1000 resultados para laser threshold
Resumo:
Hybridihitsaukseksi nimitetään yleensä hitsausprosesseja, joissa yhdistetään kaari- ja laserhitsauksen vahvuudet. Laser- MIG/MAG- prosessit ovat näistä selvästi yleisimpiä, mutta muillekin prosesseille on sovelluksia. Tässä kandidaatintyössä on arvioitu laser- plasma- hybridihitsausprosessin käytettävyyttä teollisuuden prosesseissa. Arviointi on tehty vertailevana kirjallisuustutkimuksena laser- plasma- hybridiprosessin, laserhitsauksen, sekä muiden laser- hybridihitsausprosessien kesken. Prosessien vertailun lisäksi työssä on käsitelty hybridihitsausprosessien parametrien valintaa ja laser- plasma- hybridiprosessin erityispiirteitä.
Resumo:
There exist several researches and applications about laser welding monitoring and parameter control but not a single one have been created for controlling of laser scribing processes. Laser scribing is considered to be very fast and accurate process and thus it would be necessary to develop accurate turning and monitoring system for such a process. This research focuses on finding out whether it would be possible to develop real-time adaptive control for ultra-fast laser scribing processes utilizing spectrometer online monitoring. The thesis accurately presents how control code for laser parameter tuning is developed using National Instrument's LabVIEW and how spectrometer is being utilized in online monitoring. Results are based on behavior of the control code and accuracy of the spectrometer monitoring when scribing different steel materials. Finally control code success is being evaluated and possible development ideas for future are presented.
Resumo:
Currently, laser scribing is growing material processing method in the industry. Benefits of laser scribing technology are studied for example for improving an efficiency of solar cells. Due high-quality requirement of the fast scribing process, it is important to monitor the process in real time for detecting possible defects during the process. However, there is a lack of studies of laser scribing real time monitoring. Commonly used monitoring methods developed for other laser processes such a laser welding, are sufficient slow and existed applications cannot be implemented in fast laser scribing monitoring. The aim of this thesis is to find a method for laser scribing monitoring with a high-speed camera and evaluate reliability and performance of the developed monitoring system with experiments. The laser used in experiments is an IPG ytterbium pulsed fiber laser with 20 W maximum average power and Scan head optics used in the laser is Scanlab’s Hurryscan 14 II with an f100 tele-centric lens. The camera was connected to laser scanner using camera adapter to follow the laser process. A powerful fully programmable industrial computer was chosen for executing image processing and analysis. Algorithms for defect analysis, which are based on particle analysis, were developed using LabVIEW system design software. The performance of the algorithms was analyzed by analyzing a non-moving image from the scribing line with resolution 960x20 pixel. As a result, the maximum analysis speed was 560 frames per second. Reliability of the algorithm was evaluated by imaging scribing path with a variable number of defects 2000 mm/s when the laser was turned off and image analysis speed was 430 frames per second. The experiment was successful and as a result, the algorithms detected all defects from the scribing path. The final monitoring experiment was performed during a laser process. However, it was challenging to get active laser illumination work with the laser scanner due physical dimensions of the laser lens and the scanner. For reliable error detection, the illumination system is needed to be replaced.
Resumo:
The process of depositing thin films by the use of pulsed laser deposition (PLD) has become a more widely used technique for the growth of substances in a thin film form. Pulsed laser deposition allows for the stoichiometric film growth of the target which is of great significance in the deposition of High Temperature Superconducting materials. We will describe a system designed using an excimer laser and vaccum chamber in which thin films and superlattices of YBa2Cuj07_i, PrBa2Cu307_i, and YBajCujOr-j/ PrBajCusOr-^ were deposited on SrTiOs. Results of resistivity measurements using the four probe technique will be shown.
Resumo:
A Czerny Mount double monochromator is used to measure Raman scattered radiation near 90" from a crystalline, Silicon sample. Incident light is provided by a mixed gas Kr-Ar laser, operating at 5145 A. The double monochromator is calibrated to true wavelength by comparison of Kr and Ar emission Une positions (A) to grating position (A) display [1]. The relationship was found to be hnear and can be described by, y = 1.219873a; - 1209.32, (1) where y is true wavelength (A) and xis grating position display (A). The Raman emission spectra are collected via C"*""*" encoded software, which displays a mV signal from a Photodetector and allows stepping control of the gratings via an A/D interface. [2] The software collection parameters, detector temperature and optics are optimised to yield the best quality spectra. The inclusion of a cryostat allows for temperatmre dependent capabihty ranging from 4 K to w 350 K. Silicon Stokes temperatm-e dependent Raman spectra, generally show agreement with Uterature results [3] in their frequency haxdening, FWHM reduction and intensity increase as temperature is reduced. Tests reveal that a re-alignment of the double monochromator is necessary before spectral resolution can approach literature standard. This has not yet been carried out due to time constraints.
Resumo:
SrMg^Rui-iOa thin films were made by using pulsed laser deposition on SrTiOa (100) substrates in either O2 or Ar atmosphere. The thin films were characterized by x-ray diffraction, energy dispersive x-ray microanalysis, dc resistivity measurement, and dc magnetization measurement. The effect of Mg doping was observed. As soon as the amount of Mg increased in SrMg-cRui-iOa thin films, the magnetization decreased, and the resistivity increased. It had little effect on the Curie temperature (transition temperature). The magnetization states of SrMgiRui-iOa thin films, for x < 0.15, are similar to SrRuOs films. X-ray diffraction results for SrMga-Rui-iOa thin films made in oxygen showed that the films are epitaxial. The thin films could not be well made in Ar atmosphere during laser ablation as there was no clear peak of SrMg^Rui-iOa in x-ray diffraction results. Substrate temperatures had an effect on the resistivity of the films. The residual resistivity ratios were increased by increasing substrate temperature. It was observed that the thickness of thin films are another factor for film quality: Thin films were epitaxial, but thicker films were not epitaxial.
Resumo:
Basal body temperature (BBT) and thermoeffector thresholds increase following ovulation in
many women. This study investigated if solely central thermoregulatory alterations are responsible.
Seven females in a non-contraceptive group (NCG) were compared with 5 monophasic contraceptive
users (HCG) on separate accounts: pre-ovulation (Trial I; d 2-5) and post-ovulation (Trial 2; 4-8 d
post-positive ovulation) for NCG, and active phase for HCG (d 2-5, d 18-21). During immersion in
28°C water to the axilla, participants exercised for 20-30 min on an underwater ergometer. After
steadily sweating, immersion continued until metabolism increased two-fold due to shivering. Rectal
(Tre) BBT was not different between trials for neither NCG (1: 37.34±0.16°C; 2: 37.35±0.27°C) nor
HCG. At exercise termination, Tre forehead sweating cessation increased (P<0.05) in trial 2
irrespective of group (1: 37.55±0.39°C; 2: 37.90±0,46°C). Tre shivering onset did not increase
(P>0.05) in trial 2 (1: 36.91±0.50°C; 2: 37.07±0,45°C). The widths of the interthreshold zone
increased (P<0.05) in trial 2 (1: 0.64±0.22°C; 2: 0.82±0.37°C) due to the increased sweating threshold
only. HCG cooled quicker (1: -l.15±0,43°C; 2: -1.00±0.50°C) than NCG participants (1: -
0.58±0.22°C; 2: -0.52±O.29°C), and tympanic (Tty) sweat thresholds were significantly (P<0.05)
decreased (1: 34.76±0.54°C; 2: 35.39±0.61°C) versus NCG (l: 35.57±0.77°C; 2: 35.89±1.04°C).
Lastly, Tre and Tty thresholds were significantly different (P
Resumo:
Recent research suggests that participating in vigorous synchronized physical activity may result in elevated levels of endorphins, which may in turn affect social bonding (Cohen et. al., 2009). The present research aimed to examine whether or not the change in pain tolerance would be able to predict participants’ willingness to cooperate after statistically controlling for the groups’ condition. Participants were asked to run on a treadmill for 30 minutes under one of two conditions (control vs. synchronized). Prior to and after the run participants underwent a pain tolerance test. Once completed, a second activity was introduced to the participants; a cooperative game. A public goods game was used to measure an individual’s willingness to cooperate. The results showed the synchronized condition was able to predict that participants cooperated more during the public goods game (p = .009), however the change in pain threshold was unable to significantly predict cooperation (p = .32).
Resumo:
The electromyographic threshold (EMGTh), defined as an upward inflexion in the rising EMG signal during progressive exercise, is thought to reflect the onset of increased type-II MU recruitment. The study’s objective was to compare the relative exercise intensity at which the EMGTh occurs in boys vs. men. Participants included 21 men (23.4±4.1 yrs) and 23 boys (11.1±1.1 yrs). Ramped cycle-ergometry was conducted to volitional exhaustion with surface EMG recorded from the vastus lateralis muscles. The EMGTh was mathematically determined using a composite of both legs. EMGTh was detected in 95.2% of the men and in 78.3% of the boys (χ2(1, n=44) =2.69, p =.10). The boys’ EMGTh was significantly higher than the men’s (86.4±9.6 vs. 79.7±10.0% of peak power-output at exhaustion; p <.05). These findings suggest that boys activate their type-II MUs to a lesser extent than men during progressive exercise and support the hypothesis of differential child–adult MU activation.
Resumo:
Abstract Background Children have been shown to have higher lactate (LaTh) and ventilatory (VeTh) thresholds than adults, which might be explained by lower levels of type-II motor-unit (MU) recruitment. However, the electromyographic threshold (EMGTh), regarded as indicating the onset of accelerated type-II MU recruitment, has been investigated only in adults. Purpose To compare the relative exercise intensity at which the EMGTh occurs in boys versus men. Methods Participants were 21 men (23.4 ± 4.1 years) and 23 boys (11.1 ± 1.1 years), with similar habitual physical activity and peak oxygen consumption (VO2pk) (49.7 ± 5.5 vs. 50.1 ± 7.4 ml kg−1 min−1, respectively). Ramped cycle ergometry was conducted to volitional exhaustion with surface EMG recorded from the right and left vastus lateralis muscles throughout the test (~10 min). The composite right–left EMG root mean square (EMGRMS) was then calculated per pedal revolution. The EMGTh was then determined as the exercise intensity at the point of least residual sum of squares for any two regression line divisions of the EMGRMS plot. Results EMGTh was detected in 20/21 of the men (95.2 %) and only in 18/23 of the boys (78.3 %). The boys’ EMGTh was significantly higher than the men’s (86.4 ± 9.6 vs. 79.7 ± 10.0 % of peak power output at exhaustion; p < 0.05). The pattern was similar when EMGTh was expressed as percentage of VO2pk. Conclusions The boys’ higher EMGTh suggests delayed and hence lesser utilization of type-II MUs in progressive exercise, compared with men. The boys–men EMGTh differences were of similar magnitude as those shown for LaTh and VeTh, further suggesting a common underlying factor.
Resumo:
Tesis (Maestría en Ciencias en Ingeniería Eléctrica con Especialidad en Potencia) UANL
Resumo:
La caractérisation de matériaux par spectroscopie optique d’émission d’un plasma induit par laser (LIPS) suscite un intérêt qui ne va que s’amplifiant, et dont les applications se multiplient. L’objectif de ce mémoire est de vérifier l’influence du choix des raies spectrales sur certaines mesures du plasma, soit la densité électronique et la température d’excitation des atomes neutres et ionisés une fois, ainsi que la température d’ionisation. Nos mesures sont intégrées spatialement et résolues temporellement, ce qui est typique des conditions opératoires du LIPS, et nous avons utilisé pour nos travaux des cibles binaires d’aluminium contenant des éléments à l’état de trace (Al-Fe et Al-Mg). Premièrement, nous avons mesuré la densité électronique à l’aide de l’élargissement Stark de raies de plusieurs espèces (Al II, Fe II, Mg II, Fe I, Mg I, Halpha). Nous avons observé que les densités absolues avaient un comportement temporel différent en fonction de l’espèce. Les raies ioniques donnent des densités électroniques systématiquement plus élevées (jusqu’à 50 % à 200 ns après l’allumage du plasma), et décroissent plus rapidement que les densités issues des raies neutres. Par ailleurs, les densités obtenues par les éléments traces Fe et Mg sont moindres que les densités obtenues par l’observation de la raie communément utilisée Al II à 281,618 nm. Nous avons parallèlement étudié la densité électronique déterminée à l’aide de la raie de l’hydrogène Halpha, et la densité électronique ainsi obtenue a un comportement temporel similaire à celle obtenue par la raie Al II à 281,618 nm. Les deux espèces partagent probablement la même distribution spatiale à l’intérieur du plasma. Finalement, nous avons mesuré la température d’excitation du fer (neutre et ionisé, à l’état de trace dans nos cibles), ainsi que la température d’ionisation, à l’aide de diagrammes de Boltzmann et de Saha-Boltzmann, respectivement. À l’instar de travaux antérieurs (Barthélémy et al., 2005), il nous est apparu que les différentes températures convergeaient vers une température unique (considérant nos incertitudes) après 2-3 microsecondes. Les différentes températures mesurées de 0 à 2 microsecondes ne se recoupent pas, ce qui pourrait s’expliquer soit par un écart à l’équilibre thermodynamique local, soit en considérant un plasma inhomogène où la distribution des éléments dans la plume n’est pas similaire d’un élément à l’autre, les espèces énergétiques se retrouvant au cœur du plasma, plus chaud, alors que les espèces de moindre énergie se retrouvant principalement en périphérie.
Investigation of femtosecond laser technology for the fabrication of drug nanocrystals in suspension
Resumo:
La technique du laser femtoseconde (fs) a été précédemment utilisée pour la production de nanoparticules d'or dans un environnement aqueux biologiquement compatible. Au cours de ce travail de maîtrise, cette méthode a été investiguée en vue d'une application pour la fabrication de nanocristaux de médicament en utilisant le paclitaxel comme modèle. Deux procédés distincts de cette technologie à savoir l'ablation et la fragmentation ont été étudiés. L'influence de la puissance du laser, de point de focalisation, et de la durée du traitement sur la distribution de taille des particules obtenues ainsi que leur intégrité chimique a été évaluée. Les paramètres ont ainsi été optimisés pour la fabrication des nanoparticules. L’évaluation morphologique et chimique a été réalisée par microscopie électronique et spectroscopie infrarouge respectivement. L'état cristallin des nanoparticules de paclitaxel a été caractérisé par calorimétrie differentielle et diffraction des rayons X. L'optimisation du procédé de production de nanoparticules par laser fs a permis d'obtenir des nanocristaux de taille moyenne (400 nm, polydispersité ≤ 0,3). Cependant une dégradation non négligeable a été observée. La cristallinité du médicament a été maintenue durant la procédure de réduction de taille, mais le paclitaxel anhydre a été transformé en une forme hydratée. Les résultats de cette étude suggèrent que le laser fs peut générer des nanocristaux de principe actif. Cependant cette technique peut se révéler problématique pour des médicaments sensibles à la dégradation. Grâce à sa facilité d'utilisation et la possibilité de travailler avec des quantités restreintes de produit, le laser fs pourrait représenter une alternative valable pour la production de nanoparticules de médicaments peu solubles lors des phases initiales de développement préclinique. Mots-clés: paclitaxel, nanocristaux, laser femtoseconde, ablation, fragmentation
Resumo:
La débitmétrie au laser à effet Doppler (LDF) constitue une méthode prometteuse et non-invasive pour l'étude du débit sanguin local dans l'œil. Cette technique est basée sur un changement de fréquence subi par la lumière lors du mouvement des globules rouges dans les vaisseaux. Une nouvelle sonde LDF a été testée pour sa sensibilité à évaluer la circulation rétinienne/choroïdienne sous des conditions hypercapniques et en présence de diverses substances vasoactives ou suivant la photocoagulation des artères rétiniennes chez le rat. Après dilatation pupillaire, la sonde LDF a été placée en contact avec la cornée de rats anesthésiés et parallèle à l'axe optique. L'hypercapnie a été provoquée par inhalation de CO2 (8% dans de l'air médical), alors que les agents pharmacologiques ont été injectés de façon intravitréenne. La contribution relative à la circulation choroïdienne a été évaluée à la suite de la photocoagulation des artères rétiniennes. Le débit sanguin s'est trouvé significativement augmenté à la suite de l'hypercanie (19%), de l'adénosine (14%) ou du nitroprusside de sodium (16%) comparativement au niveau de base, alors que l'endothéline-1 a provoqué une baisse du débit sanguin (11%). La photocoagulation des artères rétiniennes a significativement diminué le débit sanguin (33%). Des mesures en conditions pathologiques ont ensuite été obtenues après l'injection intravitréenne d'un agoniste sélectif du récepteur B1 (RB1). Ce récepteur des kinines est surexprimé dans la rétine des rats rendus diabétiques avec la streptozotocine (STZ) en réponse à l'hyperglycémie et au stress oxydatif. Les résultats ont montré que le RB1 est surexprimé dans la rétine chez les rats diabétiques-STZ à 4 jours et 6 semaines. À ces moments, le débit sanguin rétinien/choroïdien a été significativement augmenté (15 et 18 %) après l'injection de l'agoniste, suggérant un effet vasodilatateur des RB1 dans l'œil diabétique. Bien que la circulation choroïdienne contribue probablement au signal LDF, les résultats démontrent que le LDF représente une technique efficace et non-invasive pour l'étude de la microcirculation rétinienne in-vivo en continu. Cette méthode peut donc être utilisée pour évaluer de façon répétée les réponses du débit sanguin pendant des modifications métaboliques ou pharmacologiques dans des modèles animaux de maladies oculaires.