chez les plaques contenant des lipides, avec une sensibilité élevée et une spécificité modérée. Une association quadratique entre la déformation et la quantité de lipide a été trouvée. Les déformations ne pouvaient pas distinguer les plaques vulnérables ou symptomatiques. En conclusion, NIVE par ultrasonographie est faisable chez des patients ayant des sténoses carotidiennes significatives et peut détecter la présence d’un coeur lipidique. Des études supplémentaires de progression de la plaque avec NIVE sont requises afin d’identifier les plaques vulnérables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mild hypothermia has a protective effect on brain edema and encephalopathy in both experimental and human acute liver failure. The goals of the present study were to examine the effects of mild hypothermia (35°C) on brain metabolic pathways using combined 1H and 13C-Nuclear Magnetic Resonance (NMR) spectroscopy, a technique which allows the study not only of metabolite concentrations but also their de novo synthesis via cell-specific pathways in the brain. :1H and 13C NMR spectroscopy using [1-13C] glucose was performed on extracts of frontal cortex obtained from groups of rats with acute liver failure induced by hepatic devascularization whose body temperature was maintained either at 37°C (normothermic) or 35°C (hypothermic), and appropriate sham-operated controls. At coma stages of encephalopathy in the normothermic acute liver failure animals, glutamine concentrations in frontal cortex increased 3.5-fold compared to sham-operated controls (P < 0.001). Comparable increases of brain glutamine were observed in hypothermic animals despite the absence of severe encephalopathy (coma). Brain glutamate and aspartate concentrations were respectively decreased to 60.9% ± 7.7% and 42.2% ± 5.9% (P < 0.01) in normothermic animals with acute liver failure compared to control and were restored to normal values by mild hypothermia. Concentrations of lactate and alanine in frontal cortex were increased to 169.2% ± 15.6% and 267.3% ± 34.0% (P < 0.01) respectively in normothermic rats compared to controls. Furthermore, de novo synthesis of lactate and alanine increased to 446.5% ± 48.7% and 707.9% ± 65.7% (P < 0.001), of control respectively, resulting in increased fractional 13C-enrichments in these cytosolic metabolites. Again, these changes of lactate and alanine concentrations were prevented by mild hypothermia. Mild hypothermia (35°C) prevents the encephalopathy and brain edema resulting from hepatic devascularization, selectively normalizes lactate and alanine synthesis from glucose, and prevents the impairment of oxidative metabolism associated with this model of ALF, but has no significant effect on brain glutamine. These findings suggest that a deficit in brain glucose metabolism rather than glutamine accumulation is the major cause of the cerebral complications of acute liver failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le méthotrexate (MTX), un agent anti-cancéreux fréquemment utilisé en chimiothérapie, requiert généralement un suivi thérapeutique de la médication (Therapeutic Drug Monitoring, TDM) pour surveiller son niveau sanguin chez le patient afin de maximiser son efficacité tout en limitant ses effets secondaires. Malgré la fenêtre thérapeutique étroite entre l’efficacité et la toxicité, le MTX reste, à ce jour, un des agents anti-cancéreux les plus utilisés au monde. Les techniques analytiques existantes pour le TDM du MTX sont coûteuses, requièrent temps et efforts, sans nécessairement fournir promptement les résultats dans le délai requis. Afin d’accélérer le processus de dosage du MTX en TDM, une stratégie a été proposée basée sur un essai compétitif caractérisé principalement par le couplage plasmonique d’une surface métallique et de nanoparticules d’or. Plus précisément, l’essai quantitatif exploite la réaction de compétition entre le MTX et une nanoparticule d’or fonctionnalisée avec l’acide folique (FA-AuNP) ayant une affinité pour un récepteur moléculaire, la réductase humaine de dihydrofolate (hDHFR), une enzyme associée aux maladies prolifératives. Le MTX libre mixé avec les FA-AuNP, entre en compétition pour les sites de liaison de hDHFR immobilisés sur une surface active en SPR ou libres en solution. Par la suite, les FA-AuNP liées au hDHFR fournissent une amplification du signal qui est inversement proportionnelle à la concentration de MTX. La résonance des plasmons de surface (SPR) est généralement utilisée comme une technique spectroscopique pour l’interrogation des interactions biomoléculaires. Les instruments SPR commerciaux sont généralement retrouvés dans les grands laboratoires d’analyse. Ils sont également encombrants, coûteux et manquent de sélectivité dans les analyses en matrice complexe. De plus, ceux-ci n’ont pas encore démontré de l’adaptabilité en milieu clinique. Par ailleurs, les analyses SPR des petites molécules comme les médicaments n’ont pas été explorés de manière intensive dû au défi posé par le manque de la sensibilité de la technique pour cette classe de molécules. Les développements récents en science des matériaux et chimie de surfaces exploitant l’intégration des nanoparticules d’or pour l’amplification de la réponse SPR et la chimie de surface peptidique ont démontré le potentiel de franchir les limites posées par le manque de sensibilité et l’adsorption non-spécifique pour les analyses directes dans les milieux biologiques. Ces nouveaux concepts de la technologie SPR seront incorporés à un système SPR miniaturisé et compact pour exécuter des analyses rapides, fiables et sensibles pour le suivi du niveau du MTX dans le sérum de patients durant les traitements de chimiothérapie. L’objectif de cette thèse est d’explorer différentes stratégies pour améliorer l’analyse des médicaments dans les milieux complexes par les biocapteurs SPR et de mettre en perspective le potentiel des biocapteurs SPR comme un outil utile pour le TDM dans le laboratoire clinique ou au chevet du patient. Pour atteindre ces objectifs, un essai compétitif colorimétrique basé sur la résonance des plasmons de surface localisée (LSPR) pour le MTX fut établi avec des nanoparticules d’or marquées avec du FA. Ensuite, cet essai compétitif colorimétrique en solution fut adapté à une plateforme SPR. Pour les deux essais développés, la sensibilité, sélectivité, limite de détection, l’optimisation de la gamme dynamique et l’analyse du MTX dans les milieux complexes ont été inspectés. De plus, le prototype de la plateforme SPR miniaturisée fut validé par sa performance équivalente aux systèmes SPR existants ainsi que son utilité pour analyser les échantillons cliniques des patients sous chimiothérapie du MTX. Les concentrations de MTX obtenues par le prototype furent comparées avec des techniques standards, soit un essai immunologique basé sur la polarisation en fluorescence (FPIA) et la chromatographie liquide couplée avec de la spectrométrie de masse en tandem (LC-MS/MS) pour valider l’utilité du prototype comme un outil clinique pour les tests rapides de quantification du MTX. En dernier lieu, le déploiement du prototype à un laboratoire de biochimie dans un hôpital démontre l’énorme potentiel des biocapteurs SPR pour utilisation en milieux clinique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entailing of phosphorus exchanges in most bio-chemicals as a key factor in disease, increases researcher’s interest to develop the technologies capable of detecting this metabolite. Phosphorus magnetic resonance spectroscopy is able to detect key metabolites in a non-invasive manner. Particularly, it offers the ability to measure the dynamic rate of phosphocreatine(PCr) degeneration through the exercise and recovery. This metric as a valid indication of mitochondrial oxidative metabolism in muscle, differentiate between normal and pathological state. To do magnetic resonance imaging and spectroscopy, clinical research tools provide a wide variety of anatomical and functional contrasts, however they are typically restricted to the tissues containing water or hydrogen atoms and they are still blind to the biochemicals of other atoms of interests. Through this project we intended to obtain the phosphorus spectrum in human body – specificadenerativelly in muscle – using 31P spectroscopy. To do so a double loop RF surface coil, tuned to phosphorus frequency, is designed and fabricated using bench work facilities and then validated through in vitro spectroscopy using 3 Tesla Siemens scanner. We acquired in vitro as well as in vivo phosphorus spectrum in a 100 mM potassium phosphate phantom and human calf muscle in rest-exercise-recovery phase in a 3T MR scanner. The spectrum demonstrates the main constituent in high-energy phosphate metabolism. We also observed the dynamic variation of PCr for five young healthy subjects who performed planter flexions using resistance band during exercise and recovery. The took steps in this project pave the way for future application of spectroscopic quantification of phosphate metabolism in patients affected by carotid artery disease as well as in age-matched control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La résonance magnétique cardiovasculaire sensible à l'oxygénation (OS-CMR) est devenue une modalité d'imagerie diagnostique pour la surveillance de changements dans l'oxygénation du myocarde. Cette technique offre un grand potentiel en tant qu'outil diagnostic primaire pour les maladies cardiovasculaires, en particulier la détection non-invasive d'ischémie. Par contre, il existe plusieurs facteurs potentiellement confondants de cette technique, quelques-uns d'ordre méthodologique comme les paramètres de séquençage et d'autres de nature physiologiques qui sont peut compris. En raison des effets causés par le contenu tissulaire d'eau, l'état d'hydratation peut avoir un impact sur l'intensité du signal. Ceci est un des aspects physiologiques en particulier dont nous voulions quantifier l'effet confondant par la manipulation de l'état d'hydratation chez des humains et l'observation des changements de l'intensité du signal dans des images OS-CMR. Méthodes: In vitro: Du sang artériel et veineux de huit porcs a été utilisé pour évaluer la dilution en série du sang et son effet correspondant sur l'intensité du signal de la séquence OS. In vivo: Vingt-deux volontaires en santé ont subi OS-CMR. Les concentrations d'hémoglobine (Hb) ont été mesurées au niveau de base et immédiatement après une l'infusion cristalloïde rapide de 1000 mL de solution Lactate Ringer's (LRS). Les images OS-CMR ont été prises dans une vue mid-ventriculaire court axe. L'intensité du signal myocardique a été mesurée durant une rétention respiratoire volontaire maximale, suite à une période d'hyperventilation de 60 secondes. Les changements dans l'intensité du signal entre le début et la fin de la rétention de la respiration ont été exprimés relativement au niveau de base (% de changement). Résultats: L'infusion a résulté en une diminution significative de l'Hb mesurée (142.5±3.3 vs. 128.8±3.3 g/L; p<0.001), alors que l'IS a augmenté de 3.2±1.2% entre les images du niveau de base en normo- et hypervolémie (p<0.05). L'IS d'hyperventilation ainsi que les changements d'IS induits par l'apnée ont été attenués après hémodilution (p<0.05). L'évaluation quantitative T2* a démontré une corrélation négative entre le temps de T2* et la concentration d'hémoglobine (r=-0.46, p<0.005). Conclusions: Il existe plusieurs éléments confondants de la technique OS-CMR qui requièrent de l'attention et de l'optimisation pour une future implémentation clinique à grande échelle. Le statut d'hydratation en particulier pourrait être un élément confondant dans l'imagerie OS-CMR. L'hypervolémie mène à une augmentation en IS au niveau de base et atténue la réponse IS durant des manoeuvres de respiration vasoactives. Cette atténuation de l'intensité du signal devrait être tenue en compte et corrigée dans l'évaluation clinique d'images OS-CMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le foie est un organe vital ayant une capacité de régénération exceptionnelle et un rôle crucial dans le fonctionnement de l’organisme. L’évaluation du volume du foie est un outil important pouvant être utilisé comme marqueur biologique de sévérité de maladies hépatiques. La volumétrie du foie est indiquée avant les hépatectomies majeures, l’embolisation de la veine porte et la transplantation. La méthode la plus répandue sur la base d'examens de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM) consiste à délimiter le contour du foie sur plusieurs coupes consécutives, un processus appelé la «segmentation». Nous présentons la conception et la stratégie de validation pour une méthode de segmentation semi-automatisée développée à notre institution. Notre méthode représente une approche basée sur un modèle utilisant l’interpolation variationnelle de forme ainsi que l’optimisation de maillages de Laplace. La méthode a été conçue afin d’être compatible avec la TDM ainsi que l' IRM. Nous avons évalué la répétabilité, la fiabilité ainsi que l’efficacité de notre méthode semi-automatisée de segmentation avec deux études transversales conçues rétrospectivement. Les résultats de nos études de validation suggèrent que la méthode de segmentation confère une fiabilité et répétabilité comparables à la segmentation manuelle. De plus, cette méthode diminue de façon significative le temps d’interaction, la rendant ainsi adaptée à la pratique clinique courante. D’autres études pourraient incorporer la volumétrie afin de déterminer des marqueurs biologiques de maladie hépatique basés sur le volume tels que la présence de stéatose, de fer, ou encore la mesure de fibrose par unité de volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The arrow shaped microstrip antenna, which produces dual frequency dual polarisation operation with considera-ble size reduction compared to conventional patches has been reported [I]. These antennas provide greater area reduction and improved gain compared to drum shaped patches [2]. Prediction of the resonance frequency of drum shaped patches [3] and circular patches for broadband operation [4] are available in the literature. In this Letter, we propose empirical formulas for calculating the resonance frequencies of the arrow shaped microstrip antenna. These antennas can be employed for obtaining dual frequency with the same polarisation, bandwidth enhancement, circular polarisation etc. by varying its different parameters or by introducing slots. The proposed design equations provide an easier and simple way of predicting the resonant frequencies of these patches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for calculating the resonance frequencies of a compact arrow-shaped microstrip antenna is presented and discussed . The accuracy of the method is validated by experimental results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and inexpensive linear magnetic field sweep generating system suitable for magnetic resonance experiments is described. The circuit, utilising a modified IC bootstrap configuration, generates field sweep over a wide range of sweep durations with excellent sweep linearity.