999 resultados para experimental e humana


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of Corynebacterium parvum on host protection, tissue reaction and "in vivo" chemotaxis in Schistosoma mansoni infected mice were studied. The C. parvum was given intraperitoneally using a dose of 0.7 mg, twice a week (for 4 weeks), thirty days before (prophylactic treatment) or after infection (curative treatment). The host protection was evaluated through the recovery of adult worms by liver perfusion and was lower in the prophylactic group as compared to the control group (p = 0.018), resulting in 44% protection. The "in vivo" leukocyte response in both prophylactic and curative groups was higher as compared to the infected/non treated group (p = 0.009 and p = 0.003, respectively). Tissue reactions were described in the experimental and control groups, but there were not remarkable differences among them. The possible biological implications and relevance of the findings for the defensive response of the host and control of schistosomiasis are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunosuppressed animals respond poorly to schistosomal chemotherapy and that a proper response can be restored by the administration of immune serum. Present study attempts to search whether immunological stimulation would increase drug effectiveness. Swiss mice infected with 50 S. mansoni cercariae were later treated with complete Freund's adjuvant. Treatment with oxaminiquine was made with 100 mg/kg.b.w., 25 mg/kg.b.w. and 50 mg/kg/b.w., the last two doses representing a fourth and a half of the recommended curative dose. Appropriate controls for the drug, the adjuvant and the infection were also studied. The serum-level of ant-S. mansoni antibodies (ELISA) and recovery of worms by perfusion of the portal vein system were the evaluated parameters. Statistical analysis of the results failed to reveal significant differences in worm recovery between adjuvant-stimulated animals treated with oxamniquine and any of the treated controls receiving the same amount of the drug. Although total lack of immunity interferes with curative treament the usual immune response seems to be sufficient to allow for curative drug action in schistosomiasis and thus apparently does not need to be artificially stimulated

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Mestrado Integrado em Engenharia Civil - Perfil de Construção

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Mestre em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau académico de Mestre em Engenharia Civil, na especialidade de Reabilitação de Edifícios, pela Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rehabilitation is becoming more and more usual in the construction sector in Portugal. The introduction of newer construction materials and technical know-how of integrating different materials for achieving desired engineering goals is an important step to the development of the sector. Wood industry is also getting more and more adapted to composite technologies with the introduction of the so called “highly engineered wood products” and with the use of modification treatments. This work is an attempt to explain the viability of using stainless steel and glass fibre reinforced polymer (GFRP) as reinforcements in wood beams. This thesis specifically focuses on the flexural behaviour of Portuguese Pine unmodified and modified wood beams. Two types of modification were used: 1,3-dimethylol-4,5- dihydroxyethyleneurea (DMDHEU) resin and amid wax. The behaviour of the material was analysed with a nonlinear model. The latter model simulates the behaviour of the reinforced wood beams under flexural loading. Small-scale beams (1:15) were experimented in flexural bending and the experimental results obtained were compared with the analytical model results. The experiments confirm the viability of the reinforcing schemes and the working procedures. Experimental results showed fair agreement with the nonlinear model. A strength increase between 15% and 80% was achieved. Stiffness increased by 40% to 50% in beams reinforced with steel but no significant increase was achieved with the glass fibre reinforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para a obtenção do Grau de Mestre em Genética Molecular e Biomedicina, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection of Swiss/NIH mice with Leishmania major was compared with infection in isogenic resistant C57BL/6 and susceptible BALB/c mice. Swiss/NIH mice showed self-controlled lesions in the injected foot pad. The production of high levels of interferon-g (IFN-g) and low levels of interleukin-4 (IL-4) by cells from these animals suggests that they mount a Th1-type immune response. The importance of the indigenous microbiota on the development of murine leishmaniasis was investigated by infecting germfree Swiss/NIH in the hind footpad with L. major and conventionalizing after 3 weeks of infection. Lesions from conventionalized Swiss/NIH mice were significantly larger than conventional mice. Histopathological analysis of lesions from conventionalized animals showed abscesses of variable shapes and sizes and high numbers of parasitized macrophages. In the lesions from conventional mice, besides the absence of abscess formation, parasites were rarely observed. On the other hand, cells from conventional and conventionalized mice produced similar Th1-type response characterized by high levels of IFN-g and low levels of IL-4. In this study, we demonstrated that Swiss/NIH mice are resistant to L. major infection and that the absence of the normal microbiota at the beginning of infection significantly influenced the lesion size and the inflammatory response at the site of infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Após o enquadramento da canoagem, como modalidade Olímpica, verificou-se um aumento significativo de estudos e pesquisas acerca da biomecânica da modalidade, o que contribuiu para uma diminuição dos tempos na competição. Contudo poucos foram os que se focaram nas forças desenvolvidas e aplicadas ao caiaque através do finca-pés, criado assim oportunidade de desenvolvimento de dispositivos para a medição das mesmas. Assim, o objectivo primordial é desenvolver um sistema experimental capaz de quantificar as forças geradas em cada um dos lados do finca-pés (esquerdo e direito). Este, deverá não só ser passível de se utilizar em caiaque ergómetro como também num caiaque de pista, permitido avaliar as forças aplicadas durante o ciclo de pagaiada, tanto em compressão como em tracção. A sua concepção baseou-se num modelo de finca-pés já existente, tornando-o compatível com os caiaques de competição mais comercializados, e permitindo que no futuro se possa utilizar na água, bastando para isso apenas possuir um caiaque e embarcar o sistema de medição. Este sistema experimental foi testado em caiaque ergómetro por 7 (sete) sujeitos com níveis distintos: seis homens (um atleta olímpico medalhado e cinco de nível nacional) e uma mulher (de nível de selecção Portuguesa) que, entre outros, realizaram um plano definido por 60s a uma frequência de 75 pagaiadas por minuto, seguido de uma intensa mudança de ritmo e força (Sprint). Após análise dos dados obtidos em cada um dos diferentes sujeitos, conseguimos identificar algumas das suas características, tais como: esforço assimétrico dos membros inferiores; utilização de forma heterogénea da fita do finca-pés; diferença de forças máximas aplicadas entre atletas (Ex.: para um atleta olímpico as forças medidas (Min; Max): Pé Esquerdo (- 444; 1087) N e Pé Direito (- 476; 1068) N); etc. Os resultados não só são bastante promissores como também são motivantes e congruentes com estudos anteriores, nomeadamente Begon et al. 2008 e Sturm 2010 e 2012. Finalmente, consegue-se afirmar, com segurança, que foram alcançados os objectivos propostos com a concepção deste dispositivo de medição de forças. Este permite caracterizar os esforços desenvolvidos no finca-pés por cada membro inferior, com ou sem a fita de suporte, possibilitando aos treinadores e atletas uma visão, para muitos desconhecida, das forças transmitidas e das suas assimetrias. No final, este conhecimento permitirá aos atletas melhorar o seu desempenho desportivo bem como facilitar a gestão desportiva, com base nos principais princípios mecânicos inerentes ao movimento dos atletas desde desporto Olímpico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de mestre em Engenharia Biomédica.