944 resultados para parametric and nonparametric test
Resumo:
Pulp capping is a procedure that comprises adequate protection of the pulp tissue exposed to the oral environment, aiming at the preservation of its vitality and functions. This study evaluated the response of the dental pulps of dog teeth to capping with mineral trioxide aggregate (MTA) or calcium hydroxide P.A. For that purpose, 37 teeth were divided into two groups, according to the capping material employed. Two dogs were anesthetized and, after placement of a rubber dam, their pulps were exposed in a standardized manner and protected with the experimental capping materials. The cavities were then sealed with resin-modified glass ionomer cement and restored with composite resin. After sixty days, the animals were killed and the specimens were processed in order to be analyzed with optic microscopy. It was observed that MTA presented a higher success rate compared to calcium hydroxide, presenting a lower occurrence of infection and pulp necrosis.
Resumo:
Isotope screening is a simple and cheap test for determining the photosynthetic pathway used by plants. The scope of this work was to classify the photosynthetic type of Melissa officinalis L. and Cymbopogon citratus [DC.] Stapf, through studies of the carbon isotope composition (δ13 C), and we are proposing the use of carbon isotope composition results as a tool to control the quality of medicinal plants. For studies of δ 13C (13 C% = [R (sample)/R (standard) - 1] × 10 -3), dried, powdered leaves were analyzed in a mass spectrometer coupled with an elemental analyzer for determining the ratio R (R = 13CO2/12CO2). As results, M. officinalis presented a C3 photosynthetic type, and C. citratus presented a C4 photosynthetic type. The carbon isotope composition from this study can be used as quality control of M. officinalis adulterants.
Resumo:
There are several papers on pruning methods in the artificial neural networks area. However, with rare exceptions, none of them presents an appropriate statistical evaluation of such methods. In this article, we proved statistically the ability of some methods to reduce the number of neurons of the hidden layer of a multilayer perceptron neural network (MLP), and to maintain the same landing of classification error of the initial net. They are evaluated seven pruning methods. The experimental investigation was accomplished on five groups of generated data and in two groups of real data. Three variables were accompanied in the study: apparent classification error rate in the test group (REA); number of hidden neurons, obtained after the application of the pruning method; and number of training/retraining epochs, to evaluate the computational effort. The non-parametric Friedman's test was used to do the statistical analysis.
Resumo:
This study was performed to standardize parasite egg counting in feces of sheep by TF-Test, in addition to compare this test to the Gordon & Whitlock technique (G&W). Twenty-four lambs were artificially infected with Haemonchus contortus throughout 12 weeks. At the end of this time, faecal samples were taken and animals were slaughtered for worm identification and counting. G&W and TF-Test methods were carried out on each fecal sample. Both tests showed Haemonchus eggs in 95.8% of the samples (P>0.05). The correlation coefficients (r) between fecal egg counts (FEC) using G&W × Total Worm Count (TWC) were r=0.52 (not transformed data) and r=0.85 (transformed data); between FEC by TF-Test × TWC were r=0.51 (not transformed data) and r=0.87 (transformed data). Other 100 fecal samples were taken from naturally infected sheep. In these animals, the G&W and TF-Test methods showed 85% and 86% of fecal samples positive for Strongylidea eggs, respectively (P>0.05). Also in those animals, Eimeria oocysts were found in 33% of fecal samples by TF-Test, whereas in the G&W only 12% were positive (P<0.001). For Strongyloides spp., TF-Test showed 15% of positive fecal samples, whereas G&W showed 5% (P<0.05). In conclusion, both methods were efficient to diagnose gastrointestinal nematodes and TF-Test was superior to diagnose oocysts of Eimeria spp. and eggs of Strongyloides spp; conversely, Strongylidea eggs counting using TF-Test was underestimated.
Resumo:
The aim of this study was to evaluate the antimicrobial activity of different trademarks and compositions of gutta-percha points and calcium hydroxide pastes used in endodontic therapy. The evaluated material consisted of gutta-percha points containing calcium hydroxide (Roeko™), gutta-percha points containing chlorhexidine (Roeko™), two convencional gutta-percha points (Endo Points™ and Roeko™) and two calcium hydroxide pastes (Calen™ and Calen/PMCC™). Antimicrobial tests included five species of microorganisms: Escherichia coli (ATCC10538), Staphylococcus epidermidis (ATCC12228), Staphylococcus aureus (ATCC6538), Pseudomonas aeruginosa (ATCC27853), and Micrococcus luteus (ATCC9341). The Agar difusion method was employed. The plates were kept at room temperature for 2 h for prediffusion and then incubated at 37°C for 24 h. The triphenyltetrazolium chloride gel was added for optimization and the zones of inhibition were measured. Statistical evaluation was carried out using analysis of variance and Tukey Test. The obtained results showed that all microbial species used in the study were inhibited by the gutta-percha points containing chlorhexidine and by the calcium hydroxide pastes (Calen™ and Calen/ PMCC™), with similar results (p > 0.05). No antimicrobial activity was observed for the other groups. It was concluded that the gutta-percha points containing chlorhexidine presented antimicrobial activity, whereas the gutta-percha points containing calcium hydroxide did not.
Resumo:
OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.
Resumo:
A retrospective observational study was performed in order to evaluate the possibility of spontaneous resolution of tearing in the congenital nasolacrimal obstruction (CNLO). Twenty-seven CNLO child carriers with spontaneous tearing resolution were evaluated according to sex, age of starting and end of symptoms. The data were evaluated by the Chi-Square Test and non-parametric Mann-Whitney test (p ≤ 0.05). Spontaneous resolution occurred between ages 3 and 48 months (Median = 14 months; Mean = 16.2 ± 10.5 months). The period in which the child presented tearing varied from 2 months to 47.5 months (Median = 12 months) and was similar for both sexes, with or without realization of massage. Our data support the possibility of CNLO spontaneous resolution in children beyond 12 months of age, allowing us to suggest postponed probing beyond this time period. Copyright © Informa Healthcare.
Resumo:
OBJECTIVE: This study evaluated the efficiency of repolishing, sealing with surface sealant, and the joining of both in decreasing the surface roughness of resin-based composites after a toothbrushing process. METHOD AND MATERIALS: Ten specimens of each composite (Alert, Z100, Definite, and Prodigy Condensable), measuring 2 mm in thickness and 4 mm in diameter, were made and submitted to finishing and polishing processes on both sides of the specimens using the Sof-Lex system. The specimens were then subjected to toothbrushing (30,000 cycles), and surface roughness (Ra) was analyzed with a Surfcorder SE 1700 profilometer. The upper surface of each composite was etched with 37% phosphoric acid, and the surface-penetrating sealant Protect-it was applied on 1 surface. The roughness of these surfaces was again measured. On the other side, the surface of the specimen was repolished, and the efficiency of this procedure was measured using the profilometer. The surface roughness resulting from the joining of the 2 methods was verified by applying, in the final stage, the surface-penetrating sealant on the repolished surface. Data were analyzed with analysis of variance and Tukey test (P <.05). RESULTS: Results showed that the lowest surface roughness values were obtained for Definite, Z100, and Prodigy Condensable after the repolishing process and after the repolishing plus sealing. For Alert, the joining of repolishing plus sealing promoted the lowest values of surface roughness. CONCLUSION: Of the resin-based composites, Alert demonstrated the highest values of surface roughness in all the techniques tested.
Effect of an alcoholic diet on dental caries and on Streptococcus of the mutans group: Study in rats
Resumo:
The objective of this study was to evaluate the effects of an alcohol diet on Streptococcus of the mutans group and on dental caries in the oral cavity of rats. Forty animals were divided into 3 groups according to the following liquid diets: 20% ethanol solution (Alcohol Group, AG), 27% sucrose solution (Isocaloric Group, IG), and water (Control Group, CG). After 56 days, samples were collected and plated on Mitis Salivarius Bacitracin agar to assess the number of colony forming units (CFU/mL) of Streptococcus of the mutans group. The animals were sacrificed and the jaws were removed in order to assess the occurrence of dental caries on the smooth and occlusal surfaces using stereomicroscopy. The data were submitted to ANOVA and Tukey test. The average numbers of CFU/mL (10 3) were: 8.17 (AG), 9.78 (IG), and 5.63 (CG). There was no significant difference among the groups for the occurrence of occlusal caries. Regarding smooth surface caries, in the upper jaw, the caries number in the IG (1.58) was similar to that in the AG (2.06) and in the CG (1.14), and the number of caries in the AG was higher than in the CG; in the lower jaw there was significant difference among the 3 groups: AG (1.14), IG (2.00) and CG (0.43). The diets with the alcohol and sucrose solutions presented a tendency of increasing the colonization by Streptococcus of the mutans group and of increasing the occurrence of smooth surface dental caries in rat molars when compared to the control diet.
Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization.
Resumo:
OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.
Resumo:
Aim: Treatment of periodontal diseases is based on efficient scaling and root planing (SRP) and adequate maintenance of the patient. The effectiveness of SRP is influenced by operator skill, access to the subgingival area, root anatomy, and the quality and type of instrument used for SRP. The aim of this study was to evaluate the cutting edges of Gracey curettes after manufacturing and after resharpening using several techniques. Methods and Material: The cutting edges of a total of 41 new #5-6 stainless steel Gracey curettes were evaluated blindly using scanning electron microscopy (SEM). The quality of the cutting edges was evaluated blindly by a calibrated examiner using micrographs. Data were analyzed using a Kruskal Wallis test and nonparametric two-way multiple comparisons. Results and Conclusions: Different sharpening techniques had significantly different effects on the sharpeness of cutting edges (p<0.05). Sharpening by passing the lateral face of curettes over a sharpening stone and then a #299 Arkansas stone produced a high frequency of smooth, sharp edges or slightly irregular edges between the lateral and coronal faces of the curettes. Sharpening by passing a blunt stone over the curette's lateral face produced the poorest quality cutting edge (a bevel). Sharpening of the coronal curette face produced extremely irregular cutting edges and non-functional wire edges. Sharpening with rotary devices produced extremely irregular cutting edges.
Resumo:
Objective: To evaluate the marginal microleakage in enamel and dentin/cementum walls in preparations with a high C-factor, using 3 resin composite insertion techniques. The null hypothesis was that there is no difference among the 3 resin composite insertion techniques. Method and Materials: Standardized Class 5 cavities were prepared in the lingual and buccal aspects of 30 caries-free, extracted third molars. The prepared teeth were randomly assigned to 3 groups: (1) oblique incremental placement technique, (2) horizontal incremental placement technique, and (3) bulk insertion (single increment). The preparations were restored with a 1-bottle adhesive (Single Bond, 3M ESPE) and microhybrid resin composite (Z100, 3M ESPE). Specimens were isolated with nail varnish except for a 2-mm-wide rim around the restoration and thermocycled (1,000 thermal cycles, 5°C/55°C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50 wt% silver nitrate for 24 hours, followed by 8 hours in a photo-developing solution and evaluated for microleakage using an ordinal scale of 0 to 4. The microleakage scores obtained from occlusal and gingival walls were analyzed with Wilcoxon and Kruskal-Wallis nonparametric tests. Results: The null hypothesis was accepted. The horizontal incremental placement technique, the oblique incremental technique, and bulk insertion resulted in statistically similar enamel and dentin microleakage scores. Conclusion: Neither the incremental techniques nor the bulk placement technique were capable of eliminating the marginal microleakage in preparations with a high C-factor.
Resumo:
The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.
Resumo:
Background: program for phonological remediation in developmental dyslexia. Aim: to verify the efficacy of a program for phonological remediation in students with developmental dyslexia. Specific goals of this study involved the comparison of the linguistic-cognitive performance of students with developmental dyslexia with that of students considered good readers; to compare the results obtained in pre and post-testing situations of students with dyslexia who were and were not submitted to the program; and to compare the results obtained with the phonological remediation program in students with developmental dyslexia to those obtained in good readers. Method: participants of this study were 24 students who were divided as follows: Group I (GI) was divided in two other groups - Gle with 6 students with developmental dyslexia who were submitted to the program; and Glc with 6 students with developmental dyslexia who were not submitted to the program; Group II (GII) was also divided in two other groups - GIIe with 6 good readers who were submitted to the program, and GIIc with 6 good readers who were not submitted to the program. The phonological remediation program (Gonzalez & Rosquete, 2002) was developed in three stages: pre-testing, training and post-testing. Results: results indicate that GI presented a lower performance in phonological skills, reading and writing when compared to GII in the pre-testing situation. However, GIe presented a similar performance to that of GII in the post-testing situation, indicating the effectiveness of the phonological remediation program in students with developmental dyslexia. Conclusion: this study made evident the effectiveness of the phonological remediation program in students with developmental dyslexia.
Resumo:
BACKGROUND. This study aimed to evaluate clinical characteristics of epidural anesthesia performed with 0.75% ropivacaine associated with dexmedetomidine. METHODS. Forty patients scheduled for hernia repair or varicose vein surgeries under epidural anesthesia participated in this study. They were assigned to: Control Group (n = 20), 0.75% ropivacaine, 20 ml (150 mg); and Dexmedetomidine Group (n = 20), 0.75% ropivacaine, 20 ml (150 mg), plus dexmedetomidine, 1 μg.kg -1. The following variables were studied: total analgesic block onset time, upper level of analgesia, analgesic and motor block duration time, intensity of motor block, state of consciousness, hemodynamics, postoperative analgesia and incidence of side-effects. RESULTS. Epidural dexmedetomidine did not affect onset time or upper level of anesthesia (p > 0.05) however it prolonged sensory and motor block duration time (p < 0.05) and postoperative analgesia (p < 0.05), and also resulted in a more intense motor block, 1 (p < 0.05). Values of bispectral index were lower in Dexmedetomidine Group (p < 0.05). There was no difference in incidence of hypotension and bradycardia (p > 0.05). Occurrence of side-effects (shivering, vomiting and SpO 2 < 90%) was low and similar between groups (p > 0.05). CONCLUSION. There is clear synergism between epidural dexmedetomidine and ropivacaine, further this drug association does not bring about additional morbidity.