871 resultados para perception deafness
Resumo:
Our goal in this thesis is to provide a result of existence of the degenerate non-linear, non-divergence PDE which describes the mean curvature flow in the Lie group SE(2) equipped with a sub-Riemannian metric. The research is motivated by problems of visual completion and models of the visual cortex.
Resumo:
A growing number of empirical studies recently investigated consumers' valuation for local food products. However, different aspects related to the local food consumption still remain vague or unexplored. As such, the objective of the present research is to fulfill the existing literature using a mixed methodological approach for the investigation of consumers' preferences and Willingness to Pay (WTP) for local food products. First of all, local food is still a blurred concept and this factor might be source of individuals' misperception for the local origin meaning. Therefore, a qualitative research has been performed in order to investigate the meaning and the perception of the local food in the Italian food market. Results from this analysis have been used as inputs for the building of a non-hypothetical Real Choice Experiment (RCE) to estimate consumers' WTP for locally and organically produced apple sauce. The contribution of this study is three-fold: (1) consumers' valuation for the local origin is interpreted in terms of regional borders, over the organic food claim in case of an unusual food product in the area of interest, (2) the interaction between individuals' personality traits and consumers’ preferences for local and organic foods is analyzed, (3) the role of Commitment Cost creation in consumers' choice making in case of uncertainty due to the use of a novel food product and of an unconventional food claim is investigated. Results suggest that consumers are willing to pay a higher price premium for organic over locally produced apple sauce, possibly because of the presence of a regulated certification. In accordance with Commitment Cost theory, the organic label might thus decrease consumers' uncertainty for the features of the product in question. Results also indicate that individuals' personality can be source of heterogeneity in consumers' preferences.
Resumo:
The purpose of this clinical trial was to determine the active tactile sensibility of natural teeth and to obtain a statistical analysis method fitting a psychometric function through the observed data points. On 68 complete dentulous test persons (34 males, 34 females, mean age 45.9 ± 16.1 years), one pair of healthy natural teeth each was tested: n = 24 anterior teeth and n = 44 posterior teeth. The computer-assisted, randomized measurement was done by having the subjects bite on thin copper foils of different thickness (5-200 µm) inserted between the teeth. The threshold of active tactile sensibility was defined by the 50% value of correct answers. Additionally, the gradient of the sensibility curve and the support area (90-10% value) as a description of the shape of the sensibility curve were calculated. For modeling the sensibility curve, symmetric and asymmetric functions were used. The mean sensibility threshold was 14.2 ± 12.1 µm. The older the subject, the higher the tactile threshold (r = 0.42, p = 0.0006). The support area was 41.8 ± 43.3 µm. The higher the 50% threshold, the smaller the gradient of the curve and the larger the support area. The curves showing the active tactile sensibility of natural teeth demonstrate a tendency towards asymmetry, so that the active tactile sensibility of natural teeth can mathematically best be described by using the asymmetric Weibull function.
Resumo:
The data of 46 adults with single-sided sensorineural deafness who were candidates for bone-anchored hearing aids (Baha) CROS (contralateral routing of signals) were analyzed. All candidates tested a Baha with a headband in their normal environment. Subsequently, 29 of the candidates chose a permanent Baha CROS fitting, and 17 declined, thus forming the two study groups. No significant difference regarding age, sex or duration of deafness was found between the two groups. Similarly, the transcranial attenuation was not significantly different between those who accepted and declined a Baha. Subjects with some residual hearing in their poorer ear tended to decline a Baha, but the effect was not statistically significant. For a subset of 28 subjects, the Bern Benefit in Single-Sided Deafness questionnaire was administered. The questionnaire consists of 10 visual analogue scales rating the subjectively perceived benefit of the Baha or any other CROS device in different situations. Scores were found to be significantly higher for speech understanding at some distance (p = 0.026), for speech understanding in noise (p = 0.037), for group conversations (p < 0.01), and for the overall benefit (p < 0.01) for those candidates who chose to use a Baha as a CROS device permanently.
Resumo:
To investigate the effect of low-frequency attenuation of Bone-Anchored Hearing Aids (Bahas) in users with single-sided sensorineural deafness (SSD). The underlying notion is that low-frequency sounds up to approximately 1500 Hz reach the contralateral ear without significant attenuation and that Bahas tend to show more distortion at lower frequencies. Furthermore, to transmit low frequencies, higher moving masses are needed when compared with high frequencies.
Resumo:
Humans perceive the content (gist) of a scene very rapidly within about 40 ms [Castelhano and Henderson, 2008 Journal of Experimental Psychology Human Perception and Performance 43(3) 660-675]. It has also been demonstrated that colours contribute to the perception of the gist of a scene if the colours are diagnostic for the distinction of scenes (Oliva and Schyns, 2000 Cognitive Psychology 41 176-210). We presented 320 coloured photographs of 2 diagnostic (mountains and coasts) and 2 nondiagnostic colour scenes (cities and rooms), 80 per category, in a masking paradigm. The mask consisted of randomly distributed colour patches. SOA was varied between 20 and 80 ms, in steps of 20 ms and subjects had to indicate the gist of the scene (4AFC). A control condition without masking was also included. In line with previous results we have found that the gist of nondiagnostic coloured scenes is extracted within 40 ms. However, if colour comes into play, the extraction of the scene gist is prolonged by about 20 ms. A possible reason for this outcome might be that nondiagnostic colour scenes are identified by their luminance components which are processed faster than the colour information, which in turn mediates the identification of diagnostic colour scenes