In this work a new approach for designing planar gradient coils is outlined for the use in an existing MRI apparatus. A technique that allows for gradient field corrections inside the diameter-sensitive volume is deliberated. These corrections are brought about by making changes to the wire paths that constitute the coil windings, and hence, is called the path correction method. The existing well-known target held method is used to gauge the performance of a typical gradient coil. The gradient coil design methodology is demonstrated for planar openable gradient coils that can be inserted into an existing MRI apparatus. The path corrected gradient coil is compared to the coil obtained using the target field method. It is shown that using a wire path correction with optimized variables, winding patterns that can deliver high magnetic gradient field strengths and large imaging regions can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. Technical note with illustrative case reports. Respiratory intensive care unit. Patients with acute respiratory distress syndrome. Lung recruitment and PEEP titration maneuver. Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse < 10%) were 19 and 17 cmH(2)O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous studies have documented increased breast cancer risks with hormone replacement therapy (HRT), but these do not give a woman her specific absolute risk for the remainder of her life. This article estimates the magnitude of the effect of HRT on breast cancer incidence in California and calculates a woman's cumulative risk of breast cancer with different formulations and durations of HRT use. The effects of HRT on the underlying breast cancer incidence were estimated using the attributable fraction method, applying HRT prevalence data from the 2001 California Health Interview Survey and published rates of higher relative risk (RR) from HRT use from the Women's Health Initiative (WHI) study and Million Women's Survey (MWS). The annual number of breast cancers potentially attributable to HRT in California was estimated, along with individual cumulative risk of breast cancer for various ages to 79 years according to HRT use, duration, and formulation. Using the WHI data, 829 of 19,000 breast cancers (4.3%) in California may be attributable to HRT This figure increases to 3401 (17.4%) when the MWS RRs are applied. Use of estrogen-only HRT or short-term (approximately 5 years) use of combined HRT has a minimal effect on the cumulative risk calculated to the age of 79 years; application of the MWS data to a Californian woman commencing HRT at the age of 50 years (no HRT, 8.5%; estrogen only, 8.6%; combined, 9.1%). Prolonged (approximately 10 years) use of combined HRT increases the cumulative risk to 10.3%. This article demonstrates that HRT will generate a small additional risk of breast cancer in an individual. The reduction in perimenopausal symptoms may be considered sufficient to warrant this extra risk. However, this view needs to be balanced because the small increases in individual risk will be magnified, producing a noticeable change in population cancer caseload where HRT use is high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. There has been a lot of debate about the use of predicted oxygen consumption to calculate pulmonary vascular resistance using the Fick principle. We therefore comparatively analyzed predicted oxygen consumption in infants and children in specific age groups, using different methods (formulas), as an attempt to better understand the usefulness and limitations of predictions. Methods and Results. Four models (LaFarge & Miettinen, Bergstra et al., Lindahl, and Lundell et al.) were used to predict oxygen consumption in 200 acyanotic patients with congenital cardiac defects aged 0-2.0, > 2.0-4.0, > 4.0-6.0, and > 6.0-8.75 years (median 2.04 years). Significant differences were observed between the age groups (P < .001) and between the methods (P < .001), not related to diagnoses. Differences between methods were more impressive in the first age group (P < .01). In patients aged 0-2.0 years, the lowest values of oxygen consumption (corresponding to the highest estimates of pulmonary vascular resistance) were obtained with the method of Lindahl; above this age, any method except that of Lundell et al. Conclusions. Although measuring oxygen consumption is always preferable, a rational use of predictions, using different methods, may be of help in situations where measurements are definitely not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved method for counting virus and virus like particles by electron microscopy (EM) was developed. The procedure involves the determination of the absolute concentration of pure or semi-pure particles once deposited evenly on EM grids using either centrifugation or antibody capture techniques. The counting of particles was done with a Microfiche unit which enlarged approximately 50 x the image of particles on a developed negative film which had been taken at a relatively low magnification (2500 x) by EM. Initially, latex particles of a known concentration were counted using this approach, to prove the accuracy of the technique. The latex particles were deposited evenly on an EM grid using centrifugation (Modified Beckmen EM-90 Airfuge technique). Subsequently, recombinant Bluetongue virus (BTV) core-like particles (CLPs) captured by a Monoclonal antibody using a hovel sample loading method were counted by the Microfiche unit method and by a direct EM method. Comparison of the simplified counting method developed with a conventional method, showed good agreement. The method is simple, accurate, rapid, and reproducible when used with either pure particles or with particles from crude cell culture extracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimal perfect hash functions are used for memory efficient storage and fast retrieval of items from static sets. We present an infinite family of efficient and practical algorithms for generating order preserving minimal perfect hash functions. We show that almost all members of the family construct space and time optimal order preserving minimal perfect hash functions, and we identify the one with minimum constants. Members of the family generate a hash function in two steps. First a special kind of function into an r-graph is computed probabilistically. Then this function is refined deterministically to a minimal perfect hash function. We give strong theoretical evidence that the first step uses linear random time. The second step runs in linear deterministic time. The family not only has theoretical importance, but also offers the fastest known method for generating perfect hash functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MCM-41 samples of various pore dimensions are synthesized. Plotting of nitrogen adsorption data at 77 K versus the statistical film thickness (comparison plot) reveals three distinct stages, with a characteristic of two points of inflection. The steep intermediate stage caused by capillary condensation occurred in the highly uniform mesopores. From the slopes of the sections before and after the condensation, the surface area of the mesopores is calculated. The linear portion of the last section is extrapolated to the adsorption axis of the comparison plot, and this intercept is used to obtain the volume of the mesopores. From the surface area and pore volume, average mesopore diameter is calculated, and the value thus obtained is in good agreement with the pore dimension obtained from powder X-ray diffraction measurements. The principle of the calculation as well as problems associated are discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO). METHODS We evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW. Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded. After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction. RESULTS The UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g. We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups. CONCLUSION Despite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preoperative progressive pneumoperitoneum (PPP) is a safe and effective procedure in the treatment of large incisional hernia (size > 10 cm in width or length) with loss of domain (LIHLD). There is no consensus in the literature on the amount of gas that must be insufflated in a PPP program or even how long it should be maintained. We describe a technique for calculating the hernia sac volume (HSV) and abdominal cavity volume (ACV) based on abdominal computerized tomography (ACT) scanning that eliminates the need for subjective criteria for inclusion in a PPP program and shows the amount of gas that must be insufflated into the abdominal cavity in the PPP program. Our technique is indicated for all patients with large or recurrent incisional hernias evaluated by a senior surgeon with suspected LIHLD. We reviewed our experience from 2001 to 2008 of 23 consecutive hernia surgical procedures of LIHLD undergoing preoperative evaluation with CT scanning and PPP. An ACT was required in all patients with suspected LIHLD in order to determine HSV and ACV. The PPP was performed only if the volume ratio HSV/ACV (VR = HSV/ACV) was a parts per thousand yen25% (VR a parts per thousand yen 25%). We have performed this procedure on 23 patients, with a mean age of 55.6 years (range 31-83). There were 16 women and 7 men with an average age of 55.6 years (range 31-83), and a mean BMI of 38.5 kg/m(2) (range 23-55.2). Almost all patients (21 of 23 patients-91.30%) were overweight; 43.5% (10 patients) were severely obese (obese class III). The mean calculated volumes for ACV and HSV were 9,410 ml (range 6,060-19,230 ml) and 4,500 ml (range 1,850-6,600 ml), respectively. The PPP is performed by permanent catheter placed in a minor surgical procedure. The total amount of CO(2) insufflated ranged from 2,000 to 7,000 ml (mean 4,000 ml). Patients required a mean of 10 PPP sessions (range 4-18) to achieve the desired volume of gas (that is the same volume that was calculated for the hernia sac). Since PPP sessions were performed once a day, 4-18 days were needed for preoperative preparation with PPP. The mean VR was 36% (ranged from 26 to 73%). We conclude that ACT provides objective data for volume calculation of both hernia sac and abdominal cavity and also for estimation of the volume of gas that should be insufflated into the abdominal cavity in PPP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and rapid HPLC assay for determining cefuroxime penetration in the subcutaneous tissue near to surgical incision of patients submitted to coronary artery bypass grafting (CABC) with or without cardiopulmonary bypass (CPB) was performed. Blood and subcutaneous tissue samples were collected from 14 patients. in four periods during surgery. The analytical method presented linearity from 0.5 to 100 mu g/g. LOQ = 0.50 mu g/g, LOD = 0.25 mu g/g. intra- and interday precision (%CV) ranged from 4.9 to 8.9% and 6.4 to 9.9%, respectively, and intra-and interday accuracy expressed as % of the nominal concentration ranged from 87.1 to 104.6% and 94.8 to 103.8%, respectively (mean of three concentrations). Relative recovery was 98.4%. Tissue/plasma ratios obtained for CPB and non-CPB were, respectively: 14.6% vs 19.0% (0.6 h); 15.7% vs 15.7% (2.1 h); 22.5% vs 19.9% (3.6 h); 15.7% vs 18.8% (4.5 h). Data obtained indicate that tissue/plasma ratio remains unchanged in CPB and non-CPB patients during all period of surgery and the CPB does not affect the penetration of cefuroxime in tissues close to the surgical wound. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The diagnosis of prostate cancer in men with persistently increased prostate specific antigen after a negative prostate biopsy has become a great challenge for urologists and pathologists. We analyzed the diagnostic value of 6 genes in the tissue of patients with prostate cancer. Materials and Methods: The study was comprised of 50 patients with localized disease who underwent radical prostatectomy. Gene selection was based on a previous microarray analysis. Among 4,147 genes with different expressions between 2 pools of patients 6 genes (PSMA, TMEFF2, GREB1, TH1L, IgH3 and PGC) were selected. These genes were tested for diagnostic value using the quantitative reverse transcription polymerase chain reaction method. Initially malignant tissue samples from 33 patients were analyzed and in the second part of the study we analyzed benign tissue samples from the other 17 patients with prostate cancer. The control group was comprised of tissue samples of patients with benign prostatic hyperplasia. Results: Analysis of malignant prostatic tissue demonstrated that prostate specific membrane antigen was over expressed (mean 9 times) and pepsinogen C was under expressed (mean 1.3 X 10(-4) times) in all cases compared to benign prostatic hyperplasia. The other 4 tested genes showed a variable expression pattern not allowing for differentiation between benign and malignant cases. When we tested these results in the benign prostate tissues from patients with cancer, pepsinogen C maintained the expression pattern. In terms of prostate specific membrane antigen, despite over expression in most cases (mean 12 times), 2 cases (12%) presented with under expression. Conclusions: Pepsinogen C tissue expression may constitute a powerful adjunctive method to prostate biopsy in the diagnosis of prostate cancer cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is presented for computing the fields produced by radio frequency probes of the type used in magnetic resonance imaging. The effects of surrounding the probe with a shielding coil, intended to eliminate stray fields produced outside the probe, are included. An essential feature of these devices is the fact that the conducting rungs of the probe are of finite width relative to the coil radius, and it is therefore necessary to find the distribution of current within the conductors as part of the solution process. This is done here using a numerical method based on the inverse finite Hilbert transform, applied iteratively to the entire structure including its shielding coils. It is observed that the fields are influenced substantially by the width of the conducting rungs of the probe, since induced eddy currents within the rungs become more pronounced as their width is increased. The shield is also shown to have a significant effect on both the primary current density and the resultant fields. Quality factors are computed for these probes and compared with values measured experimentally.