991 resultados para pressure drop


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: An inverse relationship between blood pressure and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We prospectively examined the relation between blood pressure and cognitive function in adolescence. Methods: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n=407) and 19 (n=429) years respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age-, sex- and height-specific z-scores of systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP). Results: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, body mass index, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. Conclusions: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combining data from police statistics and crime victim surveys, this article analyses the evolution of crime in Western Europe from 1988 to 2007. The results show that there is no general drop in crime. Property offences and homicide have been decreasing since the mid 1990s, while violent and drug offences have increased during the period under study. These trends highlight the limits of the explanations to the crime drop in the United States, which are based on the premise of a correlation in the evolution of all offences. The drop in property offences seems related to changes in the socioeconomic situation in Europe as well as to increases in security measures in households, and the reinforcement of private security. The increase in violent offences can be explained by the combination of several factors, including changes in youth's free time provoked by the development of the Internet, changing demographics, and the rise of episodic heavy alcohol consumption and street gangs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We did a subject-level meta-analysis of the changes (Δ) in blood pressure (BP) observed 3 and 6 months after renal denervation (RDN) at 10 European centers. Recruited patients (n=109; 46.8% women; mean age 58.2 years) had essential hypertension confirmed by ambulatory BP. From baseline to 6 months, treatment score declined slightly from 4.7 to 4.4 drugs per day. Systolic/diastolic BP fell by 17.6/7.1 mm Hg for office BP, and by 5.9/3.5, 6.2/3.4, and 4.4/2.5 mm Hg for 24-h, daytime and nighttime BP (P0.03 for all). In 47 patients with 3- and 6-month ambulatory measurements, systolic BP did not change between these two time points (P0.08). Normalization was a systolic BP of <140 mm Hg on office measurement or <130 mm Hg on 24-h monitoring and improvement was a fall of 10 mm Hg, irrespective of measurement technique. For office BP, at 6 months, normalization, improvement or no decrease occurred in 22.9, 59.6 and 22.9% of patients, respectively; for 24-h BP, these proportions were 14.7, 31.2 and 34.9%, respectively. Higher baseline BP predicted greater BP fall at follow-up; higher baseline serum creatinine was associated with lower probability of improvement of 24-h BP (odds ratio for 20-μmol l(-1) increase, 0.60; P=0.05) and higher probability of experiencing no BP decrease (OR, 1.66; P=0.01). In conclusion, BP responses to RDN include regression-to-the-mean and remain to be consolidated in randomized trials based on ambulatory BP monitoring. For now, RDN should remain the last resort in patients in whom all other ways to control BP failed, and it must be cautiously used in patients with renal impairment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Persons in palliative care develop pressure ulcers (PU) as death approaches, but the extent of the problem is still unknown. The objectives were to identify the prevalence of pressure ulcers in people with cancer in palliative home care, compare the socio-demographic and clinical profile of patients with and without pressure ulcers, and analyze the characteristics of the ulcers. This descriptive, cross-sectional study included 64 people with advanced cancer in palliative home care. Twelve of them (18.8%) had PU, of whom 75.0% were men. The participants had one to three PU, amounting to 19 lesions, 89.4% of those developed at home and 47.4% at stage 3. The presence of PU was higher among those who had a history of previous wound. PU consisted of a significant event occurring in the studied population, indicating that preventive measures should be included in the home palliative care health team.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: It is well established by a large number of randomized controlled trials that lowering blood pressure (BP) and low-density lipoprotein cholesterol (LDL-C) by drugs are powerful means to reduce stroke incidence, but the optimal BP and LDL-C levels to be achieved are largely uncertain. Concerning BP targets, two hypotheses are being confronted: first, the lower the BP, the better the treatment outcome, and second, the hypothesis that too low BP values are accompanied by a lower benefit and even higher risk. It is also unknown whether BP lowering and LDL-C lowering have additive beneficial effects for the primary and secondary prevention of stroke, and whether these treatments can prevent cognitive decline after stroke. RESULTS: A review of existing data from randomized controlled trials confirms that solid evidence on optimal BP and LDL-C targets is missing, possible interactions between BP and LDL-C lowering treatments have never been directly investigated, and evidence in favour of a beneficial effect of BP or LDL-C lowering on cognitive decline is, at best, very weak. CONCLUSION: A new, large randomized controlled trial is needed to determine the optimal level of BP and LDL-C for the prevention of recurrent stroke and cognitive decline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM. METHODS: We analyzed the data of 2385 consecutive patients referred to our hypertension clinic for the performance of ABPM. Before ambulatory monitoring was performed, a nurse-measured BP was obtained three times using a Y-tube connecting the sphygmomanometer and the recorder. We compared the mean value of the three nurse-measured blood pressures with that of the 12h daytime ambulatory monitoring, considered as the reference. RESULTS: The difference between the nurse-measured and the ambulatory blood pressure was small but statistically significant, indicating that nurse-measured blood pressure tends to overestimate both diastolic and systolic blood pressure. The difference between the nurse blood pressure and ABPM was greater among treated hypertensive patients than untreated patients. To diagnose hypertension, defined as a blood pressure of over 140/90mmHg by ABPM, the positive predictive value of the nurse blood pressure was 0.81 and the negative predictive value 0.63. However, these predictive values could be improved with less stringent cut-off values of blood pressure. Thus, for a diastolic blood pressure above 100mmHg, the positive predictive value of nurse blood pressure was 0.55 and the negative predictive value 0.91. These figures were relatively similar for previously treated and untreated patients. CONCLUSION: Nurse blood pressure is less accurate than ABPM in diagnosing hypertension, defined as a blood pressure of over 140/90mmHg. It could, however, be an acceptable substitute, especially to exclude people who do not need to be treated, in situations where lower resources require a less rigorous definition of hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To identify the nursing care prescribed for patients in risk for pressure ulcer (PU) and to compare those with the Nursing Interventions Classification (NIC) interventions. Method: Cross mapping study conducted in a university hospital. The sample was composed of 219 adult patients hospitalized in clinical and surgical units. The inclusion criteria were: score ≤ 13 in the Braden Scale and one of the nursing diagnoses, Self-Care deficit syndrome, Impaired physical mobility, Impaired tissue integrity, Impaired skin integrity, Risk for impaired skin integrity. The data were collected retrospectively in a nursing prescription system and statistically analyzed by crossed mapping. Result: It was identified 32 different nursing cares to prevent PU, mapped in 17 different NIC interventions, within them: Skin surveillance, Pressure ulcer prevention and Positioning. Conclusion: The cross mapping showed similarities between the prescribed nursing care and the NIC interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the effectiveness of enteral nutritional therapy (ENT) in the healing process of pressure ulcers (PU) in adults and the elderly. METHOD A systematic review whose studies were identified through the databases of Cochrane, MEDLINE/PubMed, SciELO, LILACS, EMBASE, CINAHL, Web of Science, and manual searches. It included randomized clinical trials (RCTs) without delimiting the period or language of publication, which addressed adults and elderly patients with pressure ulcers in a comparative treatment of enteral nutritional therapy and placebo or between enteral nutritional therapy with different compositions and dosages. RESULTS We included ten studies that considered different interventions. It resulted in more pressure ulcers healed in the groups that received the intervention. The included studies were heterogeneous with regard to patients, the type of intervention, the sample and the follow-up period, all of which made meta-analysis impossible. CONCLUSION Although the enteral nutritional therapy demonstrates a promotion of pressure ulcer healing, sufficient evidence to confirm the hypothesis was not found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: : Increases in plasma angiotensinogen (Ang-N) due to genetic polymorphisms or pharmacological stimuli like estrogen have been associated with a blood pressure (BP) rise, increased salt sensitivity and cardiovascular risk. The relationship between Ang-N, the resetting of the renin-angiotensin system, and BP still remains unclear. Angiotensin (Ang) II-induced genetic hypertension should respond to lisinopril treatment. METHODS: : A new transgenic rat line (TGR) with hepatic overexpression of native (rat) Ang-N was established to study high plasma Ang-N. The transgene contained a mutation producing Val-Ang-II, which was measured separately from nontransgenic Ile-Ang-II in plasma and renal tissue. RESULTS: : Male homozygous TGR had increased plasma Ang-N (∼20-fold), systolic BP (ΔBP + 26 mmHg), renin activity (∼2-fold), renin activity/concentration (∼5-fold), total Ang-II (∼2-fold, kidney 1.7-fold) but decreased plasma renin concentrations (-46%, kidney -85%) and Ile-Ang-I and II (-93%, -94%) vs. controls. Heterozygous TGR exhibited ∼10-fold higher plasma Ang-N and 17 mmHg ΔBP. Lisinopril decreased their SBP (-23 vs. -13 mmHg in controls), kidney Ang-II/I (∼3-fold vs. ∼2-fold) and Ile-Ang-II (-70 vs. -40%), and increased kidney renin and Ile-Ang-I (>2.5-fold vs. <2.5-fold). Kidney Ang-II remained higher and renin lower in TGR compared with controls. CONCLUSION: : High plasma Ang-N increases plasma and kidney Ang-II levels, and amplifies the plasma and renal Ang-II response to a given change in renal renin secretion. This enzyme-kinetic amplification dominates over the Ang-II mediated feedback reduction of renin secretion. High Ang-N levels thus facilitate hypertension via small increases of Ang II and may influence the effectiveness of renin-angiotensin system inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME: L'objectif de cette étude était de déterminer l'impact de la grossesse non compliquée sur l'onde de pouls de la pression aortique centrale. Méthode 66 femmes au total avec une grossesse simple ont été réparties en trois groupes selon le stade de leur gestation: premier trimestre (T1, n=22), deuxième trimestre (T2, n=20) et troisième trimestre (T3, n=24). Le groupe contrôle (C, n=21) était constitué de femmes non enceintes, en bonne santé habituelle, prenant une contraception oestroprogestative. La tonométrie d'aplanation a été utilisée pour l'acquisition des ondes de pouls centrale un appareil disponible dans le commerce (SphygmoCor) permet l'enregistrement de l'onde de pouls périphérique avec un tonomètre d'aplanation de l'artère radiale au niveau du poignet, puis effectue sa transformation en sa forme centrale, grâce à une analyse de Fourrier et une fonction de transfert. L'influence des ondes réfléchies sur l'onde de pouls a été déterminée non seulement pendant la systole (augmentation systolique), comme on procède habituellement dans l'analyse de l'onde de pouls, mais aussi pendant la diastole (augmentation diastolique). Résultats Au cours de la grossesse, les pressions centrales systolique et diastolique sont restées inchangées et comparables aux valeurs mesurées chez les femmes qui ne sont pas enceintes. Dans le groupe contrôle, l'augmentation systolique s'élevait à 8.1±7.5% de la pression de pouls ; il n'y avait pas de différence statistiquement significative avec les valeurs obtenues chez les femmes enceintes, et ce, à n'importe quel stade de la grossesse (T1 : 4.6±11.4%, T2: 5.0±9.3%, T3 : 4.7±8.1%). Par contre, l'amplitude de l'augmentation diastolique diminuait avec la progression de la grossesse (C 6.5±2.4%, T1 : 5.2±3.1%, T2 : 3.8±2.6%; P=0.002 versus C; T3 : 2.3±2.0%; P<0.0001 versus C et P=0.004 versus T 1). Conclusion La grossesse ne modifie pas la forme de l'onde de pouls systolique centrale, ce qui implique de la part du système cardiovasculaire une adaptation fine à la demande croissante de flux sanguin, et ce, à tous les stades de la grossesse. Par contre, l'amplitude de l'onde de réflexion atteignant l'aorte pendant la diastole diminue progressivement au cours de la grossesse. Perspectives De récentes études montrent qu'une valeur anormalement haute de l'augmentation systolique de la pression centrale, comme on peut la déterminer avec la tonométrie d'aplanation, pourrait être un indice de trouble hypertensif de la grossesse débutant. Cette technique simple pourrait être d'autant plus facile à mettre en oeuvre si les valeurs normales pour l'augmentation systolique étaient indépendantes du stade de la grossesse, comme le suggèrent nos résultats, du moins pour les mesures prises en position assise.