891 resultados para limits of visual detection
Resumo:
In this work methods for the multiresidue determination of the series of quinolones include in the European regulation in food of animal origin are de veloped and validated in line with Commission Decision 2002/657/EC in terms of linearity, decision limit, capability detection, precision and stability. Mult iresidue methods were established to allow the determination of quinolones covered by EU legislation in 2377/90/EC in muscle of chicken, turkey, pig and cow, plasma of cow and pig, liver of pig and milk of cow. First an extraction step was optimized and a SPE step was applied to clean!up and preconcentrate quinolones prior to their separation by CE or LC and determination by CE!UV, LC!UV, LC!Fl, LC!MS with different ion sources (ESI ,ApCI) and different mass analyser (Q, ToF) and LC!E SI!QqQ tandem mass spectrometry. The limits of quantification obtained are always lower than Maxim um Residue Limit (MRL) established by EU for quinolones in animal products and they can be applied to the control of quinolones in foodstuffs of animal origin . Finally the proposed methods were applied to determine quinolones in samples of turkey and pig muscle, pig plasma and milk of cow. Excellent quality parameters and reduced time of analysis were obtained when LC!ESI!MS/MS is used, although the others techniques presented too satisfactory results.
Resumo:
In order to spare functional areas during the removal of brain tumours, electrical stimulation mapping was used in 90 patients (77 in the left hemisphere and 13 in the right; 2754 cortical sites tested). Language functions were studied with a special focus on comprehension of auditory and visual words and the semantic system. In addition to naming, patients were asked to perform pointing tasks from auditory and visual stimuli (using sets of 4 different images controlled for familiarity), and also auditory object (sound recognition) and Token test tasks. Ninety-two auditory comprehension interference sites were observed. We found that the process of auditory comprehension involved a few, fine-grained, sub-centimetre cortical territories. Early stages of speech comprehension seem to relate to two posterior regions in the left superior temporal gyrus. Downstream lexical-semantic speech processing and sound analysis involved 2 pathways, along the anterior part of the left superior temporal gyrus, and posteriorly around the supramarginal and middle temporal gyri. Electrostimulation experimentally dissociated perceptual consciousness attached to speech comprehension. The initial word discrimination process can be considered as an "automatic" stage, the attention feedback not being impaired by stimulation as would be the case at the lexical-semantic stage. Multimodal organization of the superior temporal gyrus was also detected since some neurones could be involved in comprehension of visual material and naming. These findings demonstrate a fine graded, sub-centimetre, cortical representation of speech comprehension processing mainly in the left superior temporal gyrus and are in line with those described in dual stream models of language comprehension processing.
Resumo:
The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples
Resumo:
This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.
Resumo:
Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels
Resumo:
High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.
Resumo:
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).
Resumo:
A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status
Resumo:
A spectrofluorometric method has been developed and validated for the determination of gemfibrozil. The method is based on the excitation and emission capacities of gemfibrozil with excitation and emission wavelengths of 276 and 304 nm respectively. This method allows de determination of the drug in a self-nanoemulsifying drug delivery system (SNEDDS) for improve its intestinal absorption. Results obtained showed linear relationships with good correlation coefficients (r(2)>0.999) and low limits of detection and quantification (LOD of 0.075 μg mL(-1) and LOQ of 0.226 μg mL(-1)) in the range of 0.2-5 μg mL(-1), equally this method showed a good robustness and stability. Thus the amounts of gemfibrozil released from SNEDDS contained in gastro resistant hard gelatine capsules were analysed, and release studies could be performed satisfactorily.
Resumo:
Total lack of visual experience [dark rearing (DR)] is known to prolong the critical period and delay development of sensory functions in mammalian visual cortex. Recent results show that neurotrophins (NTs) counteract the effects of DR on functional properties of visual cortical cells and exert a strong control on critical period duration. NTs are known to modulate the development and synaptic efficacy of neurotransmitter systems that are affected by DR. However, it is still unknown whether the actions of NTs in dark-reared animals involve interaction with neurotransmitter systems. We have studied the effects of DR on the expression of key molecules in the glutamatergic and GABAergic systems in control and NT-treated animals. We have found that DR reduced the expression of the NMDA receptor 2A subunit and its associated protein PSD-95 (postsynaptic density-95), of GRIP (AMPA glutamate receptor interacting protein), and of the biosynthetic enzyme GAD (glutamic acid decarboxylase). Returning dark-reared animals to light for 2 hr restored normal expression of the above-mentioned proteins almost completely. NT treatment specifically counteracts DR effects; NGF acts primarily on the NMDA system, whereas BDNF acts primarily on the GABAergic system. Finally, the action of NT4 seems to involve both excitatory and inhibitory systems. These data demonstrate that different NTs counteract DR effects by modulating the expression of key molecules of the excitatory and inhibitory neurotransmitter systems
Resumo:
BACKGROUND: In the context of population aging, visual impairment has emerged as a growing concern in public health. However, there is a need for further research into the relationship between visual impairment and chronic medical conditions in the elderly. The aim of our study was to examine the relationship between visual impairment and three main types of co-morbidity: chronic physical conditions (both at an independent and additive level), mental health and cognitive functioning. METHODS: Data were collected from the COURAGE in Europe project, a cross-sectional study. A total of 4,583 participants from Spain were included. Diagnosis of chronic medical conditions included self-reported medical diagnosis and symptomatic algorithms. Depression and anxiety were assessed using CIDI algorithms. Visual assessment included objective distance/near visual acuity and subjective visual performance. Descriptive analyses included the whole sample (n = 4,583). Statistical analyses included participants aged over 50 years (n = 3,625; mean age = 66.45 years) since they have a significant prevalence of chronic conditions and visual impairment. Crude and adjusted binary logistic regressions were performed to identify independent associations between visual impairment and chronic medical conditions, physical multimorbidity and mental conditions. Covariates included age, gender, marital status, education level, employment status and urbanicity. RESULTS: The number of chronic physical conditions was found to be associated with poorer results in both distance and near visual acuity [OR 1.75 (CI 1.38-2.23); OR 1.69 (CI 1.27-2.24)]. At an independent level, arthritis, stroke and diabetes were associated with poorer distance visual acuity results after adjusting for covariates [OR 1.79 (CI 1.46-2.21); OR 1.59 (CI 1.05-2.42); OR 1.27 (1.01-1.60)]. Only stroke was associated with near visual impairment [OR 3.01 (CI 1.86-4.87)]. With regard to mental health, poor subjective visual acuity was associated with depression [OR 1.61 (CI 1.14-2.27); OR 1.48 (CI 1.03-2.13)]. Both objective and subjective poor distance and near visual acuity were associated with worse cognitive functioning. CONCLUSIONS: Arthritis, stroke and the co-occurrence of various chronic physical diseases are associated with higher prevalence of visual impairment. Visual impairment is associated with higher prevalence of depression and poorer cognitive function results. There is a need to implement patient-centered care involving special visual assessment in these cases.
Resumo:
The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.
Resumo:
Harmane has been proposed for the treatment of epilepsy, AIDS and leshmaniosis. Its room-temperature phosphorescence was induced using either AgNO3 or TlNO3, enabling absolute limits of detection of 0.12 and 2.4 ng respectively, with linear dynamic ranges extending up to 456 ng (AgNO3) and 911 ng (TlNO3). Relative standard deviations around 3% were observed for substrates containing 46 ng of harmane. Such sensitivity and precision are needed because harmane intake must be strictly controlled to achieve proper therapeutic response. Interference studies were performed using thalidomide, reserpine and yohimbine. Recovery of 104±6% was achieved using solid surface room-temperature phosphorimetry. The result was comparable to the one obtained by micellar electrokinetic chromatography.
Resumo:
A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained.
Resumo:
A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.