781 resultados para fluorescein angiography
Resumo:
AIMS Proprotein convertase subtilisin kexin 9 (PCSK9) is an emerging target for the treatment of hypercholesterolaemia, but the clinical utility of PCSK9 levels to guide treatment is unknown. We aimed to prospectively assess the prognostic value of plasma PCSK9 levels in patients with acute coronary syndromes (ACS). METHODS AND RESULTS Plasma PCSK9 levels were measured in 2030 ACS patients undergoing coronary angiography in a Swiss prospective cohort. At 1 year, the association between PCSK9 tertiles and all-cause death was assessed adjusting for the Global Registry of Acute Coronary Events (GRACE) variables, as well as the achievement of LDL cholesterol targets of <1.8 mmol/L. Patients with higher PCSK9 levels at angiography were more likely to have clinical familial hypercholesterolaemia (rate ratio, RR 1.21, 95% confidence interval, CI 1.09-1.53), be treated with lipid-lowering therapy (RR 1.46, 95% CI 1.30-1.63), present with longer time interval of chest pain (RR 1.29, 95% CI 1.09-1.53) and higher C-reactive protein levels (RR 1.22, 95% CI 1.16-1.30). PCSK9 increased 12-24 h after ACS (374 ± 149 vs. 323 ± 134 ng/mL, P < 0.001). At 1 year follow-up, HRs for upper vs. lower PCSK9-level tertiles were 1.13 (95% CI 0.69-1.85) for all-cause death and remained similar after adjustment for the GRACE score. Patients with higher PCSK9 levels were less likely to reach the recommended LDL cholesterol targets (RR 0.81, 95% CI 0.66-0.99). CONCLUSION In ACS patients, high initial PCSK9 plasma levels were associated with inflammation in the acute phase and hypercholesterolaemia, but did not predict mortality at 1 year.
Resumo:
BACKGROUND The distribution of thrombus-containing lesions (TCLs) in an all-comer population admitted with a heterogeneous clinical presentation (stable, ustable angina, or an acute coronary syndrome) and treated with percutaneous coronary intervention is yet unclear, and the long-term prognostic implications are still disputed. This study sought to assess the distribution and prognostic implications of coronary thrombus, detected by coronary angiography, in a population recruited in all-comer percutaneous coronary intervention trials. METHODS AND RESULTS Patient-level data from 3 contemporary coronary stent trials were pooled by an independent academic research organization (Cardialysis, Rotterdam, the Netherlands). Clinical outcomes in terms of major adverse cardiac events (major adverse cardiac events, a composite of death, myocardial infarction, and repeat revascularization), death, myocardial infarction, and repeated revascularization were compared between patients with and without angiographic TCL. Preprocedural TCL was present in 257 patients (5.8%) and absent in 4193 (94.2%) patients. At 3-year follow-up, there was no difference for major adverse cardiac events (25.3 versus 25.4%; P=0.683); all-cause death (7.4 versus 6.8%; P=0.683); myocardial infarction (5.8 versus 6.0%; P=0.962), and any revascularizations (17.5 versus 17.7%; P=0.822) between patients with and without TCL. The comparison of outcomes in groups weighing the jeopardized myocardial by TCL also did not show a significant difference. TCL were seen more often in the first 2 segments of the right (43.6%) and left anterior descending (36.8%) coronary arteries. The association of TCL and bifurcation lesions was present in 40.1% of the prespecified segments. CONCLUSIONS TCL involved mainly the proximal coronary segments and did not have any effect on clinical outcomes. A more detailed thrombus burden quantification is required to investigate its prognostic implications. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00114972, NCT01443104, NCT00617084.
Resumo:
Cochlear implants are neuroprostheses that are inserted into the inner ear to directly electrically stimulate the auditory nerve, thus replacing lost cochlear receptors, the hair cells. The reduction of the gap between electrodes and nerve cells will contribute to technological solutions simultaneously increasing the frequency resolution, the sound quality and the amplification of the signal. Recent findings indicate that neurotrophins (NTs) such as brain derived neurotrophic factor (BDNF) stimulate the neurite outgrowth of auditory nerve cells by activating Trk receptors on the cellular surface (1–3). Furthermore, small-size TrkB receptor agonists such as di-hydroxyflavone (DHF) are now available, which activate the TrkB receptor with similar efficiency as BDNF, but are much more stable (4). Experimentally, such molecules are currently used to attract nerve cells towards, for example, the electrodes of cochlear implants. This paper analyses the scenarios of low dose aspects of controlled release of small-size Trk receptor agonists from the coated CI electrode array into the inner ear. The control must first ensure a sufficient dose for the onset of neurite growth. Secondly, a gradient in concentration needs to be maintained to allow directive growth of neurites through the perilymph-filled gap towards the electrodes of the implant. We used fluorescein as a test molecule for its molecular size similarity to DHF and investigated two different transport mechanisms of drug dispensing, which both have the potential to fulfil controlled low-throughput drug-deliverable requirements. The first is based on the release of aqueous fluorescein into water through well-defined 60-μm size holes arrays in a membrane by pure osmosis. The release was both simulated using the software COMSOL and observed experimentally. In the second approach, solid fluorescein crystals were encapsulated in a thin layer of parylene (PPX), hence creating random nanometer-sized pinholes. In this approach, the release occurred due to subsequent water diffusion through the pinholes, dissolution of the fluorescein and then release by out-diffusion. Surprisingly, the release rate of solid fluorescein through the nanoscopic scale holes was found to be in the same order of magnitude as for liquid fluorescein release through microscopic holes.
Resumo:
BACKGROUND AND PURPOSE The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.
Resumo:
AIM To identify morphologic factors affecting aortic expansion in patients with uncomplicated type B aortic dissections. METHODS Computed tomography data of 24 patients (18 male; median age: 61 years), diagnosed with acute uncomplicated type B aortic dissections between 2002 and 2013, were retrospectively reviewed. All patients had at least two computed tomography angiography scans and six months of uneventful follow-up. Computed tomography scans were assessed by two independent readers with regard to presence and number of entry tears. Thoracic and abdominal aortic diameters were derived using image processing software. RESULTS Twenty-two of 24 patients showed aortic expansion over a median computed tomography angiographic follow-up of 33.2 months. Annual rates showed an increase of 1.7 mm for total aortic diameter, 2.1 mm for the false and a decrease of -0.4 mm for the true lumen. In three patients (12.5%), aortic diameter exceeded 60 mm during follow-up, and all three patients underwent thoracic endovascular aortic repair. Patients with a maximum aortic diameter <4 cm at baseline showed a significantly higher expansion rate compared to cases with an initial maximum aortic diameter of ≥4 cm (p=0.0471). A median of two entries (range: 1-5) was recognized per patient. Presence of more than two entry tears (n = 13) was associated with faster overall diameter expansion (mean annual rates: 2.18 mm vs. 1.16 mm; p = 0.4556), and decrease of the cross-sectional surface of the true lumen over time (annual rate for > 2 entries vs. ≤2 entries: -7.8 mm(2) vs. +37.5 mm(2); p = 0.0369). Median size of entry tears was 12 mm (range: 2-53 mm). CONCLUSIONS The results presented herein suggest that uncomplicated type B aortic dissection patients with more than two entry tears and/or an initial maximum aortic diameter of<4 cm are at risk for aortic dilatation and, therefore, may require stricter follow-up including the possible need for early intervention.
Resumo:
PURPOSE The purpose of this study was to identify morphologic factors affecting type I endoleak formation and bird-beak configuration after thoracic endovascular aortic repair (TEVAR). METHODS Computed tomography (CT) data of 57 patients (40 males; median age, 66 years) undergoing TEVAR for thoracic aortic aneurysm (34 TAA, 19 TAAA) or penetrating aortic ulcer (n = 4) between 2001 and 2010 were retrospectively reviewed. In 28 patients, the Gore TAG® stent-graft was used, followed by the Medtronic Valiant® in 16 cases, the Medtronic Talent® in 8, and the Cook Zenith® in 5 cases. Proximal landing zone (PLZ) was in zone 1 in 13, zone 2 in 13, zone 3 in 23, and zone 4 in 8 patients. In 14 patients (25%), the procedure was urgent or emergent. In each case, pre- and postoperative CT angiography was analyzed using a dedicated image processing workstation and complimentary in-house developed software based on a 3D cylindrical intensity model to calculate aortic arch angulation and conicity of the landing zones (LZ). RESULTS Primary type Ia endoleak rate was 12% (7/57) and subsequent re-intervention rate was 86% (6/7). Left subclavian artery (LSA) coverage (p = 0.036) and conicity of the PLZ (5.9 vs. 2.6 mm; p = 0.016) were significantly associated with an increased type Ia endoleak rate. Bird-beak configuration was observed in 16 patients (28%) and was associated with a smaller radius of the aortic arch curvature (42 vs. 65 mm; p = 0.049). Type Ia endoleak was not associated with a bird-beak configuration (p = 0.388). Primary type Ib endoleak rate was 7% (4/57) and subsequent re-intervention rate was 100%. Conicity of the distal LZ was associated with an increased type Ib endoleak rate (8.3 vs. 2.6 mm; p = 0.038). CONCLUSIONS CT-based 3D aortic morphometry helps to identify risk factors of type I endoleak formation and bird-beak configuration during TEVAR. These factors were LSA coverage and conicity within the landing zones for type I endoleak formation and steep aortic angulation for bird-beak configuration.
Resumo:
OBJECTIVES The aim of this study was to compare the efficacy of amphilimus-eluting stents (AES) with that of everolimus-eluting stents (EES) in patients with diabetes mellitus (DM). BACKGROUND The AES is a polymer-free drug-eluting stent that elutes sirolimus formulated with an amphiphilic carrier from laser-dug wells. This technology could be associated with a high efficacy in patients with DM. METHODS This was a multicenter, randomized, noninferiority trial. Patients with DM medically treated with oral glucose-lowering agents or insulin and de novo coronary lesions were randomized in a 1:1 fashion to AES or EES. The primary endpoint was the neointimal (NI) volume obstruction assessed by optical coherence tomography at 9-month follow-up. RESULTS A total of 116 lesions in 112 patients were randomized. Overall, 40% were insulin-treated patients, with a median HbA1c of 7.3% (interquartile range: 6.7% to 8.0%). The primary endpoint, NI volume obstruction, was 11.97 ± 5.94% for AES versus 16.11 ± 18.18% for EES, meeting the noninferiority criteria (p = 0.0003). Pre-specified subgroup analyses showed a significant interaction between stent type and glycemic control (p = 0.02), with a significant reduction in NI hyperplasia in the AES group in patients with the higher HbA1c (p = 0.03). By quantitative coronary angiography, in-stent late loss was 0.14 ± 0.24 for AES versus 0.24 ± 0.57 mm for EES (p = 0.27), with a larger minimal lumen diameter at follow-up for AES (p = 0.02), mainly driven by 2 cases of occlusive restenosis in the EES group. CONCLUSIONS AES are noninferior to EES for the coronary revascularization of patients with DM. These results suggest a high efficacy of the AES and may support the potential benefit of this stent in patients with DM. (A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus [RESERVOIR]; NCT01710748).
Resumo:
AIMS Bindarit (BND) is a selective inhibitor of monocyte chemotactic protein-1 (MCP-1/CCL2), which plays an important role in generating intimal hyperplasia. Our aim was to explore the efficacy and safety of bindarit in preventing restenosis following percutaneous coronary intervention. METHODS AND RESULTS A phase II, double-blind, multicentre randomised trial included 148 patients randomised into three arms (BND 600 mg, n=48; BND 1,200 mg, n=49; PLB, n=51). Bindarit was given following PCI and continued for 180 days. Monthly clinical follow-up and six-month coronary angiography were conducted. The primary endpoint was in-segment late loss; the main secondary endpoints were in-stent late loss and major adverse cardiovascular events. Efficacy analysis was carried out on two populations, ITT and PP. There were no significant differences in the baseline characteristics among the three treatment groups. In-segment and in-stent late loss at six months in BND 600, BND 1,200 and PLB were: (ITT 0.54 vs. 0.52 vs. 0.72; p=0.21), (PP 0.46 vs. 0.53 vs. 0.72; p=0.12) and (ITT 0.74 vs. 0.74 vs. 1.05; p=0.01), (PP 0.66 vs. 0.73 vs. 1.06; p=0.003), respectively. The MACE rates at nine months among treatment groups were 20.8% vs. 28.6% vs. 25.5% (p=0.54), respectively. CONCLUSIONS This was a negative study with the primary endpoint not being met. However, significant reduction in the in-stent late loss suggests that bindarit probably exerts a favourable action on the vessel wall following angioplasty. Bindarit was well tolerated with a compliance rate of over 90%. A larger study utilising a loading dose and targeting a specific patient cohort may demonstrate more significant results.
Resumo:
OBJETIVES The main objective of the present randomized pilot study was to explore the effects of upstream prasugrel or ticagrelor or clopidogrel for patients with ST-segment-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). BACKGROUND Administration of clopidogrel "as soon as possible" has been advocated for STEMI. Pretreatment with prasugrel and ticagrelor may improve reperfusion. Currently, the angiographic effects of upstream administration of these agents are poorly understood. METHODS A total of 132 patients with STEMI within the first 12 hr of chest pain referred to primary angioplasty were randomized to upstream clopidogrel (600 mg), prasugrel (60 mg), or ticagrelor (180 mg) while still in the emergency room. All patients underwent protocol-mandated thrombus aspiration. RESULTS Macroscopic thrombus material was retrieved in 79.5% of the clopidogrel group, 65.9% of the prasugrel group, and 54.3% of the ticagrelor group (P = 0.041). At baseline angiography, large thrombus burden was 97.7% vs. 87.8% vs. 80.4% in the clopidogrel, prasugrel, and ticagrelor groups, respectively (P = 0.036). Also, at baseline, 97.7% presented with an occluded target vessel in the clopidogrel group, 87.8% in the prasugrel group and 78.3% in the ticagrelor group (P = 0.019). At the end of the procedure, the percentages of patients with combined TIMI grade III flow and myocardial blush grade III were 52.3% for clopidogrel, 80.5% for prasugrel, and 67.4% for ticagrelor (P = 0.022). CONCLUSIONS In patients with STEMI undergoing primary PCI within 12 hr, upstream clopidogrel, prasugrel or ticagrelor have varying angiographic findings, with a trend toward better results for the latter two agents. © 2015 Wiley Periodicals, Inc.
Resumo:
Ischemic complications during aneurysm surgery are a frequent cause of postoperative infarctions and new neurological deficits. In this article, we discuss imaging and neurophysiological tools that may help the surgeon to detect intraoperative ischemia. The strength of intraoperative digital subtraction angiography (DSA) is the full view of the arterial and venous vessel. DSA is the gold standard in complex and giant aneurysms, but due to certain disadvantages, it cannot be considered standard of care. Microvascular Doppler sonography is probably the fastest diagnostic tool and can quickly aid diagnosis of large vessel occlusions. Intraoperative indocyanine green videoangiography is the best tool to assess flow in perforating and larger arteries, as well as occlusion of the aneurysm sac. Intraoperative neurophysiological monitoring with somatosensory and motor evoked potentials indirectly measures blood flow by recording neuronal function. It covers all causes of intraoperative ischemia, provided that ischemia occurs in the brain areas under surveillance. However, every method has advantages and disadvantages. No single method is superior to the others in every aspect. Therefore, it is very important for the neurosurgeon to know the strengths and weaknesses of each tool in order to have them available, to know how to use them for each individual situation, and to be ready to apply them within the time window for reversible cerebral ischemia.
Resumo:
BACKGROUND The choice of imaging techniques in patients with suspected coronary artery disease (CAD) varies between countries, regions, and hospitals. This prospective, multicenter, comparative effectiveness study was designed to assess the relative accuracy of commonly used imaging techniques for identifying patients with significant CAD. METHODS AND RESULTS A total of 475 patients with stable chest pain and intermediate likelihood of CAD underwent coronary computed tomographic angiography and stress myocardial perfusion imaging by single photon emission computed tomography or positron emission tomography, and ventricular wall motion imaging by stress echocardiography or cardiac magnetic resonance. If ≥1 test was abnormal, patients underwent invasive coronary angiography. Significant CAD was defined by invasive coronary angiography as >50% stenosis of the left main stem, >70% stenosis in a major coronary vessel, or 30% to 70% stenosis with fractional flow reserve ≤0.8. Significant CAD was present in 29% of patients. In a patient-based analysis, coronary computed tomographic angiography had the highest diagnostic accuracy, the area under the receiver operating characteristics curve being 0.91 (95% confidence interval, 0.88-0.94), sensitivity being 91%, and specificity being 92%. Myocardial perfusion imaging had good diagnostic accuracy (area under the curve, 0.74; confidence interval, 0.69-0.78), sensitivity 74%, and specificity 73%. Wall motion imaging had similar accuracy (area under the curve, 0.70; confidence interval, 0.65-0.75) but lower sensitivity (49%, P<0.001) and higher specificity (92%, P<0.001). The diagnostic accuracy of myocardial perfusion imaging and wall motion imaging were lower than that of coronary computed tomographic angiography (P<0.001). CONCLUSIONS In a multicenter European population of patients with stable chest pain and low prevalence of CAD, coronary computed tomographic angiography is more accurate than noninvasive functional testing for detecting significant CAD defined invasively. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00979199.
Resumo:
AIMS High-density lipoproteins (HDLs) are considered as anti-atherogenic. Recent experimental findings suggest that their biological properties can be modified in certain clinical conditions by accumulation of serum amyloid A (SAA). The effect of SAA on the association between HDL-cholesterol (HDL-C) and cardiovascular outcome remains unknown. METHODS AND RESULTS We examined the association of SAA and HDL-C with mortality in the Ludwigshafen Risk and Cardiovascular Health (LURIC) study, which included 3310 patients undergoing coronary angiography. To validate our findings, we analysed 1255 participants of the German Diabetes and Dialysis study (4D) and 4027 participants of the Cooperative Health Research in the Region of Augsburg (KORA) S4 study. In LURIC, SAA concentrations predicted all-cause and cardiovascular mortality. In patients with low SAA, higher HDL-C was associated with lower all-cause and cardiovascular mortality. In contrast, in patients with high SAA, higher HDL-C was associated with increased all-cause and cardiovascular mortality, indicating that SAA indeed modifies the beneficial properties of HDL. We complemented these clinical observations by in vitro experiments, in which SAA impaired vascular functions of HDL. We further derived a formula for the simple calculation of the amount of biologically 'effective' HDL-C based on measured HDL-C and SAA from the LURIC study. In 4D and KORA S4 studies, we found that measured HDL-C was not associated with clinical outcomes, whereas calculated 'effective' HDL-C significantly predicted better outcome. CONCLUSION The acute-phase protein SAA modifies the biological effects of HDL-C in several clinical conditions. The concomitant measurement of SAA is a simple, useful, and clinically applicable surrogate for the vascular functionality of HDL.
Resumo:
Purpose. Fluorophotometry is a well validated method for assessing corneal permeability in human subjects. However, with the growing importance of basic science animal research in ophthalmology, fluorophotometry’s use in animals must be further evaluated. The purpose of this study was to evaluate corneal epithelial permeability following desiccating stress using the modified Fluorotron Master™. ^ Methods. Corneal permeability was evaluated prior to and after subjecting 6-8 week old C57BL/6 mice to experimental dry eye (EDE) for 2 and 5 days (n=9/time point). Untreated mice served as controls. Ten microliters of 0.001% sodium fluorescein (NaF) were instilled topically into each mouse’s left eye to create an eye bath, and left to permeate for 3 minutes. The eye bath was followed by a generous wash with Buffered Saline Solution (BSS) and alignment with the Fluorotron Master™. Seven corneal scans using the Fluorotron Master were performed during 15 minutes (1 st post-wash scans), followed by a second wash using BSS and another set of five corneal scans (2nd post-wash scans) during the next 15 minutes. Corneal permeability was calculated using data calculated with the FM™ Mouse software. ^ Results. When comparing the difference between the Post wash #1 scans within the group and the Post wash #2 scans within the group using a repeated measurement design, there was a statistical difference in the corneal fluorescein permeability of the Post-wash #1 scans after 5 days (1160.21±108.26 vs. 1000.47±75.56 ng/mL, P<0.016 for UT-5 day comparison 8 [0.008]), but not after only 2 days of EDE compared to Untreated mice (1115.64±118.94 vs. 1000.47±75.56 ng/mL, P>0.016 for UT-2 day comparison [0.050]). There was no statistical difference between the 2 day and 5 day Post wash #1 scans (P=.299). The Post-wash #2 scans demonstrated that EDE caused a significant NaF retention at both 2 and 5 days of EDE compared to baseline, untreated controls (1017.92±116.25, 1015.40±120.68 vs. 528.22±127.85 ng/mL, P<0.05 [0.0001 for both]). There was no statistical difference between the 2 day and 5 day Post wash #2 scans (P=.503). The comparison between the Untreated post wash #1 with untreated post wash #2 scans using a Paired T-test showed a significant difference between the two sets of scans (P=0.000). There is also a significant difference between the 2 day comparison and the 5 day comparison (P values = 0.010 and 0.002, respectively). ^ Conclusion. Desiccating stress increases permeability of the corneal epithelium to NaF, and increases NaF retention in the corneal stroma. The Fluorotron Master is a useful and sensitive tool to evaluate corneal permeability in murine dry eye, and will be a useful tool to evaluate the effectiveness of dry eye treatments in animal-model drug trials.^
Resumo:
Coronary artery disease (CAD) is the most common cause of morbidity and mortality in the United States. While Coronary Angiography (CA) is the gold standard test to investigate coronary artery disease, Prospective gated-64 Slice Computed Tomography (Prosp-64CT) is a new non-invasive technology that uses the 64Slice computed tomography (64CT) with electrocardiographic gating to investigate coronary artery disease. The aim of the current study was to investigate the role of Body Mass Index (BMI) as a factor affecting occurrence of CA after a Prosp-64CT, as well as the quality of the Prosp-64CT. Demographic and clinical characteristics of the study population were described. A secondary analysis of data on patients who underwent a Prosp-64CT for evaluation of coronary artery disease was performed. Seventy seven patients who underwent Prosp-64CT for evaluation for coronary artery disease were included. Fifteen patients were excluded because they had missing data regarding BMI, quality of the Prosp-64CT or CA. Thus, a total of 62 patients were included in the final analysis. The mean age was 56.2 years. The mean BMI was 31.3 kg/m 2. Eight (13%) patients underwent a CA within one month of Prosp-64CT. Eight (13%) patients had a poor quality Prosp-64CT. There was significant association of higher BMI as a factor for occurrence of CA post Prosp-64CT (P<0.05). There was a trend, but no statistical significance was observed for the association of being obese and occurrence of CA (P=0.06). BMI, as well as obesity, were not found to be significantly associated with poor quality of Prosp-64CT (P=0.19 and P=0.76, respectively). In conclusion, BMI was significantly associated with occurrence of CA within one month of Prosp-64CT. Thus, in patients with a higher BMI, diagnostic investigation with both tests could be avoided; rather, only a CA could be performed. However, the relationship of BMI to quality of Prosp-64CT needs to be further investigated since the sample size of the current study was small.^