894 resultados para linearity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports an LC-MS/MS method with positive electrospray ionization for the screening of commonly prescribed cardiovascular drugs in human plasma, including compounds with antihypertensive (57), antidiabetic (12), hypolipemiant (5), anticoagulant (2) and platelet anti-aggregation (2) effects. Sample treatment consisted of a simple protein precipitation with MeOH/0.1 M ZnSO₄ (4:1, v/v) solution after the addition of internal standard, followed by evaporation and reconstitution. Analytes separation was performed on a Polar-RP column (150 m x 2 mm, 4 μm) using a gradient elution of 15 min. The MS system was operated in MRM mode, monitoring one quantitation and one confirmation transition for each analyte. The recovery of the protein precipitation step ranged from 50 to 70% for most of the compounds, while some were considerably affected by matrix effects. Since several analytes fulfilled the linearity, accuracy and precision values required by the ICH guidelines, the method proved to be suitable for their quantitative analysis. The limits of quantitation varied from 0.38 to 9.1 μg/L and the limits of detection from 0.12 to 5.34 μg/L. The method showed to be suitable for the detection of plasma samples of patients under cardiovascular treatment with the studied drugs, and for 55 compounds reliable quantitative results could be obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe here a new reversed-phase high-performance liquid chromatography with mass spectrometry detection method for quantifying intact cytokinin nucleotides in human K-562 leukemia cells. Tandem mass spectrometry was used to identify the intracellular metabolites (cytokinin monophosphorylated, diphosphorylated, and triphosphorylated nucleotides) in riboside-treated cells. For the protein precipitation and sample preparation, a trichloroacetic acid extraction method is used. Samples are then back-extracted with diethyl ether, lyophilized, reconstituted, and injected into the LC system. Analytes were quantified in negative selected ion monitoring mode using a single quadrupole mass spectrometer. The method was validated in terms of retention time stabilities, limits of detection, linearity, recovery, and analytical accuracy. The developed method was linear in the range of 1-1,000 pmol for all studied compounds. The limits of detection for the analytes vary from 0.2 to 0.6 pmol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The literature on the erosive potential of drinks and other products is summarised, and aspects of the conduct of screening tests as well as possible correlations of the erosive potential with various solution parameters are discussed. The solution parameters that have been suggested as important include pH, acid concentration (with respect to buffer capacity and concentration of undissociated acid), degree of saturation, calcium and phosphate concentrations, and inhibitors of erosion. Based on the available data, it is concluded that the dominant factor in erosion is pH. The effect of buffer capacity seems to be pH dependent. The degree of saturation probably has a non-linear relationship with erosion. While calcium at elevated concentrations is known to reduce erosion effectively, it is not known whether it is important at naturally occurring concentrations. Fluoride at naturally occurring concentrations is inversely correlated with erosive potential, but phosphate is probably not. Natural plant gums, notably pectin, do not inhibit erosion, so they are unlikely to interfere with the prediction of erosive potential. The non-linearity of some solution factors and interactions with pH need to be taken into account when developing multivariate models for predicting the erosive potential of different solutions. Finally, the erosive potential of solutions towards enamel and dentine might differ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report dramatic sensitivity enhancements in multidimensional MAS NMR spectra by the use of nonuniform sampling (NUS) and introduce maximum entropy interpolation (MINT) processing that assures the linearity between the time and frequency domains of the NUS acquired data sets. A systematic analysis of sensitivity and resolution in 2D and 3D NUS spectra reveals that with NUS, at least 1.5- to 2-fold sensitivity enhancement can be attained in each indirect dimension without compromising the spectral resolution. These enhancements are similar to or higher than those attained by the newest-generation commercial cryogenic probes. We explore the benefits of this NUS/MaxEnt approach in proteins and protein assemblies using 1-73-(U-C-13,N-15)/74-108-(U-N-15) Escherichia coil thioredoxin reassembly. We demonstrate that in thioredoxin reassembly, NUS permits acquisition of high-quality 3D-NCACX spectra, which are inaccessible with conventional sampling due to prohibitively long experiment times. Of critical importance, issues that hinder NUS-based SNR enhancement in 3D-NMR of liquids are mitigated in the study of solid samples in which theoretical enhancements on the order of 3-4 fold are accessible by compounding the NUS-based SNR enhancement of each indirect dimension. NUS/MINT is anticipated to be widely applicable and advantageous for multidimensional heteronuclear MAS NMR spectroscopy of proteins, protein assemblies, and other biological systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are direct alcohol consumption markers widely used nowadays for clinical and forensic applications. They are detectable in blood and urine even after consumption of trace amounts of ethanol and for a longer time frame, being detectable even when no more ethanol is present. The instability of EtG against bacterial degradation in contaminated urine samples and/or the possible postcollection synthesis of this metabolite in samples containing, e.g., Escherichia coli and ethanol, may cause false identification of alcohol uptake. Therefore, it is of paramount importance to constrict these error sources by inhibition of any bacterial growth causing hydrolization or synthesis of EtG. This study evaluates a new method of collecting urine samples on filter paper, dried urine spots (DUS), for simultaneous detection of EtG, EtS and creatinine, having the great advantage of inhibiting bacterial activity. In addition, a method validation for the determination of EtG and EtS in DUS was performed according to the FDA guidelines. Sterile-filtered urine was spiked with EtG and EtS, inoculated with E. coli and incubated. Liquid and dried urine samples were collected after various time intervals up to 96 h. Liquid samples were frozen immediately after collection, whereas aliquots for DUS were pipetted onto filter paper, allowed to dry and stored at RT until analysis 1 week after. The specimens were analyzed by LC-ESI-MS/MS. As expected, degradation of EtG, but not of EtS, was observed in contaminated liquid urine samples. However, the specimens collected on filter paper and stored at RT showed no degradation during storage. Therefore, collecting urine samples on filter paper for EtG and EtS analysis turns out to be a reliable method to avoid bacterial degradation of EtG and EtS, and consequently, stabilization of these ethanol metabolites is achieved. In addition, simultaneous measurement of creatinine content as an indicator of urine dilution helps to interpret the results. Method validation for EtG and EtS in DUS was satisfactory, showing the linearity of the calibration curves in the studied concentration range, good precision, accuracy and selectivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach for the determination of free and total valproic acid in small samples of 140 μL human plasma based on capillary electrophoresis with contactless conductivity detection is proposed. A dispersive liquid-liquid microextraction technique was employed in order to remove biological matrices prior to instrumental analysis. The free valproic acid was determined by isolating free valproic acid from protein-bound valproic acid by ultrafiltration under centrifugation of 100 μL sample. The filtrate was acidified to turn valproic acid into its protonated neutral form and then extracted. The determination of total valproic acid was carried out by acidifying 40 μL untreated plasma to release the protein-bound valproic acid prior to extraction. A solution consisting of 10 mM histidine, 10 mM 3-(N-morpholino)propanesulfonic acid and 10 μM hexadecyltrimethylammonium bromide of pH 6.5 was used as background electrolyte for the electrophoretic separation. The method showed good linearity in the range of 0.4-300 μg/mL with a correlation coefficient of 0.9996. The limit of detection was 0.08 μg/mL, and the reproducibility of the peak area was excellent (RSD=0.7-3.5%, n=3, for the concentration range from 1 to 150 μg/mL). The results for the free and total valproic acid concentration in human plasma were found to be comparable to those obtained with a standard immunoassay. The corresponding correlation coefficients were 0.9847 for free and 0.9521 for total valproic acid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In contrast to RIA, recently available ELISAs provide the potential for fully automated analysis of adiponectin. To date, studies reporting on the diagnostic characteristics of ELISAs and investigating on the relationship between ELISA- and RIA-based methods are rare. METHODS: Thus, we established and evaluated a fully automated platform (BEP 2000; Dade-Behring, Switzerland) for determination of adiponectin levels in serum by two different ELISA methods (competitive human adiponectin ELISA; high sensitivity human adiponectin sandwich ELISA; both Biovendor, Czech Republic). Further, as a reference method, we also employed a human adiponectin RIA (Linco Research, USA). Samples from 150 patients routinely presenting to our cardiology unit were tested. RESULTS: ELISA measurements could be accomplished in less than 3 h, measurement of RIA had a duration of 24 h. The ELISAs were evaluated for precision, analytical sensitivity and specificity, linearity on dilution and spiking recovery. In the investigated patients, type 2 diabetes, higher age and male gender were significantly associated with lower serum adiponectin concentrations. Correlations between the ELISA methods and the RIA were strong (competitive ELISA, r=0.82; sandwich ELISA, r=0.92; both p<0.001). However, Deming regression and Bland-Altman analysis indicated lack of agreement of the 3 methods preventing direct comparison of results. The equations of the regression lines are: Competitive ELISA=1.48 x RIA-0.88; High sensitivity sandwich ELISA=0.77 x RIA+1.01. CONCLUSIONS: Fully automated measurement of adiponectin by ELISA is feasible and substantially more rapid than RIA. The investigated ELISA test systems seem to exhibit analytical characteristics allowing for clinical application. In addition, there is a strong correlation between the ELISA methods and RIA. These findings might promote a more widespread use of adiponectin measurements in clinical research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microarrays have established as instrumental for bacterial detection, identification, and genotyping as well as for transcriptomic studies. For gene expression analyses using limited numbers of bacteria (derived from in vivo or ex vivo origin, for example), RNA amplification is often required prior to labeling and hybridization onto microarrays. Evaluation of the fidelity of the amplification methods is crucial for the robustness and reproducibility of microarray results. We report here the first utilization of random primers and the highly processive Phi29 phage polymerase to amplify material for transcription profiling analyses. We compared two commercial amplification methods (GenomiPhi and MessageAmp kits) with direct reverse-transcription as the reference method, focusing on the robustness of mRNA quantification using either microarrays or quantitative RT-PCR. Both amplification methods using either poly-A tailing followed by in vitro transcription, or direct strand displacement polymerase, showed appreciable linearity. Strand displacement technique was particularly affordable compared to in vitro transcription-based (IVT) amplification methods and consisted in a single tube reaction leading to high amplification yields. Real-time measurements using low-, medium-, and highly expressed genes revealed that this simple method provided linear amplification with equivalent results in terms of relative messenger abundance as those obtained by conventional direct reverse-transcription.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ATP-binding cassette transporter A1 (ABCA1) mediates the transport of cholesterol and phospholipids from cells to lipid-poor HDL and maintains cellular lipid homeostasis. Impaired ABCA1 function plays a role in lipid disorders, cardiovascular disease, atherosclerosis, and metabolic disorders. Despite the clinical importance of ABCA1, no method is available for quantifying ABCA1 protein. We developed a sensitive indirect competitive ELISA for measuring ABCA1 protein in human tissues using a commercial ABCA1 peptide and a polyclonal anti-ABCA1 antibody. The ELISA has a detection limit of 8 ng/well (0.08 mg/l) with a working range of 9-1000 ng/well (0.09-10 mg/l). Intra- and interassay coefficient of variations (CVs) were 6.4% and 9.6%, respectively. Good linearity (r = 0.97-0.99) was recorded in serial dilutions of human arterial and placental crude membrane preparations, and fibroblast lysates. The ELISA measurements for ABCA1 quantification in reference arterial tissues corresponded well with immunoblot analysis. The assay performance and clinical utility was evaluated with arterial tissues obtained from 15 controls and 44 patients with atherosclerotic plaques. ABCA1 protein concentrations in tissue lysates were significantly lower in patients (n = 24) as compared with controls (n = 5; 9.37 +/- 0.82 vs. 17.03 +/- 4.25 microg/g tissue; P < 0.01). The novel ELISA enables the quantification of ABCA1 protein in human tissues and confirms previous semiquantitative immunoblot results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methodological evaluation of the proteomic analysis of cardiovascular-tissue material has been performed with a special emphasis on establishing examinations that allow reliable quantitative analysis of silver-stained readouts. Reliability, reproducibility, robustness and linearity were addressed and clarified. In addition, several types of normalization procedures were evaluated and new approaches are proposed. It has been found that the silver-stained readout offers a convenient approach for quantitation if a linear range for gel loading is defined. In addition, a broad range of a 10-fold input (loading 20-200 microg per gel) fulfills the linearity criteria, although at the lowest input (20 microg) a portion of protein species will remain undetected. The method is reliable and reproducible within a range of 65-200 microg input. The normalization procedure using the sum of all spot intensities from a silver-stained 2D pattern has been shown to be less reliable than other approaches, namely, normalization through median or through involvement of interquartile range. A special refinement of the normalization through virtual segmentation of pattern, and calculation of normalization factor for each stratum provides highly satisfactory results. The presented results not only provide evidence for the usefulness of silver-stained gels for quantitative evaluation, but they are directly applicable to the research endeavor of monitoring alterations in cardiovascular pathophysiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the determination of menthol and menthol glucuronide (M-G) after enzymatic hydrolysis in plasma and urine of rats and humans was developed using headspace solid phase microextraction and gas chromatography-mass spectrometry in the selected ion monitoring mode (HS-SPME/GC-MS). The assay linearity for plasma ranged from 5 to 1000 ng/ml. The limit of quantification (LOQ) in plasma was 5 ng/ml. The intra- and inter-day precision for menthol and M-G were < or = 18.1% R.S.D. at the LOQ and < or = 4.0% at higher concentrations. Menthol and M-G were determined in rat and human plasma and urine after administration of menthol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method using gas chromatography-mass spectrometry (GC-MS) and solid-phase extraction (SPE) was developed for the determination of ajulemic acid (AJA), a non-psychoactive synthetic cannabinoid with interesting therapeutic potential, in human plasma. When using two calibration graphs, the assay linearity ranged from 10 to 750 ng/ml, and 750 to 3000 ng/ml AJA. The intra- and inter-day precision (R.S.D., %), assessed across the linear ranges of the assay, was between 1.5 and 7.0, and 3.6 and 7.9, respectively. The limit of quantitation (LOQ) was 10 ng/ml. The amount of AJA glucuronide was determined by calculating the difference in the AJA concentration before ("free AJA") and after enzymatic hydrolysis ("total AJA"). The present method was used within a clinical study on 21 patients suffering from neuropathic pain with hyperalgesia and allodynia. For example, plasma levels of 599.4+/-37.2 ng/ml (mean+/-R.S.D., n=9) AJA were obtained for samples taken 2 h after the administration of an oral dose of 20 mg AJA. The mean AJA glucuronide concentration at 2h was 63.8+/-127.9 ng/ml.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Sound can reach the inner ear via at least two different pathways: air conduction and bone conduction (BC). BC hearing is used clinically for diagnostic purposes and for BC hearing aids. Research on the motion of the human middle ear in response to BC stimulation is typically conducted using cadaver models. We evaluated middle ear motion of Thiel-embalmed whole-head specimens in terms of linearity, reproducibility, and consistency with the reported middle ear motion of living subjects, fresh cadaveric temporal bones, and whole-heads embalmed with a Non-Thiel solution of salts. METHODS We used laser Doppler vibrometry to measure the displacement of the skull, the umbo, the cochlear promontory, the stapes, and the round window in seven ears from four human whole-head specimens embalmed according to Thiel's method. The ears were stimulated with a Baha(®) implanted behind the auricle. RESULTS The Thiel model shows promontory velocity similar to that reported in the literature for whole-heads embalmed with a Non-Thiel solution of salts (0- to 7-dB difference). The Thiel heads' relative velocity of the stapes with respect to the promontory was similar to that of fresh cadaver temporal bones (0- to 4-dB difference). The velocity of the umbo was comparable in Thiel-embalmed heads and living subjects (0- to 10-dB difference). The skull and all middle ear elements measured responded linearly to different stimulation levels, with an average difference less than 1 dB. The variability of repeated measurements for both short- (2 h; 4 dB) and long-term (4-16 weeks; 6 dB) repetitions in the same ear, and the difference between the two ears of the same donor (approximately 10 dB) were lower than the inter-individual difference (up to 25 dB). CONCLUSION Thiel-embalmed human whole-head specimens can be used as an alternative model for the study of human middle ear mechanics secondary to BC stimulation. At some frequencies, differences from living subjects must be considered.