996 resultados para prescribed fire


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in pre-kindergarten to third grade in Austin, TX during a summer day camp in 2007.^ Methods: Data was collected from child participants via teacher and researcher administered tests at pretest, posttest (immediately after the completion of the fire safety module), and at a 3 week follow-up to asses retention. In addition, a self-administered questionnaire was collected from parents pre- and post-intervention to assess home-related fire/burn risk factors. Paired t-tests were conducted using STATA 12.0 to evaluate pretest, posttest, and retention test mean scores as well as mean fire safety rules listed by grade group. McNemar's test was used to determine if there was a difference in fire-related risk factors as reported by the parents of the participants before and after the intervention. Only those who had paired data for the tests/surveys being compared were included in the analysis.^ Results: The first/second grade group and the third grade group scored significantly higher on fire safety knowledge on the posttest compared to the pretest (p<0.0001 for both groups). However, there was no significant change in knowledge scores for the pre-kindergarten to kindergarten group (p=0.14). Among the first/second grade group, knowledge levels did not significantly decline between the posttest and retention test (p=0.25). However, the third grade group had significantly lower fire safety knowledge scores on the retention test compared to the posttest (p<0.001). A similar increase was seen in the amount of fire safety rules listed after the intervention (p<0.0001 between pre and posttest for both the first/second grade and third grade groups), with no decline from the posttest to the retention test (p=0.50) for the first/second grade group, but a significant decline in the third grade group (p=0.001). McNemar's chi-square test showed a significant increase in the percentage of participants' parents reporting smoke detector testing on a regular basis and having a fire escape plan for their family after the intervention (p=0.01 and p<0.0001, respectively). However, there was no significant change in the frequency of reports of the child playing in the kitchen while the parent cooks or the house/apartment having a working smoke detector.^ Conclusion: We found that general fire safety knowledge improved and the number of specific fire safety rules increased among the first to third grade children who participated in the Danger Rangers fire safety program. However, it did not significantly increase general fire safety knowledge among the pre-k/k group. This study also showed that a program targeted towards children has the potential to influence familial risk factors by proxy. The Danger Rangers Fire Safety Curriculum should be further evaluated by conducting a randomized controlled trial, using valid measures that assess fire safety attitudes, beliefs, behaviors, as well as fire/burn related outcomes.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Health Belief Model (HBM) provided the theoretical framework for examining Universal Precautions (UP) compliance factors by Firefighter, EMTs and Paramedics (prehospital care providers). A convenient sample of prehospital care providers (n = 4000) from two cities (Houston and Washington DC), were surveyed to explore the factors related to their decision to comply with Universal Precautions. Eight hundred and sixty-five useable questionnaires were analyzed. The responders were primarily male (95.7%) eight hundred and twenty-eight and thirty-seven were female, prehospital based (100%), EMTs (60.0%) and paramedics (12.8%) who had a mean 13 years of prehospital care experience. ^ Linear regression was used to evaluate the four hypotheses. The first hypothesis evaluating perceived susceptibility and seriousness with reported UP use was statistically significant (p = < .05). Perceived susceptibility, when considered independently, did not make a significant contribution (t = −4.2852; p = 0.0000) to the stated use of Universal precautions. The hypothesis is not supported as stated. The data indicates the opposite effect. Supported is the premise that as perceived susceptibility and perceived seriousness increase the use of Universal Precautions decreases. Hypothesis two tested perceived benefits with internal and external barriers. Both perceived benefits and internal and external barriers as well as the overall regression were significant (F = 112.6, p = 0.0000). The contribution of internal and external barriers was statistically significant (t = 0.0175; p = 0.0000) and (t = 0.0128; p = 0.0000). Hypothesis three which tested modifying factors, cues to action, select demographic variables, and the main effects of the HBM with self reported UP compliance overall was significant. The variables gender, birth, education, job type, EMS certification, years of service, years of experience providing patient care, Universal Precautions training hours, type of apparatus assigned to and the number of EMS related incidents responded to in a month were found to have a significant contribution to the stated use of Universal Precautions. ^ The additive effects were tested by use of a stepwise regression that assessed the contribution of each of the significant variables. Three variables in the equation were statistically significant. Internal barriers (t = −8.5507; p = 0.0000), external barriers (t = −6.2862; p = 0.000) and job type 2 & 3. Job type two (t = −2.8464; p = 0.0045 is titled Engineer/Operator. Job type three (t = −2.5730; p = 0.0103) is titled captain. The overall regression was significant (F = 24.06; p = 0.000). The Hypothesis is supported in the certain demographic variables do influence the stated use of Universal precautions and that as internal and external barriers are decreased, there is an increase in the stated use of Universal Precautions. ^ In summary, this study demonstrated that internal and external barriers have a significant impact on the stated use of Universal Precautions. Internal barriers are those factors within the individual that require an internal change (i.e., forgetfulness, freedom, perception of the urgency of the patient's needs etc.) and external barriers are things in the environment that can be altered (i.e., equipment design, availability of equipment, ease of use). These two model variables explained 23%–30% of the variance. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The observed long-term decrease in the regional fire activity of Eastern Canada results in excessive accumulation of organic layer on the forest floor of coniferous forests, which may affect climate-growth relationships in canopy trees. To test this hypothesis, we related tree-ring chronologies of black spruce (Picea mariana (Mill.) B.S.P.) to soil organic layer (SOL) depth at the stand scale in the lowland forests of Quebec's Clay Belt. Late-winter and early-spring temperatures and temperature at the end of the previous year's growing season were the major monthly level environmental controls of spruce growth. The effect of SOL on climate-growth relationships was moderate and reversed the association between tree growth and summer aridity from a negative to a positive relationship: trees growing on thin organic layers were thus negatively affected by drought, whereas it was the opposite for sites with deep (>20-30 cm) organic layers. This indicates the development of wetter conditions on sites with thicker SOL. Deep SOL were also associated with an increased frequency of negative growth anomalies (pointer years) in tree-ring chronologies. Our results emphasize the presence of nonlinear growth responses to SOL accumulation, suggesting 20-30 cm as a provisional threshold with respect to the effects of SOL on the climate-growth relationship. Given the current climatic conditions characterized by generally low-fire activity and a trend toward accumulation of SOL, the importance of SOL effects in the black spruce ecosystem is expected to increase in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The video FireMovie_2000-2011.avi shows an animation with all MODIS fire product maps of the area sequenced over time. Colors in the video describe MODIS classes as follows: MODIS classification and color scale: Class 0 - not processed - Dark blue (1 frame) Class 3 - water - Light Blue (rivers and some lakes) Class 4 - clouds - Green blue Class 5 - non fire land - Yellow green Class 8 - nominal confidence fire - Red Class 9 - high confidence fire - Dark red

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of national self-determination is a highly contested concept from very outset. It is partly due to its dual parentage, namely nationalism and liberalism. Prior to 1945 it was only a political concept without legal binding. With the incorporation of the principle in the UN Charter it was universalized and legalized. However, there were two competing interpretations at the UN based on de-colonization and representative government. How to define self and what really determined remain highly controversial. How to reconcile the international norm of sovereignty of state and self determination of people became more complex problem with the tide of secessionist movements based on ethno-nationalism. The concept of internal self-determination came as a compromise; but it is also very vague and harbors a wide range of interpretations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of ventilation systems in case of fire is the reduction of the possible consequences by achieving the best possible conditions for the evacuation of the users and the intervention of the emergency services. The required immediate transition, from normal to emergency functioning of the ventilation equipments, is being strengthened by the use of automatic and semi-automatic control systems, what reduces the response times through the help to the operators, and the use of pre-defined strategies. A further step consists on the use of closed-loop algorithms, which takes into account not only the initial conditions but their development (air velocity, traffic situation, etc.), optimizing smoke control capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After an experimental fire in steep shrub land in a temperate–humid region (north-west Spain), the effects of two post-fire stabilisation treatments (grass seeding and straw mulching) on the chemical properties of eroded sediments,and the amount of nutrients lost with them, we reevaluated relative to control burnt soil, over a period of 13 months. Total C and N concentrations, and d 13 C, indicated that sediments were mainly contributed by charred plant and litter material. The highest concentrations of extractable base cations in the sediments occurred during the first 3 months following fire, especially for Na and K. As treatments had little or no effect on nutrient concentration in sediments, differences in nutrient losses were due to the 10-fold lower sediment production in mulching compared with other treatments. In control and seeding treatments, the accumulated amounts of nutrients lost with sediments were 989–1028kgha 1 (C), 77kgha 1 (N), 1.9–2.4kgha 1 (Ca), 0.9–1.1kgha 1 (Mg), 0.48–0.55kgha 1 (NH 4 þ –N), 0.39–0.56kgha 1 (K), 0.19–0.34kgha 1 (Na) and , 0.1kgha 1 (P and NO 3 –N) . These values accounted for 22–25% (total C and N) and 5–12% (NH 4 þ –N, Ca, P and Mg) of available nutrients in ash, and 1.0–2.4% of those in ash þ topsoil. As nutrient and sediment losses were strongly correlated, the reduction of the latter by mulching application leads to an effective decrease of post-fire nutrient losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of fire ( Control burned soil) and two emergency stabilisation techniques (grass Seeding and straw Mulching ) on 20 chemical characteristics were evaluated on 0 – 5 cm top-soils sampled 1, 90, 180 and 365 days after an experimental fi re in a steep shrubland of a temperate-humid region (NW Spain). Most part of pH (in H 2 O and KCl) variance was explained by the sampling date. No clear temporal trends were identi fi able for total soil C and N content, likely due to the large SOM pool in these soils; however, changes on soil δ 13 C were explained by the deposition of 13 C-depleted ashes, followed by its progressive erosion, while those on soil δ 15 N were a consequence of fi re induced N outputs. After the fi re, NH 4 + – N, P, Na, K, Mg, Ca, Mn, Cu, Zn and B concentrations increased, while those of NO 3 − – N, Al, Fe and Co did not vary significantly. Despite a significant decline with time, concentrations of Mg, Ca and Mn at the end of the study were still higher than in unburned soil, while those of K, Cu, Zn and B were similar to the pre-fire levels and those of NH 4 + – N, P and Na were below pre-fire values. Mulching and Seeding treatments for burned soil emergency stabilisation had significant effects on soil δ 15 N and extractable K, Mg and Ca, while data were inconclusive for their possible effects on the extractable Al, Fe and Co

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interacciones entre la vegetación del Holoceno, el fuego y el clima en el oeste de España, ejemplo con datos de la turbera del Maíllo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of ventilation systems in tunnels is to reach the highest possible safety level both in service and fire situation; being the fire one, the most relevant when designing the system. When designing a longitudinal ventilation system, the methodology to evaluate the capacity of the system is similar both in service and fire situation, with the exception of the chimney effect and the phenomena of thermal transfer which is responsible or the changes in the density of the air. When facing the dimensioning task for longitudinal ventilated tunnels, although similar methodologies are used in different countries, specific hypothesis (aerodynamic, thermal properties, traffic) even if discussed in the literature or current practice, are not usually detailed in the regulations or recommendations. The aim of this paper is to propose a probabilistic approach to the problem which would allow the designer, and the tunnel owner, to understand the uncertainty and sensibility adopted in the results and, eventually, identify possible ways of optimizing the ventilation solution to be adopted.